Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38366617

RESUMO

We report on a 6-year-old girl (18 kg/120 cm) who was diagnosed on day 6 postoperative with an occlusive thrombosis of a right ventricle-to-pulmonary artery conduit in the setting of a Ross procedure that was performed for severe native aortic valve insufficiency secondary to late diagnosis of bacterial endocarditis. We applied the Indigo® aspiration system from Penumbra® (Alameda, USA) to mechanically dissolve and remove the thrombus, restore flow, gradually wean from extracorporeal support, and replace the conduit after 4 days. The patient experiences good surgical outcomes at 3 months of follow-up.


Assuntos
Insuficiência da Valva Aórtica , Artéria Pulmonar , Criança , Feminino , Humanos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Resultado do Tratamento , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Catéteres
3.
Acta Paediatr ; 113(5): 955-961, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38180109

RESUMO

AIM: Transcatheter closure of the patent ductus arteriosus (TCPDA) is increasingly used in preterm infants as an alternative to surgical ligation. However, clinically ill preterm infants are at risk of contrast nephropathy due to the angiography contrast agents used during the procedure. METHODS: We performed a single-centre before-and-after comparative study in VLBW infants to compare the kinetics of serum creatinine during the first 4 days after TCPDA with or without angiography. RESULTS: 69 patients were included and divided into two groups: TCPDA with (contrast+; n = 37) and without (contrast-, n = 32) use of contrast agent. The median dose [range] of contrast agent was 1.0 mL/kg [0.6-2.4 mL/kg]. The change in serum creatinine level between day 2 to 4 after TCPCA and baseline decreased in the contrast- group (-17% [-46%; 18%]), while it increased in the contrast+ group (7% [-24%; 202%] p = 0.002). Comparison of blood urea levels between groups showed similar significant differences. The change in serum creatinine between day 2 to 4 and baseline was significantly correlated with the dose of contrast agent (r2 = 0.682; p < 0.001). CONCLUSION: The use of contrast agents during TCPDA can potentially harm the renal function of very preterm infants. Therefore, we advise minimising or avoiding the use of contrast agents.


Assuntos
Permeabilidade do Canal Arterial , Canal Arterial , Doenças do Prematuro , Lactente , Recém-Nascido , Humanos , Recém-Nascido Prematuro , Meios de Contraste/efeitos adversos , Creatinina , Permeabilidade do Canal Arterial/diagnóstico por imagem , Rim/diagnóstico por imagem , Resultado do Tratamento
4.
Cardiol Young ; 34(1): 209-211, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38031499

RESUMO

We report a 20-year-old female patient (76 Kg/164 cm) with an extra-cardiac Fontan circulation who was referred to our institution for exertional dyspnoea and desaturation. The patient was diagnosed with a large calcified thrombus at the level of the Fontan fenestration, protruding inside the lumen of the conduit and reducing the diameter by half with a 3 mmHg pressure gradient. Transcatheter stent expansion of the obstructed extra-cardiac conduit was done with a 48 mm long XXL PTFE-covered Optimus-CVS® under temporary cerebral embolic protection with a TriGUARD-3™ deflection filter device (Keystone Heart). There was no procedural complication and the 3 months clinical outcomes are good.


Assuntos
Dispositivos de Proteção Embólica , Técnica de Fontan , Feminino , Humanos , Adulto Jovem , Adulto , Cateterismo Cardíaco , Stents/efeitos adversos , Técnica de Fontan/efeitos adversos , Resultado do Tratamento
5.
Eur Heart J ; 45(3): 198-210, 2024 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-37874971

