Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 7914, 2024 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575664

RESUMO

Medication-related osteonecrosis of the jaw (MRONJ) is a serious adverse reaction associated with antiresorptive drugs such as bisphosphonates and denosumab. When dealing with advanced and/or multiple MRONJ lesions undergoing surgical therapy, the extent of surgery is often a topic of discussion. The aim of this study was to identify the differences in bone density in and around the MRONJ lesion before and after surgical treatment to evaluate the needed surgical extend of the modelling osteotomy. In this retrospective study 26 patients with MRONJ lesions that were surgically treated in our department were observed. Length, width and bone density were measured in panoramic radiograph pre and postoperatively with the Imaging processing software Sidexis and ImageJ (Fiji). The necrotic area, the surrounding sclerotic area as well as the healthy contralateral side were observed. Measurements were performed by two independent observers. Pearson correlation was calculated to determine the interobserver variability. Bone density was significantly reduced in the necrotic bone area compared to the healthy unaffected contralateral reference side. The sclerotic bone area surrounding the necrosis showed increased bone density compared to the contralateral unaffected reference side. The density of the sclerotic bone area was increased in the previously affected MRONJ area in the postoperative panoramic radiograph. The pre and postoperative density showed no significant correlation to healing behaviour. The focus of the modelling osteotomy in surgical treatment of mature MRONJ lesions should be predominantly on the parts that appear necrotic and less dense in the panoramic radiograph as sclerotic areas might be an expression of bone reaction.


Assuntos
Osteonecrose da Arcada Osseodentária Associada a Difosfonatos , Conservadores da Densidade Óssea , Osteonecrose , Humanos , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/diagnóstico por imagem , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/cirurgia , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/tratamento farmacológico , Denosumab/efeitos adversos , Estudos Retrospectivos , Osteonecrose/induzido quimicamente , Osteonecrose/diagnóstico por imagem , Osteonecrose/cirurgia , Conservadores da Densidade Óssea/efeitos adversos , Difosfonatos/efeitos adversos , Necrose/induzido quimicamente
2.
Eur Radiol ; 2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37855855

RESUMO

OBJECTIVES: T2 STIR MRI sequences can detect preclinical changes associated with periodontal inflammation, i.e. intraosseous edema in the tooth-supporting bone. In this study, we assessed whether MRI can be used for monitoring periodontal disease. MATERIAL AND METHODS: In a prospective cohort study, we examined 35 patients with periodontitis between 10/2018 and 04/2019 by using 3D isotropic T2-weighted short tau inversion recovery (STIR) and Fast Field Echo T1-weighted Black bone sequences. All patients received standardized clinical exams before and three months after non-surgical periodontal therapy. Bone marrow edema extent was quantified in the STIR sequence at 922 sites before and after treatment. Results were compared with standard clinical findings. Non-parametric statistical analysis was performed. RESULTS: Non-surgical periodontal treatment caused significant improvement in mean probing depth (p < 0.001) and frequency of bleeding on probing (p < 0.001). The mean depth of osseous edema per site was reduced from a median [IQR] of 2 [1, 3] mm at baseline to 1 [0, 3] mm, (p < 0.001). Periodontal treatment reduced the frequency of sites with edema from 35 to 24% (p < 0.01). CONCLUSION: The decrease of periodontal bone marrow edema, as observed with T2 STIR MR imaging, is indicative of successful periodontal healing. CLINICAL RELEVANCE STATEMENT: T2 STIR hyperintense bone marrow edema in the periodontal bone decreases after treatment and can therefore be used to evaluate treatment success. Furthermore, MRI reveals new options to depict hidden aspects of periodontitis. KEY POINTS: • T2 STIR hyperintense periodontal intraosseous edema was prospectively investigated in 35 patients with periodontitis before and after treatment and compared to clinical outcomes. • The frequency of affected sites was reduced from 35 to 24% (p < 0.001), and mean edema depth was reduced from a median [IQR] of 2 [1, 3] mm at baseline to 1 [0, 3] mm 3 months after treatment. (p < 0.001). • T2 STIR sequences can be used to monitor the posttreatment course of periodontitis.

3.
J Clin Med ; 12(12)2023 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-37373793

RESUMO

A total of 7% of all benign bone lesions are diagnosed as fibrous dysplasia (FD). The symptoms of FD of the jaw range from asymptomatic to dental anomalies, pain and facial asymmetry. Due to its resemblance to other fibro-osseous bone lesions, misdiagnosis often occurs and can lead to inadequate treatment. Particularly in the jaw, this lesion does not become quiescent during puberty, making fundamental knowledge about the diagnosis and treatment of FD crucial. Mutational analysis and nonsurgical approaches offer new diagnostic and therapeutic options. In this review, we examine the advances and the difficulties of the diagnosis and the various treatment modalities of FD of the jaw in order to capture the current scientific knowledge on this bone disease.

4.
Clin Oral Investig ; 27(9): 5063-5072, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37382718

RESUMO

OBJECTIVE: To determine the accuracy of maxillary positioning using computer-designed and manufactured occlusal splints or patient-specific implants in orthognathic surgery. MATERIAL AND METHODS: A retrospective analysis of 28 patients that underwent virtually planned orthognathic surgery with maxillary Le Fort I osteotomy either using VSP-generated splints (n = 13) or patient-specific implants (PSI) (n = 15) was conducted. The accuracy and surgical outcome of both techniques were compared by superimposing preoperative surgical planning with postoperative CT scans and measurement of translational and rotational deviation for each patient. RESULTS: The 3D global geometric deviation between the planned position and the postoperative outcome was 0.60 mm (95%-CI 0.46-0.74, range 0.32-1.11 mm) for patients with PSI and 0.86 mm (95%-CI 0.44-1.28, range 0.09-2.60 mm) for patients with surgical splints. Postoperative differences for absolute and signed single linear deviations between planned and postoperative position were a little higher regarding the x-axis and pitch but lower regarding the y- and z-axis as well as yaw and roll for PSI compared to surgical splints. There were no significant differences regarding global geometric deviation, absolute and signed linear deviations in the x-, y-, and z-axis, and rotations (yaw, pitch, and roll) between both groups. CONCLUSIONS: Regarding accuracy for positioning of maxillary segments after Le Fort I osteotomy in orthognathic surgery patient-specific implants and surgical splints provide equivalent high accuracy. CLINICAL RELEVANCE: Patient-specific implants for maxillary positioning and fixation facilitate the concept of splintless orthognathic surgery and can be reliably used in clinical routines.


Assuntos
Implantes Dentários , Cirurgia Ortognática , Procedimentos Cirúrgicos Ortognáticos , Cirurgia Assistida por Computador , Humanos , Placas Oclusais , Procedimentos Cirúrgicos Ortognáticos/métodos , Estudos Retrospectivos , Cirurgia Assistida por Computador/métodos , Maxila/cirurgia , Computadores , Imageamento Tridimensional/métodos , Osteotomia de Le Fort/métodos
5.
BMC Oral Health ; 23(1): 274, 2023 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-37165409

RESUMO

BACKGROUND: One of the main uses of artificial intelligence in the field of orthodontics is automated cephalometric analysis. Aim of the present study was to evaluate whether developmental stages of a dentition, fixed orthodontic appliances or other dental appliances may affect detection of cephalometric landmarks. METHODS: For the purposes of this study a Convolutional Neural Network (CNN) for automated detection of cephalometric landmarks was developed. The model was trained on 430 cephalometric radiographs and its performance was then tested on 460 new radiographs. The accuracy of landmark detection in patients with permanent dentition was compared with that in patients with mixed dentition. Furthermore, the influence of fixed orthodontic appliances and orthodontic brackets and/or bands was investigated only in patients with permanent dentition. A t-test was performed to evaluate the mean radial errors (MREs) against the corresponding SDs for each landmark in the two categories, of which the significance was set at p < 0.05. RESULTS: The study showed significant differences in the recognition accuracy of the Ap-Inferior point and the Is-Superior point between patients with permanent dentition and mixed dentition, and no significant differences in the recognition process between patients without fixed orthodontic appliances and patients with orthodontic brackets and/or bands and other fixed orthodontic appliances. CONCLUSIONS: The results indicated that growth structures and developmental stages of a dentition had an impact on the performance of the customized CNN model by dental cephalometric landmarks. Fixed orthodontic appliances such as brackets, bands, and other fixed orthodontic appliances, had no significant effect on the performance of the CNN model.


Assuntos
Braquetes Ortodônticos , Ortodontia , Humanos , Inteligência Artificial , Redes Neurais de Computação , Aparelhos Ortodônticos , Cefalometria/métodos
6.
Laryngoscope Investig Otolaryngol ; 7(2): 369-379, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35434332

RESUMO

Objective: To evaluate the feasibility and accuracy of implementing three-dimensional virtual surgical planning (VSP) and subsequent transfer by additive manufactured tools in the secondary reconstruction of residual post-traumatic deformities in the midface. Methods: Patients after secondary reconstruction of post-traumatic midfacial deformities were included in this case series. The metrical deviation between the virtually planned and postoperative position of patient-specific implants (PSI) and bone segments was measured at corresponding reference points. Further information collected included demographic data, post-traumatic symptoms, and type of transfer tools. Results: Eight consecutive patients were enrolled in the study. In five patients, VSP with subsequent manufacturing of combined predrilling/osteotomy guides and PSI was performed. In three patients, osteotomy guides, repositioning guides, and individually prebent plates were used following VSP. The median distances between the virtually planned and the postoperative position of the PSI were 2.01 mm (n = 18) compared to a median distance concerning the bone segments of 3.05 mm (n = 12). In patients where PSI were used, the median displacement of the bone segments was lower (n = 7, median 2.77 mm) than in the group with prebent plates (n = 5, 3.28 mm). Conclusion: This study demonstrated the feasibility of VSP and transfer by additive manufactured tools for the secondary reconstruction of complex residual post-traumatic deformities in the midface. However, the median deviations observed in this case series were unexpectedly high. The use of navigational systems may further improve the level of accuracy.

7.
Comput Biol Med ; 137: 104791, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34464850

RESUMO

BACKGROUND: To assess the accuracy with which CAD/CAM-fabricated patient-specific titanium implants (PSI) are positioned for inferior and/or medial orbital wall reconstruction without the use of intraoperative navigation. METHODS: Patients who underwent a primary reconstruction of the orbital walls with PSI due to fractures were enrolled in this retrospective cohort analysis. The primary outcome variables were the mean surface distances (MSD) between virtually planned and postoperative PSI position and single linear deviations in the x-, y- and z-axis at corresponding reference points. Secondary outcome variables included demographic data, classification of orbital wall defects and clinical outcomes. RESULTS: A total of 33 PSI (orbital floor n = 22; medial wall, n = 11) were examined in 27 patients. MSD was on a comparable level for the orbital floor and medial wall (median 0.39 mm, range 0.22-1.53 mm vs. median 0.42 mm, range 0.21-0.98 mm; p = 0.56). Single linear deviations were lower for reconstructions of the orbital floor compared to the medial wall (median 0.45 vs. 0.79 mm; p < 0.05). There was no association between the occurrence of diplopia and the accuracy level (p = 0.418). CONCLUSIONS: Free-hand positioning of PSI reaches a clinically appropriate level of accuracy, limiting the necessity of navigational systems to selected cases.


Assuntos
Fraturas Orbitárias , Procedimentos de Cirurgia Plástica , Humanos , Órbita/cirurgia , Fraturas Orbitárias/diagnóstico por imagem , Fraturas Orbitárias/cirurgia , Próteses e Implantes , Estudos Retrospectivos
8.
Clin Implant Dent Relat Res ; 23(5): 779-788, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34318580

RESUMO

BACKGROUND: Providing accurate 3-dimensional virtual bone surface models is a prerequisite for virtual surgical planning and additive manufacturing in craniomaxillofacial surgery. For this purpose, magnetic resonance imaging (MRI) may be a radiation-free alternative to computed tomography (CT) and cone beam computed tomography (CBCT). PURPOSE: The aim of this study was to assess the geometric accuracy of 3-dimensional T1-weighted MRI-derived virtual bone surface models of the mandible in comparison to CT and CBCT. MATERIALS AND METHODS: Specimens of the mandible from porcine cadavers were scanned with (1) a 3-dimensional T1-weighted MRI sequence (0.6 mm isotropic voxel) optimized for bone imaging, (2) CT, and (3) CBCT. Cortical mandibular structures (n = 10) were segmented using semiautomated and manual techniques. Imaging-based virtual 3-dimensional models were aligned with a high-resolution optical 3-dimensional surface scan of the dissected bone (=ground truth) and global geometric deviations were calculated (mean surface distance [MSD]/root-mean-square distance [RMSD]). Agreement between the imaging modalities was assessed by equivalence testing and Bland-Altman analysis. RESULTS: Intra- and inter-rater agreement was on a high level for all modalities. Global geometric deviations (MSD/RMSD) between optical scans and imaging modalities were 0.225 ± 0.020 mm/0.345 ± 0.074 mm for CT, 0.280 ± 0.067 mm/0.371 ± 0.074 mm for MRI, and 0.352 ± 0.076 mm/0.454 ± 0.071 mm for CBCT. All imaging modalities were statistically equivalent within an equivalence margin of ±0.3 mm, and Bland-Altman analysis indicated high agreement as well. CONCLUSIONS: The results of this study indicate that the accuracy and reliability of MRI-derived virtual 3-dimensional bone surface models is equal to CT and CBCT. MRI may be considered as a reliable alternative to CT and CBCT in computer-assisted craniomaxillofacial surgery.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Mandíbula , Animais , Cadáver , Imageamento por Ressonância Magnética , Mandíbula/diagnóstico por imagem , Reprodutibilidade dos Testes , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...