Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Micromachines (Basel) ; 12(8)2021 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-34442581

RESUMO

Detection sensitivity of cassette PCR was compared with a commercial BAX® PCR system for detection of eae and stx genes in Escherichia coli from 806 beef carcass swabs. Cassette PCR detects multiple genetic markers on multiple samples using PCR and melt curve analysis. Conventional PCR served as a gold standard. Overall, for positive and negative concordance, cassette PCR was 98.6% concordant with conventional PCR, and BAX PCR was 65.4% concordant. Of 806 beef carcass swabs, 339 by cassette PCR and 84 by BAX PCR harbored eae + stx+E. coli. For BAX PCR reactions, 84% of eae+ swabs, 79% of stx+ swabs, and 86% of eae + stx+ swabs were also detected by cassette PCR. For cassette PCR reactions, 457 swabs were eae+ with only 117 scored as eae+ using BAX PCR for 26% positive concordance. For stx primers, cassette PCR scored 480 samples as stx+ but only 215 samples were stx+ by BAX PCR, giving 45% positive concordance. Importantly, cassette PCR scored 339 swabs as harboring eae + stx+ E. coli, but BAX PCR detected only 71 positives giving only 21% positive concordance, with many false negatives. Cassette PCR is a highly sensitive method for detection of STEC genes in E. coli found in carcass swabs.

2.
BMC Microbiol ; 19(1): 175, 2019 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-31362696

RESUMO

BACKGROUND: Over a one year period, swabs of 820 beef carcasses were tested for the presence of Shiga toxin-producing Escherichia coli by performing Polymerase Chain Reaction (PCR) in a novel technology termed "cassette PCR", in comparison to conventional liquid PCR. Cassette PCR is inexpensive and ready-to-use. The operator need only add the sample and press "go". Cassette PCR can simultaneously test multiple samples for multiple targets. Carcass swab samples were first tested for the presence of STEC genes (O157, eae, stx1 and stx2). Samples were considered to be pathogenic if positive for eae plus stx1 and/or stx2. For samples scored as pathogenic, further testing screened for 6 additional high frequency O-antigens (O26, O45, O103, O111, O121, and O145). RESULTS: Of the 820 samples, 41% were pathogenic and 30% were O157 positive. Of these, 19% of samples were positive for O157 and carried potentially pathogenic E. coli (eae plus stx1 and/or stx2). Of all samples identified as carrying pathogenic E. coli, 18.9, 38.8, 41.4, 0, 36.1, and 4.1% respectively were positive for O26, O45, O103, O111, O121, and O145. To validate cassette PCR testing, conventional PCR using STEC primers was performed on each of the 820 samples. Only 148 of 3280 cassette PCR tests were discordant with conventional PCR results. However, further fractional testing showed that 110 of these 148 PCRs reflected low numbers of E. coli in the enrichment broth and could be explained as due to Poisson limiting dilution of the template, affecting both cassette PCR and conventional PCR. Of the remaining 38 discordant tests, 27 initial capillary PCRs and 10 initial conventional tests were nominally discordant between cassette and conventional PCR, perhaps reflecting human/technical error on both sides of the comparison. CONCLUSIONS: Contaminated beef carcass swabs were often complex, likely harboring more than one strain of pathogenic E. coli. Cassette PCR had 98.8% concordance with parallel conventional PCR for detection of STEC genes. This indicates that cassette PCR is highly reliable for detecting multiple pathogens in beef carcass swabs from processing plants.


Assuntos
Proteínas de Escherichia coli/genética , Reação em Cadeia da Polimerase Multiplex , Carne Vermelha/microbiologia , Escherichia coli Shiga Toxigênica/isolamento & purificação , Adesinas Bacterianas/genética , Animais , Bovinos , Infecções por Escherichia coli , Microbiologia de Alimentos/métodos , Genes Bacterianos , Antígenos O/genética , Carne Vermelha/toxicidade , Toxina Shiga I/genética , Toxina Shiga II/genética , Escherichia coli Shiga Toxigênica/genética
3.
BMC Microbiol ; 19(1): 93, 2019 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-31088365

