Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
2.
J Vitreoretin Dis ; 6(2): 132-137, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37008664

RESUMO

Purpose: An alternative ocular antiseptic is needed for patients who do not tolerate povidone-iodine (PI). The purpose of this study is to compare the antimicrobial effect of hypochlorous acid (HA) 0.01% with PI 5% applied topically to the ocular surface. Methods: Swabs of the inferior conjunctiva and posterior lower eyelid margin of 40 patients were taken from both eyes and plated onto blood agar plates. One eye was treated with HA and the other with PI, and swabs were taken after 1-minute exposure. The eye treated with PI was rinsed with sterile saline and another swab was taken. Colony-forming units (CFUs) were recorded after 2 days. Patients rated the level of irritation after treatment in each eye. Results: HA and PI both gave significant reduction in CFUs from baseline (P < .001 for HA and P = .002 for PI). The mean reduction in logCFU ± 95% CI was 0.850 ± 0.387 or greater for HA and 0.749 ± 0.385 or greater for PI; this was equivalent to a mean reduction of 7.1-fold or greater or 86% or greater (95% CI, 66%-94%) for HA and 5.6-fold or greater or 82% or greater (95% CI, 57%-93%) for PI. CFUs increased in 17 eyes after saline rinse. PI caused substantial irritation in 31 of the 40 participants, whereas no individuals had any irritation from topical HA. Conclusions: Both HA and PI were effective in reducing ocular bacterial load. Unlike PI, HA was not irritating to the eye. Saline rinse after topical PI may increase bacterial counts in some individuals.

3.
Curr Eye Res ; 45(1): 1-6, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31380714

RESUMO

Purpose/Aim of the study: Measured intraocular pressure (IOP) after corneal incisions may not be reflective of the true IOP because of changes in corneal biomechanical properties. The purpose of this study is to investigate the effect of various corneal incisions on pneumotonometer accuracy in enucleated porcine eyes.Materials and Methods: A pneumotonometer was used to measure IOP (IOPp) at manometrically controlled pressure levels of 10, 20, 30 and 40 mmHg in enucleated porcine eyes. IOP measurements at each level were repeated after one of the following corneal incisions: radial keratotomy (8 eyes), lamellar dissection (10 eyes), clear cornea standard phacoemulsification incisions (10 eyes). The pneumotonometer error, defined as the difference between IOPp and manometric pressure (IOPm), was calculated for each pressure level. The error before the corneal incisions was compared to the error after the corneal incisions to assess the accuracy of the pneumotonometer.Results: The pneumotonometer underestimates true IOP at all pressure levels, both before and after the corneal procedures. There was a statistically significant greater underestimation of IOP after radial keratotomy incisions at pressure levels of 20, 30 and 40 mmHg (p = .013, 0.004, and 0.002, respectively). There was no statistically significant difference in the amount of pneumotonometer underestimation error after lamellar dissection or standard cataract incisions.Conclusion: The pneumotonometer underestimates true IOP in enucleated porcine eyes at all pressure levels between 10-40 mmHg. Radial keratotomy incisions caused a statistically significant greater underestimation error in pneumotonometry measurements at pressures of 20-40 mmHg. Lamellar dissection and clear corneal cataract incisions did not cause an additional error in pneumotonometry measurements in enucleated porcine eyes.


Assuntos
Córnea/cirurgia , Glaucoma/diagnóstico , Pressão Intraocular/fisiologia , Ceratotomia Radial/métodos , Tonometria Ocular/instrumentação , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Glaucoma/fisiopatologia , Glaucoma/cirurgia , Período Pós-Operatório , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA