Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
J Thorac Imaging ; 38(2): 128-135, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36821381

RESUMO

PURPOSE: The Italian Registry of Contrast Material use in Cardiac Computed Tomography (iRCM-CCT) is a multicenter, multivendor, observational study on the use of contrast media (CM) in patients undergoing cardiac computed tomography (CCT). The aim of iRCM-CCT is to assess image quality and safety profile of intravenous CM compounds. MATERIALS AND METHODS: iRCM-CCT enrolled 1842 consecutive patients undergoing CCT (≥50 per site) at 20 cluster sites with the indication of suspected coronary artery disease. Demographic characteristics, CCT, and CM protocols, clinical indications, safety markers, radiation dose reports, qualitative (ie, poor vascular enhancement) and quantitative (ie, HU attenuation values) image parameters were recorded. A centralized coordinating center collected and assessed all image parameters. RESULTS: The cohort included 891 men and 951 women (age: 63±14 y, body mass index: 26±4 kg/m2) studied with ≥64 detector rows computed tomography scanners and different iodinated intravenous CM protocols and compounds (iodixanol, iopamidol, iohexol, iobitridol, iopromide, and iomeprol). The following vascular attenuation was reported: 504±147 HU in the aorta, 451±146 HU in the right coronary artery, 474±146 HU in the left main, 451±146 HU in the left anterior descending artery, and 441±149 HU in the circumflex artery. In 4% of cases the image quality was not satisfactory due to poor enhancement. The following adverse reactions to CM were recorded: 6 (0.3%) extravasations and 17 (0.9%) reactions (11 mild, 4 moderate, 2 severe). CONCLUSIONS: In a multicenter registry on CM use during CCT the prevalence of CM-related adverse reactions was very low. The appropriate use of CM is a major determinant of image quality.


Assuntos
Meios de Contraste , Doença da Artéria Coronariana , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Tomografia Computadorizada por Raios X/métodos , Angiografia Coronária/métodos , Sistema de Registros
5.
Eur J Radiol ; 101: 1-7, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29571781

RESUMO

OBJECTIVE: To investigate the influence of different CT reconstruction parameters on coronary artery calcium scoring (CACS) values and reclassification of predicted cardiovascular (CV) risk. METHODS: CACS was evaluated in 113 patients undergoing ECG-gated 64-slice CT. Reference CACS protocol included standard kernel filter (B35f) with slice thickness/increment of 3/1.5 mm, and field-of-view (FOV) of 150-180 mm. Influence of different image reconstruction algorithms (reconstructed slice thickness/increment 2.0/1.0-1.5/0.8-3.0/2.0-3.0/3.0 mm; slice kernel B30f-B45f; FOV 200-250 mm) on Agatston score was assessed by Bland-Altman plots and concordance correlation coefficient (CCC) analysis. Classification of CV risk was based on the Mayo Clinic classification. RESULTS: Different CACS reconstruction parameters showed overall good accuracy and precision when compared with reference protocol. Protocols with larger FOV, thinner slices and sharper kernels were associated with significant CV risk reclassification. Use of kernel B45f showed a moderate positive correlation with reference CACS protocol (Agatston CCC = 0.67), and yielded significantly higher CACS values (p < .05). Reconstruction parameters using B30f or B45f kernels, 250 mm FOV, or slice thickness/increment of 2.0/1.0 mm or 1.5/0.8 mm, were associated with significant reclassification of CV risk (p < .05). CONCLUSIONS: Kernel, FOV, slice thickness and increment are major determinants of accuracy and precision of CACS measurement. Despite high agreement and overall good correlation of different reconstruction protocols, thinner slices thickness and increment, and sharper kernels were associated with significant upward reclassification of CV risk. Larger FOV determined both upward and downward reclassification of CV risk.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Calcificação Vascular/diagnóstico por imagem , Idoso , Algoritmos , Doenças Cardiovasculares/prevenção & controle , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco/métodos , Fatores de Risco
7.
Radiol Med ; 120(12): 1122-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25981381