RESUMO

BACKGROUND AND AIMS: Transcatheter pulmonary valve implantation (TPVI) is indicated to treat right-ventricular outflow tract (RVOT) dysfunction related to congenital heart disease (CHD). Outcomes of TPVI with the SAPIEN 3 valve that are insufficiently documented were investigated in the EUROPULMS3 registry of SAPIEN 3-TPVI. METHODS: Patient-related, procedural, and follow-up outcome data were retrospectively assessed in this observational cohort from 35 centres in 15 countries. RESULTS: Data for 840 consecutive patients treated in 2014-2021 at a median age of 29.2 (19.0-41.6) years were obtained. The most common diagnosis was conotruncal defect (70.5%), with a native or patched RVOT in 50.7% of all patients. Valve sizes were 20, 23, 26, and 29 mm in 0.4%, 25.5%, 32.1%, and 42.0% of patients, respectively. Valve implantation was successful in 98.5% [95% confidence interval (CI), 97.4%-99.2%] of patients. Median follow-up was 20.3 (7.1-38.4) months. Eight patients experienced infective endocarditis; 11 required pulmonary valve replacement, with a lower incidence for larger valves (P = .009), and four experienced pulmonary valve thrombosis, including one who died and three who recovered with anticoagulation. Cumulative incidences (95%CI) 1, 3, and 6 years after TPVI were as follows: infective endocarditis, 0.5% (0.0%-1.0%), 0.9% (0.2%-1.6%), and 3.8% (0.0%-8.4%); pulmonary valve replacement, 0.4% (0.0%-0.8%), 1.3% (0.2%-2.4%), and 8.0% (1.2%-14.8%); and pulmonary valve thrombosis, 0.4% (0.0%-0.9%), 0.7% (0.0%-1.3%), and 0.7% (0.0%-1.3%), respectively. CONCLUSIONS: Outcomes of SAPIEN 3 TPVI were favourable in patients with CHD, half of whom had native or patched RVOTs.


Assuntos
Endocardite Bacteriana , Endocardite , Cardiopatias Congênitas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Trombose , Adulto , Humanos , Cateterismo Cardíaco/efeitos adversos , Endocardite/epidemiologia , Endocardite Bacteriana/complicações , Cardiopatias Congênitas/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Desenho de Prótese , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/epidemiologia , Insuficiência da Valva Pulmonar/cirurgia , Sistema de Registros , Estudos Retrospectivos , Trombose/etiologia , Resultado do Tratamento
6.
Artigo em Inglês | MEDLINE | ID: mdl-38006998

RESUMO

OBJECTIVE: Coronary obstruction is a rare but common complication of the arterial switch operation for transposition of the great arteries. The majority of patients remain asymptomatic and no risk factors allow targeting for reinforced surveillance. We aim to review the natural history of patients diagnosed with coronary obstruction after arterial switch operation for transposition of the great arteries and occurrence of coronary-related outcomes. METHODS: We retrospectively reviewed medical records of the 102 patients diagnosed with coronary obstruction after arterial switch operation for transposition of the great arteries in our institution from 1981 to 2022. Outcomes were anti-ischemic treatment introduction, revascularization (surgical or percutaneous angioplasty), and death; investigations that motivated revascularization were also reviewed. RESULTS: Twenty-eight out of 102 patients presented with myocardial ischemia during the immediate postoperative phase, 31 were diagnosed when symptomatic, and 43 were identified at the presymptomatic stage, according to our screening policy in preschool-aged children. Stenosis-related event occurrence was, respectively, 29 out of 31 and 32 out of 43 in the latter 2 subgroups. Coronary-related mortality reached 10% in patients diagnosed when symptomatic; no patients died in the presymptomatic subgroup. Of the 28 low-risk patients with no signs of ischemia at diagnosis, 10 developed obstruction warranting reintervention during follow-up. Revascularization was motivated by appearance of symptoms in patients with severe stenosis in normal coronary dispositions, and by clinical symptoms or documented silent ischemia in abnormal coronary patterns. CONCLUSIONS: Occurrence of stenosis-related events remains significant in patients after arterial switch operation, underlining the importance of early diagnosis for timely intervention. Initial anatomical evaluation identifies stenotic and at-risk patients; this will require periodical function testing. Follow-up modalities can be tailored to a patient's individual anatomic characteristics.

7.
JACC Cardiovasc Interv ; 16(21): 2587-2599, 2023 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-37855807

RESUMO

Superior sinus venosus defect is a communication between the right and left atrium located above the upper margin of the oval fossa, immediately inferior to the junction of the superior vena cava and the right atrium. It is systematically associated with partial anomalous pulmonary venous drainage, especially of the right upper pulmonary vein. Surgical repair has been the gold standard approach to close that defect. Introduced in 2014, percutaneous closure has gradually become a safe and effective alternative to surgery in carefully selected patients, although worldwide experience remains limited. This article provides an appraisal of the patients' selection process and a step-by-step description of the procedure as well as a comprehensive review of its outcomes.


Assuntos
Comunicação Interatrial , Veias Pulmonares , Humanos , Veia Cava Superior/diagnóstico por imagem , Resultado do Tratamento , Comunicação Interatrial/terapia , Comunicação Interatrial/cirurgia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Veias Pulmonares/anormalidades
8.
Children (Basel) ; 10(7)2023 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-37508694

RESUMO

BACKGROUND: A pulmonary sequestration (PS) is an area of bronchopulmonary tissue with aberrant arterial supply. Transcatheter occlusion of PSs is an appealing treatment option, but data on outcomes remain scarce. We aim to describe our experience with transcatheter management of PS in infants and children. METHODS: Retrospective review of clinical data of all patients with suspected PS sent for diagnostic and/or interventional cardiac catheterization at our institution between January 1999 and May 2021. Procedural considerations, techniques, standard safety, and outcomes were assessed. RESULTS: We identified 71 patients (52.1% males), with median age and weight of 4.9 months (IQR, 2.1-26.6) and 4.2 kg (IQR, 3.9-12.1), respectively. Sixty-one (86%) patients had associated congenital heart defects (CHDs). Forty-two (59%) patients had pulmonary arterial hypertension (PAH) at the time of diagnosis. Fifty-three (74.7%) patients underwent embolization of the PS feeding vessel using microcoils and/or vascular plugs, and eight (15.1%) of these were neonates who presented with severe PAH and cardiac failure. Two patients had large feeding vessels and were treated surgically. Sixteen (22.5%) patients with small feeding vessels received conservative management. At median follow-up of 36.4 months (IQR, 2.1-89.9), seven patients had died, 24 patients had CHD corrective surgeries, 26 patients had redo catheterizations, and five patients had persistent PAH. No PS surgical resection was needed, and no infection of the remaining lung tissue occurred. CONCLUSIONS: Transcatheter assessment and treatment of PSs is a safe and effective procedure. Neonates with large PSs are severely symptomatic and improve remarkably after PS closure. PS embolization and surgical repair of associated CHDs generally leads to the normalization of pulmonary pressures.

9.
Eur J Cardiothorac Surg ; 64(1)2023 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-37348856

RESUMO

OBJECTIVES: Disconnected pulmonary artery (PA) is a rare anomaly that can be isolated or associated with complex intracardiac malformations. Early reimplantation of the disconnected PA is recommended to allow growth and satisfactory pulmonary perfusion while preventing collateral artery development. The aim of this study was to describe the characteristics of patients with disconnected PA and, for those who had surgical reimplantation, to determine the incidence, delay and predictive factors of reintervention for reconnected PA stenosis. METHODS: We include patients with the diagnosis of congenitally disconnected PA and surgical repair at our institution. RESULTS: Retrospective observational study of 55 patients with a disconnected PA. Fifty-one underwent surgical correction and were followed up at our institution between 2000 and 2022. Disconnected PAs were observed in isolation in 31% of the cases. The most frequent form was left PA originating from the arterial duct (58%). The reimplantation was done at the median age of 12 days. Anastomotic stenosis was observed during follow-up in 71% of the patients with 75% of them requiring reintervention (55% of the population). The median delay to reintervention was 3.2 years after reimplantation, and >25% of reinterventions on the reimplanted PA occurred within the first postoperative year. We found more reintervention if associated cardiac defect, without significant statistic difference. Weight at re-confluence, presence of ductal tissue at the origin of the PA and prior shunt placement on the disconnected PA were not found to be risk factors for reintervention. DISCUSSION: After surgical reimplantation of PA, >50% of patients required reintervention for PA stenosis. Technical improvements should be sought to reduce the incidence of this complication.


