Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
3.
Arch Dis Child Fetal Neonatal Ed ; 101(5): F401-3, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26678879

RESUMO

BACKGROUND: Randomised trials suggest that high-flow (HF) therapy is comparable with continuous positive airway pressure (CPAP) for postextubation respiratory support in neonates, and HF has been widely adopted in neonatal intensive care. METHODS: We conducted a population-based study of very preterm infants born <32 weeks' gestation within the Australian and New Zealand Neonatal Network (ANZNN) data set from 2009 to 2012, who received respiratory support with HF. RESULTS: 3372 very preterm infants were treated with HF. HF use in this population increased significantly from 15% in 2009 to 35% in 2012. In 2012, 53% (542/1029) of extremely preterm infants born <28 weeks' gestation received HF. 98% (3308/3372) of infants had received endotracheal ventilation or CPAP prior to receiving HF. The maximum HF gas flow was ≤8 L/min in almost all infants. CONCLUSIONS: HF use in extremely preterm and very preterm infants increased significantly within the ANZNN from 2009 to 2012.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Pressão Positiva Contínua nas Vias Aéreas/estatística & dados numéricos , Lactente Extremamente Prematuro , Terapia Intensiva Neonatal/métodos , Terapia Intensiva Neonatal/estatística & dados numéricos , Austrália , Idade Gestacional , Humanos , Nova Zelândia
4.
Arch Dis Child Fetal Neonatal Ed ; 99(4): F291-5, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24625433

RESUMO

BACKGROUND: Noise exposure in the neonatal intensive care unit is believed to be a risk factor for hearing loss in preterm neonates. Continuous positive airway pressure (CPAP) devices exceed recommended noise levels. High flow nasal cannulae (HFNC) are an increasingly popular alternative to CPAP for treating preterm infants, but there are no in vivo studies assessing noise production by HFNC. OBJECTIVE: To study whether HFNC are noisier than bubble CPAP (BCPAP) for preterm infants. METHODS: An observational study of preterm infants receiving HFNC or BCPAP. Noise levels within the external auditory meatus (EAM) were measured using a microphone probe tube connected to a calibrated digital dosimeter. Noise was measured across a range of frequencies and reported as decibels A-weighted (dBA). RESULTS: A total of 21 HFNC and 13 BCPAP noise measurements were performed in 21 infants. HFNC gas flows were 2-5 L/min, and BCPAP gas flows were 6-10 L/min with set pressures of 5-7 cm of water. There was no evidence of a difference in average noise levels measured at the EAM: mean difference (95% CI) of -1.6 (-4.0 to 0.9) dBA for HFNC compared to BCPAP. At low frequency (500 Hz), HFNC was mean (95% CI) 3.0 (0.3 to 5.7) dBA quieter than BCPAP. Noise increased with increasing BCPAP gas flow (p=0.007), but not with increasing set pressure. There was a trend to noise increasing with increasing HFNC gas flows. CONCLUSIONS: At the gas flows studied, HFNC are not noisier than BCPAP for preterm infants.


Assuntos
Doenças do Prematuro/terapia , Ruído/efeitos adversos , Ventilação não Invasiva/instrumentação , Catéteres , Pressão Positiva Contínua nas Vias Aéreas/efeitos adversos , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Pressão Positiva Contínua nas Vias Aéreas/métodos , Monitoramento Ambiental/métodos , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Cavidade Nasal , Ventilação não Invasiva/efeitos adversos , Ventilação não Invasiva/métodos , Terminologia como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA