Jpn J Radiol ; 36(5): 313-323, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29524169

RESUMO

Combined PET/MRI is a novel imaging method integrating the advances of functional and morphological MR imaging with PET applications that include assessment of myocardial viability, perfusion, metabolism of inflammatory tissue and tumors, as well as amyloid deposition imaging. As such, PET/MRI is a promising tool to detect and characterize ischemic and non-ischemic cardiomyopathies. To date, the greatest benefit may be expected for diagnostic evaluation of systemic diseases and cardiac masses that remain unclear in cardiac MRI, as well as for clinical and scientific studies in the setting of ischemic cardiomyopathies. Diagnosis and therapeutic monitoring of cardiac sarcoidosis has the potential of a possible 'killer-application' for combined cardiac PET/MRI. In this article, we review the current evidence and discuss current and potential future applications of cardiac PET/MRI.


Assuntos
Cardiopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/tendências , Imagem Multimodal/tendências , Tomografia por Emissão de Pósitrons/tendências
2.
Acta Radiol ; 59(12): 1422-1430, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29566549

RESUMO

BACKGROUND: Long-term intensive training induces physiological, morphological, and functional adaption of the athlete's heart. PURPOSE: To evaluate the development of athlete's heart during a mid-term follow-up of competitive athletes using cardiac magnetic resonance (CMR). MATERIAL AND METHODS: Eighteen competitive long-distance runners and triathletes (age 43 ± 13 years, 3 women) were prospectively examined in a longitudinal follow-up study 5.05 ± 0.6 years after baseline. CMR at 1.5-T was performed for functional and late gadolinium enhancement (LGE) imaging. Left ventricular (LV) and right ventricular (RV) end-diastolic volume (LVEDV, RVEDV) as well as ejection fraction (LVEF, RVEF), LV myocardial mass (LVMM), and atrial sizes were determined and compared to baseline in matched pairs statistics for paired difference. RESULTS: LVEDV (197 ± 38 mL vs. 196 ± 38 mL, paired difference -0.9 mL, P = 0.7) and LVEF (62 ± 7% vs. 62 ± 5%, paired difference 0.1%, P = 0.9) did not change during the follow-up period, whereas LVMM increased significantly (149 ± 31 g vs.164 ± 32 g, paired difference 14 g, P < 0.0001). RVEDV significantly increased from 221 ± 47 mL at baseline to 230 ± 52 mL (paired difference 10 mL, P = 0.0033). RVEF decreased from baseline 57 ± 8% to 53 ± 7% (paired difference -3%, P = 0.0234). Left atrial size showed no significant changes (24 ± 5 cm2 vs. 25 ± 6 cm2, paired difference 0.5 cm2, P = 0.17) and right atrial size increased significantly (30 ± 5 cm2 vs. 32 ± 4 cm2, paired difference 2 cm2, P = 0.0054). CONCLUSION: This study supports the theory of ongoing remodeling in an athlete's heart. Predominantly the right heart can further enlarge in a mid-term period. This response seems not linearly dependent on a steady, decreased, or increased training volume.


Assuntos
Atletas , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Função Ventricular/fisiologia , Adulto , Idoso , Meios de Contraste , Feminino , Seguimentos , Gadolínio , Humanos , Aumento da Imagem/métodos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
3.
Eur Radiol ; 28(5): 2134-2142, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29181587

RESUMO

OBJECTIVES: To compare the diagnostic accuracy between low-kilovolt peak (kVp) (≤ 100) and high-kVp (> 100) third-generation dual-source coronary CT angiography (CCTA) using a kVp-tailored contrast media injection protocol. METHODS: One hundred twenty patients (mean age = 62.6 years, BMI = 29.0 kg/m2) who underwent catheter angiography and CCTA with automated kVp selection were separated into two cohorts (each n = 60, mean kVp = 84 and 117). Contrast media dose was tailored to the kVp level: 70 = 40 ml, 80 = 50 ml, 90 = 60 ml, 100 = 70 ml, 110 = 80 ml, and 120 = 90 ml. Contrast-to-noise ratio (CNR) was measured. Two observers evaluated image quality and the presence of significant coronary stenosis (> 50% luminal narrowing). RESULTS: Diagnostic accuracy (sensitivity/specificity) with ≤ 100 vs. > 100 kVp CCTA was comparable: per patient = 93.9/92.6% vs. 90.9/92.6%, per vessel = 91.5/97.8% vs. 94.0/96.8%, and per segment = 90.0/96.7% vs. 90.7/95.2% (all P > 0.64). CNR was similar (P > 0.18) in the low-kVp vs. high-kVp group (12.0 vs. 11.1), as ws subjective image quality (P = 0.38). Contrast media requirements were reduced by 38.1% in the low- vs. high-kVp cohort (53.6 vs. 86.6 ml, P < 0.001) and radiation dose by 59.6% (4.3 vs. 10.6 mSv, P < 0.001). CONCLUSIONS: Automated tube voltage selection with a tailored contrast media injection protocol allows CCTA to be performed at ≤ 100 kVp with substantial dose reductions and equivalent diagnostic accuracy for coronary stenosis detection compared to acquisitions at > 100 kVp. KEY POINTS: • Low-kVp coronary CT angiography (CCTA) enables reduced contrast and radiation dose. • Diagnostic accuracy is comparable between ≤ 100 and > 100 kVp CCTA. • Image quality is similar for low- and high-kVp CCTA. • Low-kVp image acquisition is facilitated by automated tube voltage selection. • Tailoring contrast injection protocols to the automatically selected kVp-level is feasible.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Idoso , Feminino , Seguimentos , Humanos , Injeções Intra-Arteriais , Masculino , Pessoa de Meia-Idade , Curva ROC , Doses de Radiação
4.
Tex Heart Inst J ; 44(4): 252-259, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28878578

