Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Radiother Oncol ; : 110335, 2024 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-38772477

RESUMO

BACKGROUND: Oligometastases in mediastinal nodes are increasingly prevalent, posing challenges for treatment with stereotactic body radiotherapy (SBRT) due to proximity to organs at risk (OARs). We report the results of a single prospective observational phase II trial on ablative SBRT for medically inoperable thoracic nodes metastases (NCT02970955). MATERIAL AND METHODS: Since 2017, patients with < 3 nodal metastases were evaluated by the tumor board and included if deemed inoperable. SBRT was delivered using risk adaptive approach based on number, site and size of metastatic nodes (50 Gy/5fractions, 60 Gy/8fractions, 70 Gy/10 fractions). Planning target volume (PTV) partial underdosage was allowed. The primary end point was local control (LC) at 12 months. Secondary end points were: acute and late toxicities, overall survival (OS), progression free survival (PFS), and time to next systemic therapy (TTNS). RESULTS: Between 03/2017-11/2021, 32 patients (41 nodal metastases) were included. NSCLC (13pts), breast (5pts) and colorectal cancer (4pts) were the most represented primary tumour. In 66 % cases, partial PTV undercoverage was necessary. LC at 1 and 2 years was 93.5 % and 82.3 %, respectively. Treatment was well-tolerated with no acute or late toxicity ≥ G3. Median OS was 59.7 months. OS at 1 and 2 years was 96.9 % and 83.8 % respectively. Median PFS was 12.2 months. PFS at 1 and 2 years was 53.1 % and 31.3 %, respectively. CONCLUSION: This trial supported the feasibility and safety of ablative SBRT for thoracic nodes metastases thanks to risk adaptive approach allowing to delay of new systemic therapies. Larger studies are needed to confirm these observations.

2.
Radiother Oncol ; 195: 110240, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38522597

RESUMO

BACKGROUND AND PURPOSE: To report mature results for local control and survival in oligometastatic (OM) breast cancer patients treated with stereotactic body radiotherapy (SBRT) on lung and/or liver lesions in a phase II trial. METHODS: This is a prospective non-randomized phase II trial (NCT02581670) which enrolled patients from 2015 to 2021. Eligibility criteria included: age > 18 years, ECOG 0-2, diagnosis of breast cancer, maximum of 4 lung/liver lesions (with a maximum diameter < 5 cm), metastatic disease confined to the lungs and liver or extrapulmonary or extrahepatic disease stable or responding to systemic therapy. The primary end-points were local control (LC) and treatment-related toxicities. The secondary end-points included overall survival (OS), distant metastasis-free survival (DMFS), time to next systemic therapy (TTNS), poly-progression free survival (PPFS). RESULTS: The study included 64 patients with a total of 90 lesions treated with SBRT. LC at 1 and 2 years was 94.9 %, 91 % at 3 years. Median local control was not reached. Median OS was 16.5 months, OS at 1, 2 and 3 years was 87.5 %, 60.9 % and 51.9 %, respectively. Median DMFS was 8.3 months, DMFS at 1, 2 and 3 years was 38.1 %, 20.6 % and 16 % respectively. At univariate analysis, local response to SBRT was found to be statistically linked with better OS, DMFS and STFS. CONCLUSION: SBRT is a safe and valid option in oligometastatic breast cancer patients, with very high rates of local control. An optimal selection of patients is likely needed to improve survival outcomes and reduce the rate of distant progression.


Assuntos
Neoplasias da Mama , Neoplasias Hepáticas , Neoplasias Pulmonares , Radiocirurgia , Humanos , Feminino , Neoplasias da Mama/patologia , Neoplasias da Mama/radioterapia , Neoplasias da Mama/mortalidade , Radiocirurgia/métodos , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/cirurgia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/mortalidade , Pessoa de Meia-Idade , Estudos Prospectivos , Idoso , Adulto , Idoso de 80 Anos ou mais
3.
Radiother Oncol ; 190: 109969, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37922993

RESUMO

BACKGROUND AND PURPOSE: Advances in characterizing cancer biology and the growing availability of novel targeted agents and immune therapeutics have significantly changed the prognosis of many patients with metastatic disease. Palliative radiotherapy needs to adapt to these developments. In this study, we summarize the available evidence for stereotactic body radiotherapy (SBRT) in the treatment of spinal metastases. MATERIALS AND METHODS: A systematic review and meta-analysis was performed using PRISMA methodology, including publications from January 2005 to September 2021, with the exception of the randomized phase III trial RTOG-0631 which was added in April 2023. Re-irradiation was excluded. For meta-analysis, a random-effects model was used to pool the data. Heterogeneity was assessed with the I2-test, assuming substantial and considerable as I2 > 50 % and I2 > 75 %, respectively. A p-value < 0.05 was considered statistically significant. RESULTS: A total of 69 studies assessing the outcomes of 7236 metastases in 5736 patients were analyzed. SBRT for spine metastases showed high efficacy, with a pooled overall pain response rate of 83 % (95 % confidence interval [CI] 68 %-94 %), pooled complete pain response of 36 % (95 % CI: 20 %-53 %), and 1-year local control rate of 94 % (95 % CI: 86 %-99 %), although with high levels of heterogeneity among studies (I2 = 93 %, I2 = 86 %, and 86 %, respectively). Furthermore, SBRT was safe, with a pooled vertebral fracture rate of 9 % (95 % CI: 4 %-16 %), pooled radiation induced myelopathy rate of 0 % (95 % CI 0-2 %), and pooled pain flare rate of 6 % (95 % CI: 3 %-17 %), although with mixed levels of heterogeneity among the studies (I2 = 92 %, I2 = 0 %, and 95 %, respectively). Only 1.7 % of vertebral fractures required surgical stabilization. CONCLUSION: Spine SBRT is characterized by a favorable efficacy and safety profile, providing durable results for pain control and disease control, which is particularly relevant for oligometastatic patients.


Assuntos
Radiocirurgia , Fraturas da Coluna Vertebral , Neoplasias da Coluna Vertebral , Humanos , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Neoplasias da Coluna Vertebral/radioterapia , Neoplasias da Coluna Vertebral/secundário , Prognóstico , Coluna Vertebral , Fraturas da Coluna Vertebral/etiologia , Dor/etiologia , Ensaios Clínicos Fase III como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto
4.
Radiother Oncol ; 190: 109966, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37925107

RESUMO

BACKGROUND AND PURPOSE: Recent progress in diagnostics and treatment of metastatic cancer patients have improved survival substantially. These developments also affect local therapies, with treatment aims shifting from short-term palliation to long-term symptom or disease control. There is consequently a need to better define the value of stereotactic body radiotherapy (SBRT) for the treatment of spinal metastases. METHODS: This ESTRO clinical practice guideline is based on a systematic literature review conducted according to PRISMA standards, which formed the basis for answering four key questions about the indication and practice of SBRT for spine metastases. RESULTS: The analysis of the key questions based on current evidence yielded 22 recommendations and 5 statements with varying levels of endorsement, all achieving a consensus among experts of at least 75%. In the majority, the level of evidence supporting the recommendations and statements was moderate or expert opinion, only, indicating that spine SBRT is still an evolving field of clinical research. Recommendations were established concerning the selection of appropriate patients with painful spine metastases and oligometastatic disease. Recommendations about the practice of spinal SBRT covered technical planning aspects including dose and fractionation, patient positioning, immobilization and image-guided SBRT delivery. Finally, recommendations were developed regarding quality assurance protocols, including description of potential SBRT-related toxicity and risk mitigation strategies. CONCLUSIONS: This ESTRO clinical practice guideline provides evidence-based recommendations and statements regarding the selection of patients with spinal metastases for SBRT and its safe implementation and practice. Enrollment of patients into well-designed prospective clinical trials addressing clinically relevant questions is considered important.


Assuntos
Radiocirurgia , Neoplasias da Coluna Vertebral , Humanos , Radiocirurgia/métodos , Estudos Prospectivos , Neoplasias da Coluna Vertebral/radioterapia , Neoplasias da Coluna Vertebral/secundário , Fracionamento da Dose de Radiação , Coluna Vertebral
5.
Clin Oncol (R Coll Radiol) ; 35(12): e649-e656, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37775459

RESUMO

AIMS: The definition of oligometastatic prostate cancer (OPCa) is currently based solely on the maximum number of detectable metastases, as there are no validated biomarkers available. The aim of this study was to identify novel predictive factors for OPCa patients who underwent metastases-directed therapy. MATERIALS AND METHODS: This monocentre, retrospective study included consecutive OPCa patients with a maximum of five metastases in up to two organs, detected with choline- or PSMA-positron emission tomography, who were treated with metastases-directed stereotactic body radiation therapy. Endpoints were overall survival and progression-free survival, assessed with Kaplan-Meier analysis. Univariate and multivariable Cox regression was carried out to evaluate the association between clinical factors and survival outcomes. RESULTS: Between 2009 and 2021, 163 patients and 320 metastases were treated with 226 stereotactic body radiation therapy courses. The median three-dimensional metastatic tumour volume was 4.1 cm3, with a range from 0.01 to 233.4 cm3. In total, 87 (53.4%), 21 (12.9%) and 55 (33.7%) metastases were classified as cN1, cM1a and cM1b, respectively. The median follow-up was 28.5 months. The rates of overall survival at 1, 3 and 5 years were 89.5% (95% confidence interval 83.4-93.4), 74.9% (95% confidence interval 66.1-81.7) and 57.2% (95% confidence interval 45.8-67.1), respectively. Multivariable analysis showed that overall survival reduced with the increase in three-dimensional total tumour volume (hazard ratio 1.93, 95% confidence interval 1.06-3.52; P = 0.030) and confirmed a significant difference between cN1 versus cM1a-b disease (hazard ratio 1.81, 95% confidence interval 1.01-3.25; P = 0.046). The cut-off value of total volume correlated with the highest risk of death was 20 cm3 (hazard ratio 2.37, 95% confidence interval 1.34-4.18; P = 0.003). The median progression-free survival was 17.8 months, with 1-, 3- and 5-year rates of 63.7% (95% confidence interval 55.4-70.9), 31.5% (95% confidence interval 22.8-40.6) and 24.7% (95% confidence interval 16.0-34.3). CONCLUSIONS: This study identified three-dimensional total tumour volume and the site of oligometastases as significant predictors of survival in OPCa patients treated with metastases-directed therapy. These parameters can potentially be used to personalised treatment and improve patient outcome.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Masculino , Humanos , Estudos Retrospectivos , Carga Tumoral , Neoplasias da Próstata/patologia , Intervalo Livre de Progressão , Tomografia por Emissão de Pósitrons , Radiocirurgia/métodos
6.
Phys Med ; 104: 129-135, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36401941

RESUMO

PURPOSE: Set up a lung SBRT end-to-end (e2e) test and perform a multicentre validation. MATERIAL AND METHODS: A group of medical physicists from four hospitals and the Italian Institute of Ionizing Radiation Metrology designed the present e2e test. One sub-group set up the test, while another tested its feasibility and ease of use. A satisfaction questionnaire was used to collect user feedback. Each participating centre (PC) received the ADAM breathing phantom, a microDiamond detector and radiochromic films. Following the e2e protocol, each PC performed its standard internal procedure for simulating, planning, and irradiating the phantom. Each PC uploaded its planning and treatment delivery data in a shared Google Drive. A single centre analyzed all the data. RESULTS: The e2e test was successfully performed by all PCs. Participants' comments indicated that ADAM was well suited to the purpose and the protocol well described. All PCs performed the test in static and dynamic modes. The ratio between measured and planned point dose obtained by PC1, PC2, PC3, PC4 was: 0.99, 0.96, 1.01 and 1.01 (static track) and 0.99, 1.02, 1.01 and 0.94 (dynamic track). The gamma passing rates (3 % global, 3 mm) between planned and measured dose maps were 98.5 %, 94.0 %, 99.1 % and 94.0 % (static track) and 99.5 %, 96.5 %, 86.0 % and 94.5 % (dynamic track) for PC1, PC2, PC3 and PC4, respectively. CONCLUSIONS: An e2e test for lung SBRT has been proposed and tested in a multicentre framework. The results and user feedback prove the validity of the proposed e2e test.


Assuntos
Pulmão , Humanos , Itália
7.
Phys Med ; 49: 139-146, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-28899649

RESUMO

INTRODUCTION: Nanochambers present some advantages in terms of energy independence and absolute dose measurement for small field dosimetry in the SBRT scenario. Characterization of a micro-chamber prototype was carried out both under flattened and flattening-filter-free (FFF) beams with particular focus on stem effect. METHODS: The study included characterization of leakage and stem effects, dose rate and dose per pulse dependence, measurement of profiles, and percentage depth doses (PDDs). Ion collection efficiency and polarity effects were measured and evaluated against field size and dose per pulse. The 6_MV, 6_MV_FFF and 10_MV FFF beams of a Varian EDGE were used. Output factors were measured for field sizes ranging from 0.8×0.8cm2 to 20×20cm2 and were compared with other detectors. RESULTS: The 2mm diameter of this chamber guarantees a high spatial resolution with low penumbra values. In orthogonal configuration a strong stem (and cable) effect was observed for small fields. Dose rate and dose per pulse dependence were <0.3% and 0.6% respectively for the whole range of considered values. The Nanochamber exhibits a field size (FS) dependence of the polarity correction >2%. The OF values were compared with other small field detectors showing a good agreement for field sizes >2×2cm2. The large field over-response was corrected applying kpol(FS). CONCLUSIONS: Nanochamber is an interesting option for small field measurements. The spherical shape of the active volume is an advantage in terms of reduced angular dependence. An interesting feature of the Nanochamber is its beam quality independence and, as a future development, the possibility to use it for small field absolute dosimetry.


Assuntos
Fótons/uso terapêutico , Radiometria/instrumentação , Radiocirurgia
8.
Radiat Oncol ; 12(1): 73, 2017 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-28449704

RESUMO

BACKGROUND: To evaluate a knowledge based planning model for RapidPlan (RP) generated for advanced head and neck cancer (HNC) patient treatments, as well its ability to possibly improve the clinical plan quality. The stability of the model was assessed also for a different beam geometry, different dose fractionation and different management of bilateral structures (parotids). METHODS: Dosimetric and geometric data from plans of 83 patients presenting HNC were selected for the model training. All the plans used volumetric modulated arc therapy (VMAT, RapidArc) to treat two targets at dose levels of 69.96 and 54.45 Gy in 33 fractions with simultaneous integrated boost. Two models were generated, the first separating the ipsi- and contra-lateral parotids, while the second associating the two parotids to a single structure for training. The optimization objectives were adjusted to the final model to better translate the institutional planning and dosimetric strategies and trade-offs. The models were validated on 20 HNC patients, comparing the RP generated plans and the clinical plans. RP generated plans were also compared between the clinical beam arrangement and a simpler geometry, as well as for a different fractionation scheme. RESULTS: RP improved significantly the clinical plan quality, with a reduction of 2 Gy, 5 Gy, and 10 Gy of the mean parotid, oral cavity and laryngeal doses, respectively. A simpler beam geometry was deteriorating the plan quality, but in a small amount, keeping a significant improvement relative to the clinical plan. The two models, with one or two parotid structures, showed very similar results. NTCP evaluations indicated the possibility of improving (NTCP decreasing of about 7%) the toxicity profile when using the RP solution. CONCLUSIONS: The HNC RP model showed improved plan quality and planning stability for beam geometry and fractionation. An adequate choice of the objectives in the model is necessary for the trade-offs strategies.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Modelos Teóricos , Garantia da Qualidade dos Cuidados de Saúde/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica
9.
Phys Med ; 44: 131-138, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28433508

RESUMO

Lung stereotactic body radiotherapy (SBRT) is an accurate and precise technique to treat lung tumors with high 'ablative' doses. Given the encouraging data in terms of local control and toxicity profile, SBRT has currently become a treatment option for both early stage lung cancer and lung oligometastatic disease in patients who are medically inoperable or refuse surgical resection. Dose-adapted fractionation schedules and ongoing prospective trials should provide further evidence of SBRT safety trying to reduce toxicities and complications. In this heterogeneous scenario, a non-systematic review of dose constraints for lung SBRT was performed, including the main organs at risk in the thorax.


Assuntos
Neoplasias Pulmonares/radioterapia , Órgãos em Risco/efeitos da radiação , Radiocirurgia/efeitos adversos , Humanos
10.
Eur J Surg Oncol ; 43(4): 735-742, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28131670

RESUMO

OBJECTIVE: To evaluate the efficacy and the feasibility of SBRT for selected patients with isolated local recurrence of pancreatic cancer after radical surgery. METHODS: A retrospective analysis was performed on patients treated with SBRT for isolated local recurrence from resected pancreatic adenocarcinoma, after multidisciplinary board evaluation. Prescription dose was 45 Gy in 6 fractions for all patients. Primary end-point was freedom from local progression (FFLP). Secondary end-points were overall survival (OS), progression free survival (PFS) and toxicity. Local control was defined according to RECIST criteria. Acute and late toxicity was scored according to the NCI Common Terminology Criteria for Adverse Events (CTCAE) v4.0. RESULTS: Between January 2011 and February 2015, 31 patients with isolated local recurrence of resected pancreatic cancer were treated with SBRT. Pancreato-duodenectomy (PD) was performed on 24 patients and distal pancreatectomy (DP) in 7 cases, all with radical resection (R0). Median local recurrence disease free interval (DFI) was 14 months. Median follow-up was 12 months. FFLP was 91% and 82% at 1 and 2-years, respectively. Median PFS was 9 months. Median OS was 18 months. At univariate analysis, OS was correlated with a DFI>18 months. No cases of acute G3 toxicity or greater occurred. CONCLUSIONS: SBRT seems to be an effective and safe therapeutic option for isolated local recurrence of pancreatic cancer after surgery. Encouraging local control rate, very low toxicity profile and effective pain control suggest the crucial role of SBRT in the treatment of these long-survivors selected patients.


Assuntos
Adenocarcinoma/radioterapia , Recidiva Local de Neoplasia/radioterapia , Pancreatectomia , Neoplasias Pancreáticas/radioterapia , Pancreaticoduodenectomia , Radiocirurgia , Adenocarcinoma/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Quimioterapia Adjuvante , Intervalo Livre de Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Terapia Neoadjuvante , Recidiva Local de Neoplasia/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Radioterapia Adjuvante , Estudos Retrospectivos , Taxa de Sobrevida , Tomografia Computadorizada por Raios X
11.
Clin Oncol (R Coll Radiol) ; 28(12): e173-e178, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27389021

RESUMO

AIMS: The aim of this phase II study was to evaluate the efficacy and toxicity of stereotactic body radiotherapy in patients with low or intermediate risk prostate cancer. MATERIALS AND METHODS: Biopsy-confirmed prostate cancer patients were enrolled, provided that they had the following characteristics: initial prostate-specific antigen (PSA) ≤ 20 ng/ml, Gleason Score < 7, International Prostate Symptom Score < 7. The treatment schedule was 35 Gy in five fractions, delivered with volumetric modulated arcs with flattening filter free beams. Toxicity was recorded according to CTCAE criteria v4.0. Biochemical failure was calculated according to the Phoenix definition. The Expanded Prostate Cancer Index Composite questionnaire was used to record health-related quality of life. RESULTS: Between December 2011 and March 2015, 90 patients were enrolled (53 low risk, 37 intermediate risk). The median age was 71 years (range 48-82). In total, 58 (64.5%) of the patients had Gleason Score=6, the remaining had Gleason Score=7.The median initial PSA was 6.9 ng/ml (range 2.7-17.0). Acute toxicity was mild, with 32.2 patients presenting grade 1 urinary toxicity and 32.2% of patients presenting grade 2 urinary toxicity, mainly represented by urgency, dysuria and stranguria. Rectal grade 1 toxicity was found in 15.5% of patients, whereas grade 2 toxicity was recorded in 6.6% of patients. Regarding late toxicity, grade 1 proctitis was recorded in 11.1% of patients and grade 1 urinary in 38.8%; only two events of grade 2 urinary toxicity were observed (transient urethral stenosis, resolved by a 24 h catheterisation). At a median follow-up of 27 months (6-62 months) only two intermediate risk patients experienced a biochemical failure. Health-related quality of life revealed a slight worsening in all the domains during treatment, with a return to baseline 3 months after treatment. CONCLUSIONS: Stereotactic body radiotherapy delivered using linac-based flattening filter free volumetric modulated arc radiotherapy in low and intermediate risk prostate cancer patients is associated with mild toxicity profiles and good patient-reported quality of life.


Assuntos
Neoplasias da Próstata/radioterapia , Radiocirurgia/métodos , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Aceleradores de Partículas , Antígeno Prostático Específico/sangue , Qualidade de Vida , Radiocirurgia/efeitos adversos , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Inquéritos e Questionários
12.
Phys Med ; 30(3): 296-300, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24076257