RESUMO

BACKGROUND: Fast molecular detection methods benefit from ready-to-run lab-on-a-chip molecular assays with minimum preparation time. Detection efficiency of such methods can improve if multiple targets are detected simultaneously per given reaction. Detection of food pathogens, i.e. Escherichia coli (E. coli), is generally performed in two stages with the detection of multiple targets in each stage.With simultaneous testing, screening for pathogens is fast and efficient. RESULTS: In this study, we show the application of multiplex PCR performed on a ready-made cassette to detect 10 targets each for eight samples known to harbor E. coli. In cassette PCR, the aluminum cassette (38.6 mm × 31.4 mm) contains 10 trenches having a total of 50 capillaries with microliter volumes of desiccated acrylamide gels holding all reagents required for the PCR including internal positive and negative controls. The gel contains LCGreen dye to detect double stranded DNA. Fluorescence monitoring allows the detection of the amplified products by melt curve analysis. In this application, each of the five capillaries in a given trench contains two of the primer sets for the detection of 10 targets in pathogenic E. coli, namely, O157, Eae, Stx1, Stx2 and six O-antigen genes. Primer specificity was confirmed. Each trench tests one sample. Eight minimally processed enriched beef carcass swab samples were analyzed for parallel detection of 10 targets within 1 h and 15 min. Samples were delivered to the capillaries by capillary forces thereby hydrating the gels. Multiplex cassette PCR results were confirmed with conventional multiplex PCRs performed in a commercial real-time PCR system. CONCLUSIONS: Cassette PCR technology is ideally suited to multi-target detection of pathogens in food products. The cassette performs multiple PCR reactions in parallel, with multiplex detection of targets within each reaction unit. Cassette PCR/ melt curve analysis results for the simultaneous detection of 10 targets of pathogenic E.coli in beef carcass swab samples were confirmed with a conventional real-time PCR/ melt curve analysis as well as with agarose gel electrophoresis. Although designed for the detection of E. coli, this multiplex cassette PCR technique can be applied to any other assay where the fast detection of multiple targets is required.


Assuntos
Escherichia coli Êntero-Hemorrágica/isolamento & purificação , Contaminação de Alimentos , Microbiologia de Alimentos/métodos , Dispositivos Lab-On-A-Chip , Reação em Cadeia da Polimerase Multiplex/instrumentação , Animais , Bovinos , DNA Bacteriano/genética , Escherichia coli Êntero-Hemorrágica/genética , Genes Bacterianos , Carne Vermelha/microbiologia
4.
PLoS One ; 13(5): e0197100, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29746561

RESUMO

In this manuscript, we report the design and development of a fast, reliable instrument to run gel-based cassette polymerase chain reactions (PCR). Here termed the GelCycler Mark II, our instrument is a miniaturized molecular testing system that is fast, low cost and sensitive. Cassette PCR utilizes capillary reaction units that carry all reagents needed for PCR, including primers and Taq polymerase, except the sample, which is loaded at the time of testing. Cassette PCR carries out real time quantitative PCR followed by melt curve analysis (MCA) to verify amplicon identity at the expected melt temperature (Tm). The cassette PCR technology is well developed, particularly for detecting pathogens, and has been rigorously validated for detecting pathogenic Escherichia coli in meat samples. However, the work has been hindered by the lack of a robust and stable instrument to carry out the PCR, which requires fast and accurate temperature regulation, improved light delivery and fluorescent recording, and faster PCR reactions that maintain a high sensitivity of detection. Here, we report design and testing of a new instrument to address these shortcomings and to enable standardized testing by cassette PCR and commercial manufacture of a robust and accurate instrument that can be mass produced to deliver consistent performance. As a corollary to our new instrument development, we also report the use of an improved design approach using a machined aluminum cassette to meet the new instrument standards, prevent any light bleed across different trenches in each cassette, and allow testing of a larger number of samples for more targets in a single run. The GelCycler Mark II can detect and report E. coli contamination in 41 minutes. Sample positives are defined in as having a melt curve comparable to the internal positive control, with peak height exceeding that of the internal negative control. In a fractional analysis, as little as 1 bacterium per capillary reaction unit is directly detectable, with no enrichment step, in 35 cycles of PCR/MCA, in a total time of 53 minutes, making this instrument and technology among the very best for speed and sensitivity in screening food for pathogenic contamination.


Assuntos
Escherichia coli , Análise de Alimentos/métodos , Microbiologia de Alimentos/métodos , Carne/microbiologia , Reação em Cadeia da Polimerase/métodos , Humanos
5.
Methods Mol Biol ; 1310: 175-91, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26024635

RESUMO

With the smaller size, low cost, and rapid testing capabilities, miniaturized lab-on-a-chip devices can change the way medical diagnostics are currently performed in the health-care system. We have demonstrated such a device that is self-contained, simple, disposable, and inexpensive. It is capable of performing DNA amplification on an inexpensive instrument suitable for near point of care settings. This technology will enable on the spot evaluation of patients in the clinic for faster medical decision-making and more informed therapeutic choices. Our device, a gel capillary cassette, termed cassette PCR, contains capillary reaction units each holding a defined primer set, with arrays of capillary reaction units for simultaneously detecting multiple targets. With the exception of the sample to be tested, each capillary reaction unit holds all the reagents needed for PCR in a desiccated form that can be stored at room temperature for up to 3 months and even longer in colder conditions. It relies on capillary forces for sample delivery of microliter volumes through capillaries, hence avoiding the need for pumps or valves. In the assembled cassette, the wax architecture supporting the capillaries melts during the PCR and acts as a vapor barrier as well as segregating capillaries with different primer sets. No other chip sealing techniques are required. Cassette PCR accepts raw samples such as urine, genital swabs, and blood. The cassette is made with off-the-shelf components and contains integrated positive and negative controls.


Assuntos
Impressões Digitais de DNA/instrumentação , DNA/genética , Dispositivos Lab-On-A-Chip , Reação em Cadeia da Polimerase/instrumentação , Impressões Digitais de DNA/economia , Impressões Digitais de DNA/métodos , Primers do DNA/genética , Desenho de Equipamento , Humanos , Dispositivos Lab-On-A-Chip/economia , Miniaturização/instrumentação , Miniaturização/métodos , Reação em Cadeia da Polimerase/economia , Reação em Cadeia da Polimerase/métodos
6.
J Mol Diagn ; 16(5): 550-557, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24998937

RESUMO

Point-of-care devices can lower costs through reduced reagent costs, shifting diagnostics from centralized laboratories to local clinics or hospitals, rapidly informing on the spot medical decision making, and enabling personalized treatment options. We have previously described a self-contained miniaturized device that uses an array of gel-based reaction units that can simultaneously detect multiple biomarkers and/or multiple patients in one PCR cassette and can be stored for up to 7 months. In this article, we document the ability of cassette PCR to detect single nucleotide polymorphisms (SNPs) in human genomic DNA from buccal swabs. Swab processing takes 8 minutes, and PCR is completed in just more than an hour. To demonstrate potential for genotyping, we used allele-specific PCR and melt curve analysis to detect major and minor alleles of two SNPs in the fibroblast growth factor receptor 2 gene (FGFR2) that are linked with breast cancer. After allele-specific PCR, seamless melt curve analysis and the presence or absence of melt peaks from melt curve analysis identifies the FGFR2 SNP genotypes for each patient. The near point-of-care/point-of-need genotyping methods reported here can be applied for detecting and assessing risks of diseases such as cancer and to detect SNPs that alter drug metabolism and hence response to therapy.


Assuntos
DNA , Genoma Humano , Técnicas de Genotipagem , Reação em Cadeia da Polimerase/métodos , Polimorfismo de Nucleotídeo Único , Alelos , Frequência do Gene , Testes Genéticos/métodos , Genótipo , Humanos , Mucosa Bucal/citologia , Receptor Tipo 2 de Fator de Crescimento de Fibroblastos/genética
7.
Malar J ; 13: 179, 2014 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-24885206

RESUMO

BACKGROUND: Access to timely and accurate diagnostic tests has a significant impact in the management of diseases of global concern such as malaria. While molecular diagnostics satisfy this need effectively in developed countries, barriers in technology, reagent storage, cost and expertise have hampered the introduction of these methods in developing countries. In this study a simple, lab-on-chip PCR diagnostic was created for malaria that overcomes these challenges. METHODS: The platform consists of a disposable plastic chip and a low-cost, portable, real-time PCR machine. The chip contains a desiccated hydrogel with reagents needed for Plasmodium specific PCR. Chips can be stored at room temperature and used on demand by rehydrating the gel with unprocessed blood, avoiding the need for sample preparation. These chips were run on a custom-built instrument containing a Peltier element for thermal cycling and a laser/camera setup for amplicon detection. RESULTS: This diagnostic was capable of detecting all Plasmodium species with a limit of detection for Plasmodium falciparum of 2 parasites/µL of blood. This exceeds the sensitivity of microscopy, the current standard for diagnosis in the field, by ten to fifty-fold. In a blind panel of 188 patient samples from a hyper-endemic region of malaria transmission in Uganda, the diagnostic had high sensitivity (97.4%) and specificity (93.8%) versus conventional real-time PCR. The test also distinguished the two most prevalent malaria species in mixed infections, P. falciparum and Plasmodium vivax. A second blind panel of 38 patient samples was tested on a streamlined instrument with LED-based excitation, achieving a sensitivity of 96.7% and a specificity of 100%. CONCLUSIONS: These results describe the development of a lab-on-chip PCR diagnostic from initial concept to ready-for-manufacture design. This platform will be useful in front-line malaria diagnosis, elimination programmes, and clinical trials. Furthermore, test chips can be adapted to detect other pathogens for a differential diagnosis in the field. The flexibility, reliability, and robustness of this technology hold much promise for its use as a novel molecular diagnostic platform in developing countries.


Assuntos
Dispositivos Lab-On-A-Chip , Malária/diagnóstico , Técnicas de Diagnóstico Molecular/instrumentação , Técnicas de Diagnóstico Molecular/métodos , Plasmodium/isolamento & purificação , Reação em Cadeia da Polimerase/instrumentação , Reação em Cadeia da Polimerase/métodos , Adolescente , Adulto , Feminino , Humanos , Malária/parasitologia , Plasmodium/classificação , Gravidez , Sensibilidade e Especificidade , Uganda , Adulto Jovem
8.
Lab Chip ; 13(20): 4087-95, 2013 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-23966212

RESUMO

For effective clinical uptake of the lab on a chip/point of care technology (LOC-POC), in addition to cost advantages LOC-POC devices should offer multiple patient screening panels for related diseases as well as cold-chain transportation and storage abilities. We recently described a device that performs polymerase chain reaction (PCR) to simultaneously screen raw clinical samples from up to 16 patients for multiple infectious agents (Manage et al., Lab Chip, 2013, 13, 2576-2584). This cassette contains glass capillaries with desiccated semi-solid acrylamide gels that include all the reagents except for the sample, with integrated quality control. Here we report the development of protocols to store assembled PCR cassettes at room temperature, 4 °C or -20 °C as well as at +40 °C. We show that our cassettes are stable, with no loss of activity for at least 3 months at RT and at least 7 months at 4 °C and -20 °C. However, the activity of desiccated cassettes degrades when stored for more than 2 weeks at 40 °C, insufficient time for post-manufacture delivery and use of cassette PCR. To address this, we have evaluated two stage storage protocols. PCR cassettes can initially be stored at 4 °C and -20 °C for prolonged periods of time and removed for shorter term storage at RT, retaining activity for at least a month, which would facilitate transport to remote areas for testing. Effective use of cassette PCR in high temperature regions of the world, for experimental purposes defined here as 40 °C, appears to be feasible only after a first stage storage in the cold, followed by no more than 1 week at 40 °C. This should allow sufficient time for delivery by the manufacturer to a central area well served by power and refrigeration, for later ambient temperature transport and use in under-resourced areas that lack refrigeration.


Assuntos
Acrilamidas/química , Sistemas Automatizados de Assistência Junto ao Leito , Reação em Cadeia da Polimerase/instrumentação , Géis , Vidro/química , Herpesvirus Humano 1/genética , Herpesvirus Humano 1/isolamento & purificação , Herpesvirus Humano 2/genética , Herpesvirus Humano 2/isolamento & purificação , Humanos , Temperatura , Fatores de Tempo
9.
Lab Chip ; 13(20): 4011-4, 2013 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-23966268

RESUMO

Testing of whole blood in miniaturized PCR is compromised by the opaque nature of whole blood that leads to physical masking of a fluorescent signal. We demonstrate a method to perform real-time PCR with whole blood that avoids interference from the opacity of whole blood.


