Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Pol J Radiol ; 88: e311-e318, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37404551

RESUMO

Purpose: To assess the prevalence of the neuroradiological indices of brain atrophy in patients with severe aortic valve stenosis (AS) in magnetic resonance imaging (MRI) with particular emphasis on the assessment of atrophy areas typical of cerebral small vessel disease (CSVD). Material and methods: The group of 34 patients (age 60-90 years, 17 women and 17 men) with severe AS and 50 healthy controls (age 61-85 years, 29 women and 21 men) underwent MRI brain examinations, which were analysed for the neuroradiological indices of brain atrophy. Results: A slight but statistically significant age difference was found between the study and control groups - about 3 years on average (p = 0.040). Differences between total brain volumes in both the groups did not show statistical significance. In a comparative analysis of the main brain compartments, a statistically significant difference was found only in the volumetry of cerebral hemispheres for both the groups: mean volume of cerebral hemispheres in patients with severe AS was 884.46 cm3, while it was 17 cm3 bigger in the volunteer group, reaching 901.80 cm3 on average (p = 0.043). Comparison of the volumetry of the other major and minor regions and structures according to the clinical and anatomical division revealed statistically non-significant differences. No statistically significant relationships were observed concerning structures correlated with CSVD. Conclusions: Neuroradiological indices of the brain atrophy do not provide an unequivocal distinction in patients with severe AS. Most observations imply that brain atrophy in patients with severe AS is primarily a consequence of physiological ageing of the brain.

2.
Radiologie (Heidelb) ; 63(Suppl 2): 49-54, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37160478

RESUMO

OBJECTIVES: The aim of this study was to assess the size of the corpus callosum in members of Mensa International, which is the world's largest and oldest high-intelligence quotient (IQ) society. METHODS: We performed T2-weighted magnetic resonance imaging (Repetition Time, TR = 3200 ms, Time of Echo, TE = 409 ms) to examine the brain of members of Mensa International (Polish national group) in order to assess the size of the corpus callosum. Results from 113 male MENSA members and 96 controls in the age range of 21-40 years were analyzed. RESULTS: The comparative analysis showed that the mean length of the corpus callosum and the thickness of the isthmus were significantly greater in the Mensa members compared to the control groups. A statistically significant difference was also identified in the largest linear dimension of the brain from the frontal lobe to the occipital lobe. The mean corpus callosum cross-sectional area and its ratio to the brain area were significantly greater in the Mensa members. CONCLUSIONS: The results show that the dimensions (linear measures and midsagittal cross-sectional surface area) of the corpus callosum were significantly greater in the group of Mensa members than in the controls.


Assuntos
Corpo Caloso , Imageamento por Ressonância Magnética , Humanos , Masculino , Adulto Jovem , Adulto , Corpo Caloso/diagnóstico por imagem , Corpo Caloso/patologia , Imageamento por Ressonância Magnética/métodos , Testes de Inteligência , Encéfalo/diagnóstico por imagem , Inteligência
3.
Surg Radiol Anat ; 45(7): 893-899, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37178217