RESUMO

PURPOSE: The aim of the study was to evaluate the prevalence of collateral findings detected in computed tomography coronary angiography (CTCA) in a multi-center registry. MATERIALS AND METHODS: We performed a retrospective review of 4303 patients (2719 males, mean age 60.3 ± 10.2 years) undergoing 64-slice CTCA for suspected or known coronary artery disease (CAD) at various academic institutions between 01/2006 and 09/2010. Collateral findings were recorded and scored as: non-significant (no signs of relevant pathology, not necessary to be reported), significant (clear signs of pathology, mandatory to be reported), or major (remarkable pathology, mandatory to be reported and further investigated). RESULTS: We detected 6886 non-cardiac findings (1.6 non cardiac finding per patient). Considering all centers, only 865/4303 (20.1 %) patients were completely without any additional finding. Overall, 2095 (30.4 %) non-significant, 4486 (65.2 %) significant, and 305 (4.4 %) major findings were detected. Among major findings, primary lung cancer was reported in 21 cases. In every center, most prevalent significant findings were mediastinal lymph nodes >1 cm. In 256 patients, collateral findings were clinically more relevant than coexisting CAD and justified the symptoms of patients. CONCLUSIONS: The prevalence of significant and major collateral findings in CTCA is high. Radiologists should carefully evaluate the entire scan volume in each patient.


Assuntos
Angiografia Coronária , Tomografia Computadorizada por Raios X , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
8.
Radiol Med ; 118(7): 1149-56, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23716280

RESUMO

Three separate venous systems drain the blood returning from the heart walls. These veins are characterised by remarkable variability in terms of frequency, size and course. The knowledge of cardiac venous anatomy is of primary importance during interventional cardiac procedures that require catheterisation of cardiac veins. Some anatomical variants may hinder or contraindicate access to target veins. Coronary angiography (CA) with multidetector computed tomography (MDCT-CA) and multiplanar reformations (MPR), maximum intensity projection (MIP) and 3D reconstructions provides noninvasive visualisation of normal cardiac veins and anatomical variants. The purpose of this pictorial review is to describe by MDCT-CA the anatomy and main variants of the cardiac venous system.


Assuntos
Angiografia Coronária , Anomalias dos Vasos Coronários/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Flebografia/métodos , Humanos , Imageamento Tridimensional , Valores de Referência
9.
Radiol Med ; 118(8): 1294-308, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23716289

RESUMO

PURPOSE: This study evaluated the incremental value and cost-effectiveness ratio of introducing coronary angiography (CA) with multidetector computed tomography (MDCT-CA) in the diagnostic management of patients with suspected coronary artery disease (CAD) compared with the traditional diagnostic workup. MATERIAL AND METHODS: Five hundred and fifty consecutive patients who underwent MDCT-CA between January 2009 and June 2011 were considered. Patients with atypical chest pain and suspected obstructive CAD were directed to one of two diagnostic pathways: the traditional protocol (examination, stress test, CA) and the current protocol (examination, stress test, MDCT-CA, and CA, if necessary). The costs of each protocol and for the individual method were calculated. Based on the results, the cost-effectiveness ratio of the two diagnostic pathways was compared. A third, modified, diagnostic pathway has been proposed with its relative cost-effectiveness ratio (examination, MDCT-CA, stress test, and CA, if necessary). RESULTS: Stress test vs. MDCT-CA had an accuracy of 66%, a sensitivity and specificity of 21% and 87%, respectively, and a positive (PPV) and negative (NPV) predictive value of 40% and 70%, respectively. Comparison between conventional CA (CCA) and MDCT-CA showed a sensitivity and specificity of 92% and 89%, respectively, a PPV and NPV of 89%, and an accuracy of 92%. The traditional protocol has higher costs than the second protocol: 1,645 euro against 322 euro (mean), but it shows a better cost-effectiveness ratio. The new proposed protocol has lower costs, mean 261 euro, with a better costeffectiveness ratio than the traditional protocol. CONCLUSIONS: The diagnostic protocol for patients with suspected CAD has been modified by the introduction of MDCT-CA. Our study confirms the greater diagnostic performance of MDCT-CA compared with stress test and its similar accuracy to CCA. The use of MDCT-CA to select patients for CCA has a favourable cost-effectiveness profile.


Assuntos
Angiografia Coronária/economia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/economia , Tomografia Computadorizada Multidetectores/economia , Idoso , Análise Custo-Benefício , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Risco , Sensibilidade e Especificidade
10.
Radiol Med ; 118(8): 1281-93, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23716291

RESUMO

PURPOSE: Coronary angiography using multidetector computed tomography (MDCT-CA) is a recent technique for the nonivasive study of coronary arteries. This study assessed the diagnostic accuracy of coronary artery stenosis evaluation obtained by three readers at different levels of training or at different points of the learning curve proposed by the international guidelines. MATERIALS AND METHODS: Three radiologists in training with different levels of experience in MDCT-CA scored 50 cases at various time points of the learning curve: baseline, 4 weeks, 8 weeks and 6 months. The trainee radiologists evaluated the degree of stenosis on each coronary segment, and overall accuracy was calculated on a per-segment, pervessel and per-patient basis. RESULTS: All readers improved analysis accuracy per segment (range, 73-90%); sensitivity reached 45% per segment, 84% per vessel and 93% per patient; specificity was 99% per segment and vessel and 98% per patient. Positive and negative predictive values increased to 94% and 92%, respectively. CONCLUSIONS: Although all readers improved in diagnostic performance with growing experience with MDCT-CA, a longer training period may be necessary to achieve adequate levels of expertise in MDCT-CA to be able to perform as independent readers.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Competência Clínica , Ponte de Artéria Coronária , Estenose Coronária/cirurgia , Feminino , Humanos , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Stents , Grau de Desobstrução Vascular
11.
Am J Emerg Med ; 31(2): 450.e3-4, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23000322

RESUMO

The main coronary artery variants and anomalies are completely asymptomatic and are discovered incidentally or as they rise symptoms. Multidetector computed tomography coronary angiography represents an excellent technique for noninvasive assessment of the coronary tree mainly because of the multiplanar imaging modalities of computed tomography. Thin collimation permits to depict thin vessels such as the sinus node artery, as reported in this case. In this brief report, we describe a case of a rare anomaly of termination the coronaries, a double fistula between the sinus node artery, and the right atrium in a patient with atypical chest pain.


Assuntos
Dor no Peito/etiologia , Angiografia Coronária/métodos , Anomalias dos Vasos Coronários/diagnóstico por imagem , Átrios do Coração/anormalidades , Tomografia Computadorizada Multidetectores , Fístula Vascular/diagnóstico por imagem , Idoso , Anomalias dos Vasos Coronários/complicações , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Fístula Vascular/complicações , Fístula Vascular/congênito
12.
Eur J Radiol ; 81(11): 3262-9, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22480417

RESUMO

PURPOSE: Coronary venous anatomy is of primary importance when implanting a cardiac resynchronization therapy device, besides, the coronary sinus can be differently enlarged depending on chronic heart failure. The aim of this study is to evaluate the usefulness of Coronary CTA in describing the coronary venous tree and in particular the coronary sinus and detecting main venous system variants. MATERIALS AND METHODS: 301 consecutive patients (196 ♂, mean age 63.74 years) studied for coronary artery disease with 64 slice Coronary CTA were retrospectively examined. The acquisition protocol was the standard acquisition one used for coronary artery evaluation but the cardiac venous system were visualized. The cardiac venous system was depicted using 3D, MPR, cMPR and MIP post-processing reconstructions on an off-line workstation. For each patient image quality, presence and caliber of the coronary sinus (CS), great cardiac vein (GCV), middle vein (MV), anterior interventricular vein (AIV), lateral cardiac vein (LCV), posterior cardiac vein (PCV), small cardiac vein (SCV) and presence of variant of the normal anatomy were examined and recorded. RESULTS: CS, GCV, MV and AIV were visualized in 100% of the cases. The LCV was visualized in 255/301 (84%) patients, the PCV in 248/301 (83%) patients and the SCV in 69/301 (23%) patients. Mean diameter of the CS was 8.7 mm in 276/301 (91.7%) patients without chronic heart failure and 9.93 mm in 25/301 (8.3%) patients with chronic heart failure. CONCLUSIONS: Coronary CTA allows non invasive mapping of the cardiac venous system and may represent a useful presurgical tool for biventricular pacemaker devices implantation.


Assuntos
Algoritmos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Flebografia/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Pediatr Radiol ; 41(12): 1505-15, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22127682

RESUMO

Variants and congenital anomalies of the coronary arteries are usually asymptomatic, but may present with severe chest pain or cardiac arrest. The introduction of multidetector CT coronary angiography (MDCT-CA) allows the detection of significant coronary artery stenosis. Improved performance with isotropic spatial resolution and higher temporal resolution provides a valid alternative to conventional coronary angiography (CCA) in many patients. MDCT-CA is now considered the ideal tool for three-dimensional visualization of the complex and tortuous anatomy of the coronary arteries. With multiplanar and volume-rendered reconstructions, MDCT-CA may even outperform CCA in determining the relative position of vessels, thus providing a better view of the coronary vascular anatomy. The purpose of this review is to describe the normal anatomy of the coronary arteries and their main variants based on MDCT-CA with appropriate reconstructions.


Assuntos
Angiografia Coronária/métodos , Anomalias dos Vasos Coronários/diagnóstico , Vasos Coronários/patologia , Angiografia por Ressonância Magnética/métodos , Humanos
14.
J Comput Assist Tomogr ; 34(5): 652-9, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20861765

RESUMO

BACKGROUND: Multidetector computed tomography-coronary angiography allows quantification of coronary stenosis with a high level of accuracy; however, the inherent inaccuracy of visual score still remains. Computed quantitative vessel analysis systems (quantitative computed tomographic angiography [QCTA]) aim to overcome this limitation. The aim of our study was to evaluate the accuracy of QCTA in comparison with quantitative coronary angiography (QCA) and visual score using the QCA. MATERIALS AND METHODS: Two operators visually scored 30 consecutive patients referred for multidetector computed tomography-coronary angiography to assess stenotic segments according to a modified 17-segment American Heart Association classification model. Coronary angiography was performed within 1 week. The degree of stenosis was classified as 0%, lower than 20% (wall irregularities), lower than 50% (without significant disease), and higher than 50% (significant disease). Each segment was then analyzed using electronic calipers of the QCTA system. Data were compared with QCA results. Each segment was finally classified as fibrofatty, mixed, and calcified. Comparisons between QCTA results, visual score, and QCA were performed by means of Spearman rank correlation. Interobserver variability is calculated using κ statistics. RESULTS: From a total of 870 segments, 69 were diseased. Interobserver agreement between the 2 operators resulted very high (κ = 0.97). A good correlation was found between visual score and QCA (ρ = 0.932, P < 0.0001) and between visual score and QCTA (ρ = 0.845, P < 0.0001). A moderate correlation was found between QCTA and QCA (ρ = 0.810, P < 0.0001). CONCLUSIONS: The accuracy of QCTA is comparable with that of QCA and visual score especially in noncalcified vessels. Editing of the vessel contours in case of calcified vessels is helpful in correctly estimating the right percentage of stenosis.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Calcinose/diagnóstico por imagem , Estenose Coronária/patologia , Humanos , Reconhecimento Automatizado de Padrão , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Estatísticas não Paramétricas
15.
AJR Am J Roentgenol ; 193(6): 1691-5, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19933666

RESUMO

OBJECTIVE: The purpose of this study was to assess the accuracy and short-term complication rate of ultrasound-guided fine-needle aspiration cytologic sampling of focal pancreatic lesions. MATERIALS AND METHODS: We reviewed 545 consecutive ultrasound-guided fine-needle aspiration cytologic sampling procedures for focal pancreatic lesions from January 2004 through June 2008. The procedures were performed with a 20- or 21-gauge needle. The onsite cytopathologist evaluated the appropriateness of the sample and made a diagnosis. We reviewed the final diagnosis and the radiologic and medical records of all patients for onset of complications during or within 7 days of the procedure. RESULTS: The study sample included 262 women and 283 men (mean age, 62 years; range, 25-86 years). The head or uncinate process of the pancreas was the location of 63.0% of the lesions, and 35.2% of the lesions were located in the body or tail of the pancreas. The site of 10 lesions (1.8%) was not specified. Sampling was diagnostic in 509 of the 545 cases (93.4%). Excluding the 36 nondiagnostic samples, ultrasound-guided fine-needle aspiration cytologic sampling had 99.4% sensitivity, 100% specificity, and 99.4% accuracy. In 537 of the 545 cases (98.5%), the procedure was uneventful. In two cases, abdominal fluid was found after the procedure that was not present before the procedure. Six patients experienced postprocedural pain without abnormal findings at subsequent imaging. No major complications occurred. CONCLUSION: Ultrasound-guided cytologic sampling is safe and accurate for the diagnosis and planning of management of focal pancreatic lesions. With a cytologist on site, the rate of acquisition of samples adequate for diagnosis is high, reducing the need for patient recall.


Assuntos
Biópsia por Agulha Fina/métodos , Pâncreas/patologia , Ultrassonografia de Intervenção , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pâncreas/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade
16.
Radiology ; 251(2): 359-68, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19401570

RESUMO

PURPOSE: To prospectively evaluate the effect of experience with coronary computed tomographic (CT) angiography on the capability to detect coronary stenoses of 50% or more. MATERIALS AND METHODS: The institutional review board approved the study protocol. All patients gave consent to undergo CT angiography before conventional coronary angiography after being informed of the additional radiation dose. They also consented to the use of their data for future research. Three radiologists and one cardiologist inexperienced with coronary CT angiography attended this institution's cardiac CT unit for a 1-year fellowship. Fellows were involved in the acquisition and reading of 12-15 coronary CT angiograms per week (about 600 per year). To assess the progression in diagnostic performance, fellows (readers) independently read 50 CT angiographic test cases in patients who also underwent conventional coronary angiography. Cases were repeatedly assigned in random order at baseline and at 4, 8, 26, and 52 weeks. The same cases were examined by two experts in consensus. Sensitivity, specificity, and diagnostic odds ratios (DORs) were calculated and compared with conventional coronary angiography as the reference standard. RESULTS: Respective reader ranges for sensitivity, specificity, and DOR were 33%-72%, 70%-94%, and 3.8-8.1 at baseline; 43%-80%, 71%-88%, and 8.8-15.2 after 6 months; and 66%-75%, 87%-92%, and 14.7-25.8 after 1 year. For expert physicians, respective results were 95%, 93%, and 255.9. Between baseline and 6 months, readers 1-3 showed nonsignificantly improved sensitivities, while specificities remained similar. Reader 4 showed significantly improved specificity, while sensitivity remained similar; all readers nonsignificantly improved DORs. Between baseline and 1 year: readers 1 and 2 significantly improved sensitivity but not specificity; reader 4 significantly improved specificity but not sensitivity; readers 1, 2, and 4 improved DOR significantly; reader 3 nonsignificantly improved sensitivity, specificity, and DOR. CONCLUSION: Increasing experience with coronary CT angiography improved the diagnostic performance of inexperienced physicians. However, acquiring expertise in coronary CT angiography was slow and may take more than 1 year.


Assuntos
Angiografia Coronária/estatística & dados numéricos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/epidemiologia , Internato e Residência/estatística & dados numéricos , Competência Profissional/estatística & dados numéricos , Radiologia/educação , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Avaliação Educacional , Escolaridade , Humanos , Países Baixos , Variações Dependentes do Observador
17.
AJR Am J Roentgenol ; 192(2): 424-30, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19155405

RESUMO

OBJECTIVE: Diagnosis of malignancy and prognostic assessment continue to be problems in the management of nonfunctioning pancreatic endocrine tumors. Histologic examination is the reference standard. The aim of our study was to compare B-mode and contrast-enhanced sonographic findings regarding nonfunctioning pancreatic endocrine tumors. Signs of malignancy, such as Ki67 index and presence of hepatic metastasis, were considered. MATERIALS AND METHODS: We retrospectively reviewed the cases of 38 consecutively registered patients with nonfunctioning pancreatic endocrine tumors evaluated with B-mode and contrast-enhanced sonography and resected. At contrast-enhanced sonography all lesions were divided into hypovascular lesions and isovascular or hypervascular lesions. On the basis of homogeneity of enhancement, lesions were classified as homogeneous and inhomogeneous. During the late phase of contrast enhancement, all solid focal hypoechoic liver lesions detected at contrast-enhanced sonography were considered hepatic metastatic lesions. Among pathologic data, grading, mitotic index, and Ki67 index were evaluated. Spearman's test was used to compare contrast-enhanced sonographic enhancement pattern with pathologic grade. RESULTS: In the arterial phase, 24 of 38 nonfunctioning pancreatic endocrine tumors (63.1%) were hypervascular, seven (18.4%) were isovascular, and seven (18.4%) were hypovascular. Positive correlation was found between contrast-enhanced sonographic findings and Ki67 index (r(s) = 0.62; p < 0.0001). The difference between contrast-enhanced and B-mode sonography in the diagnosis of nonfunctioning pancreatic endocrine tumors was statistically significant (p < 0.05). Use of contrast-enhanced sonography increased diagnostic confidence in the detection of hepatic metastasis. The areas under the receiver operating characteristic curves were 0.916 for B-mode sonography and 1.000 for contrast-enhanced sonography (p < 0.05). There was moderate positive correlation between contrast-enhanced sonographic enhancement pattern and the presence of hepatic metastasis at diagnosis (r(s) = 0.46; p = 0.004) and between Ki67 index and the presence of hepatic metastasis (r(s) = 0.48; p = 0.0022). CONCLUSION: The contrast-enhanced sonographic enhancement pattern of nonfunctioning pancreatic endocrine tumors has a positive correlation with Ki67 index, which is considered the most reliable independent predictor of the presence of malignancy.


Assuntos
Tumores Neuroendócrinos/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/análise , Meios de Contraste , Feminino , Humanos , Antígeno Ki-67/análise , Masculino , Pessoa de Meia-Idade , Tumores Neuroendócrinos/patologia , Neoplasias Pancreáticas/patologia , Fosfolipídeos , Prognóstico , Curva ROC , Estudos Retrospectivos , Hexafluoreto de Enxofre
18.
J Ultrasound Med ; 27(12): 1727-33, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19022998