Assuntos
Sangue/metabolismo , Técnicas de Diagnóstico Molecular/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Reação em Cadeia da Polimerase/métodos , Fitas Reagentes/química , Artefatos , Análise Química do Sangue , Géis , Humanos , Reação em Cadeia da Polimerase em Tempo Real
10.
Lab Chip ; 13(13): 2576-84, 2013 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-23471315

RESUMO

This work describes a self-contained, simple, disposable, and inexpensive gel capillary cassette for DNA amplification in near point of care settings. The cassette avoids the need for pumps or valves during raw sample delivery or polymerase chain reaction (PCR) amplification steps. The cassette contains capillary reaction units that can be stored at room temperature for up to 3 months. The current cassette configuration format simultaneously tests up to 16 patients for two or more targets, accommodates different sample types on the same cassette, has integrated positive and negative controls and allows flexibility for multiple geometries. PCR reagents in the cassette are desiccated to allow storage at room temperature with rehydration by raw sample at the time of testing. The sample is introduced to the cassette via a transfer pipette simply by capillary force. DNA amplification was carried out in a portable prototype instrument for PCR thermal cycling with fluorescence detection of amplified products by melt curve analysis (MCA). To demonstrate performance, raw genital swabs and urine were introduced to the same cassette to simultaneously detect four sexually transmitted infections. Herpes Simplex Viruses (HSV-1 and HSV-2) were detected from raw genital swabs. Ureaplasma urealyticum (UU) and Mycoplasma homonis (MH) were detected from raw urine. Results for multiple patients were obtained in as little as 50 min. This platform allows multiparameter clinical testing with a pre-assembled cassette that requires only the introduction of raw sample. Modification of the prototype device to accommodate larger cassettes will ultimately provide high throughput simultaneous testing of even larger numbers of samples for many different targets, as is required for some clinical applications. Combinations of wax and/or polymer cassettes holding capillary reaction units are feasible. The components of the cassette are suited to mass production and robotic assembly to produce a readily manufactured disposable reaction cassette that can be configured for disease-specific testing panels. Rapid testing with a disposable reaction cassette on an inexpensive instrument will enable on the spot evaluation of patients in the clinic for faster medical decision-making and more informed therapeutic choices.


Assuntos
DNA Bacteriano/urina , DNA Viral/análise , Reação em Cadeia da Polimerase/métodos , Feminino , Géis/química , Herpesvirus Humano 1/genética , Herpesvirus Humano 2/genética , Humanos , Mycoplasma hominis/genética , Reação em Cadeia da Polimerase/instrumentação , Temperatura , Ureaplasma urealyticum/genética , Vagina/virologia
11.
Electrophoresis ; 33(21): 3213-21, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23027089

RESUMO

Electrophoresis is a powerful method that has seen a wide range of applications, often in automated genetic diagnostic instruments that require the use of a replaceable sieving matrix. The power and simplicity of electrophoresis as an analysis technique would be ideal for highly integrated and low-cost analysis systems if the method could be implemented in microfluidics on the scale of several mm. We demonstrate the electrophoretic analysis of DNA with separation lengths as small as 2 mm and with a resolution adequate for the analysis of PCR products, i.e. resolutions of 10-20 base pairs. Such small-scale separations enable analysis systems consisting of microfluidics and microelectronics integrated into a single inexpensive package, thereby overcoming a key challenge facing the development of the lab on chip technologies.


Assuntos
Resinas Acrílicas/química , DNA/isolamento & purificação , Eletroforese em Microchip/instrumentação , Eletroforese em Microchip/métodos , DNA/química , Peso Molecular , Semicondutores
12.
Lab Chip ; 12(9): 1664-71, 2012 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-22426784

RESUMO

Herpes simplex virus (HSV) is one of the most prevalent viruses, with acute and recurrent infections in humans. The current gold standard for the diagnosis of HSV is viral culture which takes 2-14 days and has low sensitivity. In contrast, DNA amplification by polymerase chain reaction (PCR) can be performed within 1-2 h. We here describe a multiparameter PCR assay to simultaneously detect HSV-1 and HSV-2 DNA templates, together with integrated positive and negative controls, with product detection by melting curve analysis (MCA), in an array of semi-solid polyacrylamide gel posts. Each gel post is 0.67 µL in volume, and polymerized with all the components required for PCR. Both PCR and MCA can currently be performed in one hour and 20 min. Unprocessed genital swabs collected in universal transport medium were directly added to the reagents before or after polymerization, diffusing from atop the gel posts. The gel post platform detects HSV templates in as little as 2.5 nL of raw sample. In this study, 45 genital swab specimens were tested blindly as a preliminary validation of this platform. The concordance of PCR on gel posts with conventional PCR was 91%. The primer sequestration method introduced here (wherein different primers are placed in different sets of posts) enables the simultaneous detection of multiple pathogens for the same sample, together with positive and negative controls, on a single chip. This platform accepts unprocessed samples and is readily adaptable to detection of multiple different pathogens or biomarkers for point-of-care diagnostics.


Assuntos
DNA Viral/análise , Genitália/virologia , Herpesvirus Humano 1/isolamento & purificação , Herpesvirus Humano 2/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Primers do DNA , Desenho de Equipamento , Herpes Genital/diagnóstico , Herpes Genital/virologia , Herpesvirus Humano 1/genética , Herpesvirus Humano 2/genética , Humanos , Limite de Detecção , Desnaturação de Ácido Nucleico , Reação em Cadeia da Polimerase/instrumentação , Projetos de Pesquisa , Espectrometria de Fluorescência , Temperatura
13.
Anal Chem ; 82(19): 8079-87, 2010 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-20809605

RESUMO

This work describes the use of polyacrylamide gel and PCR reagents photopolymerized in a mold to create an array of semisolid posts that serve as reaction vessels for parallel PCR amplification of an externally added template. DNA amplification occurred in a cylindrical, self-standing 9 × 9 array of gel posts each less than 1 µL in volume. Photopolymerization of the gel with an intercalating dye added prior to polymerization permitted acquisition of real-time PCR data and melting curve analysis data without the need for any type of post-PCR staining procedures. PCR was equally efficient and reproducible when template DNA was polymerized within the gel or when exogenous template was added atop precast gel posts. PCR amplification occurred with template from purified DNA or from raw urine of patients with BK viruria. Multiple primer sets can be utilized per gel post array with no detectable cross contamination. As few as 34 BK virus templates were consistently detected by PCR in an individual gel post. Amplification of HPA1 and FGFR2 genes in human genomic DNA (gDNA) required as little as 2-5 ng of gDNA template/gel post. The device prototype includes a Peltier element for PCR thermal cycling and a CCD camera to capture fluorescence for product detection. Our technology is amenable to integration in point of care microdevices.


Assuntos
Vírus BK/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Resinas Acrílicas/química , Antígenos de Plaquetas Humanas/genética , Vírus BK/genética , DNA Viral/urina , Genótipo , Humanos , Integrina beta3 , Desnaturação de Ácido Nucleico , Transição de Fase , Receptor Tipo 2 de Fator de Crescimento de Fibroblastos/genética
14.
J Clin Microbiol ; 48(9): 3081-7, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20631115

RESUMO

Mutations within the Plasmodium falciparum dihydrofolate reductase gene (Pfdhfr) contribute to resistance to antimalarials such as sulfadoxine-pyrimethamine (SP). Of particular importance are the single nucleotide polymorphisms (SNPs) within codons 51, 59, 108, and 164 in the Pfdhfr gene that are associated with SP treatment failure. Given that traditional genotyping methods are time-consuming and laborious, we developed an assay that provides the rapid, high-throughput analysis of parasite DNA isolated from clinical samples. This assay is based on asymmetric real-time PCR and melt-curve analysis (MCA) performed on the LightCycler platform. Unlabeled probes specific to each SNP are included in the reaction mixture and hybridize differentially to the mutant and wild-type sequences within the amplicon, generating distinct melting curves. Since the probe is present throughout PCR and MCA, the assay proceeds seamlessly with no further addition of reagents. This assay was validated for analytical sensitivity and specificity using plasmids, purified genomic DNA from reference strains, and parasite cultures. For all four SNPs, correct genotypes were identified with 100 copies of the template. The performance of the assay was evaluated with a blind panel of clinical isolates from travelers with low-level parasitemia. The concordance between our assay and DNA sequencing ranged from 84 to 100% depending on the SNP. We also directly compared our MCA assay to a published TaqMan real-time PCR assay and identified major issues with the specificity of the TaqMan probes. Our assay provides a number of technical improvements that facilitate the high-throughput screening of patient samples to identify SP-resistant malaria.


Assuntos
Ensaios de Triagem em Larga Escala/métodos , Plasmodium falciparum/genética , Reação em Cadeia da Polimerase/métodos , Polimorfismo de Nucleotídeo Único , Proteínas de Protozoários/genética , Tetra-Hidrofolato Desidrogenase/genética , DNA de Protozoário/genética , DNA de Protozoário/isolamento & purificação , Resistência a Medicamentos , Genótipo , Humanos , Malária Falciparum/parasitologia , Testes de Sensibilidade Parasitária/métodos , Plasmodium falciparum/classificação , Sensibilidade e Especificidade , Temperatura de Transição
15.
Electrophoresis ; 29(12): 2466-76, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18512674

RESUMO

In this work, microfluidic chips were used to study the electrophoresis of supercoiled DNA (SC DNA) in agarose. This system allowed us to study the electrophoretic and trapping behaviours of SC DNA of various lengths, at various fields and separation distances. Near a critical electric field the DNA is trapped such that the concentration falls exponentially with distance. The trapping of such circular DNA has been explained in terms of the 'lobster trap' or 'impalement' model where shorter fibres become trapping sites at higher fields, leading to an ongoing (and gradual) increase in trapping with increasing field. By contrast, the present study suggests that under some circumstances the traps have a barrier such that only when the DNA has sufficient energy (at high enough fields) can it become trapped, leading to a sudden transition in behaviours at the critical field. We propose an 'activated impalement' mechanism of trapping in which only at sufficiently high fields is the SC DNA impaled and trapped for long times. The critical electric field appears to be inversely proportional to the length of the DNA molecule, suggesting that the force required to impale the SC DNA is constant.


Assuntos
DNA Super-Helicoidal/análise , Eletroforese em Gel de Ágar , Eletroforese em Microchip
16.
J Chromatogr B Analyt Technol Biomed Life Sci ; 822(1-2): 78-84, 2005 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-15990373

RESUMO

Abnormalities in mitochondrial function play a major role in many human diseases. It is often of critical importance to ascertain what proportion of the mitochondria within a cell, or cells, bear a given mutation (the mitochondrial "demographics"). In this work, a rapid, novel, on-chip procedure was used, in which a restriction enzyme was employed to excise a mitochondrial DNA (mtDNA) sequence from plasmid DNA that acted as a prototypical mitochondrial genome. The DNA was then denatured, reassembled to form duplexes, fluorescently labelled and analysed. This method was able to differentiate between a homogeneous population and a heterogeneous population. Using a microfluidic chip, the method could be performed in about 45 min, even without robotics or multiplexed operation, whereas conventional methods of analysis require days to perform. This method may ultimately form the basis for a means of characterizing the mitochondrial demographics of a single cell.


Assuntos
DNA Mitocondrial/análise , Técnicas Analíticas Microfluídicas/métodos , Desoxirribonuclease EcoRI/metabolismo , Eletroforese/métodos , Escherichia coli/metabolismo , Vetores Genéticos , Humanos , Plasmídeos/genética
17.
J Nanobiotechnology ; 3(1): 2, 2005 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-15717935

RESUMO

BACKGROUND: DNA self-assembly methods have played a major role in enabling methods for acquiring genetic information without having to resort to sequencing, a relatively slow and costly procedure. However, even self-assembly processes tend to be very slow when they rely upon diffusion on a large scale. Miniaturisation and integration therefore hold the promise of greatly increasing this speed of operation. RESULTS: We have developed a rapid method for implementing the self-assembly of DNA within a microfluidic system by electrically extracting the DNA from an environment containing an uncharged denaturant. By controlling the parameters of the electrophoretic extraction and subsequent analysis of the DNA we are able to control when the hybridisation occurs as well as the degree of hybridisation. By avoiding off-chip processing or long thermal treatments we are able to perform this hybridisation rapidly and can perform hybridisation, sizing, heteroduplex analysis and single-stranded conformation analysis within a matter of minutes. The rapidity of this analysis allows the sampling of transient effects that may improve the sensitivity of mutation detection. CONCLUSIONS: We believe that this method will aid the integration of self-assembly methods upon microfluidic chips. The speed of this analysis also appears to provide information upon the dynamics of the self-assembly process.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...