Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Perinatol ; 44(2): 266-272, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38007593

RESUMO

OBJECTIVE: To investigate a novel servo pressure (SP) setting during high-frequency jet ventilation (HFJV) for a lung protective strategy in a neonatal model of acute respiratory distress. STUDY DESIGN: Comparison of efficacy between variable (standard) and fixed SP settings in a randomized animal study using rabbits (n = 10, mean weight = 1.80 kg) with surfactant deficiency by repeated lung lavages. RESULTS: Rabbits in the fixed SP group had greater peak inspiratory pressure, SP, minute volume, pH, and PaO2, and lower PaCO2 after lung lavage than the variable SP group. Lung volume monitoring with electrical impedance tomography showed that fixed SP reduced the decline of the global lung tidal variation at 30 min after lung lavage (-17.4% from baseline before lavage) compared to variable SP (-44.9%). CONCLUSION: HFJV with fixed SP significantly improved gas exchange and lung volumes compared to variable SP. Applying a fixed SP may have important clinical implications for patients receiving HFJV.


Assuntos
Ventilação em Jatos de Alta Frequência , Ventilação de Alta Frequência , Surfactantes Pulmonares , Animais , Humanos , Coelhos , Tensoativos , Pulmão , Medidas de Volume Pulmonar , Respiração Artificial/métodos
2.
Crit Care Explor ; 3(2): e0338, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33604579

RESUMO

OBJECTIVES: Effective treatment options for surfactant therapy in acute respiratory distress syndrome and coronavirus disease 2019 have not been established. To conduct preclinical studies in vitro and in vivo to evaluate efficiency, particle size, dosing, safety, and efficacy of inhaled surfactant using a breath-synchronized, nebulized delivery system in an established acute respiratory distress syndrome model. DESIGN: Preclinical study. SETTING: Research laboratory. SUBJECTS: Anesthetized pigs. INTERVENTION: In vitro analysis included particle size distribution and inhaled dose during simulated ventilation using a novel breath-synchronized nebulizer. Physiologic effects of inhaled aerosolized surfactant (treatment) were compared with aerosolized normal saline (control) in an adult porcine model (weight of 34.3 ± 0.6 kg) of severe acute respiratory distress syndrome (Pao2/Fio2 <100) with lung lavages and ventilator-induced lung injury during invasive ventilation. MEASUREMENTS AND MAIN RESULTS: Mass median aerosol diameter was 2.8 µm. In vitro dose delivered distal to the endotracheal tube during mechanical ventilation was 85% ± 5%. Nebulizers were functional up to 20 doses of 108 mg of surfactant. Surfactant-treated animals (n = 4) exhibited rapid improvement in oxygenation with nearly full recovery of Pao2/Fio2 (~300) and end-expiratory lung volumes with nominal dose less than 30 mg/kg of surfactant, whereas control subjects (n = 3) maintained Pao2/Fio2 less than 100 over 4.5 hours with reduced end-expiratory lung volume. There was notably greater surfactant phospholipid content and lower indicators of lung inflammation and pathologic lung injury in surfactant-treated pigs than controls. There were no peridosing complications associated with nebulized surfactant, but surfactant-treated animals had progressively higher airway resistance post treatment than controls with no differences in ventilation effects between the two groups. CONCLUSIONS: Breath-synchronized, nebulized bovine surfactant appears to be a safe and feasible treatment option for use in coronavirus disease 2019 and other severe forms of acute respiratory distress syndrome.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...