Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nanotechnology ; 35(5)2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37879329

RESUMO

Inkjet-printable ink formulated with graphene oxide (GO) offers several advantages, including aqueous dispersion, low cost, and environmentally friendly production. However, water-based GO ink encounters challenges such as high surface tension, low wetting properties, and reduced ink stability over prolonged storage time. Alkali lignin, a natural surfactant, is promising in improving GO ink's stability, wettability, and printing characteristics. The concentration of surfactant additives is a key factor in fine-tuning GO ink's stability and printing properties. The current study aims to explore the detailed effects of alkali lignin concentration and optimize the overall properties of graphene oxide (GO) ink for drop-on-demand thermal inkjet printing. A meander-shaped temperature sensor electrode was printed using the optimized GO ink to demonstrate its practical applicability for commercial purposes. The sensing properties are evaluated using a simple experimental setup across a range of temperatures. The findings demonstrate a significant increase in zeta potential by 25% and maximum absorption by 84.3%, indicating enhanced stability during prolonged storage with an optimized alkali lignin concentration compared to the pure GO dispersions. The temperature sensor exhibits a remarkable thermal coefficient of resistance of 1.21 within the temperature range of 25 °C-52 °C, indicative of excellent sensitivity, response, and recovery time. These results highlight the potential of alkali lignin as a natural surfactant for improving the performance and applicability of inkjet-printable GO inks in various technological applications.

2.
HardwareX ; 15: e00441, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37396412

RESUMO

Wearable technology, such as electronic components integrated into clothing or worn as accessories, is becoming increasingly prevalent in fields like healthcare and biomedical monitoring. These devices allow for continuous monitoring of important biomarkers for medical diagnosis, monitoring of physiological health, and evaluation. However, an open-source wearable potentiostat is a relatively new technology that still faces several design limitations such as short battery lifetime, bulky size, heavy weight, and the requirement for a wire for data transmission, which affects comfortability during long periods of measurement. In this work, an open-source wearable potentiostat device named We-VoltamoStat is developed to allow interested parties to use and modify the device for creating new products, research, and teaching purposes. The proposed device includes improved and added features, such as wireless real-time signal monitoring and data collection. It also has an ultra-low power consumption battery estimated to deliver 15 mA during operating mode for 33 h and 20 min and 5 mA during standby mode for 100 h without recharging. Its convenience for wearable applications, tough design, and compact size of 67x54x38 mm make it suitable for wearable applications. Cost-effectiveness is another advantage, with a price less than 120 USD. Validation performance tests indicate that the device has good accuracy, with an R2 value of 0.99 for linear regression of test accuracy on milli-, micro-, and nano-Ampere detection. In the future, it is recommended to improve the design and add more features to the device, including new applications for wearable potentiostats.

3.
Surg Neurol Int ; 14: 158, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37151468

RESUMO

Background: Brain cooling therapy is one of the subjects of interest, and currently, data on direct brain cooling are lacking. Hence, the objective is to investigate the clinical outcomes and discuss the thermodynamics aspect of direct brain cooling on severely injured brain patients. Methods: This pilot study recruited the severely injured brain patients who were then randomized to either a direct brain cooling therapy group using a constant cooling temperature system or a control group. All studied patients must be subjected to an emergency neurosurgical procedure of decompressive craniectomy and were monitored with intracranial pressure, brain oxygenation, and temperature. Further, comparison was made with our historical group of patients who had direct brain cooling therapy through the old technique. Results: The results disclosed the direct brain cooling treated patients through a newer technique obtained a better Extended Glasgow Outcome Score than a control group (P < 001). In addition, there is a significant outcome difference between the combined cooling treated patients (new and old technique) with the control group (P < 0.001). Focal brain oxygenation and temperature are likely factors that correlate with better outcomes. Conclusion: Direct brain cooling is feasible, safe, and affects the clinical outcomes of the severely traumatized brain, and physics of thermodynamics may play a role in its pathophysiology.

4.
Micromachines (Basel) ; 14(2)2023 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-36838025

RESUMO

High electron mobility transistor (HEMT) biosensors hold great potential for realizing label-free, real-time, and direct detection. Owing to their unique properties of two-dimensional electron gas (2DEG), HEMT biosensors have the ability to amplify current changes pertinent to potential changes with the introduction of any biomolecules, making them highly surface charge sensitive. This review discusses the recent advances in the use of AlGaN/GaN and AlGaAs/GaAs HEMT as biosensors in the context of different gate architectures. We describe the fundamental mechanisms underlying their operational functions, giving insight into crucial experiments as well as the necessary analysis and validation of data. Surface functionalization and biorecognition integrated into the HEMT gate structures, including self-assembly strategies, are also presented in this review, with relevant and promising applications discussed for ultra-sensitive biosensors. Obstacles and opportunities for possible optimization are also surveyed. Conclusively, future prospects for further development and applications are discussed. This review is instructive for researchers who are new to this field as well as being informative for those who work in related fields.

5.
Lab Chip ; 23(6): 1622-1636, 2023 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-36786757

RESUMO

The emergence of coronavirus disease 2019 (COVID-19) motivates continuous efforts to develop robust and accurate diagnostic tests to detect severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2). Detection of viral nucleic acids provides the highest sensitivity and selectivity for diagnosing early and asymptomatic infection because the human immune system may not be active at this stage. Therefore, this work aims to develop a label-free electrochemical DNA biosensor for SARS-CoV-2 detection using a printed circuit board-based gold substrate (PCBGE). The developed sensor used the nucleocapsid phosphoprotein (N) gene as a biomarker. The DNA sensor-based PCBGE was fabricated by self-assembling a thiolated single-stranded DNA (ssDNA) probe onto an Au surface, which performed as the working electrode (WE). The Au surface was then treated with 6-mercapto-1-hexanol (MCH) before detecting the target N gene to produce a well-oriented arrangement of the immobilized ssDNA chains. The successful fabrication of the biosensor was characterized using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and atomic force microscopy (AFM). The DNA biosensor performances were evaluated using a synthetic SARS-CoV-2 genome and 20 clinical RNA samples from healthy and infected individuals through EIS. The developed DNA biosensor can detect as low as 1 copy per µL of the N gene within 5 minutes with a LOD of 0.50 µM. Interestingly, the proposed DNA sensor could distinguish the expression of SARS-CoV-2 RNA in a patient diagnosed with COVID-19 without any amplification technique. We believe that the proposed DNA sensor platform is a promising point-of-care (POC) device for COVID-19 viral infection since it offers a rapid detection time with a simple design and workflow detection system, as well as an affordable diagnostic assay.


Assuntos
Técnicas Biossensoriais , COVID-19 , Humanos , Ouro/química , SARS-CoV-2/genética , RNA Viral , Técnicas Eletroquímicas , COVID-19/diagnóstico , DNA/química , Eletrodos , DNA de Cadeia Simples
6.
Micromachines (Basel) ; 13(12)2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36557432

RESUMO

The emergence of gallium nitride high-electron-mobility transistor (GaN HEMT) devices has the potential to deliver high power and high frequency with performances surpassing mainstream silicon and other advanced semiconductor field-effect transistor (FET) technologies. Nevertheless, HEMT devices suffer from certain parasitic and reliability concerns that limit their performance. This paper aims to review the latest experimental evidence regarding HEMT technologies on the parasitic issues that affect aluminum gallium nitride (AlGaN)/GaN HEMTs. The first part of this review provides a brief introduction to AlGaN/GaN HEMT technologies, and the second part outlines the challenges often faced during HEMT fabrication, such as normally-on operation, self-heating effects, current collapse, peak electric field distribution, gate leakages, and high ohmic contact resistance. Finally, a number of effective approaches to enhancing the device's performance are addressed.

7.
Sensors (Basel) ; 22(23)2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36502059

RESUMO

Recently, there has been increasing interest in electrochemical printed sensors for a wide range of applications such as biomedical, pharmaceutical, food safety, and environmental fields. A major challenge is to obtain selective, sensitive, and reliable sensing platforms that can meet the stringent performance requirements of these application areas. Two-dimensional (2D) nanomaterials advances have accelerated the performance of electrochemical sensors towards more practical approaches. This review discusses the recent development of electrochemical printed sensors, with emphasis on the integration of non-carbon 2D materials as sensing platforms. A brief introduction to printed electrochemical sensors and electrochemical technique analysis are presented in the first section of this review. Subsequently, sensor surface functionalization and modification techniques including drop-casting, electrodeposition, and printing of functional ink are discussed. In the next section, we review recent insights into novel fabrication methodologies, electrochemical techniques, and sensors' performances of the most used transition metal dichalcogenides materials (such as MoS2, MoSe2, and WS2), MXenes, and hexagonal boron-nitride (hBN). Finally, the challenges that are faced by electrochemical printed sensors are highlighted in the conclusion. This review is not only useful to provide insights for researchers that are currently working in the related area, but also instructive to the ones new to this field.


Assuntos
Técnicas Biossensoriais , Nanoestruturas , Elementos de Transição , Técnicas Eletroquímicas/métodos , Técnicas Biossensoriais/métodos
8.
Sensors (Basel) ; 22(19)2022 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-36236769

RESUMO

Sweat analysis offers non-invasive real-time on-body measurement for wearable sensors. However, there are still gaps in current developed sweat-sensing devices (SSDs) regarding the concerns of mixing fresh and old sweat and real-time measurement, which are the requirements to ensure accurate the measurement of wearable devices. This review paper discusses these limitations by aiding model designs, features, performance, and the device operation for exploring the SSDs used in different sweat collection tools, focusing on continuous and non-continuous flow sweat analysis. In addition, the paper also comprehensively presents various sweat biomarkers that have been explored by earlier works in order to broaden the use of non-invasive sweat samples in healthcare and related applications. This work also discusses the target analyte's response mechanism for different sweat compositions, categories of sweat collection devices, and recent advances in SSDs regarding optimal design, functionality, and performance.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Biomarcadores/análise , Monitorização Fisiológica , Suor/química
9.
Micromachines (Basel) ; 13(9)2022 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-36144136

RESUMO

Face recognition is one of the most sophisticated disciplines of biometric systems. The use of VCSEL in automotive applications is one of the most recent advances. The existing VCSEL package with a diffuser on top of a lens intended for automotive applications could not satisfy the criteria of the automotive TS16949: 2009 specification because the package was harmed and developed a lens fracture during 100 thermal cycle tests. In order to complete a cycle, the temperature rises from -40 °C to 150 °C and then rises again from 150 °C to 260 °C. The package then needs to be tested 500 times to ensure it fits the requirements without failing in terms of appearance or functionality. To this extent, the goal of this research is to develop packaging for 1 mm2 VCSEL chips with a diffuser on top that prevents fractures or damage to the package during heat cycle testing with multiple materials. The package was created using the applications SolidWorks 2017 and AutoCAD Mechanical 2017. The ANSYS Mechanical Structural FEA Analysis program simulated all packages for mechanical stress to guarantee that all packages generated were resilient to high temperature conditions. All packages exhibit no abnormalities and are robust for various temperatures ranging from low to high. Therefore, these packaged 1 mm2 VCSEL chips with a diffuser on top provide an effective approach for the application of VCSEL suitable in high temperature conditions.

10.
Biosensors (Basel) ; 12(7)2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35884276

RESUMO

The development of precise and efficient diagnostic tools enables early treatment and proper isolation of infected individuals, hence limiting the spread of coronavirus disease 2019 (COVID-19). The standard diagnostic tests used by healthcare workers to diagnose severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection have some limitations, including longer detection time, the need for qualified individuals, and the use of sophisticated bench-top equipment, which limit their use for rapid SARS-CoV-2 assessment. Advances in sensor technology have renewed the interest in electrochemical biosensors miniaturization, which provide improved diagnostic qualities such as rapid response, simplicity of operation, portability, and readiness for on-site screening of infection. This review gives a condensed overview of the current electrochemical sensing platform strategies for SARS-CoV-2 detection in clinical samples. The fundamentals of fabricating electrochemical biosensors, such as the chosen electrode materials, electrochemical transducing techniques, and sensitive biorecognition molecules, are thoroughly discussed in this paper. Furthermore, we summarised electrochemical biosensors detection strategies and their analytical performance on diverse clinical samples, including saliva, blood, and nasopharyngeal swab. Finally, we address the employment of miniaturized electrochemical biosensors integrated with microfluidic technology in viral electrochemical biosensors, emphasizing its potential for on-site diagnostics applications.


Assuntos
Técnicas Biossensoriais , COVID-19 , Técnicas Biossensoriais/métodos , COVID-19/diagnóstico , Teste para COVID-19 , Técnicas Eletroquímicas , Humanos , SARS-CoV-2
11.
Pathogens ; 10(9)2021 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-34578216

RESUMO

Typhoid fever, also known as typhoid, is a life-threatening bacterial infection that remains a global health concern. The infection is associated with a significant morbidity and mortality rate, resulting in an urgent need for specific and rapid detection tests to aid prevention and management of the disease. The present review aims to assess the specificity and sensitivity of the available literature on the immunodiagnostics of typhoid fever. A literature search was conducted using three databases (PubMed, ProQuest and Scopus) and manual searches through the references of identified full texts to retrieve relevant literature published between 1 January 2011 and 31 December 2020. Of the 577 studies identified in our search, 12 were included in further analysis. Lipopolysaccharides (LPS) and hemolysin E (HlyE) were the most frequently studied antigens. The specimens examined in these studies included serum and saliva. Using blood culture as the gold standard, anti-LPS IgA gave the highest sensitivity of 96% (95% CI: 93-99) and specificity of 96% (95% CI: 93-99) for distinguishing between typhoid cases and healthy controls, whereas the combination of anti-LPS and anti-flagellin total IgGAM gave the highest sensitivity of 93% (95% CI: 86-99) and specificity of 95% (95% CI: 89-100) for distinguishing typhoid cases and other febrile infections. A comparably high sensitivity of 92% (95% CI: 86-98) and specificity of 89% (95% CI: 78-100) were shown in testing based on detection of the combination of anti-LPS (IgA and IgM) and anti-HlyE IgG as well as a slightly lower sensitivity of 91% (95% CI: 74-100) in the case of anti-50kDa IgA. Anti-50kDa IgM had the lowest sensitivity of 36% (95% CI: 6-65) against both healthy and febrile controls. The development of a rapid diagnostic test targeting antibodies against lipopolysaccharides combined with flagellin appeared to be a suitable approach for the rapid detection test of typhoid fever. Saliva is added benefit for rapid typhoid diagnosis since it is less invasive. As a result, further studies could be done to develop additional approaches for adopting such samples.

12.
Sensors (Basel) ; 21(16)2021 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-34451023

RESUMO

In acoustic receiver design, the receiving sensitivity and bandwidth are two primary parameters that determine the performance of a device. The trade-off between sensitivity and bandwidth makes the design very challenging, meaning it needs to be fine-tuned to suit specific applications. The ability to design a PMUT with high receiving sensitivity and a wide bandwidth is crucial to allow a wide spectrum of transmitted frequencies to be efficiently received. This paper presents a novel structure involving a double flexural membrane with a fluidic backing layer based on an in-plane polarization mode to optimize both the receiving sensitivity and frequency bandwidth for medium-range underwater acoustic applications. In this structure, the membrane material and electrode configuration are optimized to produce good receiving sensitivity. Simultaneously, a fluidic backing layer is introduced into the double flexural membrane to increase the bandwidth. Several piezoelectric membrane materials and various electrode dimensions were simulated using finite element analysis (FEA) techniques to study the receiving performance of the proposed structure. The final structure was then fabricated based on the findings from the simulation work. The pulse-echo experimental method was used to characterize and verify the performance of the proposed device. The proposed structure was found to have an improved bandwidth of 56.6% with a receiving sensitivity of -1.8864 dB rel 1 V µPa. For the proposed device, the resonance frequency and center frequency were 600 and 662.5 kHz, respectively, indicating its suitability for the targeted frequency range.


Assuntos
Transdutores , Ultrassom , Acústica , Eletrodos , Desenho de Equipamento
13.
Biosensors (Basel) ; 10(10)2020 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-33081162

RESUMO

Non-structural protein 1 (NS1 protein) is becoming a commonplace biomarker for the diagnostic of early detection of dengue. In this study, we sought to use a label-free approach of detecting NS1 protein by harnessing fluidic-based memristor sensor. The sensor was fabricated using sol-gel spin coating technique, by which TiO2 thin film is coated on the surface of Indium tin oxide (ITO) and a glass substrate. The sensor was then functionalized with glycidoxypropyl-trimethoxysilane (GPTS), acting as antibody for NS1. The addition of the target NS1 formed an antibody-antigen complex which altered the physical and electrical properties in sensing region. Sensing of the sensor is incumbent upon the measurement of Off-On resistance ratio. Imaging with Field Emission Scanning Electron Microscope (FESEM) evinced the successful immobilization of the antibody and the subsequent capture of the NS1 protein by the immobilized antibody. The detection limit actualized by the developed sensor was 52 nM and the diameter of 2 mm gives the most optimal measurement. The developed sensor demonstrated an immense potential towards the development of label-free diagnostic of early dengue infection.


Assuntos
Técnicas Biossensoriais/métodos , Proteínas , Silanos , Compostos de Estanho
14.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 2977-2980, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30441023

RESUMO

A 3.3 V CMOS bandgap reference (BGR) was presented in this study that utilizes MOS transistors operating in the sub-threshold region. The complexity of the circuit and the dependency of the voltage reference on power supply variations are simultaneously decreased through the use of a new compensation circuit technique. The proposed BGR is simulated using a 0.35 $\mu \mathrm{m}$ CMOS standard process. Consequently, a 5.53 ppm/°C temperature coefficient is obtained in the -40~+125 °C temperature range, the maximum power supply rejection ratio is - 62 dB, and a 2.033 mV/V voltage line regulation is achieved for the $2.3\sim 4.3$ V supply voltage. The proposed circuit dissipates a supply current of 8.89 IJA at a 3.3 V supply voltage, and the active area is 112 $\mu \mathrm{m}\times 60 \mu \mathrm{m}$.


Assuntos
Próteses Visuais , Fontes de Energia Elétrica , Desenho de Equipamento , Telemetria
15.
Nanoscale Res Lett ; 9(1): 604, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25404874

RESUMO

Combination of high-mean free path and scaling ability makes graphene nanoribbon (GNR) attractive for application of field-effect transistors and subject of intense research. Here, we study its behaviour at high bias near and after electrical breakdown. Theoretical modelling, Monte Carlo simulation, and experimental approaches are used to calculate net generation rate, ionization coefficient, current, and finally breakdown voltage (BV). It is seen that a typical GNR field-effect transistor's (GNRFET) breakdown voltage is in the range of 0.5 to 3 V for different channel lengths, and compared with silicon similar counterparts, it is less. Furthermore, the likely mechanism of breakdown is studied.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...