RESUMO

Using cardiac magnetic resonance, we tested whether a single-breath-hold approach to cardiac functional evaluation was equivalent to the established multiple-breath-hold method. We examined 39 healthy volunteers (mean age, 31.9 ± 11.4 yr; 22 men) by using 1.5 T with multiple breath-holds and our proposed single breath-hold. Left ventricular and right ventricular ejection fractions (LVEF and RVEF), LV and RV end-diastolic volumes (LVEDV and RVEDV), and LV myocardial mass (LVMM) were compared by using Bland-Altman plots; LVEF and RVEF were tested for equivalence by inclusion of 95% confidence intervals (CIs). Equivalence of the methods was assumed within the range of -5% to 5%. In the multiple- versus the single-breath-hold method, LVEF was 0.62 ± 0.05 versus 0.62 ± 0.04, and RVEF was 0.59 ± 0.06 versus 0.59 ± 0.07. The mean difference in both methods was -0.2% (95% CI, -1 to 0.6) for LVEF and 0.3% (95% CI, -0.8 to 1.5) for RVEF. The mean differences between methods fit within the predetermined range of equivalence, including the 95% CI. The mean relative differences between the methods were 3.8% for LVEDV, 4.5% for RVEDV, and 1.6% for LVMM. Results of our single-breath-hold method to evaluate LVEF and RVEF were equivalent to those of the multiple-breath-hold technique. In addition, LVEDV, RVEDV, and LVMM showed low bias between methods.


Assuntos
Suspensão da Respiração , Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico , Função Ventricular Esquerda , Função Ventricular Direita , Adulto , Feminino , Voluntários Saudáveis , Coração/fisiologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo , Adulto Jovem
5.
Eur J Radiol ; 92: 11-16, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28624007

RESUMO

PURPOSE: To compare left ventricular global function index (LVGFI) and quantitative late gadolinium enhancement (LGE) in patients with unrecognized myocardial infarction (UMI), recognized myocardial infarction (RMI) and without myocardial infarction (MI). MATERIAL AND METHODS: Under waiver of the Institutional Review Board 235 patients (age 63.5±10.5years, 57 female) were retrospectively evaluated. All patients had undergone cardiac MRI at 1.5T for symptoms of CAD. 67 patients (29%) had suffered a known RMI before. Functional imaging and full-intensity late gadolinium enhancement (LGE) imaging were evaluated for LVGFI and quantitative LGE mass. RESULTS: Of 168 patients without history of RMI, 48 patients (29%) had UMI, 120 patients had no MI. LVGFI was lower in RMI patients (34±8% [range 16;52]), and UMI patients (35±8% [range 10;51]), compared to patients with no MI (38±7% [range 16;55]) respectively and similar between RMI and UMI patients. RMI patients had full-intensity LGE in 11±6% of left ventricular myocardial mass (LVMM). UMI patients had LGE in 9±5% of LVMM. RMI patients had significantly more LGE than UMI patients (p=0.0096). CONCLUSION: LGE quantification is effective to assess infarction scar size in RMI and UMI patients. LVGFI provides information on cardiac function and morphology but does not allow for a reliable differentiation between patients with and without history of MI, due small differences and wide overlap of LVGFI values for all three patient groups. This may be a reason why LVGFI is not applied in clinical routine.


Assuntos
Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/patologia , Débito Cardíaco , Cicatriz/patologia , Feminino , Gadolínio , Humanos , Estudos Retrospectivos
6.
J Comput Assist Tomogr ; 41(5): 804-810, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28448412

RESUMO

OBJECTIVES: The aim of this study was to investigate the minimum iodine delivery rate (IDR) and contrast media (CM) volume required for diagnostic contrast enhancement of 350 HU (Hounsfield units) in the ascending aorta at different kV settings. METHODS: Dynamic computed tomography acquisitions from 70 to 150 kV were performed in a circulation phantom. First, injections with IDR ranging from 0.1 to 2.0 g I/s were tested for each kV. In the second part, the IDR was held constant, whereas the CM volume was reduced from 50 to 10 mL. Diagnostic aortic peak enhancement for each kV was compared using the Kruskal-Wallis test. P < 0.05 was considered statistically significant. RESULTS: The mean aortic peak enhancement for all diagnostic IDRs was 368.7 ± 11.1 HU. Diagnostic IDRs returned similar aortic peak enhancement values for all protocols (all P ≥ 0.18). For the second part of the study, a diagnostic enhancement was yielded by using a minimum of 30 mL of CM for 110 kV, 25 mL for 100 and 90 kV, and 15 mL for 80 and 70 kV. CONCLUSION: Our study suggests that a differentiated approach reducing the CM volume for tube voltages of less than 120 kV and increasing the IDR for higher kV settings seems to be the most effective approach.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Iohexol/análogos & derivados , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Iohexol/administração & dosagem
7.
Eur Radiol ; 27(8): 3235-3243, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28050692

RESUMO

OBJECTIVES: To evaluate the influence of inversion time (TI) on the precision of myocardial late gadolinium enhancement (LGE) quantification using synthetic inversion recovery (IR) imaging in patients with myocardial infarction (MI). METHODS: Fifty-three patients with suspected prior MI underwent 1.5-T cardiac MRI with conventional magnitude (MagIR) and phase-sensitive IR (PSIR) LGE imaging and T1 mapping at 15 min post-contrast. T1-based synthetic MagIR and PSIR images were calculated with a TI ranging from -100 to +150 ms at 5-ms intervals relative to the optimal TI (TI0). LGE was quantified using a five standard deviation (5SD) and full width at half-maximum (FWHM) thresholds. Measurements were compared using one-way analysis of variance. RESULTS: The MagIRsy technique provided precise assessment of LGE area at TIs ≥ TI0, while precision was decreased below TI0. The LGE area showed significant differences at ≤ -25 ms compared to TI0 using 5SD (P < 0.001) and at ≤ -65 ms using the FWHM approach (P < 0.001). LGE measurements did not show significant difference over the analysed TI range in the PSIRsy images using either of the quantification methods. CONCLUSIONS: T1 map-based PSIRsy images provide precise quantification of MI independent of TI at the investigated time point post-contrast. MagIRsy-based MI quantification is precise at TI0 and at longer TIs while showing decreased precision at TI values below TI0. KEY POINTS: • Synthetic IR imaging retrospectively generates LGE images at any theoretical TI • Synthetic IR imaging can simulate the effect of TI on LGE quantification • Fifteen minutes post-contrast MagIR sy accurately quantifies infarcts from TI 0 to TI 0 + 150 ms • Fifteen minutes post-contrast PSIR sy provides precise infarct size independent of TI • Synthetic IR imaging has further advantages in reducing operator dependence.


Assuntos
Meios de Contraste/administração & dosagem , Gadolínio/administração & dosagem , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Adulto , Idoso , Análise de Variância , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
8.
Radiol Med ; 122(4): 280-287, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28070843

RESUMO

PURPOSE: To evaluate noise-optimized monoenergetic postprocessing of dual-energy CT (DE-CT) on image quality in patients with incidental pulmonary embolism in single-pass portal-venous phase CT (CTpv). MATERIALS AND METHODS: 20 Consecutive patients with incidental pulmonary embolism in contrast-enhanced oncological follow-up DE-CTpv examination were included in this study. Images were acquired with a 3rd generation DE-CT system in DE mode (100/Sn150 kV) and activated tube current modulation 90 s after contrast agent administration. Subsequently, virtual monoenergetic images (MEI+) were reconstructed at five different keV levels (40, 55, 70, 85, 100) and compared to the standard linearly blended (M_0.8) CTpv images. Image quality was assessed qualitatively (vascular contrast and detectability of embolism, image noise, iodine influx artifact; two independent readers; 5-point Likert scale; 5 = excellent) and quantitatively by calculating signal-to-noise (SNR) and contrast-to-noise ratios (CNR). RESULTS: Highest vessel contrast and highest detectability of embolism were observed in MEI+ at 40 keV (4.7 ± 0.4) and 55 keV (4.2 ± 0.6) with significant differences as compared to CTpv (3.6 ± 0.5) and high keV reconstructions (70, 85, 100; p ≤ 0.01). Image noise significantly increased at 40 keV MEI+ compared to all other MEI+ reconstructions and CTpv (p < 0.001). SNR and CNR calculations were highest at 40 keV MEI+ followed by 55 keV and CTpv with significant differences to high keV MEI+ (85-100). CONCLUSIONS: Computed MEI+ at low keV levels allow for improved vessel contrast and visualisation of incidental pulmonary embolism in patients with portal-venous phase CT scans by substantially increasing CNR and SNR.


Assuntos
Neoplasias/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Feminino , Humanos , Achados Incidentais , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Razão Sinal-Ruído
9.
Eur J Radiol ; 86: 276-283, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28027760

RESUMO

PURPOSE: To assess image quality and accuracy of CT angiography (CTA) for transcatheter aortic valve replacement (TAVR) planning performed with 3rd generation dual-source CT (DSCT). MATERIAL AND METHODS: We evaluated 125 patients who underwent TAVR-planning CTA on 3rd generation DSCT. A two-part protocol was performed including retrospectively ECG-gated coronary CTA (CCTA) and prospectively ECG-triggered aortoiliac CTA using 60mL of contrast medium. Automated tube voltage selection and advanced iterative reconstruction were applied. Effective dose (ED), signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated. Five-point scales were used for subjective image quality analysis. In patients who underwent TAVR, sizing parameters were obtained. RESULTS: Image quality was rated good to excellent in 97.6% of CCTA and 100% of aortoiliac CTAs. CTA studies at >100kV showed decreased objective image quality compared to 70-100kV (SNR, all p≤0.0459; CNR, all p≤0.0462). Mean ED increased continuously from 70 to >100kV (CCTA: 4.5±1.7mSv-13.6±2.9mSv, all p≤0.0233; aortoiliac CTA: 2.4±0.9mSv-6.8±2.7mSv, all p≤0.0414). In 39 patients TAVR was performed and annulus diameter was within the recommended range in all patients. No severe cardiac or vascular complications were noted. CONCLUSION: 3rd generation DSCT provides diagnostic image quality in TAVR-planning CTA and facilitates reliable assessment of TAVR device and delivery option while reducing radiation dose.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Algoritmos , Estenose da Valva Aórtica/cirurgia , Meios de Contraste , Angiografia Coronária/métodos , Feminino , Humanos , Masculino , Doses de Radiação , Exposição à Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos
10.
Eur Radiol ; 27(5): 1944-1953, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27553939

RESUMO

PURPOSE: To investigate feasibility, image quality and safety of low-tube-voltage, low-contrast-volume comprehensive cardiac and aortoiliac CT angiography (CTA) for planning transcatheter aortic valve replacement (TAVR). MATERIALS AND METHODS: Forty consecutive TAVR candidates prospectively underwent combined CTA of the aortic root and vascular access route (270 mgI/ml iodixanol). Patients were assigned to group A (second-generation dual-source CT [DSCT], 100 kV, 60 ml contrast, 4.0 ml/s flow rate) or group B (third-generation DSCT, 70 kV, 40 ml contrast, 2.5 ml/s flow rate). Vascular attenuation, noise, signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were compared. Subjective image quality was assessed by two observers. Estimated glomerular filtration (eGFR) at CTA and follow-up were measured. RESULTS: Besides a higher body-mass-index in group B (24.8±3.8 kg/m2 vs. 28.1±5.4 kg/m2, P=0.0339), patient characteristics between groups were similar (P≥0.0922). Aortoiliac SNR (P=0.0003) was higher in group B. Cardiac SNR (P=0.0003) and CNR (P=0.0181) were higher in group A. Subjective image quality was similar (P≥0.213) except for aortoiliac image noise (4.42 vs. 4.12, P=0.0374). TAVR-planning measurements were successfully obtained in all patients. There were no significant changes in eGFR among and between groups during follow-up (P≥0.302). CONCLUSION: TAVR candidates can be safely and effectively evaluated by a comprehensive CTA protocol with low contrast volume using low-tube-voltage acquisition. KEY POINTS: • Third-generation dual-source CT facilitates low-tube-voltage acquisition. • TAVR planning can be performed with reduced contrast volume and radiation dose. • TAVR-planning CT did not result in changes in creatinine levels at follow-up. • TAVR candidates can be safely evaluated by comprehensive low-tube-voltage CT angiography.


Assuntos
Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Masculino , Planejamento de Assistência ao Paciente , Doses de Radiação , Estudos Retrospectivos , Ácidos Tri-Iodobenzoicos
11.
J Magn Reson Imaging ; 45(5): 1429-1437, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27690324

RESUMO

PURPOSE: To evaluate a new dark-blood late gadolinium enhancement (LGE) technique called "T(Rho) And Magnetization transfer and INvErsion Recovery" (TRAMINER) for the ability to detect myocardial LGE versus standard "bright-blood" inversion recovery (SIR) imaging. MATERIALS AND METHODS: This Institutional Review Board (IRB)-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant prospective study included 40 patients (62 ± 14 years [mean ± standard deviation (SD)], 29 males) with suspected myocardial infarction (MI) referred for the assessment of myocardial viability. The patients underwent a 1.5T cardiac magnetic resonance imaging (MRI) including postcontrast SIR and TRAMINER acquisitions. Normalized images were evaluated by two readers. Subjective (3-point Likert scale) and objective image qualities were compared using Mann-Whitney U-test and paired t-test, respectively. Interobserver agreement, LGE detection rate, and level of certainty were compared using Cohen's kappa, Wilcoxon-test, and Mann-Whitney U-test, respectively. Results are reported as mean ± SD or mean [95% confidence interval]. RESULTS: Overall, image quality was rated similar between TRAMINER and SIR; however, TRAMINER performed better on a visual assessment of the ability to differentiate LGE from blood (Likert scale: 3.0 [3.0-3.0] vs. 2.0 [1.7-2.2], P < 0.0001). TRAMINER provided significantly higher signal intensity range (69.8 ± 10.2 vs. 9.6 ± 7.6, P < 0.0001) and a 4-fold higher signal intensity ratio (4.2 ± 1.9 vs. 1.1 ± 0.1, P < 0.0001) between LGE and blood signals. TRAMINER detected more patients (19/40 vs. 17/40) and segments (91/649 vs. 79/649) with LGE with higher level of certainty (2.9 [2.8-3.0] vs. 2.7 [2.5-2.8], P = 0.0185). Interobserver agreement was good to excellent for LGE detection. CONCLUSION: TRAMINER provides better contrast between LGE and blood and consequently may have increased ability to discriminate thin subendocardial and papillary muscle enhancement from the blood signal, which can have an indistinct appearance using SIR. LEVEL OF EVIDENCE: 2 J. MAGN. RESON. IMAGING 2017;45:1429-1437.


Assuntos
Gadolínio/química , Imageamento por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Miocárdio/patologia , Idoso , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes
12.
Eur Radiol ; 27(6): 2298-2308, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27682312

RESUMO

PURPOSE: To investigate diagnostic accuracy of 3rd-generation dual-source CT (DSCT) coronary angiography in obese and non-obese patients. METHODS: We retrospectively analyzed 76 patients who underwent coronary CT angiography (CCTA) and invasive coronary angiography. Prospectively ECG-triggered acquisition was performed with automated tube voltage selection (ATVS). Patients were dichotomized based on body mass index in groups A (<30 kg/m2, n = 37) and B (≥30 kg/m2, n = 39) and based on tube voltage in groups C (<120 kV, n = 46) and D (120 kV, n = 30). Coronary arteries were assessed for significant stenoses (≥50 % luminal narrowing) and diagnostic accuracy was calculated. RESULTS: Per-patient overall sensitivity, specificity, positive predictive value, negative predictive value (NPV) and accuracy were 96.9 %, 95.5 %, 93.9 %, 97.7 % and 96.1 %, respectively. Sensitivity and NPV were lower in groups B and D compared to groups A and C, but no statistically significant differences were observed (group A vs. B: sensitivity, 100.0 % vs. 93.3 %, p = 0.9493; NPV, 100 % vs. 95.5 %, p = 0.9812; group C vs. D: sensitivity, 100.0 % vs. 92.3 %, p = 0.8462; NPV, 100.0 % vs. 94.1 %, p = 0.8285). CONCLUSION: CCTA using 3rd-generation DSCT and (ATVS) provides high diagnostic accuracy in both non-obese and obese patients. KEY POINTS: • Coronary CTA provides high diagnostic accuracy in non-obese and obese patients. • Diagnostic accuracy between obese and non-obese patients showed no significant difference. • <120 kV studies were performed in 44 % of obese patients. • Current radiation dose-saving approaches can be applied independent of body habitus.


Assuntos
Angiografia por Tomografia Computadorizada/normas , Angiografia Coronária/normas , Obesidade/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
13.
Invest Radiol ; 52(3): 142-147, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27548345

RESUMO

OBJECTIVES: The aim of this study was to evaluate the diagnostic accuracy of virtual monoenergetic images (MEI+) at low kiloelectronvolt levels for the detection of incidental pulmonary embolism (PE) in oncological follow-up portal-venous phase dual-energy (DE-CTpv) staging. MATERIALS AND METHODS: Twenty-six patients with incidental PE in DE-CTpv staging, which was confirmed by computed tomography pulmonary angiography (CTPA), were included in this study. In addition, 26 matched control patients who were negative for PE in both DE-CTpv and CTPA were included. All examinations were performed on a third-generation DE-CT system in single-energy (CTPA) and dual-energy mode (DE-CTpv). Subsequently, 2 series of MEI+ data sets were reconstructed at 40 and 55 keV from the DE-CTpv data and compared with CTPA and the linearly blended CTpv images. Diagnostic accuracy and diagnostic confidence were calculated and compared for MEI+ reconstructions and for CTpv images regarding the detection of PE with CTPA as standard of reference. RESULTS: In 3 patients, PE was only detectable in CTPA and in the 40-kV and 55-kV MEI+ reconstructions but not in CTpv images. Diagnostic accuracy increased significantly for both MEI+ series (40 keV; area under the curve [AUC], 0.928; 95% confidence interval [CI], 0.879-0.978; 55 keV; AUC, 0.960; 95% CI, 0.922-0.998) as compared with CTpv (AUC, 0.814; 95% CI, 0.741-0.887; P ≤ 0.004). Diagnostic confidence was rated highest in CTPA (median, 5; range, 3-5) followed by 55-keV MEI+ and 40-keV MEI+ (median, 5; range, 2-5 and median, 5; range, 2-5, respectively) and was lowest for CTpv (median, 4; range, 1-5), with significant differences to CTPA and MEI+ reconstructions (P ≤ 0.001). CONCLUSIONS: Monoenergetic image reconstructions from DE-CT data sets at low kiloelectronvolt levels improve diagnostic accuracy for the detection of incidental PE in oncological follow-up DE-CTpv staging, with the highest subjective diagnostic confidence in MEI+ at 55 keV.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Achados Incidentais , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ruído , Veia Porta/diagnóstico por imagem , Veia Porta/fisiopatologia , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Embolia Pulmonar/fisiopatologia , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Reprodutibilidade dos Testes , Razão Sinal-Ruído
14.
Eur Radiol ; 27(4): 1377-1385, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27510627

RESUMO

OBJECTIVES: To evaluate the use of dual-energy CT imaging of the lung perfused blood volume (PBV) for the detection of pulmonary fat embolism (PFE). METHODS: Dual-energy CT was performed in 24 rabbits before and 1 hour, 1 day, 4 days and 7 days after artificial induction of PFE via the right ear vein. CT pulmonary angiography (CTPA) and lung PBV images were evaluated by two radiologists, who recorded the presence, number, and location of PFE on a per-lobe basis. Sensitivity, specificity, and accuracy of CTPA and lung PBV for detecting PFE were calculated using histopathological evaluation as the reference standard. RESULTS: A total of 144 lung lobes in 24 rabbits were evaluated and 70 fat emboli were detected on histopathological analysis. The overall sensitivity, specificity and accuracy were 25.4 %, 98.6 %, and 62.5 % for CTPA, and 82.6 %, 76.0 %, and 79.2 % for lung PBV. Higher sensitivity (p < 0.001) and accuracy (p < 0.01), but lower specificity (p < 0.001), were found for lung PBV compared with CTPA. Dual-energy CT can detect PFE earlier than CTPA (all p < 0.01). CONCLUSION: Dual-energy CT provided higher sensitivity and accuracy in the detection of PFE as well as earlier detection compared with conventional CTPA in this animal model study. KEY POINTS: • Fat embolism occurs commonly in patients with traumatic bone injury. • Dual-energy CT improves diagnostic performance for pulmonary fat embolism detection. • Dual-energy CT can detect pulmonary fat embolism earlier than CTPA.


Assuntos
Embolia Gordurosa/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia/métodos , Animais , Modelos Animais de Doenças , Humanos , Artéria Pulmonar/diagnóstico por imagem , Coelhos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Abdom Radiol (NY) ; 42(3): 772-780, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27878637