Assuntos
Artéria Pulmonar , Humanos , Lactente , Recém-Nascido , Artéria Pulmonar/cirurgia , Seguimentos , Constrição Patológica , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
10.
Eur J Epidemiol ; 38(7): 821-834, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37191831

RESUMO

Pediatric patients with congenital heart disease (CHD) often undergo low dose ionizing radiation (LDIR) from cardiac catheterization (CC) for the diagnosis and/or treatment of their disease. Although radiation doses from a single CC are usually low, less is known about the long-term radiation associated cancer risks. We aimed to assess the risk of lympho-hematopoietic malignancies in pediatric CHD patients diagnosed or treated with CC. A French cohort of 17,104 children free of cancer who had undergone a first CC from 01/01/2000 to 31/12/2013, before the age of 16 was set up. The follow-up started at the date of the first recorded CC until the exit date, i.e., the date of death, the date of first cancer diagnosis, the date of the 18th birthday, or the 31/12/2015, whichever occurred first. Poisson regression was used to estimate the LDIR associated cancer risk. The median follow-up was 5.9 years, with 110,335 person-years. There were 22,227 CC procedures, yielding an individual active bone marrow (ABM) mean cumulative dose of 3.0 milligray (mGy). Thirty-eight incident lympho-hematopoietic malignancies were observed. When adjusting for attained age, gender and predisposing factors to cancer status, no increased risk was observed for lympho-hematopoietic malignancies RR/mGy = 1.00 (95% CI: 0.88; 1.10). In summary, the risk of lympho-hematopoietic malignancies and lymphoma was not associated to LDIR in pediatric patients with CHD who undergo CC. Further epidemiological studies with greater statistical power are needed to improve the assessment of the dose-risk relationship.


Assuntos
Cardiopatias Congênitas , Neoplasias Hematológicas , Neoplasias Induzidas por Radiação , Humanos , Criança , Fatores de Risco , Neoplasias Induzidas por Radiação/epidemiologia , Neoplasias Induzidas por Radiação/etiologia , Radiação Ionizante , Neoplasias Hematológicas/epidemiologia , Neoplasias Hematológicas/complicações , Cateterismo Cardíaco/efeitos adversos , Doses de Radiação
11.
Circ Arrhythm Electrophysiol ; 16(6): e011745, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37170812

RESUMO

BACKGROUND: Ventricular arrhythmias and sudden death are recognized complications in tetralogy of Fallot. Electrophysiological studies (EPS) before pulmonary valve replacement (PVR), the most common reintervention in tetralogy of Fallot, could potentially inform therapy to improve arrhythmic outcomes. METHODS: A prospective multicenter study was conducted to systematically assess EPS with programmed ventricular stimulation in patients with tetralogy of Fallot referred for PVR from January 2020 to December 2021. A standardized stimulation protocol was used across all centers. RESULTS: A total of 120 patients were enrolled, mean age 39.2±14.5 years, 53.3% males. Sustained ventricular tachycardia was induced in 27 (22.5%) patients. When identifiable, the critical isthmus most commonly implicated (ie, in 90.0%) was between the ventricular septal defect patch and pulmonary annulus. Factors independently associated with inducible ventricular tachycardia were history of atrial arrhythmia (odds ratio, 8.56 [95% CI, 2.43-34.73]) and pulmonary annulus diameter >26 mm (odds ratio, 5.05 [95% CI, 1.47-21.69]). The EPS led to a substantial change in management in 23 (19.2%) cases: 18 (15.0%) had catheter ablation, 3 (2.5%) surgical cryoablation during PVR, and 9 (7.5%) defibrillator implantation. Repeat EPS 5.1 (4.8-6.2) months after PVR was negative in 8 of 9 (88.9%) patients. No patient experienced a sustained ventricular arrhythmia during 13 (6.1-20.1) months of follow-up. CONCLUSIONS: Systematically performing programmed ventricular stimulation in patients with tetralogy of Fallot referred for PVR yields a high rate of inducible ventricular tachycardia and carries the potential to alter management. It remains to be determined whether a standardized treatment approach based on the results of EPS will translate into improved outcomes. REGISTRATION: URL: https://clinicaltrials.gov/ct2/show/NCT04205461; Unique identifier: NCT04205461.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar , Valva Pulmonar , Taquicardia Ventricular , Tetralogia de Fallot , Masculino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Feminino , Valva Pulmonar/cirurgia , Tetralogia de Fallot/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia
12.
Cardiol Young ; 33(12): 2597-2603, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37073828

RESUMO

BACKGROUND: Low-profile stent implantation remains a rescue treatment for aortic coarctation and branch pulmonary arteries stenosis in small children. Stent re-expansion to cope with vascular growth remains problematic. OBJECTIVES: To evaluate ex vivo feasibility and mechanical behaviour of over-dilating BeSmooth peripheral stents (Bentley InnoMed, Germany). METHODS: Three BeSmooth peripheral stents in diameters of 7, 8, and 10 mm were dilated to nominal pressure and then 13 atm. BeSmooth Ø7 × 23 mm was sequentially post-dilated using 12, 14, and 16 mm high-pressure balloons. BeSmooth Ø10 × 57 mm was post-dilated with a 14 mm balloon and then with a 48 mm bare-metal Optimus XXL stent hand-mounted on a 14 mm balloon (stent-in-stent). BeSmooth Ø8 × 57 mm was directly post-dilated with a 48 mm bare-metal Optimus XXL stent hand-mounted on a 16 mm balloon (stent-in-stent). The stents' diameter and length were measured. Digital inflation pressure was noted. Balloon rupture and stent fracture patterns were closely evaluated. RESULTS: At 20atm pressure, BeSmooth Ø7 × 23 mm shortened to 2 mm forming a 12 mm diameter solid ring circle and the woven balloon ruptured radially. At 10 atm pressure, BeSmooth Ø10 × 57 mm fractured longitudinally in various dispatched breaking points at a diameter of 13 mm without shortening and ruptured the balloon with multiple pinholes. At 10 atm pressure, BeSmooth Ø8 × 57 mm fractured centrally at three different points at a diameter of 11.5 mm without shortening and the balloon broke radially in half. CONCLUSIONS: In our benchmark tests, extreme shortening, severe balloon rupture, or unpredictable stent fracture patterns at small balloon diameters limits safe post-dilation of BeSmooth stents beyond 13 mm. BeSmooth stents are not ideal candidates for off-label stent interventions in smaller patients.


Assuntos
Angioplastia com Balão , Criança , Adulto , Humanos , Dilatação , Desenho de Prótese , Stents , Estresse Mecânico , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 101(5): 863-869, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36861752

RESUMO

We report the case of a 5.5-year-old patient (16 kg/105 cm) who presented with plastic bronchitis (PB) refractory to conservative treatment 3 months after completion of Fontan palliation. Bi-inguinal transnodal fluoroscopy-guided lymphangiogram confirmed the chylous leak originating from the thoracic duct (TD) into the chest and did not opacify any central lymphatic vessel for direct transabdominal puncture. Retrograde transfemoral approach was adopted to catheterize the TD and selectively embolize its caudal portion using microcoils and liquid embolic adhesive. Recurrence of symptoms after 2 months indicated a redo catheterization to occlude the TD entirely using the same technique. The procedure was successful and the patient was discharged after 2 days with sustained clinical improvement at 24 months postoperative. In the context of refractory PB, end-to-end transvenous retrograde embolization of the TD appears to be an interesting alternative to more complex interventions such as transabdominal puncture, decompression, or surgical ligation of the TD.


Assuntos
Bronquite , Embolização Terapêutica , Técnica de Fontan , Humanos , Pré-Escolar , Ducto Torácico/diagnóstico por imagem , Técnica de Fontan/efeitos adversos , Resultado do Tratamento , Bronquite/diagnóstico por imagem , Bronquite/etiologia , Bronquite/terapia , Embolização Terapêutica/métodos
14.
Eur Radiol ; 33(8): 5455-5464, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36905468

RESUMO

OBJECTIVES: Pulmonary regurgitation (PR) is common in adult congenital heart disease (ACHD). 2D phase contrast MRI is the reference method for the quantification of PR and helps in the decision of pulmonary valve replacement (PVR). 4D flow MRI can be an alternative method to estimate PR but more validation is still needed. Our purpose was to compare 2D and 4D flow in PR quantification using the degree of right ventricular remodeling after PVR as the reference standard. METHODS: In 30 adult patients with a pulmonary valve disease recruited between 2015 and 2018, PR was assessed using both 2D and 4D flow. Based on the clinical standard of care, 22 underwent PVR. The pre PVR estimate of PR was compared using the post-operative decrease in right ventricle end-diastolic volume on follow-up exam as reference. RESULTS: In the overall cohort, regurgitant volume (Rvol) and regurgitant fraction (RF) of PR measured by 2D and 4D flow were well correlated but with moderate agreement in the overall cohort (r = 0.90, mean diff. -14 ± 12.5 mL; and r = 0.72, mean diff. -15 ± 13%; all p < 0.0001). Correlations between Rvol estimates and right ventricle end-diastolic volume decrease after PVR was higher with 4D flow (r = 0.80, p < 0.0001) than with 2D flow (r = 0.72, p < 0.0001). CONCLUSIONS: In ACHD, PR quantification from 4D flow better predicts post-PVR right ventricle remodeling than that from 2D flow. Further studies are needed to evaluate the added value of this 4D flow quantification for guiding replacement decision. KEY POINTS: • Using 4D flow MRI allows a better quantification of pulmonary regurgitation in adult congenital heart disease than 2D flow when taking right ventricle remodeling after pulmonary valve replacement as a reference. • A plane positioned perpendicular to the ejected flow volume as allowed by 4D flow provides better results to estimate pulmonary regurgitation.


Assuntos
Cardiopatias Congênitas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Humanos , Adulto , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Seguimentos , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico por imagem , Remodelação Ventricular , Imageamento por Ressonância Magnética , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Função Ventricular Direita
15.
J Am Heart Assoc ; 12(7): e029085, 2023 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-36974756

RESUMO

Background Right heart catheterization (RHC) is a high-risk procedure in children with pulmonary arterial hypertension without clear guidelines for the indications and targets of invasive reassessment. Our objectives are to define the aims of repeated RHC and evaluate the correlation between noninvasive criteria and hemodynamic parameters. Methods and Results Clinical and hemodynamic characteristics from 71 incident treatment-naïve children (median age 6.2 years) with pulmonary arterial hypertension who had a baseline and reevaluation RHC were analyzed. Correlations between noninvasive predictors and hemodynamic parameters were tested. Adverse outcomes were defined as death, lung transplantation, or Potts shunt. At baseline, pulmonary vascular resistance index (hazard ratio [HR] 1.07 per 1 WU·m2 increase [95% CI, 1.02-1.12], P=0.002), stroke volume index (HR 0.95 per 1 L·min-1·m-2 increase [95% CI, 0.91-0.99], P=0.012), pulmonary artery compliance index (HR 0.16 per 1 mL·mm Hg-1·m-2 increase [95% CI, 0.051-0.52], P=0.002), and right atrial pressure (HR, 1.31 per 1 mm Hg increase [95% CI, 1.01-1.71], P=0.043) were associated with adverse outcomes. Pulmonary vascular resistance index, pulmonary artery compliance index, and right atrial pressure were still associated with a worse outcome at second RHC. Noninvasive criteria accurately predicted hemodynamic evolution; however, 70% of the patients who had improved based on noninvasive criteria still presented at least 1 "at risk" hemodynamics at second RHC. Conclusions Pulmonary vascular resistance index, pulmonary artery compliance index, and right atrial pressure are solid predictors of adverse outcomes in pediatric pulmonary arterial hypertension and potential therapeutic targets. Noninvasive criteria accurately predict the evolution of hemodynamic parameters, but insufficiently. Repeated RHC are helpful to identify children with persistent higher risk after treatment introduction.


Assuntos
Hipertensão Arterial Pulmonar , Humanos , Criança , Hipertensão Arterial Pulmonar/diagnóstico , Hemodinâmica , Hipertensão Pulmonar Primária Familiar , Cateterismo Cardíaco/métodos , Artéria Pulmonar
16.
Rev Esp Cardiol (Engl Ed) ; 76(10): 793-802, 2023 Oct.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36921915

RESUMO

INTRODUCTION AND OBJECTIVES: Magnetic resonance imaging (MRI) including 4D flow is used before percutaneous pulmonary valve implantation (PPVI). As PPVI is limited by the size of the right ventricular outflow tract (RVOT), accurate sizing is needed to plan the intervention. The aim of this study was to compare different MRI modalities and invasive angiography to balloon sizing of RVOT. METHODS: Single-center prospective study of patients who underwent PPVI for isolated pulmonary regurgitation assessed by 4D flow MRI, 3D steady-state free precession/gradient echo (3D SSFP/GRE) and contrast magnetic resonance angiography. Balloon sizing was considered as the reference. RESULTS: A total of 23 adults were included (mean age, 38.4±12.5 years). Eighteen patients underwent successful primary PPVI. The average of the narrowest RVOT diameter was 25.4±4.3 mm by balloon sizing. Compared to balloon sizing, RVOT diameters were better correlated when estimated by systolic 4D flow MRI (r=0.89, P<.001) than by diastolic 4D flow MRI (r=0.71, P <.001), 3D contrast magnetic resonance angiography (r=0.73; P <.001) and 3D SSFP/GRE (r=0.50; P=.04) and was not significantly correlated when estimated by 2D in diastole and systole. The mean difference between systolic 4D flow MRI and balloon sizing was 0.2 mm (95%CI, -3.5 to 3.9 mm), whereas it was wider with other techniques. CONCLUSIONS: Beyond the quantification of pulmonary valve regurgitation, 4D flow allows accurate estimation of RVOT diameters, especially in systole, which is fundamental before planning PPVI.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Adulto , Humanos , Pessoa de Meia-Idade , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/cirurgia , Angiografia por Ressonância Magnética/métodos , Resultado do Tratamento
17.
Cardiol Young ; 33(9): 1726-1729, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36918290

RESUMO

In neonatal Ebstein's anomaly of the tricuspid valve, prolonged ductal patency in patients without anatomic pulmonary valve atresia can be deleterious. Circular shunts may develop in patients with different degrees of pulmonary and tricuspid insufficiency. Closure of the arterial duct may result in haemodynamic improvement in particular scenarios. The transcatheter approach is a valuable closure alternative despite some technical difficulties in large-sized arterial ducts and low birth weight neonates. Herein, we report on two consecutive term newborns with Ebstein's anomaly and large arterial ducts in whom mechanical stimulus of the arterial duct during failed attempts of transcatheter closure led after two days to definitive closure followed by good clinical outcomes.


Assuntos
Canal Arterial , Anomalia de Ebstein , Atresia Pulmonar , Insuficiência da Valva Tricúspide , Humanos , Recém-Nascido , Anomalia de Ebstein/cirurgia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia
18.
Open Heart ; 10(1)2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36631173

RESUMO

OBJECTIVES: To evaluate bare-metal Optimus and polytetrafluoroethylene (PTFE)-covered Optimus-CVS balloon-expandable, cobalt-chromium, hybrid cell-designed stents in congenital heart disease (CHD) interventions. METHODS: Retrospective multicentre review of patients with CHD receiving Optimus stents. Stent mechanical behaviour, clinical indications and outcomes were assessed. RESULTS: 183 stents (49.2% XXL/15-ZIG, 33.3% XL/12-ZIG, 17.5% L/9-ZIG) were implanted (98.9% success rate, 2.3% serious procedural complication rate) in 170 patients (57.6% men, 64.1% adults), median age 23.6 years (IQR, 15.2-39.2) and weight 63.5 kg (IQR, 47-75.7). Indications were right ventricular outflow tract stand-alone stenting or before revalvulation (62.4%), aortic coarctation treatment (15.3%), Fontan-circuit fenestration closure (12.4%) and miscellaneous (10%). 86/170 (50.6%) patients had PTFE-covered stenting (50% prophylactic). In 86/170 (50.6%) patients with stenotic lesions, median percentage of achieved stent expansion was 93.4% (IQR, 85.5%-97.7%), median gradient decreased from 28 mm Hg (IQR, 19-41) to 5 mm Hg (IQR, 1-9) (p<0.001), median vessel diameters increased from 13 mm (IQR, 7.9-17) to 18.9 mm (IQR, 15.2-22) (p<0.001) and percentage of vessel expansion was 45.2% (IQR, 19.8%-91.3%). In 30/36 (83.3%) patients with graft, median dilation of 2 mm (IQR, 2-5) above nominal diameter was achieved. Median stent shortening was 10.9% (IQR, 6.1-15.1) and was associated only with expansion diameter (OR: 0.66, 95% CI: 0.38 to 0.93). No clinically relevant fracture, stent embolisation or dysfunction occurred on a median follow-up of 9 (IQR, 4-14) months. CONCLUSIONS: Optimus stents are effective tools for transcatheter treatment of simple and complex CHD. Optimus stents' reliable mechanical behaviour and particular covering design can promote widespread use.


Assuntos
Coartação Aórtica , Cardiopatias Congênitas , Adulto , Masculino , Humanos , Adulto Jovem , Feminino , Cromo , Cobalto , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/cirurgia , Stents , Politetrafluoretileno
19.
Front Cardiovasc Med ; 9: 1028304, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36386337

RESUMO

Background: Transcatheter Potts shunt (TPS) is a palliation alternative for children with severe pulmonary arterial hypertension (PAH). Debates on the long-term outcomes remain unsolved. Objectives: To evaluate long-term clinical and procedural outcomes of TPS intervention. Methods: Single-center retrospective data review of children with severe PAH who had TPS between 2009 and 2018. Patients who died per-operatively and early post-procedure were excluded. Long-term outcomes of survivors were evaluated. Results: Out of 13 identified patients (53.8% males), 7 had endovascular stenting of probe/patent arterial ducts, while 6 individuals had aorta-to-pulmonary radiofrequency perforation and covered stent placement. Compared to baseline, the overall clinical condition significantly improved at discharge (p < 0.001) and stayed better at the last visit (p < 0.05) despite frequent clinical worsening events across follow-up. Improvement in functional class across follow-up was significant (p < 0.001). There was, however, no significant improvement in other disease markers (TPASE, 6MWD z-scores, and NT-proBNP levels) or reduction in PAH medications. The median follow-up was 77.4 months (IQR, 70.7-113.4). Survival was 100% at 1 year and 92.3% at 6 years. Freedom from reinterventions was 77% at 1 year and 21% at 6 years. Nine (69.2%) patients had stent reinterventions at a median of 25 months (IQR, 9.5-56) postoperative. Balloon dilatation and restenting were performed in 53.8% and 46.2% of patients, respectively. High-pressure post-dilatation of implanted stents was performed in 53.8% of patients during TPS intervention for incomplete stent expansion and/or residual pressure gradient and was associated with higher rates of reinterventions (p = 0.021). Stent malfunctioning was present in 46.2% of patients at last follow-up. Two patients are listed for heart-lung transplantation. Conclusion: Survivors of TPS procedures experience significant improvement in functional class that can be durable. Clinical worsening and stent malfunctioning are frequent morbid events indicating recurrent transcatheter reinterventions throughout follow-up. Six-year survival is, however, satisfactory.

20.
Front Pediatr ; 10: 965989, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36110107

RESUMO

The Fontan operation represents the last of multiple steps that are offered a wide range of congenital cardiac lesions with a single ventricle (SV) physiology. Nowadays this surgical program consists of a total cavopulmonary connection (TCPC), by anastomosing systemic veins to the pulmonary arteries (PAs), excluding the right-sided circulation from the heart. As a result of imaging, surgical, percutaneous, and critical care improvements, survival in this population has steadily increased. However, the Fontan physiology chronically increases systemic venous pressure causing systemic venous congestion and decreased cardiac output, exposing patients to the failure of the Fontan circulation (FC), which is associated with a wide variety of clinical complications such as liver disease, cyanosis, thromboembolism, protein-losing enteropathy (PLE), plastic bronchitis (PB), and renal dysfunction, ultimately resulting in an increased risk of exercise intolerance, arrhythmias, and premature death. The pathophysiology of the failing Fontan is complex and multifactorial; i.e., caused by the single ventricle dysfunction (diastolic/systolic failure, arrhythmias, AV valve regurgitation, etc.) or caused by the specific circulation (conduits, pulmonary vessels, etc.). The treatment is still challenging and may include multiple options and tools. Among the possible options, today, interventional catheterization is a reliable option, through which different procedures can target various failing elements of the FC. In this review, we aim to provide an overview of indications, techniques, and results of transcatheter options to treat cavopulmonary stenosis, collaterals, impaired lymphatic drainage, and the management of the fenestration, as well as to explore the recent advancements and clinical applications of transcatheter cavopulmonary connections, percutaneous valvular treatments, and to discuss the future perspectives of percutaneous therapies in the Fontan population.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...