RESUMO

PURPOSE: To measure proximal ulna dorsal angulation (PUDA) and olecranon tip-to-apex distance (TTA) in pediatric population to aid surgeons with data for proximal ulna fractures fixation. METHODS: Retrospective review of the hospital radiographic database. All elbow radiographs were identified and after implementing exclusion criteria, included were 95 patients aged 0-10; 53 patients aged 11-14; and 53 patients aged 15-18. PUDA was defined as the angle between lines placed on the "flat spot" of the olecranon and the dorsal edge of the ulnar shaft and TTA as the distance between the tip of the olecranon to the apex of angulation. Two evaluators performed measurements independently. RESULTS: In age group 0-10, mean PUDA was 7.53°, range 3.8-13.7, 95% CI 7.16-7.91, while mean TTA was 22.04 mm, range 8.8-50.5, 95% CI 19.92-24.17. In age group 11-14, mean PUDA was 4.99°, range 2.5-9.3, 95% CI (4.61-5.37), while mean TTA was 37.41 mm, range 16.5-66.6, 95% CI (34.91-39.90). In age group 15-18, mean PUDA was 5.18°, range 2.9-8.1, 95% CI (4.75-5.61), while mean TTA was 43.79 mm, range 24.5-79.4, 95% CI (41.38-46.19). PUDA was negatively correlated with age (r = - 0.56, p < 0.001), while TTA was positively correlated with age (r = 0.77, p < 0.001). Reliability levels of 0.81-1 or 0.61-0.80 were achieved for most of intra- and inter-rater reliabilities besides two levels of 0.41-60 and one of 0.21-0.40. CONCLUSION: The main study finding is that in most cases mean age-group values may serve as a template for proximal ulna fixation. There are some cases in which X-ray of contralateral elbow may provide surgeon with a better template. LEVEL OF EVIDENCE: II.


Assuntos
Articulação do Cotovelo , Olécrano , Criança , Humanos , Adulto Jovem , Adulto , Olécrano/diagnóstico por imagem , Cotovelo , Reprodutibilidade dos Testes , Ulna/diagnóstico por imagem , Ulna/anatomia & histologia , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/cirurgia , Articulação do Cotovelo/anatomia & histologia , Estudos Retrospectivos
4.
Pol J Radiol ; 88: e47-e52, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36819218

RESUMO

Purpose: Endovascular procedures such as endovascular aneurysm repair or transcatheter aortic valve implantation have become very common because of reduced patient traumatisation and the ability to use shorter or local anaesthesia. In these procedures large-bore sheath devices are used. Access with percutaneous closure is an alternative method to surgical cutdown in groins. The aim of the study was to assess the correlation between sheath size and unsuccessful haemostasis. In addition, the effectiveness of haemostasis after a percutaneous procedure and the number and type of complications were evaluated. Material and methods: There were 202 patients included in the study. Patients with abdominal aortic aneurysm were qualified to percutaneous aortic stentgraft implantation with Perclose Proglide preclosure technique. Results: There were 384 access sites performed with 12F to 22F sheaths during aortic stentgraft implantation with Perclose Proglide (Abbott Vascular, Santa Clara, CA, USA) preclosure technique. High effectiveness of haemostasis (98%), low percentage of short- and mid-term complications (2.6%), and infinitesimal number of surgical conversions (n = 5) were stated in the study. There was no correlation between diameter of used introducer sheath and lack of haemostasis observed (Fisher-Freeman-Halton test; p = 0.122). No relationship between diameter of introducer sheath and number of closure devices was observed (c2 = 2.436; df = 5; p = 0.786). Conclusions: Large-bore device percutaneous procedures with closure devices are effective and safe. High effectiveness of haemostasis (98%) was observed in the study group, with a low percentage of complications (2.6%). There was no correlation between size of the vascular access and the lack of haemostasis found in the study.