RESUMO

OBJECTIVE: Thyroid volume quantification is an important parameter for radiotherapy dosing in cases of major thyroid diseases such as thyroiditis and carcinoma. In clinical practice, this calculation is performed by means of ultrasonography on the basis of an ellipsoid formula obtained from the 3 axes. The aim of our study was to compare the accuracy of volume calculation between B-mode ultrasonography and volumetric ultrasonography (VUS). METHODS: Between April and May 2007, 27 consecutive patients selected for thyroidectomy were prospectively evaluated. One expert ultrasound operator calculated each thyroid volume with standard B-mode ultrasonography on the basis of the 3 axes of each lobe, and then the patients were analyzed with an offline workstation equipped with volumetric probes (VUS). On the offline workstation, 2 separate blinded operators (VUS1 and VUS2) calculated the thyroid volume with virtual organ computer-aided analysis. Data acquired were then compared with pathologic anatomy (PA). RESULTS: The mean time for B-mode analysis was 6 minutes, whereas VUS analysis needed a mean time of 16.5 minutes. Interobserver variability between the median VUS1 and VUS2 measurements was 0.36 mL (interquartile range [IQR], -0.79 to 0.37 mL; P < .156). The median variability between B-mode ultrasonography and PA was -9.6 mL (IQR, -16.7 to 1.5 mL; P < .001), and that between VUS and PA was -2.87 mL (IQR, -11.97 to 9.51 mL; P = .019). The overall performance of B-mode ultrasonography in comparison with PA was -29.1% (IQR, -47.5% to -5.9%), and that of VUS in comparison with PA was -6.3% (IQR, -26.3 to 13.7%; P < .001). CONCLUSIONS: Volumetric ultrasonography is a valid tool that compares better with PA than does B-mode ultrasonography.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Doenças da Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Pancreas ; 37(3): 265-8, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18815547

RESUMO

UNLABELLED: To evaluate if contrast-enhanced ultrasonography (CEUS) improves the depiction of tumoral margins of pancreatic adenocarcinoma in relation to tumor enhancement, using pathology as criterion standard. METHODS: Two hundred forty-one patients affected by pancreatic ductal adenocarcinoma were investigated at CEUS with a second-generation contrast medium of sulfur-hexafluoride microbubbles. Sixty-seven (27.8%) of 241 tumors were resected. By consensus, 2 radiologists reviewed the CEUS examination results of the 67 tumors judging the enhancement as low (hypovascular lesions, hypoechoic tothe adjacent parenchyma) or high (iso- or hypervascular lesions, iso- or hyperechoic to the adjacent parenchyma). The resected tumors were evaluated at pathology for the presence of positive neoplastic (R+) or negative neoplastic (R-) resected margins. RESULTS: Of the 67 resected tumors, 35 (52.3%) were R-, whereas 32 (47.7%) were R+. Moreover, at CEUS, of the 67 resected tumors, 43 (64.1%) were hypovascular with low enhancement and 24 (35.8%) were iso-hypervascular with high enhancement. In the R- group, 27 (77.1%) of 35 tumors were hypovascular. In the R+ group, 16 (50%) of 32 lesions were hypovascular. CONCLUSIONS: At CEUS the depiction of tumoral margins of pancreatic adenocarcinoma is more accurate in low enhancement than in high enhancement. The pattern of enhancement of pancreatic adenocarcinoma influences the depiction of tumoral margins at CEUS.


Assuntos
Carcinoma Ductal Pancreático/diagnóstico por imagem , Meios de Contraste , Pancreatectomia , Neoplasias Pancreáticas/diagnóstico por imagem , Hexafluoreto de Enxofre , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Ductal Pancreático/cirurgia , Feminino , Humanos , Masculino , Microbolhas , Pessoa de Meia-Idade , Neoplasias Pancreáticas/cirurgia , Valor Preditivo dos Testes , Estudos Retrospectivos , Ultrassonografia
20.
Urology ; 71(4): 755.e13-5, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18313108

RESUMO

Fibromuscular dysplasia is the most common cause of renovascular hypertension in young patients. It primarily involves the renal and carotid arteries, and it is less common in the coronary, iliac, and visceral arteries. Digital subtraction angiography is still the best investigation to determine the location, extent, and complications of renal artery involvement. However, currently, other imaging modalities such as ultrasonography, computed tomography, and magnetic resonance imaging can reveal these findings noninvasively. We present the case of a 43-year-old woman who presented with high blood pressure and headache. Imaging revealed fibromuscular dysplasia of the renal arteries and the superior mesentery artery.


Assuntos
Displasia Fibromuscular/diagnóstico , Artéria Mesentérica Superior , Artéria Renal , Adulto , Diagnóstico por Imagem , Feminino , Displasia Fibromuscular/terapia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA