Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Vet Parasitol ; 244: 1-6, 2017 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-28917298

RESUMO

Bovine cysticercosis (BCC), caused by the helminth Taenia saginata, is currently diagnosed solely by official meat inspection (MI) based on macroscopic detection of viable cysticerci or typical lesions of degenerated larvae. MI has a known low sensitivity (<16%), leading to a large proportion of infected cattle carcasses entering the human food chain and posing a risk to public health. Prevalence in Belgium based on MI results is estimated at around 0.22%. Due to the low sensitivity of MI, alternative techniques to detect BCC should be considered. This study evaluates MI, MI with additional incisions in the heart, specific antibody detection against excretory/secretory (E/S) in the Ab-ELISA and circulating antigens in the B158/B60 Ag-ELISA on 715 (101 MI-positive and 614 MI-negative) samples collected from carcasses at slaughterhouses in Belgium. Full dissection of the predilection sites was considered the reference test. During the study, mostly carcasses with (very) light infections were detected containing predominantly degenerated or calcified cysticerci and only few viable cysticerci. Dissection of the predilection sites detected 144 (23%) additional infections in the 614 MI-negative carcasses. When sequentially performing first the dissection of the predilection sites, followed by the Ag-ELISA and the Ab-ELISA, an additional 36% of MI-negative carcasses were found positive for BCC, resulting in a prevalence very much higher than the above mentioned 0.22%. The B158/B60 Ag-ELISA showed a sensitivity of 40% for the detection of carcasses containing viable cysticerci and a specificity of 100%, and detected 70 positive carcasses of which only 14 had been identified as positive during MI. If Ag-ELISA were implemented as a detection technique for BCC in the slaughterhouses, many infected carcasses would still not be detected due to the sensitivity of 40%. But as sensitivity increases with increasing number of cysticerci in the carcass, the infected carcasses passing inspection will be the ones containing only a few viable cysticerci and thus posing a smaller food safety problem. Ag-ELISA is preferred over the ES Ab-ELISA in this study, which had a sensitivity of 13.3% and a specificity of 91.7% in a population with overall low infection burdens.


Assuntos
Anticorpos Anti-Helmínticos/imunologia , Antígenos de Helmintos/imunologia , Doenças dos Bovinos/epidemiologia , Cisticercose/veterinária , Ensaio de Imunoadsorção Enzimática/veterinária , Taenia saginata/imunologia , Matadouros , Animais , Bovinos , Doenças dos Bovinos/parasitologia , Cisticercose/epidemiologia , Cisticercose/parasitologia , Cysticercus , Inocuidade dos Alimentos , Carne Vermelha/normas , Sensibilidade e Especificidade , Taenia saginata/genética , Taenia saginata/isolamento & purificação
2.
Vet Parasitol ; 227: 69-72, 2016 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-27523940

RESUMO

The monoclonal antibody-based circulating antigen detecting ELISA (B158/B60 Ag-ELISA) has been used elaborately in several studies for the diagnosis of human, bovine and porcine cysticercosis. Interpretation of test results requires a good knowledge of the test characteristics, including the repeatability and the effect of the borders of the ELISA plates. Repeatability was tested for 4 antigen-negative and 5 antigen-positive reference bovine serum samples by calculating the Percentage Coefficient of Variation (%CV) within and between plates, within and between runs, overall, for two batches of monoclonal antibodies and by 2 laboratory technicians. All CV values obtained were below 20% (except one: 24.45%), which indicates a good repeatability and a negligible technician error. The value of 24.45% for indicating the variability between batches of monoclonal antibodies for one positive sample is still acceptable for repeatability measures. Border effects were determined by calculating the %CV values between the inner and outer wells of one plate for 2 positive serum samples. Variability is a little more present in the outer wells but this effect is very small and no significant border effect was found.


Assuntos
Antígenos de Helmintos/sangue , Doenças dos Bovinos/parasitologia , Ensaio de Imunoadsorção Enzimática/veterinária , Taenia saginata/metabolismo , Teníase/veterinária , Animais , Antígenos de Helmintos/isolamento & purificação , Bovinos , Doenças dos Bovinos/sangue , Doenças dos Bovinos/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Teníase/sangue , Teníase/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...