1.
Radiat Prot Dosimetry ; 169(1-4): 353-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26743261

RESUMO

Modern X-ray units register the air kerma-area product, PKA, with a built-in KAP meter. Some KAP meters show an energy-dependent bias comparable with the maximum uncertainty articulated by the IEC (25 %), adversely affecting dose-optimisation processes. To correct for the bias, a reference KAP meter calibrated at a standards laboratory and two calibration methods described here can be used to achieve an uncertainty of <7 % as recommended by IAEA. A computational model of the reference KAP meter is used to calculate beam quality correction factors for transfer of the calibration coefficient at the standards laboratory, Q0, to any beam quality, Q, in the clinic. Alternatively, beam quality corrections are measured with an energy-independent dosemeter via a reference beam quality in the clinic, Q1, to beam quality, Q Biases up to 35 % of built-in KAP meter readings were noted. Energy-dependent calibration factors are needed for unbiased PKA Accurate KAP meter calibration as a prerequisite for optimisation in projection radiography.


Assuntos
Algoritmos , Artefatos , Melhoria de Qualidade/normas , Dosímetros de Radiação/normas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/instrumentação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/normas , Calibragem/normas , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Internacionalidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Radiat Prot Dosimetry ; 169(1-4): 398-404, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26567322

RESUMO

Advanced model-based iterative reconstruction algorithms in quantitative computed tomography (CT) perform automatic segmentation of tissues to estimate material properties of the imaged object. Compared with conventional methods, these algorithms may improve quality of reconstructed images and accuracy of radiation treatment planning. Automatic segmentation of tissues is, however, a difficult task. The aim of this work was to develop and evaluate an algorithm that automatically segments tissues in CT images of the male pelvis. The newly developed algorithm (MK2014) combines histogram matching, thresholding, region growing, deformable model and atlas-based registration techniques for the segmentation of bones, adipose tissue, prostate and muscles in CT images. Visual inspection of segmented images showed that the algorithm performed well for the five analysed images. The tissues were identified and outlined with accuracy sufficient for the dual-energy iterative reconstruction algorithm whose aim is to improve the accuracy of radiation treatment planning in brachytherapy of the prostate.


Assuntos
Braquiterapia/métodos , Reconhecimento Automatizado de Padrão/métodos , Pelve/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radioterapia Guiada por Imagem/métodos , Humanos , Masculino , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
3.
Radiat Prot Dosimetry ; 169(1-4): 405-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26454270

RESUMO

New paradigms for parallel programming have been devised to simplify software development on multi-core processors and many-core graphical processing units (GPU). Despite their obvious benefits, the parallelisation of existing computer programs is not an easy task. In this work, the use of the Open Multiprocessing (OpenMP) and Open Computing Language (OpenCL) frameworks is considered for the parallelisation of the model-based iterative reconstruction algorithm DIRA with the aim to significantly shorten the code's execution time. Selected routines were parallelised using OpenMP and OpenCL libraries; some routines were converted from MATLAB to C and optimised. Parallelisation of the code with the OpenMP was easy and resulted in an overall speedup of 15 on a 16-core computer. Parallelisation with OpenCL was more difficult owing to differences between the central processing unit and GPU architectures. The resulting speedup was substantially lower than the theoretical peak performance of the GPU; the cause was explained.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Modelos Biológicos , Modelos Estatísticos , Software , Simulação por Computador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
4.
Phys Med Biol ; 59(23): 7195-210, 2014 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-25369212

RESUMO

The air kerma-area product (KAP) is used for settings of diagnostic reference levels. The International Atomic Energy Agency (IAEA) recommends that doses in diagnostic radiology (including the KAP values) be estimated with an accuracy of at least ± 7% (k = 2). Industry standards defined by the International Electrotechnical Commission (IEC) specify that the uncertainty of KAP meter measurements should be less than ± 25% (k = 2). Medical physicists willing to comply with the IAEA's recommendation need to apply correction factors to KAP values reported by x-ray units. The aim of this work is to present and evaluate a calibration method for built-in KAP meters on clinical x-ray units. The method is based on (i) a tandem calibration method, which uses a reference KAP meter calibrated to measure the incident radiation, (ii) measurements using an energy-independent ionization chamber to correct for the energy dependence of the reference KAP meter, and (iii) Monte Carlo simulations of the beam quality correction factors that correct for differences between beam qualities at a standard laboratory and the clinic. The method was applied to the KAP meter in a Siemens Aristos FX plus unit. It was found that values reported by the built-in KAP meter differed from the more accurate values measured by the reference KAP meter by more than 25% for high tube voltages (more than 140 kV) and heavily filtered beams (0.3 mm Cu). Associated uncertainties were too high to claim that the IEC's limit of 25% was exceeded. Nevertheless the differences were high enough to justify the need for a more accurate calibration of built-in KAP meters.


Assuntos
Doses de Radiação , Equipamentos e Provisões para Radiação/normas , Calibragem , Valores de Referência
5.
Phys Med Biol ; 58(4): 771-85, 2013 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-23322084

RESUMO

Dosimetric accuracy of radiation treatment planning in brachytherapy depends on knowledge of tissue composition. It has been speculated that soft tissues can be decomposed to water, lipid and protein. The aim of our work is to evaluate the accuracy of such tissue decomposition. Selected abdominal soft tissues, whose average elemental compositions were taken from literature, were decomposed using dual energy computed tomography to water, lipid and protein via the three-material decomposition method. The quality of the decomposition was assessed using relative differences between (i) mass energy absorption and (ii) mass energy attenuation coefficients of the analyzed and approximated tissues. It was found that the relative differences were less than 2% for photon energies larger than 10 keV. The differences were notably smaller than the ones for water as the transport and dose scoring medium. The choice of the water, protein and lipid triplet resulted in negative elemental mass fractions for some analyzed tissues. As negative elemental mass fractions cannot be used in general purpose particle transport computer codes using the Monte Carlo method, other triplets should be used for the decomposition. These triplets may further improve the accuracy of the approximation as the differences were mainly caused by the lack of high-Z materials in the water, protein and lipid triplet.


Assuntos
Absorciometria de Fóton/métodos , Braquiterapia/métodos , Lipídeos/química , Fótons/uso terapêutico , Proteínas/química , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Água/química , Absorção , Algoritmos , Humanos , Modelos Estatísticos , Método de Monte Carlo , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Distribuição Tecidual
6.
Radiat Prot Dosimetry ; 144(1-4): 611-4, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21186209

RESUMO

Silicon energy deposition spectrometer Liulin was primarily developed for cosmic radiation monitoring onboard spacecrafts. Nowadays, Liulin type detectors are also used to characterise radiation field on board aircraft, at alpine observatories and behind the shielding of heavy ion accelerators. In this work, experiments and calibrations performed in these radiation fields are presented and the method developed for calculation of ambient dose equivalent H*(10) on board aircraft is described. Since 2001, a simple method employing the energy deposition spectra had been used to determine H*(10) on board aircraft but, in 2004, it became clear that the resulting values were strongly biased at locations close to Earth's equator. An improved method for the determination of H*(10) on board aircraft using the Liulin detector was developed. It took into account the composition of the radiation field via the ratio of absorbed doses D(low) and D(neut) reflecting the contributions from low-LET particles and neutrons, respectively. It resulted in much better agreement with the EPCARD computer code for all aircraft locations; relative differences were within 11 % for low-LET and 20 % for neutron components of H*(10).


Assuntos
Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Proteção Radiológica/instrumentação , Proteção Radiológica/métodos , Análise Espectral/instrumentação , Aeronaves , Algoritmos , Calibragem , Radiação Cósmica , República Tcheca , Humanos , Modelos Estatísticos , Nêutrons , Aceleradores de Partículas , Doses de Radiação , Silício/química , Dióxido de Silício/química , Astronave , Análise Espectral/métodos
7.
Radiat Prot Dosimetry ; 144(1-4): 684-7, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21081521

RESUMO

Individual monitoring of aircrew of airline operators registered in the Czech Republic has been performed since 1998. In this work, annual effective doses and annual collective effective doses of aircrew from occupational exposure in the period from 1998 to 2008 are presented, methods used for their evaluation and verification are described, and general trends observed in the data are discussed. Annual effective doses were calculated using the computer code CARI from flight schedules provided by airline operators and typical flight profiles. The method was verified via a comparison with (i) measurements using different types of detectors and (ii) calculations using the CARI and EPCARD codes with actual flight data. It was found that average annual effective doses in the period from 1998 to 2008 were in the range from 1.2 to 2.0 mSv and followed the trend of the solar cycle. Annual collective effective doses increased from 1.4 manSv in 1998 to 4.1 manSv in 2008 as the number of aircrew increased from 857 to 2158 during this period. Combined relative uncertainties (coverage factor ) of reported individual and collective effective doses were ∼ 25 %, which is well within the range given by the factor of 1.5. More work is needed to achieve a higher accuracy of this estimate.


Assuntos
Aviação/métodos , Exposição Ocupacional/prevenção & controle , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Medicina Aeroespacial/métodos , Aeronaves , Altitude , Calibragem , Radiação Cósmica , República Tcheca , Humanos , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes
8.
Phys Med Biol ; 52(4): 1157-70, 2007 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-17264377

RESUMO

The Monte Carlo method was used to study the dependence of the calibration coefficient on the tube voltage, beam aperture and reference plane in simplified over-couch geometries modelling VacuTec's type 70157 KAP-meter both with and without an additional filter. The MCNP5 code was used to calculate (i) energy imparted to air cavities of the KAP-meter and (ii) spatial distribution of air collision kerma at entrance and exit planes of the KAP-meter and at a plane close to the patient. From these data, the air kerma area product and calibration coefficient were calculated and their dependence on the tube voltage and beam aperture was analysed. It was found that the variation of the calibration coefficient as a function of tube voltage was up to 40% when the additional filter was used. The additional filter placed closely in front of the KAP-meter decreased the calibration coefficient for the patient plane by about 10% compared to the ideal additional filter. The effect of the beam aperture was small at the patient plane and negligible for the exit plane.


Assuntos
Método de Monte Carlo , Monitoramento de Radiação , Radiografia/métodos , Radiometria/métodos , Ecrans Intensificadores para Raios X , Calibragem , Filtração , Humanos , Modelos Teóricos , Doses de Radiação , Radiografia/instrumentação , Radiometria/instrumentação , Fatores de Risco