RESUMO

PURPOSE: To investigate the correlation between total monitor units (MU), dosimetric findings, and pre-treatment quality assurance for volumetric modulated arc therapy (VMAT) by RapidArc (RA). METHODS AND MATERIALS: Ten patients with breast cancer were considered. Dose prescriptions were: 48 Gy and 40.5 Gy in 15 fractions to, respectively, PTV(Boost) and PTVWholeBreast. A reference plan was optimized and four more plans using the "MU Objective", a tool for total MU controlling, were prepared imposing ± 20 and ± 50% total MU for inducing different complexities. Plan objectives were: D95% > 95% for both PTVs, and D2% < 107% for PTV(Boost); mean dose < 9.5 Gy and V20 Gy < 10% for ipsilateral lung; V18 Gy < 5% for heart; mean dose <3 Gy for controlateral breast; furthermore V5 Gy, V10 Gy, V20 Gy, and V30 Gy to body were minimized. Plans were evaluated in terms of technical parameters, dosimetric plan objectives findings and pre-treatment quality assurance (QA). RESULTS: Concerning PTVs, there were no significant differences for target coverage (D95%); mean doses for ipsilateral lung and controlateral breast, and V18 Gy for heart decreased with MUs increasing, reaching a plateau with reference plan. Body volume receiving low dose (V5-10 Gy) was minimized for reference plans. All plans had GAI (3 mm, 3%) > 95%. CONCLUSIONS: The data suggest that the best plan is the reference one, where the "MU Objective" tool was not used during optimisation. Nevertheless, it is advisable to use the "MU Objective" tool for re-planning when low GAI is found to increase its value. In this case, attention should be paid to OARs dose limits, since their values may be increased.


Assuntos
Neoplasias da Mama/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Órgãos em Risco/efeitos da radiação , Controle de Qualidade , Radiometria , Radioterapia de Intensidade Modulada/efeitos adversos , Estudos Retrospectivos
13.
Strahlenther Onkol ; 188(11): 990-6, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23053143

RESUMO

PURPOSE: In the present study, the acute toxicity profiles for prostate patients treated with simultaneous integrated boost (SIB) with volumetric modulated arcs in a hypofractionated regime are reported. PATIENTS AND METHODS: A total of 70 patients treated with RapidArc between May 2010 and September 2011 were retrospectively evaluated. Patients were stratified into low (36%), intermediate (49%), and high-risk (16%) groups. Target volumes (expanded to define the planning volumes (PTV)) were clinical target volume (CTV) 1: prostate; CTV2: CTV1 + seminal vesicles; CTV3: CTV2 + pelvic nodes. Low-risk patients received 71.4 Gy to PTV1; intermediate-risk 74.2 Gy to PTV1 and 61.6 or 65.5 Gy to PTV2; high-risk 74.2 Gy to PTV1, 61.6 or 65.5 Gy to PTV2, and 51.8 Gy to PTV3. All treatments were in 28 fractions. The median follow-up was 11 months (range 3.5-23 months). The acute rectal, gastrointestinal (GI) and genitourinary (GU) toxicities were scored according to EORTC/RTOG scales. RESULTS: Acute toxicities were recorded for the GU [G0 = 31/70 (44%), G1 = 22/70 (31%); G2 = 16/70 (23%); G3 = 1/70 (1%)], the rectum [G0 = 46/70 (66%); G1 = 12/70 (17%); G2 = 12/70 (17%); no G3], and the GI [G0 = 54/69 (77%); G1 = 11/69 (16%); G2 = 4/69 (6%); no G3]. Median time to rectal, GU, and GI toxicities were 27, 30, and 33 days, respectively. Only the GI toxicity correlated with stage and pelvic irradiation. Univariate analysis presented significant correlations between GI toxicity and intestinal irradiation (V(50 Gy) and V(60 Gy)). In the multivariate analysis, the only significant dosimetric variable was V(50 Gy) for the intestinal cavity. CONCLUSION: Moderate hypofractionation with SIB and RapidArc was shown to be safe, with acceptable acute toxicity. Longer follow-up is needed to assess late toxicity and clinical outcome.


Assuntos
Adenocarcinoma/radioterapia , Fracionamento da Dose de Radiação , Neoplasias da Próstata/radioterapia , Lesões por Radiação/etiologia , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/métodos , Adenocarcinoma/patologia , Idoso , Biomarcadores Tumorais/sangue , Terapia Combinada , Tomografia Computadorizada de Feixe Cônico/métodos , Estudos de Viabilidade , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estadiamento de Neoplasias , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/patologia , Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/efeitos adversos
14.
Strahlenther Onkol ; 188(6): 484-90, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22402870

