Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 18844, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37914808

RESUMO

Drug development for mood disorders can greatly benefit from the development of robust, reliable, and objective biomarkers. The incorporation of smartphones and wearable devices in clinical trials provide a unique opportunity to monitor behavior in a non-invasive manner. The objective of this study is to identify the correlations between remotely monitored self-reported assessments and objectively measured activities with depression severity assessments often applied in clinical trials. 30 unipolar depressed patients and 29 age- and gender-matched healthy controls were enrolled in this study. Each participant's daily physiological, physical, and social activity were monitored using a smartphone-based application (CHDR MORE™) for 3 weeks continuously. Self-reported depression anxiety stress scale-21 (DASS-21) and positive and negative affect schedule (PANAS) were administered via smartphone weekly and daily respectively. The structured interview guide for the Hamilton depression scale and inventory of depressive symptomatology-clinical rated (SIGHD-IDSC) was administered in-clinic weekly. Nested cross-validated linear mixed-effects models were used to identify the correlation between the CHDR MORE™ features with the weekly in-clinic SIGHD-IDSC scores. The SIGHD-IDSC regression model demonstrated an explained variance (R2) of 0.80, and a Root Mean Square Error (RMSE) of ± 15 points. The SIGHD-IDSC total scores were positively correlated with the DASS and mean steps-per-minute, and negatively correlated with the travel duration. Unobtrusive, remotely monitored behavior and self-reported outcomes are correlated with depression severity. While these features cannot replace the SIGHD-IDSC for estimating depression severity, it can serve as a complementary approach for assessing depression and drug effects outside the clinic.


Assuntos
Transtorno Depressivo Maior , Aplicativos Móveis , Dispositivos Eletrônicos Vestíveis , Humanos , Smartphone , Autorrelato , Depressão/diagnóstico
2.
JMIR Form Res ; 7: e41178, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36920465

RESUMO

BACKGROUND: Facioscapulohumeral muscular dystrophy (FSHD) is a progressive neuromuscular disease. Its slow and variable progression makes the development of new treatments highly dependent on validated biomarkers that can quantify disease progression and response to drug interventions. OBJECTIVE: We aimed to build a tool that estimates FSHD clinical severity based on behavioral features captured using smartphone and remote sensor data. The adoption of remote monitoring tools, such as smartphones and wearables, would provide a novel opportunity for continuous, passive, and objective monitoring of FSHD symptom severity outside the clinic. METHODS: In total, 38 genetically confirmed patients with FSHD were enrolled. The FSHD Clinical Score and the Timed Up and Go (TUG) test were used to assess FSHD symptom severity at days 0 and 42. Remote sensor data were collected using an Android smartphone, Withings Steel HR+, Body+, and BPM Connect+ for 6 continuous weeks. We created 2 single-task regression models that estimated the FSHD Clinical Score and TUG separately. Further, we built 1 multitask regression model that estimated the 2 clinical assessments simultaneously. Further, we assessed how an increasingly incremental time window affected the model performance. To do so, we trained the models on an incrementally increasing time window (from day 1 until day 14) and evaluated the predictions of the clinical severity on the remaining 4 weeks of data. RESULTS: The single-task regression models achieved an R2 of 0.57 and 0.59 and a root-mean-square error (RMSE) of 2.09 and 1.66 when estimating FSHD Clinical Score and TUG, respectively. Time spent at a health-related location (such as a gym or hospital) and call duration were features that were predictive of both clinical assessments. The multitask model achieved an R2 of 0.66 and 0.81 and an RMSE of 1.97 and 1.61 for the FSHD Clinical Score and TUG, respectively, and therefore outperformed the single-task models in estimating clinical severity. The 3 most important features selected by the multitask model were light sleep duration, total steps per day, and mean steps per minute. Using an increasing time window (starting from day 1 to day 14) for the FSHD Clinical Score, TUG, and multitask estimation yielded an average R2 of 0.65, 0.79, and 0.76 and an average RMSE of 3.37, 2.05, and 4.37, respectively. CONCLUSIONS: We demonstrated that smartphone and remote sensor data could be used to estimate FSHD clinical severity and therefore complement the assessment of FSHD outside the clinic. In addition, our results illustrated that training the models on the first week of data allows for consistent and stable prediction of FSHD symptom severity. Longitudinal follow-up studies should be conducted to further validate the reliability and validity of the multitask model as a tool to monitor disease progression over a longer period. TRIAL REGISTRATION: ClinicalTrials.gov NCT04999735; https://www.clinicaltrials.gov/ct2/show/NCT04999735.

3.
JMIR Form Res ; 6(9): e31775, 2022 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-36098990

RESUMO

BACKGROUND: Facioscapulohumeral dystrophy (FSHD) is a progressive muscle dystrophy disorder leading to significant disability. Currently, FSHD symptom severity is assessed by clinical assessments such as the FSHD clinical score and the Timed Up-and-Go test. These assessments are limited in their ability to capture changes continuously and the full impact of the disease on patients' quality of life. Real-world data related to physical activity, sleep, and social behavior could potentially provide additional insight into the impact of the disease and might be useful in assessing treatment effects on aspects that are important contributors to the functioning and well-being of patients with FSHD. OBJECTIVE: This study investigated the feasibility of using smartphones and wearables to capture symptoms related to FSHD based on a continuous collection of multiple features, such as the number of steps, sleep, and app use. We also identified features that can be used to differentiate between patients with FSHD and non-FSHD controls. METHODS: In this exploratory noninterventional study, 58 participants (n=38, 66%, patients with FSHD and n=20, 34%, non-FSHD controls) were monitored using a smartphone monitoring app for 6 weeks. On the first and last day of the study period, clinicians assessed the participants' FSHD clinical score and Timed Up-and-Go test time. Participants installed the app on their Android smartphones, were given a smartwatch, and were instructed to measure their weight and blood pressure on a weekly basis using a scale and blood pressure monitor. The user experience and perceived burden of the app on participants' smartphones were assessed at 6 weeks using a questionnaire. With the data collected, we sought to identify the behavioral features that were most salient in distinguishing the 2 groups (patients with FSHD and non-FSHD controls) and the optimal time window to perform the classification. RESULTS: Overall, the participants stated that the app was well tolerated, but 67% (39/58) noticed a difference in battery life using all 6 weeks of data, we classified patients with FSHD and non-FSHD controls with 93% accuracy, 100% sensitivity, and 80% specificity. We found that the optimal time window for the classification is the first day of data collection and the first week of data collection, which yielded an accuracy, sensitivity, and specificity of 95.8%, 100%, and 94.4%, respectively. Features relating to smartphone acceleration, app use, location, physical activity, sleep, and call behavior were the most salient features for the classification. CONCLUSIONS: Remotely monitored data collection allowed for the collection of daily activity data in patients with FSHD and non-FSHD controls for 6 weeks. We demonstrated the initial ability to detect differences in features in patients with FSHD and non-FSHD controls using smartphones and wearables, mainly based on data related to physical and social activity. TRIAL REGISTRATION: ClinicalTrials.gov NCT04999735; https://www.clinicaltrials.gov/ct2/show/NCT04999735.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...