5.
Diagnostics (Basel) ; 12(6)2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35741172

RESUMO

AIM OF THE STUDY: To determine the value of dynamic examinations ultrasound (US) and MRI in the 1.5T field in the assessment of the mobility of vocal folds (VF) in comparison to laryngoscopy in patients with thyroid gland resection. MATERIALS AND METHODS: A total of 44 patients with goiter, before and after thyroidectomy, were subjected to videolaryngoscopy and dynamic examinations of the vocal folds using ultrasound and the following MRI sequences: generic gradient echo (GRE) and true fast imaging with steady-state precession (TRUFI). The qualitative and quantitative data were analyzed, i.e., the angles of deviation from the midline of the vocal folds and the area of the right and left rima glottidis compartments. RESULTS: The analysis of qualitative data showed that the results obtained by laryngoscopy, US and MRI are independent of the diagnostic method used in the group of patients pre and post thyroidectomy. Between the pre- and postoperative examinations in the group of paralyzed vocal folds, statistically significant differences were found in the minimum and maximum values of the angles for the MRI-GRE and MRI-TRUFI sequences and the maximum value of the angles in the US examination, but also in the maximum value of the area of the glottis compartments in both MRI-GRE and MRI-TRUFI dynamic sequences and the minimum value of the area in the sequence MRI-GRE. Statistically significant differences were found in both MRI sequences during phonation, both for the value of the angles and the area of the affected vocal folds. However, no statistically significant differences were found in the values of the angles or the areas in both vocal fold imaging methods without identified mobility abnormalities. CONCLUSIONS: Ultrasound and MRI examinations using dynamic sequences have a similar diagnostic value to laryngoscopy in the assessment of vocal fold paralysis in patients with goiter. The GRE sequence seems to be the most reliable one in determining vocal fold paralysis, and the most reliable parameter is the maximum area of the rima glottidis compartment. The inclusion of dynamic short sequences widely available in 1.5T scanners in standard neck examination protocols represents a novelty of the method and a promising diagnostic perspective in the diagnosis of vocal fold paralysis.

6.
J Clin Med ; 11(9)2022 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-35566599

RESUMO

Stroke as the most frequent cause of disability is a challenge for the healthcare system as well as an important socio-economic issue. Therefore, there are currently a lot of studies dedicated to stroke recovery. Stroke recovery processes include angiogenesis and neuroplasticity and advances in neuroimaging techniques may provide indirect description of this action and become quantifiable indicators of these processes as well as responses to the therapeutical interventions. This means that neuroimaging and neurophysiological methods can be used as biomarkers-to make a prognosis of the course of stroke recovery and define patients with great potential of improvement after treatment. This approach is most likely to lead to novel rehabilitation strategies based on categorizing individuals for personalized treatment. In this review article, we introduce neuroimaging techniques dedicated to stroke recovery analysis with reference to angiogenesis and neuroplasticity processes. The most beneficial for personalized rehabilitation are multimodal panels of stroke recovery biomarkers, including neuroimaging and neurophysiological, genetic-molecular and clinical scales.

7.
Pol J Radiol ; 86: e564-e573, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34820033

RESUMO

PURPOSE: To assess the prevalence of the neuroradiological indices of cerebral small vessel disease (CSVD) in patients with severe aortic valve stenosis (AS) in magnetic resonance imaging (MRI). MATERIAL AND METHODS: 34 patients (age 60-90 years, 17 women and 17 men) with severe AS and 50 healthy controls (age 61-85 years, 29 women and 21 men) underwent MRI brain examinations, which were analysed for the neuroradiological indices of CSVD: hyperintensities in periventricular white matter (PVWM) and deep white matter (DWM), enlarged perivascular spaces (ePVS), lacunar strokes, and cerebral microbleeds (CMBs). RESULTS: PVWM hyperintensities were found in 46% of volunteers and was significantly lower (p = 0.027), corresponding to AS patients (80%), the density of lesions was higher in the AS group than in controls (p = 0.019). DWM hyperintensities were found more often in AS patients (76%) than in controls (66%) (p = 0.303), but the densities were similar in both groups. Lacunar strokes were found in 35% of AS patients and 16% of controls (p = 0.042). The average number of lacunar strokes per person was 0.9 in the AS group and 0.3 in the controls (p = 0.035). The AS group showed higher variance in the number of strokes: SD = 1.96 vs. SD = 1.06 in controls. Both prevalence and density of the ePVS and CMBs did not differ significantly between the groups. CONCLUSIONS: Neuroradiological indices of the vascular disease do not provide an unequivocal clue to the pathogenesis of CSVD in patients with severe AS. Most observations imply that CSVD is primarily a consequence of cerebral hypoperfusion caused by AS.

8.
Brain Sci ; 11(7)2021 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-34210078

RESUMO

The anterior cingulate cortex is considered to play a crucial role in cognitive and affective regulation. However, this area shows a high degree of morphological interindividual variability and asymmetry. It is especially true regarding the paracingulate sulcus and paracingulate gyrus (PCG). Since the reports described in the literature are mainly based on imaging techniques, the goal of this study was to verify the classification of the PCG based on anatomical material. Special attention was given to ambiguous cases. The PCG was absent in 26.4% of specimens. The gyrus was classified as present in 28.3% of cases. The prominent type of the PCG was observed in 37.7% of the total. Occasionally, the gyrus was well-developed and roughly only a few millimeters were missing for classifying the gyrus as prominent, as it ended slightly anterior the level of the VAC. The remaining four cases involved two inconclusive types. We observed that the callosomarginal artery ran within the cingulate sulcus and provided branches that crossed the PCG. Based on Klingler's dissection technique, we observed a close relationship of the PCG with the superior longitudinal fascicle. The awareness of the anatomical variability observed within the brain cortex is an essential starting point for in-depth research.

9.
Eur J Radiol Open ; 8: 100368, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34307788

RESUMO

The laryngoscopic examination remains the gold standard in the perioperative evaluation of the mobility of the vocal folds in patients with goiter. During the COVID-19 pandemic, many medical procedures, including laryngoscopy are optimized in terms of epidemiological safety. Therefore, it seems deeply justified to implement methods like i.e. ultrasound or MRI which can provide the diagnostic information usually obtained via laryngoscopic examination. AIM OF THE STUDY: To determine the value of dynamic MRI examination in the 1.5 T field in the assessment of the mobility of vocal folds in patients with goiter compared to healthy people and in relation to ultrasound examinations and routine laryngoscopy. MATERIALS AND METHODS: 35 healthy volunteers and 44 patients with goiter were subjected to videolaryngoscopy, dynamic examinations of the vocal folds during respiration and phonation using ultrasound and the MRI sequences: generic gradient echo (GRE) and true fast imaging with steady-state precession (TRUFI). The qualitative and quantitative data were analyzed, i.e. the angles of deviation from the midline of the vocal folds and the area of the right and left rima glottidis compartments. RESULTS: No statistically significant differences were found between the groups of healthy volunteers and patients with goiter in the values of the angles of deviation of the vocal folds with the use of ultrasound and two MRI dynamic sequences - GRE and TRUFI. There were also no statistically significant differences in the areas of the rima glottidis compartments between these two groups with the use of two MRI dynamic sequences - GRE and TRUFI. Among the analyzed parameters, the maximum size of each rima glottidis compartment was the only one to show features of sexual dimorphism and was significantly higher in men (GRE p < 0.001 and TRUFI p = 0.001). There was no correlation between the size of the minimum and maximum rima glottidis compartment and the total volume of the thyroid lobes in patients with goiter for the GRE and TRUFI sequences. CONCLUSIONS: MRI is a promising tool for the objective assessment of the mobility of the vocal folds in patients with goiter, as well as for the qualification for treatment and monitoring its effects. It is particularly important during an epidemiological emergency due to its safety compared to laryngoscopy. The presence of the goiter and its volume do not limit the possibility of performing dynamic imaging studies of the vocal folds and do not affect the surface area of the glottis.

10.
Neurol Neurochir Pol ; 54(5): 410-415, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33085075

RESUMO

Magnetic resonance imaging (MRI) is a widely used method for the diagnosis of multiple sclerosis that is essential for the detection and follow-up of the disease. OBJECTIVE: The Polish Medical Society of Radiology (PLTR) and the Polish Society of Neurology (PTN) present the second version of their recommendations for investigations routinely conducted in magnetic resonance imaging departments in patients with multiple sclerosis. This version includes new data and practical comments for electroradiology technologists and radiologists. The recommended protocol aims to improve the MRI procedure and, most importantly, to standardise the method of conducting scans in all MRI departments. This is crucial for the initial diagnostics necessary for establishing a diagnosis, as well as for MS patient monitoring, which directly translates into significant clinical decisions. INTRODUCTION: Multiple sclerosis (MS) is a chronic immune mediated inflammatory demyelinating disease of the central nervous system (CNS), the aetiology of which is still unknown. The nature of the disease lies in a CNS destruction process disseminated in time (DIT) and space (DIS). MRI detects focal lesions in the white and grey matter with high sensitivity (although with significantly lower specificity in the latter). It is also the best tool to assess brain atrophy in patients with MS in terms of grey matter volume (GMV) and white matter volume (WMV) as well as local atrophy (by measuring the volume of thalamus, corpus callosum, subcortical nuclei, and hippocampus) as parameters that correlate with disability progression and cognitive dysfunctions. Progress in MR techniques, as well as advances in postprocessing the obtained data, has driven the dynamic development of computer programs that allow for a more repeatable assessment of brain atrophy in both cross-sectional and longitudinal studies. MR imaging is unquestionably the best diagnostic tool available to follow up the course of the disease and support clinicians in choosing the most appropriate treatment strategy for their MS patient. However, to diagnose and follow up MS patients on the basis of MRI in accordance with the latest standards, the MRI study must adhere to certain quality criteria. Such criteria are the subject of this paper.


Assuntos
Esclerose Múltipla , Neurologia , Atrofia/patologia , Encéfalo/patologia , Estudos Transversais , Humanos , Imageamento por Ressonância Magnética , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/patologia , Polônia , Sociedades Médicas
11.
Pol J Radiol ; 85: e272-e276, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32612727

RESUMO

Magnetic resonance imaging (MRI) is a widely used method for the diagnosis of multiple sclerosis (MS) that is essential for the detection and follow-up of the disease. The Polish Medical Society of Radiology (PLTR) and the Polish Society of Neurology (PTN) present the second version of the recommendations for examinations routinely conducted in magnetic resonance imaging departments in patients with MS, which include new data and practical comments for electroradiology technicians and radiologists. The recommended protocol aims to improve the MRI procedure and, most importantly, to standardise the method of conducting scans in all MRI departments. This is crucial for the initial diagnostics that are necessary to establish a diagnosis as well as monitor patients with MS, which directly translates into significant clinical decisions. MS is a chronic idiopathic inflammatory demyelinating disease of the central nervous system (CNS), the aetiology of which is still unknown. The nature of the disease lies in the CNS destruction process disseminated in time and space. MRI detects focal lesions in the white and grey matter with high sensitivity (with significantly less specificity in the latter). It is also the best tool to assess brain atrophy in patients with MS in terms of grey matter volume and white matter volume as well as local atrophy (by measuring the volume of thalamus, corpus callosum, subcortical nuclei, hippocampus) as parameters that correlate with disability progression and cognitive dysfunctions. Progress in magnetic resonance techniques, as well as the abilities of postprocessing the obtained data, has become the basis for the dynamic development of computer programs that allow for a more repeatable assessment of brain atrophy in both cross-sectional and longitudinal studies. MRI is unquestionably the best diagnostic tool used to follow up the course of the disease and to treat patients with MS. However, to diagnose and follow up the patients with MS on the basis of MRI in accordance with the latest standards, an MRI study must meet certain quality criteria, which are the subject of this paper.

12.
Pol J Radiol ; 85: e118-e124, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32322317

RESUMO

PURPOSE: The management of patients with disorders of consciousness (DOC) constitutes a challenge for clinicians. CASE REPORT: We present the case of a 66-year-old man who developed coma with subsequent DOC after a severe traumatic brain injury. Behavioural assessment constitutes the gold standard in the evaluation of patients with DOC. In the case presented herein the neuropsychological findings were ambiguous, and the patient underwent functional magnetic resonance imaging (fMRI) to determine whether he was in a vegetative state or minimally conscious state. Three paradigms: passive, active, and resting state fMRI were used to study the brain activity in our patient. CONCLUSIONS: fMRI provided reliable evidence of preserved minimal consciousness. The neuroimaging techniques used in our patient were vital for his further treatment.

13.
BMC Cardiovasc Disord ; 19(1): 181, 2019 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-31362712

RESUMO

BACKGROUND: Considering vital role of renal arteries in many surgical procedures, diameter of renal arteries seems to be an important measure of kidney perfusion. In this study, we analyzed a new parameter, renal-aortic ratio (R-Ar) as an objective measure of the renal artery diameter. METHOD: The study included CT angiographic images from 254 patients (129 women and 125 men). R-Ar was calculated by dividing the diameter of the main renal artery for each kidney by the aortic diameter. RESULTS: R-Ar values for the whole study group ranged between 0.0863 and 0.5083; the ranges of R-Ar values for women and men patients were 0.1150-0.5083 and 0.0863-0.4449, respectively. In 412 cases (81.10%), the kidney was supplied by a single renal artery (RA variant) and in 96 (18.90%) by more than one artery (sRA variant). A significant difference was found in R-Ar values for RA and sRA variants (p = 0.0008). When the anatomical variant of renal perfusion was not considered on statistical analysis, a significant difference was found between the R-Ar values for women and men (p = 0.0259). No statistically significant difference was observed in R-Ar values for the right and left kidneys (p = 0.3123). Spearman's coefficient of rank correlation between patient age and renal-aortic ratio values for the whole study group equaled - 0.36. CONCLUSION: The analysis of the renal-aortic ratio values demonstrated that the diameter of renal arteries depended primarily on their number, and the relative diameter of renal arteries in women was larger than in men.


Assuntos
Aorta/diagnóstico por imagem , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Artéria Renal/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores Sexuais , Adulto Jovem
14.
PLoS One ; 14(6): e0218885, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31246998

RESUMO

BACKGROUND: Typically, cervical vertebrae display bifid spinous processes. Nevertheless, this feature may vary both between subjects and even within the vertebrae of the same individual. Although such variation can be important in archaeological research, anthropological studies and forensic medicine, it has not so far been the subject of any detailed studies. MATERIAL AND METHODS: An analysis of 200 cervical spine CT examinations was performed. The morphology of the spinous process was evaluated, and new anthropometric parameters were selected to allow a more precise quantitative analysis of the degree of bifidity. RESULTS: The spinous process base (i.e. the part of the spinous process which was not bifid) was significantly longer in CII and CVII than in the other vertebrae. The spinous process branches (bifid elements) were significantly longer in CVI and CVII than in the other vertebrae. The angle between the branches was significantly sharper in CII and CVII than in CIII-CVI, on the right side, and CIII-CV, on the left side. On the right side, the branching coefficient (degree of branch development) was significantly higher for CII and significantly lower for CVI-CVII than for the other vertebrae. On the left side, the coefficient was significantly higher for CII and CIV, and significantly lower for CVI-CVII, compared to the other vertebrae. CONCLUSION: Our findings highlight new objective parameters of morphological variability in the spinous processes of the cervical spine. They can form the basis of a new detailed differentiation of vertebrae and can represent an independent determinant of anatomical variability in the cervical spine.


Assuntos
Vértebras Cervicais/anatomia & histologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Antropologia Física , Antropometria , Vértebras Cervicais/diagnóstico por imagem , Feminino , Medicina Legal , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
15.
Adv Respir Med ; 87(2): 110-113, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31038722

RESUMO

Post-traumatic arterio-bronchial fistula is a rare cause of life-threatening hemorrhage. We present a case of a ten-year-old patient with a post-traumatic subclavian artery pseudoaneurysm complicated by an arterio-bronchial fistula and occlusion of the subclavian artery. The patient was treated with a stent-graft. We present radiological images of the fistula and the evolution of the changes in subsequent follow-up examinations.


Assuntos
Falso Aneurisma/diagnóstico por imagem , Fístula Arteriovenosa/diagnóstico por imagem , Artéria Subclávia/diagnóstico por imagem , Falso Aneurisma/patologia , Falso Aneurisma/cirurgia , Arteriopatias Oclusivas/diagnóstico por imagem , Fístula Arteriovenosa/patologia , Fístula Arteriovenosa/cirurgia , Criança , Clavícula/lesões , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Artéria Subclávia/patologia , Artéria Subclávia/cirurgia , Tomografia Computadorizada por Raios X
16.
J Clin Med ; 8(4)2019 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-30959826

RESUMO

BACKGROUND: The most common renal fusion anomaly is horseshoe kidney (HSK), a condition associated with variable arterial blood supply. The aim of this study was to determine whether the height of origin of the renal artery determines its diameter and whether it differs from the mean diameter of the renal arteries of normal kidneys (NK). METHODS: Computer tomography angiography (CTA) studies of 336 patients (88 HSK and 248 NK) were obtained in a search of renal arteries; these were than classified into four groups according to height of its origin: Group I, branching from the aorta superior to the inferior mesenteric artery (IMA); Group II, branching from the aorta below the IMA; Group III, branching from the iliac artery; and Group IV, originating from the internal and external iliac artery. RESULTS: The HSK group included 398 arteries (mean diameter 4.30 mm) and the NK group 598 (5.52 mm) (p < 0.0001). In the HSK group, the mean diameters according to groups were: Group I, 4.54 mm; Group II, 4.28 mm; Group III, 3.41 mm; and Group IV, 3.43 mm. Statistically significant differences were found between arteries originating from the aorta and arteries branching from the iliac arteries (p < 0.0001). In the NK group, the corresponding values were: Group I, 5.53 mm; and Group II, 4.45 mm. The number of arteries supplying the HSK wider than 3.0 mm were: Group I, 83.0%; Group II, 82.4%; Group III, 68.4%; and Group IV, 66.6%. CONCLUSIONS: The renal arteries of the HSK branch from their parental vessels at lower levels and have smaller diameters than those of NK.

17.
Arch Med Sci ; 15(2): 376-384, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30899290

RESUMO

INTRODUCTION: Despite the fact that cardiovascular magnetic resonance (CMR) with late gadolinium enhancement (LGE) is a proven method for detecting myocardial fibrosis, there is a need for new and reliable serological biomarkers. Circulating miRNAs could be a practical and attractive alternative. The purpose of the study was to assess the miRNAs well established in myocardial fibrosis - miR-21, miR-29a, miR-30d and miR-133a - in the plasma of patients with left ventricular non-compaction (LVNC) that have areas of LGE assessed by CMR. MATERIAL AND METHODS: We prospectively enrolled 13 adult patients (9 males and 4 females; mean age: 39 ±11.7 years) considered to meet standard CMR criteria for LVNC and 10 healthy age- and sex-matched subjects. All LVNC patients and control subjects underwent CMR examination and the measurement of peripheral plasma levels of 4 miRNAs: miR-21, miR-29a, miR-30d and miR-133a. RESULTS: The LGE was present in 9 of the 13 (69.2%) LVNC patients, and most often located in the ventricular septum. Compared with LGE-negative patients, LGE-positive patients had significantly lower LVEF (28.3 ±13.3% vs. 53.5 ±14.9%, p = 0.0113) and greater LV end-diastolic diameter (67.8 ±9.5 mm vs. 57 ±2.2 mm, p = 0.01). Significant up-regulation of all 4 miRNAs was observed among LGE-positive patients vs. LGE-negative patients: miR-21 (p = 0.007), miR-29a (p = 0.0001), miR-30d (p = 0.001) and miR-133a (p = 0.0003). CONCLUSIONS: The up-regulation of miR-21, miR-29a, miR-30d and miR-133a indicates the presence of LGE in LVNC patients, and therefore they may serve as potential biomarkers for myocardial fibrosis.

