Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
1.
Cancer Cell Int ; 24(1): 28, 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38212739

RESUMO

Primary cell lines are invaluable for exploring cancer biology and investigating novel treatments. Despite their numerous advantages, primary cultures are laborious to obtain and maintain in culture. Hence, established cell lines are still more common. This study aimed to evaluate a range of techniques for isolating primary breast cancer cultures, employing distinct enzymatic compositions, incubation durations, and mechanical approaches, including filtration. Out of several protocols, we opted for a highly effective method (Method 5) that gave rise to a primary cell culture (BC160). This method combines mechanical disaggregation and enzymatic digestion with hyaluronidase and collagenase. Moreover, the paper addresses common issues in isolating primary cultures, shedding light on the struggle against fibroblasts overgrowing cancer cell populations. To make primary cell lines a preferred model, it is essential to elaborate and categorise isolation methods, develop approaches to separate heterogeneous cultures and investigate factors influencing the establishment of primary cell lines.

2.
Rep Pract Oncol Radiother ; 28(3): 429-432, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37795403

RESUMO

Background: Clinical audits are an important tool to objectively assess clinical protocols, procedures, and processes and to detect deviations from good clinical practice. The main aim of this project is to determine adherence to a core set of consensus- based quality indicators and then to compare the institutions in order to identify best practices. Materials and methods: We conduct a multicentre, international clinical audit of six comprehensive cancer centres in Poland, Spain, Italy, Portugal, France, and Romania as a part of the project, known as IROCATES (Improving Quality in Radiation Oncology through Clinical Audits - Training and Education for Standardization). Results: Radiotherapy practice varies from country to country, in part due to historical, economic, linguistic, and cultural differences. The institutions developed their own processes to suit their existing clinical practice. Conclusions: We believe that this study will contribute to establishing the value of routinely performing multi-institutional clinical audits and will lead to improvement of radiotherapy practice at the participating centres.

3.
Rep Pract Oncol Radiother ; 28(2): 159-171, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37456709

RESUMO

Background: Cancer-associated fibroblasts (CAFs) are a diverse subset of cells, that is recently gaining in popularity and have the potential to become a new target for breast cancer (BC) therapy; however, broader research is required to understand their mechanisms and interactions with breast cancer cells. The goal of the study was to isolate CAFs from breast cancer tumour and characterise isolated cell lines. We concentrated on numerous CAF biomarkers that would enable their differentiation. Materials and methods: Flow cytometry, immunofluorescence, and reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR) were used to phenotype the primary CAFs. Results/Conclusions: According to our findings, there was no significant pattern in the classification of cancer-associated fibroblasts. The results of biomarkers expression were heterogeneous, thus no specific subtypes were identified. Furthermore, a comparison of cancer-associated fibroblasts derived from different BC subtypes (luminal A and B, triple-negative, HER2 positive) did not reveal any clear trend of expression.

4.
Sci Rep ; 13(1): 9092, 2023 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-37277546

RESUMO

The first-order statistical (FOS) and second-order texture analysis on basis of Gray-Level Co-occurence Matrix (GLCM) were obtained to assess metabolic, volumetric, statistical and radiomic parameters of cervical cancer in response to chemotherapy, recurrence and age of patients. The homogeneous group of 83 patients with histologically confirmed IIIC1-IVB stage cervical cancer were analyzed, retrospectively. Before and after chemotherapy, the advancement of the disease and the effectiveness of the therapy, respectively, were established using [18F] FDG PET/CT imaging. The statistically significant differences between pre- and post-therapy parameters were observed for SUVmax, SUVmean, TLG, MTV, asphericity (ASP, p = 0.000, Z > 0), entropy (E, p = 0.0000), correlation (COR, p = 0.0007), energy (En, p = 0.000) and homogeneity (H, p = 0.0018). Among the FOS parameters, moderate correlation was observed between pre-treatment coefficient of variation (COV) and patients' recurrence (R = 0.34, p = 0.001). Among the GLCM textural parameters, moderate positive correlation was observed for post-treatment contrast (C) with the age of patients (R = 0.3, p = 0.0038) and strong and moderate correlation was observed in the case of En and H with chemotherapy response (R = 0.54 and R = 0.46, respectively). All correlations were statistically significant. This study indicates the remarkable importance of pre- and post-treatment [18F] FDG PET statistical and textural GLCM parameters according to prediction of recurrence and chemotherapy response of cervical cancer patients.


Assuntos
Fluordesoxiglucose F18 , Neoplasias do Colo do Útero , Feminino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/tratamento farmacológico , Neoplasias do Colo do Útero/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Carga Tumoral
5.
Front Oncol ; 13: 1147593, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37188175

RESUMO

Aim: In the treatment of prostate cancer with radiation therapy, the addition of a simultaneous integrated boost (SIB) to the dominant intraprostatic lesions (DIL) may improve local control. In this study, we aimed to determine the optimal radiation strategy in a phantom model of prostate cancer using volumetric modulated arc therapy for stereotactic body radiotherapy (SBRT-VMAT) with a SIB of 1-4 DILs. Methods: We designed and printed a three-dimensional anthropomorphic phantom pelvis to simulate individual patient structures, including the prostate gland. A total of 36.25 Gy (SBRT) was delivered to the whole prostate. The DILs were irradiated with four different doses (40, 45, 47.5, and 50 Gy) to assess the influence of different SIB doses on dose distribution. The doses were calculated, verified, and measured using both transit and non-transit dosimetry for patient-specific quality assurance using a phantom model. Results: The dose coverage met protocol requirements for all targets. However, the dose was close to violating risk constraints to the rectum when four DILs were treated simultaneously or when the DILs were located in the posterior segments of the prostate. All verification plans passed the assumed tolerance criteria. Conclusions: Moderate dose escalation up to 45 Gy seems appropriate in cases with DILs located in posterior prostate segments or if there are three or more DILs located in other segments.

6.
J Pers Med ; 13(5)2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37240931

RESUMO

Modern communication and information technologies are rapidly being deployed at health care institutions around the world. Although these technologies offer many benefits, ensuring data protection is a major concern, and implementation of robust data protection measures is essential. In this context, health care providers and medical care facilities must frequently make difficult decisions and compromises between the need to provide effective medical care and the need to ensure data security and patient privacy. In the present paper, we describe and discuss key issues related to data protection systems in the setting of cancer care hospitals in Europe. We provide real-life examples from two European countries-Poland and the Czech Republic-to illustrate data protection issues and the steps being taking to address these questions. More specifically, we discuss the legal framework surrounding data protection and technical aspects related to patient authentication and communication.

7.
Am J Cancer Res ; 12(9): 4411-4427, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36225645

RESUMO

Cancer-associated fibroblasts are a highly heterogeneous group of cells whose phenotypes and gene alterations are still under deep investigation. As a part of tumor microenvironment, they are the focus of a growing number of studies. Cancer-associated fibroblasts might become a new target of breast cancer therapy, but still more tests and analyses are needed to understand mechanisms and interactions between them and breast cancer cells. The study aimed to isolate cancer associated fibroblasts from breast cancer tissue and to phenotype the isolated cell lines. We focused on various cancer-associated fibroblast characteristic biomarkers and those that might differentiate various cancer-associated fibroblasts' subtypes. Patients with a histological diagnosis of invasive breast cancer (diameter ≤15 mm) and qualified for primary surgical treatment were enrolled in the study. Cell lines were isolated from breast cancer biopsy. For the phenotyping, we used flow cytometry, immunofluorescence and RT-qPCR analysis. Based on our study, there was no indication of a clear pattern in the cancer-associated fibroblasts' classification. Results of cancer-associated fibroblasts expression were highly heterogeneous, and specific subtypes were not defined. Moreover, comparing cancer-associated fibroblasts divided into groups based on BC subtypes from which they were isolated also did not allow to notice of any clear pattern of expressions. In the future, a higher number of analyzed cancer-associated fibroblast cell lines should be investigated to find expression schemes.

8.
Rep Pract Oncol Radiother ; 27(4): 734-743, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36196410

RESUMO

Since the introduction of computed tomography for planning purposes in the 1970s, we have been observing a continuous development of different imaging methods in radiotherapy. The current achievements of imaging technologies in radiotherapy enable more than just improvement of accuracy on the planning stage. Through integrating imaging with treatment machines, they allow advanced control methods of dose delivery during the treatment. This article reviews how the integration of existing and novel forms of imaging changes radiotherapy and how these advances can allow a more individualised approach to cancer therapy. We believe that the significant challenge for the next decade is the continued integration of a range of different imaging devices into linear accelerators. These imaging modalities should show intra-fraction changes in body morphology and inter-fraction metabolic changes. As the use of these more advanced, integrated machines grows, radiotherapy delivery will become more accurate, thus resulting in better clinical outcomes: higher cure rates with fewer side effects.

9.
Rep Pract Oncol Radiother ; 27(2): 344-351, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36299375

RESUMO

FLASH radiotherapy (RT) is a technique involving the delivery of ultra-high dose rate radiation to the target. FLASH-RT has been shown to reduce radiation-induced toxicity in healthy tissues without compromising the anti-cancer effects of treatment compared to conventional radiation therapy. In the present article, we review the published data on FLASH-RT and discuss the current state of knowledge of this novel approach. We also highlight the technological constraints and complexity of FLASH-RT and describe the physics underlying this modality, particularly how technology supports energy transfer by ionising radiation (e.g., beam on/off sequence, pulse-energy load, intervals). We emphasise that current preclinical experience is mostly based on FLASH electrons and that clinical application of FLASH-RT is very limited. The incorporation of FLASH-RT into routine clinical radiotherapy will require the development of devices capable of producing FLASH photon beams.

10.
Biomedicines ; 10(7)2022 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-35884907

RESUMO

Gastric cancer (GC) is the fourth most common cancer in the world in terms of incidence and second in terms of mortality. Chemotherapy is the main treatment for GC. The greatest challenge and major cause of GC treatment failure is resistance to chemotherapy. As such, research is ongoing into molecular evaluation, investigating mechanisms, and screening therapeutic targets. Several mechanisms related to both the tumor cells and the tumor microenvironment (TME) are involved in resistance to chemotherapy. TME promotes the secretion of various inflammatory cytokines. Recent studies have revealed that inflammatory cytokines affect not only tumor growth, but also chemoresistance. Cytokines in TME can be detected in blood circulation and TME cells. Inflammatory cytokines could serve as potential biomarkers in the assessment of chemoresistance and influence the management of therapeutics in GC. This review presents recent data concerning research on inflammatory cytokines involved in the mechanisms of chemoresistance and provides new clues in GC treatment.

11.
Adv Radiat Oncol ; 7(4): 100956, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35865371

RESUMO

The current situation and management of Ukrainian patients at 2 European cancer care centers in Poland and Italy is described. Both centers admit refugees from the war in Ukraine.

12.
Life (Basel) ; 12(6)2022 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-35743890

RESUMO

In clinical radiotherapy, the most important aspects are the dose distribution in the target volume and healthy organs, including out-of-field doses in the body. Compared to photon beam radiation, dose distribution in electron beam radiotherapy has received much less attention, mainly due to the limited range of electrons in tissues. However, given the growing use of electron intraoperative radiotherapy and FLASH, further study is needed. Therefore, in this study, we determined out-of-field doses from an electron beam in a phantom model using two dosimetric detectors (diode E and cylindrical Farmer-type ionizing chamber) for electron energies of 6 MeV, 9 MeV and 12 MeV. We found a clear decrease in out-of-field doses as the distance from the field edge and depth increased. The out-of-field doses measured with the diode E were lower than those measured with the Farmer-type ionization chamber at each depth and for each electron energy level. The out-of-field doses increased when higher energy megavoltage electron beams were used (except for 9 MeV). The out-of-field doses at shallow depths (1 or 2 cm) declined rapidly up to a distance of 3 cm from the field edge. This study provides valuable data on the deposition of radiation energy from electron beams outside the irradiation field.

13.
Cancers (Basel) ; 14(11)2022 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-35681692

RESUMO

Hypo-fractionated stereotactic body radiation therapy (SBRT) is an effective treatment for prostate cancer (PCa). Although many studies have investigated the effects of SBRT on the prostate and adjacent organs, little is known about the effects further out-of-field. The aim of this study was to investigate, both in vitro and in a quasi-humanoid phantom, the biological effects (using a dose-scaling approach) of radiation in the out-of-field peripheral organs delivered by 6 MV volumetric modulated arc therapy (VMAT) SBRT in a prostate cancer model. Healthy prostate cells were irradiated in a phantom at locations corresponding to the prostate, intestine, lung, thyroid, and brain. Seven 10 Gy fractions of VMAT SBRT were delivered to the target in a single session without intermission (scaled-up method). Radiochromic films were used to measure the doses. The radiobiological response was assessed by measuring DNA breaks, the cell survival fraction, and differences in gene expression profile. Our results showed a strong, multiparametric radiobiological response of the cells in the prostate. Outside of the radiation field, the highest doses were observed in the intestine and lung. A small increase (not statistically significant) in DNA damage and cell death was observed in the intestines. Several gene groups (cell cycle, DNA replication) were depleted in the lung and thyroid (DNA replication, endocytosis), but further analysis revealed no changes in the relevant biological processes. This study provides extensive evidence of the types and extent of radiobiological responses during VMAT SBRT in a prostate cancer model. Additional research is needed to determine whether the radiobiological effects observed in the peripheral organs are validated in a clinical context.

14.
J Contemp Brachytherapy ; 14(2): 205-214, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35494185

RESUMO

Purpose: One of the main challenges in facial region brachytherapy is fixation of vendor-delivered standard applicators. Reproducibility can be maintained; however, there are frequent problems with applicator fitting to the skin surface in pleated regions. Manually prepared individual moulds require technological facilities and highly-trained staff. This article presents 3D-printed applicator preparation for a particular patient skin brachytherapy, using low-cost equipment and free software. We described applicator preparation in a step-by-step workflow. Material and methods: This study demonstrated preparation of a skin brachytherapy applicator for a challenging recurrent tumor located in the nose bridge. During first visit of patient, fiducial markers were placed to enclose treated region. Patient was computed tomography (CT)-scanned, and reconstruction of target volume and surrounding organs at risk (OARs) were performed using treatment planning system (TPS). In TPS on patient's surface, a 1-cm thick bolus was added as a body of applicator. Inside the bolus, source paths were designed, and pre-plan was prepared. Using Beben - DICOM to standard triangle language (STL) software, the body of applicator and source-paths from pre-planning was transformed into an STL file, which was used as a solid definition in 3D printing. Results: The printed applicator fitted very well, and its' placement was quickly consistent regarding placing and securing. CTV was slightly broader in treatment plan (0.34 cm3 vs. 0.31 cm3), and doses given to CTV were lower, except for V150, which was higher for the realized plan (1.15% vs. 1.83%). All reported doses to OARs were lower in the realized plan. Conclusions: A low-cost 3D printer and widely available PLA filaments seem feasible to produce individual contact applicators for skin brachytherapy. Beben - DICOM to STL software and presented workflow appear to be convenient and simple tool.

15.
Life (Basel) ; 12(5)2022 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-35629296

RESUMO

The aim of the study was to determine the influence of a key treatment plan and beam parameters on overall dose distribution and on doses in organs laying in further distance from the target during prostate SBRT. Multiple representative treatment plans (n = 12) for TrueBeam and CyberKnife were prepared and evaluated. Nontarget doses were measured with anionization chamber, in a quasi-humanoid phantom at four sites corresponding to the intestines, right lung, thyroid, and head. The following parameters were modified: radiotherapy technique, presence or not of a flattening filter, degree of modulation, and use or not of jaw tracking function for TrueBeam and beam orientation set-up, optimization techniques, and number of MUs for CyberKnife. After usual optimization doses in intestines (near the target) were 0.73% and 0.76%, in head (farthest from target) 0.05% and 0.19% for TrueBeam and CyberKnife, respectively. For TrueBeam the highest peripheral (head, thyroid, lung) doses occurred for the VMAT with the flattening filter while the lowest for 3DCRT. For CyberKnife the highest doses were for gantry with caudal direction beams blocked (gantry close to OARs) while the lowest was the low modulated VOLO optimization technique. The easiest method to reduce peripheral doses was to combine FFF with jaw tracking and reducing monitor units at TrueBeam and to avoid gantry position close to OARs together with reduction of monitor units at CyberKnife, respectively. The presented strategies allowed to significantly reduce out-of-field and nontarget doses during prostate radiotherapy delivered with TrueBeam and CyberKnife. A different approach was required to reduce peripheral doses because of the difference in dose delivery techniques: non-coplanar using CyberKnife and coplanar using TrueBeam, respectively.

16.
Life (Basel) ; 12(5)2022 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-35629389

RESUMO

No clear criteria have yet been established to guide decision-making for patient selection and the optimal timing of adaptive radiotherapy (ART) based on image-guided radiotherapy (IGRT). We have developed a novel protocol­the Best for Adaptive Radiotherapy (B-ART) protocol­to guide patient selection for ART. The aim of the present study is to describe this protocol, to evaluate its validity in patients with head and neck (HN) cancer, and to identify the anatomical and clinical predictors of the need for replanning. We retrospectively evaluated 82 patients with HN cancer who underwent helical tomotherapy (HT) and subsequently required replanning due to soft tissue changes upon daily MVCT. Under the proposed criteria, patients with anatomical changes >3 mm on three to four consecutive scans are candidates for ART. We compared the volumes on the initial CT scan (iCT) and the replanning CT (rCT) scan for the clinical target volumes (CTV1, referring to primary tumor or tumor bed and CTV2, metastatic lymph nodes) and for the parotid glands (PG) and body contour (B-body). The patients were stratified by primary tumor localization, clinical stage, and treatment scheme. The main reasons for replanning were: (1) a planning target volume (PTV) outside the body contour (n = 70; 85.4%), (2) PG shrinkage (n = 69; 84.1%), (3) B-body deviations (n = 69; 84.1%), and (4) setup deviations (n = 40; 48.8%). The replanning decision was made, on average, during the fourth week of treatment (n = 47; 57.3%). The mean reductions in the size of the right and left PG volumes were 6.31 cc (20.9%) and 5.98 cc (20.5%), respectively (p < 0.001). The reduction in PG volume was ≥30% in 30 patients (36.6%). The volume reduction in all of the anatomical structures was statistically significant. Four variables­advanced stage disease (T3−T4), chemoradiation, increased weight loss, and oropharyngeal localization­were significantly associated with the need for ART. The B-ART protocol provides clear criteria to eliminate random errors, and to allow for an early response to relevant changes in target volumes.

17.
Life (Basel) ; 12(4)2022 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-35455003

RESUMO

(1) Current breast-conserving therapy for breast cancer consists of a combination of many consecutive treatment modalities. The most crucial goal of postoperative treatment is to eradicate potentially relapse-forming residual cancerous cells within the tumor bed. To achieve this, the HDR brachytherapy boost standardly added to external beam radiotherapy was enhanced with an initial thermal boost. This study presents an original thermal boost technique developed in the clinic. (2) A detailed point-by-point description of thermal boost application is presented. Data on proper patient selection, microwave thermal boost planning, and interstitial hyperthermia treatment delivery are supported by relevant figures and schemes. (3) Out of 1134 breast cancer patients who were administered HDR brachytherapy boost in the tumor bed, 262 were also pre-heated interstitially without unexpected complications. The results are supported by two example cases of hyperthermia planning and delivery. (4) Additional breast cancer interstitial thermal boost preceding HDR brachytherapy boost as a part of combined treatment in a unique postoperative setting was feasible, well-tolerated, completed in a reasonable amount of time, and reproducible. A commercially available interstitial hyperthermia system fit and worked well with standard interstitial brachytherapy equipment.

18.
Radiol Oncol ; 56(2): 259-266, 2022 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-35344646

RESUMO

BACKGROUND: Hypofractionated stereotactic body radiation therapy (SBRT) for prostate cancer (PCa) can be delivered with the robot-assisted CyberKnife (CK) system or on a linear accelerator using dynamic intensity-modulated radiotherapy (IMRT) or volumetric arc radiotherapy (VMAT). This retrospective study was performed to determine whether CK offers better dose distribution than IMRT and/or VMAT. MATERIALS AND METHODS: Treatment plans for three techniques were prepared using the same treatment parameters (36.35 Gy, 7.25 Gy/fr). We evaluated target coverage, conformity index (CI), homogeneity index (HI), gamma index (GI), and organs at risk (OAR) constraints. RESULTS: The mean planning target volume (PTV) dose for CK (39.58 Gy) was significantly greater than VMAT or IMRT (both 36.25 Gy). However, CK resulted in a wider dose range (31.48 to 45.89 Gy) vs. VMAT and IMRT (34.6-38.76 Gy). The mean dose to the rectum (V36Gy, mm3) was significantly lower (p < 0.001) in the CK plans (219.78 vs. 519.59 and 422.62, respectively). The mean bladder dose (V37Gy, mm3) was significantly greater for CK (3256 vs. 1090.75 for VMAT and 4.5 for IMRT (p < 0.001). CK yielded significantly better CI (1.07 vs. 1.17 and 1.25 for VMAT and IMRT, respectively; p < 0.01) and HI values (1.27 vs. 1.07 and 1.04; p < 0.01). GI values for the δd = 3mm, δ% = 3% criteria were 99.86 (VMAT), 99.07 (IMRT) and 99.99 (CK). For δd = 2mm, δ% = 2%, the corresponding values were 98.3, 93.35, and 97.12, respectively. CONCLUSIONS: For most variables, CK was superior to both VMAT and IMRT. However, dynamic IMRT techniques, especially VMAT, do not differ significantly from CK plans and are therefore acceptable alternatives to CyberKnife.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Humanos , Masculino , Aceleradores de Partículas , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos
19.
Life (Basel) ; 12(3)2022 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-35330145

RESUMO

Recent comparison of an ultra-hypofractionated radiotherapy (UF-RT) boost to a conventionally fractionated (CF-RT) option showed similar toxicity and disease control outcomes. An analysis of the treatment plans for these patients is needed for evaluating calculated doses for different organs, treatment beam-on time, and requirements for human and financial resources. Eighty-six plans for UF-RT and 93 plans for CF-RT schemes were evaluated. The biologically equivalent dose, EQD2, summed for the first phase and the boost, was calculated for dose-volume parameters for organs at risk (OARs), as well as for the PTV1. ArcCHECK measurements for the boost plans were used for a comparison of planned and delivered doses. Monitor units and beam-on times were recorded by the Eclipse treatment planning system. Statistical analysis was performed with a significance level of 0.05. Dosimetric parameter values for OARs were well within tolerance for both groups. EQD2 for the PTV1 was on average 84 Gy for UF-RT patients and 76 Gy for CF-RT patients. Gamma passing rate for planned/delivered doses comparison was above 98% for both groups with 3 mm/3% distance to agreement/dose difference criteria. Total monitor units per fraction were 647 ± 94 and 2034 ± 570 for CF-RT and UF-RT, respectively. The total delivery time for boost radiation for the patients in the UF-RT arm was, on average, four times less than the total time for a conventional regimen with statistically equal clinical outcomes for the two arms in this study.

20.
J Appl Clin Med Phys ; 23(4): e13514, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35104047

RESUMO

Our understanding of low dose, out-of-field radiation and their radiobiological effects are limited, in part due to the rapid technological advances in external beam radiotherapy, especially for non-coplanar and dynamic techniques. Reliable comparisons of out-of-field doses produced by advanced radiotherapy techniques are difficult due to the limitations of commercially available phantoms. There is a clear need for a functional phantom to accurately measure the dosimetric and radiobiological characteristics of out-of-field doses, which would in turn allow clinicians and medical physicists to optimize treatment parameters. We designed, manufactured, and tested the performance of a quasi-humanoid (Q-H) adult phantom. To test the physics parameters, we used computed tomography (CT) scans of assembled Q-H phantom. Static open field and dynamic techniques were measured both in- and out-of-field with ionization chambers and radiochromic films for two configurations (full solid and with water-filled containers). In the areas simulating soft tissues, lung, and bones, median Hounsfield units and densities were, respectively: 129.8, -738.7, 920.8 HU and 1.110, 0.215, 1.669 g/cm3 . Comparison of the measured to treatment planning systems (TPS) in-field dose values for the sample volumetric arc therapy (VMAT) (6 MV flattening filter-free (FFF)) plan, 96.4% of analyzed points passed the gamma evaluation criteria (L2%/2 mm, threshold (TH) 10%) and less than 1.50% for point dose verification. In the two phantom configurations: full poly(methyl) methacrylate (PMMA) and with water container, the off-axis median doses for open field, relative to the central axis of the beam (CAX) were similar, respectively: 0.900% versus 0.907% (15 cm distance to CAX); 0.096% versus 0.120% (35 cm); 0.018% versus 0.018% (52 cm); 0.009% versus 0.008% (74 cm). For VMAT 6 MV FFF, doses relative the CAX were, respectively: 0.667% (15 cm), 0.062% (35 cm), 0.019% (52 cm), 0.016% (74 cm). The Q-H phantom meets the International Commission on Radiation Units and Measurements (ICRU) and American Association of Physicists in Medicine (AAPM) recommended phantom criteria, providing medical physicists with a reliable, comprehensive system to perform dose calculation and measurements and to assess the impact on radiobiological response and on the risk of secondary tumor induction.


Assuntos
Radioterapia de Intensidade Modulada , Adulto , Humanos , Imagens de Fantasmas , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...