RESUMO

PURPOSE: The goal of the work was to assess the role of RapidArc treatments in chest wall irradiation after mastectomy and determine the potential benefit of flattening filter free beams. METHODS AND MATERIAL: Planning CT scans of 10 women requiring post-mastectomy chest wall radiotherapy were included in the study. A dose of 50 Gy in 2 Gy fractions was prescribed. Organs at risk (OARs) delineated were heart, lungs, contralateral breast, and spinal cord. Dose-volume metrics were defined to quantify the quality of concurrent treatment plans assessing target coverage and sparing of OARs. Plans were designed for conformal 3D therapy (3DCRT) or for RapidArc with double partial arcs (RA). RapidArc plans were optimized for both conventional beams as well as for unflattened beams (RAF). The goal for this planning effort was to cover 100% of the planning target volume (PTV) with ≥ 90% of the prescribed dose and to minimize the volume inside the PTV receiving > 105% of the dose. The mean ipsilateral lung dose was required to be lower than 15 Gy and V(20 Gy) < 22%. Contralateral organ irradiation was required to be kept as low as possible. RESULTS: All techniques met planning objectives for PTV and for lung (3DCRT marginally failed for V(20 Gy)). RA plans showed superiority compared to 3DCRT in the medium to high dose region for the ipsilateral lung. Heart irradiation was minimized by RAF plans with ~4.5 Gy and ~15 Gy reduction in maximum dose compared to RA and 3DCRT, respectively. RAF resulted in superior plans compared to RA with respect to contralateral breast and lung with a reduction of ~1.7 Gy and 1.0 Gy in the respective mean doses. CONCLUSION: RapidArc treatment resulted in acceptable plan quality with superior ipsilateral tissue sparing compared to traditional techniques. Flattening filter free beams, recently made available for clinical use, might provide further healthy tissue sparing, particularly in contralateral organs, suggesting their applicability for large and complex targets.


Assuntos
Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/radioterapia , Carcinoma Ductal de Mama/cirurgia , Mastectomia , Fótons/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos , Parede Torácica/efeitos da radiação , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/patologia , Terapia Combinada , Feminino , Humanos , Irradiação Linfática/métodos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Dosagem Radioterapêutica , Radioterapia Adjuvante
15.
Strahlenther Onkol ; 188(1): 49-55, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22194030

RESUMO

INTRODUCTION: Cetuximab plus radiotherapy (RT) may be an effective alternative to chemoradiation in locally advanced head and neck squamous cell carcinoma (LASCCHN) patients. We analyzed a group of patients treated at our institute with cetuximab plus volumetric modulation arc therapy (VMAT) with the RapidArc technique in a simultaneous integrated boost (SIB) regime. The primary end point was the assessment of acute toxicity and the feasibility of the combined approach. MATERIALS AND METHODS: Between December 2008 and March 2010, 22 patients were submitted to IMRT-SIB plus cetuximab for radical intent in case of LASCCHN. None of the patients was suitable for chemotherapy because of important comorbidities (the majority suffered of heart chronic diseases). All patients underwent planning CT (additional image modalities were acquired for contouring purposes in the same treatment position: MRI in 12 and FDG-PET in 4 out of 22 patients). VMAT, by means of RapidArc, and SIB with two dose levels of 54.45 Gy and 69.96 Gy in 33 fractions were adopted. All patients included in the analysis were concomitantly treated with cetuximab: administration of the drug was initiated 1 week before RT at a loading dose of 400 mg/m(2) body surface area over a period of 120 min, follow by a weekly 60 min infusion of 250 mg/m(2) for the duration of RT. Patients were assessed for toxicities according to the Radiation Therapy Oncology Group (RTOG) criteria. RESULTS: All but 2 patients completed treatment and achieved the minimum follow-up of 12 months after the end of the treatment. Of the 22 patients, 18% (4 patients) showed grade 1, 36% (8 patients) grade 2, and 36% (8 patients) showed grade 3 dermatitis, while 9% (2 patients) had grade 1, 36% (8 patients) grade 2, and 45% (10 patients) had grade 3 mucositis/stomatitis. No grade 4 toxicities were recorded. Considering blood parameters, 3 cases of grade 1 anemia and 1 case of grade 2 thrombocytopenia were observed. Nobody required feeding tube placement during treatment. CONCLUSION: The here reported toxicity data are promising and encouraging in regard to the adoption of moderate hypofractionation with VMAT-SIB techniques, when cetuximab is concomitantly administered.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Antineoplásicos/uso terapêutico , Carcinoma de Células Escamosas/terapia , Quimiorradioterapia/métodos , Neoplasias Otorrinolaringológicas/terapia , Idoso , Idoso de 80 Anos ou mais , Anticorpos Monoclonais/efeitos adversos , Anticorpos Monoclonais Humanizados , Antineoplásicos/efeitos adversos , Carcinoma de Células Escamosas/mortalidade , Carcinoma de Células Escamosas/patologia , Cetuximab , Fracionamento da Dose de Radiação , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Estadiamento de Neoplasias , Órgãos em Risco , Neoplasias Otorrinolaringológicas/mortalidade , Neoplasias Otorrinolaringológicas/patologia , Lesões por Radiação/etiologia , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/métodos
16.
Br J Radiol ; 84(1002): 534-45, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21606069

RESUMO

OBJECTIVE: Quality assurance data from five centres were analysed to assess the reliability of RapidArc radiotherapy delivery in terms of machine and dosimetric performance. METHODS: A large group of patients was treated with RapidArc radiotherapy and treatment data recorded. Machine quality assurance was performed according to Ling et al (Int J Radiat Oncol Biol Phys 2008;72:575-81). In addition, treatment to a typical clinical case was delivered biweekly as a constancy check. Pre-treatment dosimetric validation of plan delivery was performed for each patient. All measurements and computations were performed at the depth of the maximum dose in water according to the GLAaS method using electronic portal imaging device measurements. Evaluation was carried out according to a gamma agreement index (GAI, the percentage of field area passing the test); the threshold dose difference was 3% and the threshold distance to agreement was 3 mm. RESULTS: A total of 275 patients (395 arcs) were included in the study. Mean delivery parameters were 31.0±20.0° (collimator angle), 4.7±0.5° s(-1) (gantry speed), 343±134 MU min(-1) (dose rate) and 1.6±1.4 min (beam-on time) for prescription doses ranging from 1.8 to 16.7 Gy/fraction. Mean deviations from the baseline dose rate and gantry speed ranged from -0.61% to 1.75%. Mean deviations from the baseline for leaf speed variation ranged from -0.73% to 0.41%. The mean GAI of repeated clinical fields was 99.2±0.2%. GAI varied from 84.7% to 100%; the mean across all patients was 97.1±2.4%. CONCLUSION: RapidArc can provide a reliable and accurate delivery of radiotherapy for a variety of clinical conditions.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde/normas , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia de Intensidade Modulada/instrumentação , Algoritmos , Desenho de Equipamento , Humanos , Radiometria/métodos , Radiometria/normas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/normas , Reprodutibilidade dos Testes
17.
Q J Nucl Med Mol Imaging ; 51(3): 214-23, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17464266

RESUMO

AIM: To evaluate the performance of the positron emission tomography (PET)/computed tomography (CT) Discovery-STE (D-STE) scanner for lesion detectability in two-dimensional (2D) and three-dimensional (3D) acquisition. METHODS: A NEMA 2001 Image-Quality phantom with 11 lesions (7-37 mm in diameter) filled with a solution of 18F (lesion/background concentration ratio: 4.4) was studied. 2D and 3D PET scans were sequentially acquired (10 min each) in list mode (LM). Each scan was unlisted into 4, 3 and 2-min scans. Ten [18F]FDG PET oncological patient studies were also evaluated. Each patient underwent a 3D PET/CT whole body scan, followed by a 2D PET scan (4 min LM) and a 3D PET scan (4 min LM) over a single field of view. Both 2D and 3D scans were unlisted in 3 and 2-min scans. Data were evaluated quantitatively by calculating quality measurements and qualitatively by two physicians who judged lesion detectability compared to statistical variations in background activity. RESULTS: Quantitative and qualitative evaluations showed the superiority of 3D over 2D across all measures of quality. In particular, lesion detectability was better in 3D than in 2D at equal scan times and 3D acquisition provided images comparable in quality to 2D in approximately half the time. Interobserver variability was lower in evaluation of 3D scans and lesion shape and volume were better depicted. CONCLUSION: In oncological applications, the D-STE system demonstrated good performance in 2D and 3D acquisition, while 3D exhibited better image quality, data accuracy and consistency of lesion detectability, resulting in shorter scan times and higher patient throughput.


Assuntos
Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Neoplasias/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Humanos , Imageamento Tridimensional/instrumentação , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação , Imagem Corporal Total/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...