18.
Pol J Radiol ; 84: e368-e374, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31969952

RESUMO

PURPOSE: To verify the value of dynamic magnetic resonance imaging (MRI) sequences, fast field echo (FFE), and balanced gradient echo (true fast imaging with steady-state free precession - TRUFI) in the evaluation of vocal fold mobility in healthy volunteers, against ultrasound examination (US) as the reference test. MATERIAL AND METHODS: Vocal fold mobility in 35 healthy volunteers (age 20-59 years, 20 women and 15 men) with no history of laryngeal disorders and neck surgeries was determined by means of US and MRI during normal breathing and phonation of the "hiiii" sound. US images were used to determine the glottic angles. During MRI two dynamic sequences, fast field echo and balanced gradient echo, were applied to determine the minimum and maximum values of the glottic angles, along with the rima glottidis area, separately for the right and left compartments. Due to differences in larynx anatomy, the abovementioned parameters were analysed separately for women and men. RESULTS: No significant differences were observed between the glottic angle values obtained during US and dynamic MRI (FFE and TRUFI sequences). Regardless of the dynamic MRI sequence used, a positive correlation was found between the maximum values of glottic angle and the rima glottidis area. This correlation was strong and statistically significant among men, but not in women. CONCLUSIONS: Dynamic MRI of vocal folds using FFE and TRUFI sequence is an accurate method for the objective evaluation of rima glottidis width.

19.
Neurol Neurochir Pol ; 52(6): 638-642, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30447859

RESUMO

Magnetic resonance imaging is widely used in diagnosing multiple sclerosis as a basic method for detecting and monitoring the disease. INTRODUCTION: Polish Medical Society of Radiology presents the second version of the recommendations for the routinely conducted MRI in multiple sclerosis, which include new data and practical remarks for radiographers and radiologists. The recommended protocol aims to improve the imaging procedure and, most importantly, to standardize conducting MRI scans in all MRI departments. This is crucial for monitoring the patients with MS, which directly contributes to essential clinical decisions. AIM OF THE GUIDELINES: Multiple sclerosis (MS) is a chronic inflammatory demyelinating and degenerative disease of the central nervous system (CNS) with its etiology still unknown. The fundamental requirement of the disease is the CNS destruction process disseminated in time (DIT) and space (DIS). MR imaging detects focal lesions in white and gray matter with high sensitivity and is the best way to assess brain atrophy in MS patients. It is unquestionably the best diagnostic tool to follow-up the clinical course of the disease and treatment of MS patients. However, to achieve a diagnosis based on MRI scans, and follow-up MS patients according to the latest standards, an MRI scan has to meet certain quality criteria that are the subject of this work.


Assuntos
Esclerose Múltipla , Humanos , Imageamento por Ressonância Magnética , Esclerose Múltipla/diagnóstico por imagem , Polônia , Radiografia , Sociedades Médicas
20.
Wideochir Inne Tech Maloinwazyjne ; 13(1): 116-121, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29651329

RESUMO

Preoperative visualization of the Adamkiewicz artery - the vessel which is to a great extent responsible for supplying blood to the medullary cone - is an important step which must be taken before initiating restorative procedures in the aorta. We present a case of a 67-year-old patient who underwent an intravascular stent-graft implantation procedure, due to clinical signs of abdominal aortic aneurysm. Routine pre-operative computed tomography examination failed to demonstrate the Adamkiewicz artery. On the second day after the surgery, as a result of unexpected clinical deterioration, an magnetic resonance imaging examination of the lumbar spine was carried out. Based on the magnetic resonance imaging images and clinical manifestations the diagnosis of ischaemia of the medullary cone was made. In our work we also present a deep analysis of the anatomy of small-sized vessels supplying blood to the spinal cord and discuss effective techniques which enable visualization of the Adamkiewicz artery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...