RESUMO

OBJECTIVES: To determine the optimal window setting for displaying virtual monoenergetic reconstructions of third generation dual-source, dual-energy CT (DECT) angiography of the abdomen. METHODS: Forty-five patients were evaluated with DECT angiography (90/150 kV, 180/90 ref. mAs). Three datasets were reconstructed: standard linear blending (M_0.6), 70 keV traditional virtual monoenergetic (M70), and 40 keV advanced noise-optimized virtual monoenergetic (M40+). The best window setting (width and level, W/L) was assessed by two blinded observers and was correlated with aortic attenuation to obtain the Optimized W/L setting (O-W/L). Subjective image quality was assessed, and vessel diameters were measured to determine any possible influences between different W/L settings. Repeated measures of variance were used to evaluate comparison of W/L values, image quality, and vessel sizing between M_0.6, M70, and M40+. RESULTS: The Best W/L (B-W/L) for M70 and M40+ was 880/280 and 1410/450, respectively. Results from regression analysis inferred an O-W/L of 850/270 for M70 and 1350/430 for M40+. Significant differences for W and L were found between the Best and the Optimized W/L for M40+, and between M70 and M40+ for both the Best and Optimized W/L. No significant differences for vessel measurements were found using the O-W/L for M40+ compared to the standard M_0.6 (p ≥ 0.16), and significant differences were observed when using the B-W/L with M40+ compared to M_0.6 (p ≤ 0.04). CONCLUSION: In order to optimize virtual monoenergetic imaging with both traditional M70 and advanced M40+, adjusting the W/L settings is necessary. Our results suggest a W/L setting of 850/270 for M70 and 1350/430 for M40+.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Radiografia Abdominal/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Doenças Vasculares/diagnóstico por imagem , Idoso , Meios de Contraste , Feminino , Humanos , Iohexol , Masculino , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos
16.
Eur Radiol ; 27(2): 642-650, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27165140

RESUMO

OBJECTIVES: To compare single-energy (SECT) and dual-energy (DECT) abdominal CT examinations in matched patient cohorts regarding differences in radiation dose and image quality performed with second- and third-generation dual-source CT (DSCT). METHODS: We retrospectively analysed 200 patients (100 male, 100 female; mean age 61.2 ± 13.5 years, mean body mass index 27.5 ± 3.8 kg/m2) equally divided into four groups matched by gender and body mass index, who had undergone portal venous phase abdominal CT with second-generation (group A, 120-kV-SECT; group B, 80/140-kV-DECT) and third-generation DSCT (group C, 100-kV-SECT; group D, 90/150-kV-DECT). The radiation dose was normalised for 40-cm scan length. Dose-independent figure-of-merit (FOM) contrast-to-noise ratios (CNRs) were calculated for various organs and vessels. Subjective overall image quality and reader confidence were assessed. RESULTS: The effective normalised radiation dose was significantly lower (P < 0.001) in groups C (6.2 ± 2.0 mSv) and D (5.3 ± 1.9 mSv, P = 0.103) compared to groups A (8.8 ± 2.3 mSv) and B (9.7 ± 2.4 mSv, P = 0.102). Dose-independent FOM-CNR peaked for liver, kidney, and portal vein measurements (all P ≤ 0.0285) in group D. Subjective image quality and reader confidence were consistently rated as excellent in all groups (all ≥1.53 out of 5). CONCLUSIONS: With both DSCT generations, abdominal DECT can be routinely performed without radiation dose penalty compared to SECT, while third-generation DSCT shows improved dose efficiency. KEY POINTS: • Dual-source CT (DSCT) allows for single- and dual-energy image acquisition. • Dual-energy acquisition does not increase the radiation dose in abdominal DSCT. • Third-generation DSCT shows improved dose efficiency compared to second-generation DSCT. • Dose-independent figure-of-merit image contrast was highest with third-generation dual-energy DSCT. • Third-generation DSCT shows improved dose efficiency for SECT and DECT.


Assuntos
Doses de Radiação , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Abdome/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
17.
Acad Radiol ; 23(12): 1480-1489, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27614365

RESUMO

RATIONALE AND OBJECTIVES: Iterative reconstruction (IR) computed tomography (CT) techniques allow for radiation dose reduction while maintaining image quality. However, CT coronary artery calcium (CAC) scores may be influenced by certain IR algorithms. The aim of our study is to identify suitable correction factors to ensure consistency between IR and filtered back projection (FBP)-based CAC scoring. MATERIAL AND METHODS: A phantom study was performed to derive suitable correction factors for CAC scores and volume (VOL) values with advanced modeled iterative reconstruction (or ADMIRE) strength level 3 (ADM3) and 5 (ADM5) vs FBP. CT data from 40 patients were retrospectively analyzed, and CAC score and VOL values were obtained following reconstruction with FBP, ADM3, and ADM5. Linear regression analysis was performed to obtain correction factors. Results with and without application of the correction factors were compared. Inter-reader agreement for risk class stratification was analyzed. RESULTS: Phantom experiments determined a correction factor of 1.14 for ADM3 and 1.25 for ADM5. FBP-based CAC scores (897 ± 1413) were significantly higher than uncorrected scores with ADM3 (746 ± 1184, P ≤ .001) and ADM5 (640 ± 1036, P ≤ .001). After application of correction factors, no significant differences were found for CAC scores based on FBP (897 ± 1413) and ADM3 (853 ± 1353, P = .07). The inter-reader agreement for risk stratification was excellent (k = 0.91). CONCLUSION: ADM3 can be applied to CAC scoring with use of a correction factor. When applying a correction factor of 1.14, excellent agreement with standard FBP for both CAC score and VOL can be achieved.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Calcificação Vascular/diagnóstico por imagem , Algoritmos , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
18.
Eur J Radiol ; 85(10): 1893-1899, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27510361

RESUMO

Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Coração/diagnóstico por imagem , Humanos
19.
Eur J Radiol ; 85(5): 972-8, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27130058

RESUMO

PURPOSE: To compare, on an intra-individual basis, the effect of automated tube voltage selection (ATVS), integrated circuit detector and advanced iterative reconstruction on radiation dose and image quality of aortic CTA studies using 2nd and 3rd generation dual-source CT (DSCT). MATERIAL AND METHODS: We retrospectively evaluated 32 patients who had undergone CTA of the entire aorta with both 2nd generation DSCT at 120kV using filtered back projection (FBP) (protocol 1) and 3rd generation DSCT using ATVS, an integrated circuit detector and advanced iterative reconstruction (protocol 2). Contrast-to-noise ratio (CNR) was calculated. Image quality was subjectively evaluated using a five-point scale. Radiation dose parameters were recorded. RESULTS: All studies were considered of diagnostic image quality. CNR was significantly higher with protocol 2 (15.0±5.2 vs 11.0±4.2; p<.0001). Subjective image quality analysis revealed no significant differences for evaluation of attenuation (p=0.08501) but image noise was rated significantly lower with protocol 2 (p=0.0005). Mean tube voltage and effective dose were 94.7±14.1kV and 6.7±3.9mSv with protocol 2; 120±0kV and 11.5±5.2mSv with protocol 1 (p<0.0001, respectively). CONCLUSION: Aortic CTA performed with 3rd generation DSCT, ATVS, integrated circuit detector, and advanced iterative reconstruction allow a substantial reduction of radiation exposure while improving image quality in comparison to 120kV imaging with FBP.


Assuntos
Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/normas , Idoso , Dissecção Aórtica/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico por imagem , Aortografia/métodos , Aortografia/normas , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos
20.
Eur Radiol ; 26(12): 4380-4389, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26960541

RESUMO

PURPOSE: To evaluate the impact of noise-optimized virtual monochromatic imaging (VMI+) on stent visualization and accuracy for in-stent re-stenosis at lower extremity dual-energy CT angiography (DE-CTA). MATERIAL AND METHODS: We evaluated third-generation dual-source DE-CTA studies in 31 patients with prior stent placement. Images were reconstructed with linear blending (F_0.5) and VMI+ at 40-150 keV. In-stent luminal diameter was measured and contrast-to-noise ratio (CNR) calculated. Diagnostic confidence was determined using a five-point scale. In 21 patients with invasive catheter angiography, accuracy for significant re-stenosis (≥50 %) was assessed at F_0.5 and 80 keV-VMI+ chosen as the optimal energy level based on image-quality analysis. RESULTS: At CTA, 45 stents were present. DSA was available for 28 stents whereas 12 stents showed significant re-stenosis. CNR was significantly higher with ≤80 keV-VMI+ (17.9 ± 6.4-33.7 ± 12.3) compared to F_0.5 (16.9 ± 4.8; all p < 0.0463); luminal stent diameters were increased at ≥70 keV (5.41 ± 1.8-5.92 ± 1.7 vs. 5.27 ± 1.8, all p < 0.001) and diagnostic confidence was highest at 70-80 keV-VMI+ (4.90 ± 0.48-4.88 ± 0.63 vs. 4.60 ± 0.66, p = 0.001, 0.0042). Sensitivity, negative predictive value and accuracy for re-stenosis were higher with 80 keV-VMI+ (100, 100, 96.4 %) than F_0.5 (90.9, 94.1, 89.3 %). CONCLUSION: 80 keV-VMI+ improves image quality, diagnostic confidence and accuracy for stent evaluation at lower extremity DE-CTA. KEY POINTS: • The impact of noise-optimized virtual monochromatic imaging on stent visualization was assessed. • Virtual monochromatic imaging significantly improves stent lumen visualization and diagnostic confidence. • At 80 keV diagnostic performance for detection of in-stent restenosis was increased. • 80 keV virtual monochromatic images are recommended for stent evaluation of lower extremity vasculature.


Assuntos
Algoritmos , Angiografia por Tomografia Computadorizada/métodos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Stents , Adulto , Idoso , Feminino , Humanos , Isquemia/diagnóstico por imagem , Isquemia/terapia , Extremidade Inferior/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...