Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Pan Afr Med J ; 25: 50, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28250874

RESUMO

INTRODUCTION: S. aureus is a Gram positive bacterium which is responsible for a wide range of infections. This pathogen has also the ability to adhere to biotic or abiotic surface such as central venous catheter (CVC) and to produce a biofilm. The aim of this study was to evaluate the effect of hexadecyltrimethyl ammonium bromide (HTAB) and Hexadecylbetainate chloride (HBC) on Staphylococcus aureus adherence to the catheter tubing and on bacteria growth. METHODS: Broth microdilution method was used to determine the Minimal Inhibitory Concentration (MIC). The detection of slime production was done by Congo Red Agar method, and the adherence of bacteria to the catheter tubing was evaluated by the enumeration of bacteria on plate counts. RESULTS: The results of this study showed that the MICs of HTAB were ranged from 0.125 to 0.5 µg/mL, and those of HBC fluctuated between 2 to 8 µg/mL. HTAB and HBC inhibited bacteria adhesion on the surface of the catheter tubing. CONCLUSION: This study showed that HTAB and HBC can prevent the adherence of S. aureus strains to the surface of catheter tubing, suggesting that they could be used to prevent the risk of catheter related bloodstream infections.


Assuntos
Betaína/análogos & derivados , Infecções Relacionadas a Cateter/prevenção & controle , Compostos de Cetrimônio/farmacologia , Staphylococcus aureus/efeitos dos fármacos , Anti-Infecciosos Locais/administração & dosagem , Anti-Infecciosos Locais/farmacologia , Betaína/administração & dosagem , Betaína/farmacologia , Biofilmes/efeitos dos fármacos , Infecções Relacionadas a Cateter/microbiologia , Catéteres/microbiologia , Cetrimônio , Compostos de Cetrimônio/administração & dosagem , Humanos , Testes de Sensibilidade Microbiana , Infecções Estafilocócicas/prevenção & controle
2.
Talanta ; 76(3): 540-7, 2008 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-18585319

RESUMO

A silver-based solid carbon paste electrode was developed for use as a detector in ion chromatography (IC) for the sensitive determination of iodide in real samples. Micro- and nano-particles of silver were investigated for the fabrication of different electrodes. The iodide assay was based on IC with amperometric detection (IC-AD) at a silver composite electrode polarized at +0.080 V versus Ag/AgCl. Free iodide and organoiodide compounds were studied. The detection process was characterized by studying the redox behavior of iodide ions at both silver and silver composite electrodes by cyclic voltammetry (CV). The presence of iodide ions in solution was found to considerably facilitate metallic silver oxidation, with response currents directly related to iodide concentration. The calibration curve at the selected silver carbon paste electrode was linear in the concentration range comprised between 0.635 microg/L and 63.5 microg/L iodide. The relative standard deviation (R.S.D.) for successive injections was below 3% for all iodide standard solutions investigated. The limit of detection (LOD) was 0.47 microg/L (3.7 nmol/L) for an injection volume of 20 microL, i.e. 74 fmol injected. The IC-AD method was successfully applied to the determination of iodide in complex real samples such as table salts, sea products and iodide bound drug compounds. The analytical accuracy was verified by the assay of iodide in milk powder from an iodide certified reference material (CRM) Community Bureau of Reference (BCR) 150.


Assuntos
Cromatografia por Troca Iônica/instrumentação , Iodetos/análise , Eletrodos Seletivos de Íons/normas , Carbono , Cromatografia por Troca Iônica/normas , Nanopartículas Metálicas , Oxirredução , Preparações Farmacêuticas/química , Prata , Cloreto de Sódio na Dieta/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA