Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Acta Neurochir (Wien) ; 155(2): 237-46, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23224577

RESUMO

BACKGROUND: Elective temporary clipping (ETC) is increasingly used in surgery for aneurysms. This study was to assess whether the impact of ETC on intraoperative aneurysmal rupture (IAR) translates into neurological outcome. METHODS: Patients who underwent surgery for ruptured anterior circulation aneurysms were prospectively studied for various factors related to ETC, IAR and neurological outcome at 3 months. Univariate and multivariate analyses were performed using SPSS20. RESULTS: Of the total 273 ruptured aneurysm surgeries studied, IAR was observed in only six out of 132 aneurysms (4.5 %) who had ETC, compared with 78 out of 141 (55.3 %) without ETC (p < 0.001). Aneurysms complicated by IAR had significantly longer clipping time (8.3 min) compared with those without IAR (1.9 min) (p < 0.001). IAR had significant association with unfavorable outcome (38 % vs. 24 %) (p = 0.02). Patients with ETC had significantly shorter clipping time (2.9 min) compared with those without ETC (4.8 min) (p = 0.02). Unfavorable outcome was noted in 30 out of 132 with ETC (23 %), compared with 48 out of 141 without ETC (34 %) (p = 0.04). This beneficial effect was nonsignificantly greater in younger and good clinical grade patients. While episodes of ETC within clipping time of 20 min did not show significant difference in outcome, repeated rescue clipping (45 % unfavorable outcome, p = 0.048) and total clipping time of at least 20 min (75 % unfavorable outcome, p = 0.008) had significant impact on outcome. In multivariate analysis, the use of ETC (p = 0.027) and total temporary clipping less than 20 min (p = 0.049) were noted to result in significantly better outcome, independent of other factors. CONCLUSIONS: The use of ETC decreased the occurrence of IAR and the total clipping time, thereby leading to significantly better outcome, independent of other factors. While repeated elective clipping within total clipping time of 20 min did not influence outcome, repeated rescue clipping and total clipping time of at least 20 min had significant impact on outcome.


Assuntos
Aneurisma Roto/epidemiologia , Aneurisma Roto/prevenção & controle , Procedimentos Cirúrgicos Eletivos , Aneurisma Intracraniano/cirurgia , Complicações Intraoperatórias , Adolescente , Adulto , Idoso , Aneurisma Roto/diagnóstico , Feminino , Seguimentos , Escala de Resultado de Glasgow , Humanos , Incidência , Aneurisma Intracraniano/complicações , Aneurisma Intracraniano/diagnóstico , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
2.
Ann Thorac Surg ; 82(1): 298-302, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16798233

RESUMO

BACKGROUND: Transhiatal esophagectomy (THE) is a common operative procedure for carcinoma esophagus. Complications of this procedure include arrhythmias and hypotension during blunt dissection of the esophagus from posterior mediastinum. In the literature, exact incidence and type of arrhythmias have not been reported. We employed Holter monitoring during mediastinal manipulation in patients undergoing THE, for this purpose. METHODS: This prospective study was carried out in 20 consecutive American Society of Anesthesiologists grade I-II patients undergoing THE. Anesthetic technique included induction with thiopentone and maintenance with morphine, vecuronium, and isoflurane. In addition to routine parameters, Holter monitoring was undertaken to record the exact incidence and types of arrhythmias. "Premanipulation" or control period included duration of 30 minutes preceding mediastinal manipulation, while "during manipulation" or study period included the duration of mediastinal manipulation. The incidence of arrhythmias was studied for 48 hours in the postoperative period. The Fisher exact test was applied to analyze incidence of arrhythmias and hypotension. RESULTS: Out of 20 patients, only 2 had arrhythmias in the premanipulation period, while 13 had arrhythmias during the manipulation period (p < 0.01). During the manipulation period, arrhythmias included supraventricular ectopics and ventricular ectopics in 2 patients each and a combination of both in 9 patients. Arrhythmias were transient and had no correlation with either duration or degree of hypotension in all the patients. However, there was a linear relationship between hypotension and duration of mediastinal manipulation. Two patients (10%) had atrial arrhythmias in the postoperative period. CONCLUSIONS: In transhiatal esophagectomy, there is a significant incidence of both arrhythmias and hypotension during mediastinal manipulation. The incidence of arrhythmias can be minimized by limiting the duration of the manipulation. The incidence of postoperative arrhythmias was not significant.


Assuntos
Arritmias Cardíacas/etiologia , Esofagectomia/efeitos adversos , Complicações Intraoperatórias/etiologia , Mediastino , Complicações Pós-Operatórias/etiologia , Adulto , Idoso , Arritmias Cardíacas/epidemiologia , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Complexos Atriais Prematuros/epidemiologia , Complexos Atriais Prematuros/etiologia , Perda Sanguínea Cirúrgica , Diafragma , Eletrocardiografia Ambulatorial , Neoplasias Esofágicas/cirurgia , Feminino , Humanos , Hipotensão/epidemiologia , Hipotensão/etiologia , Incidência , Complicações Intraoperatórias/epidemiologia , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Fatores de Tempo , Complexos Ventriculares Prematuros/epidemiologia , Complexos Ventriculares Prematuros/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...