Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
BMC Nephrol ; 25(1): 134, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622507

RESUMO

BACKGROUND: In the post-marketing stage, cases of hypocalcemia associated with bisphosphonate preparations (BPs) have been reported in patients with decreased kidney function, despite warning against use of BPs in such patients in the package insert (PI) of Japan. The purpose of this study was to investigate the safety of BPs in patients with decreased kidney function. METHODS: The cohort study was conducted in patients with osteoporosis and newly prescribed bisphosphonate utilizing real-world data from MID-NET® in Japan. The adjusted hazard ratios (aHRs) for hypocalcemia (a corrected serum Ca level < 8.00 mg/dL) relative to the normal group were calculated in each decreased kidney function group (mild, moderate or severe group). RESULTS: A total of 14,551 patients were included in the analysis, comprising 2,601 (17.88%) with normal (eGFR ≥ 90 mL/min/1.73m2), 7,613 (52.32%) with mild (60 ≤ eGFR < 90 mL/min/1.73m2), 3,919 (26.93%) with moderate (30 ≤ eGFR < 60 mL/min/1.73m2), and 418 (2.87%) with severe kidney function (eGFR < 30 mL/min/1.73m2). The aHRs (95% confidence interval) for hypocalcemia were 1.85 (0.75-4.57), 2.30 (0.86-6.21), and 22.74 (8.37-61.78) in the mild, moderate, and severe groups, respectively. The increased risk of hypocalcemia depending on kidney function was also observed even when calculating the aHR for each specific BP such as alendronate sodium hydrate, minodronic acid hydrate, and sodium risedronate hydrate. Furthermore, similar results were obtained in the sensitivity analysis by altering the outcome definition to a 20% or more reduction in corrected serum Ca level from the baseline, as well as when focusing on patients with more than one laboratory test result per 30 days during the follow-up period. CONCLUSIONS: These findings suggest that the risk of hypocalcemia during BP prescription is higher in patients with decreased kidney function, particularly those with severely decreased kidney function. The quantitative real-world evidence on the safety risk of BPs obtained in this study has led to the PI revision describing a relationship between hypocalcemia risk and decreased kidney function as a regulatory action in Japan and will contribute to promoting the proper use of BPs with appropriate risk management in clinical practice.


Assuntos
Hipocalcemia , Humanos , Estudos de Coortes , Hipocalcemia/induzido quimicamente , Hipocalcemia/epidemiologia , Japão/epidemiologia , Difosfonatos/efeitos adversos , Rim
2.
Front Med (Lausanne) ; 10: 1294696, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38327270

RESUMO

Introduction: This study was conducted to understand the impact of package insert (PI) revision in Japan on 18 June 2019 to allow metformin use for patients with moderately decreased kidney function (30 ≤ estimated glomerular filtration rate (eGFR) < 60 mL/min/1.73 m2). Methods: A new user cohort design was employed to examine the prescription trend and the occurrence of lactic acidosis in patients prescribed metformin before and after PI revision using the Medical Information Database Network (MID-NET®). Results: From 12 May 2016 to 31 March 2020, 5,874 patients (before, n = 4,702; after, n = 1,172) were identified as new metformin users, including 1,145 patients (before, n = 914; after, n = 231) with moderately decreased kidney function. Although no marked changes in metformin prescription were observed before and after PI revision, the daily metformin dose at the first prescription decreased after PI revision. For both before and after PI revision, less than 10 cases of lactic acidosis occurred in all patients prescribed metformin, and no lactic acidosis was observed in patients with moderately decreased kidney function. Conclusion: The results of this study are useful for understanding the safety of metformin use in patients with decreased kidney function and suggest no worse impacts of PI revision in Japan, indicating no further safety concerns on metformin use in patients with moderately decreased kidney function under the situation with careful use and safety monitoring of metformin.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...