Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
mSystems ; 7(4): e0010922, 2022 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-35703436

RESUMO

A promising approach to help students safely return to in person learning is through the application of sentinel cards for accurate high resolution environmental monitoring of SARS-CoV-2 traces indoors. Because SARS-CoV-2 RNA can persist for up to a week on several indoor surface materials, there is a need for increased temporal resolution to determine whether consecutive surface positives arise from new infection events or continue to report past events. Cleaning sentinel cards after sampling would provide the needed resolution but might interfere with assay performance. We tested the effect of three cleaning solutions (BZK wipes, Wet Wipes, RNase Away) at three different viral loads: "high" (4 × 104 GE/mL), "medium" (1 × 104 GE/mL), and "low" (2.5 × 103 GE/mL). RNase Away, chosen as a positive control, was the most effective cleaning solution on all three viral loads. Wet Wipes were found to be more effective than BZK wipes in the medium viral load condition. The low viral load condition was easily reset with all three cleaning solutions. These findings will enable temporal SARS-CoV-2 monitoring in indoor environments where transmission risk of the virus is high and the need to avoid individual-level sampling for privacy or compliance reasons exists. IMPORTANCE Because SARS-CoV-2, the virus that causes COVID-19, persists on surfaces, testing swabs taken from surfaces is useful as a monitoring tool. This approach is especially valuable in school settings, where there are cost and privacy concerns that are eliminated by taking a single sample from a classroom. However, the virus persists for days to weeks on surface samples, so it is impossible to tell whether positive detection events on consecutive days are a persistent signal or new infectious cases and therefore whether the positive individuals have been successfully removed from the classroom. We compare several methods for cleaning "sentinel cards" to show that this approach can be used to identify new SARS-CoV-2 signals day to day. The results are important for determining how to monitor classrooms and other indoor environments for SARS-CoV-2 virus.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , RNA Viral , Endorribonucleases , Ribonuclease Pancreático , Ribonucleases
2.
mSystems ; 7(4): e0010322, 2022 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-35703437

RESUMO

Surface sampling for SARS-CoV-2 RNA detection has shown considerable promise to detect exposure of built environments to infected individuals shedding virus who would not otherwise be detected. Here, we compare two popular sampling media (VTM and SDS) and two popular workflows (Thermo and PerkinElmer) for implementation of a surface sampling program suitable for environmental monitoring in public schools. We find that the SDS/Thermo pipeline shows superior sensitivity and specificity, but that the VTM/PerkinElmer pipeline is still sufficient to support surface surveillance in any indoor setting with stable cohorts of occupants (e.g., schools, prisons, group homes, etc.) and may be used to leverage existing investments in infrastructure. IMPORTANCE The ongoing COVID-19 pandemic has claimed the lives of over 5 million people worldwide. Due to high density occupancy of indoor spaces for prolonged periods of time, schools are often of concern for transmission, leading to widespread school closings to combat pandemic spread when cases rise. Since pediatric clinical testing is expensive and difficult from a consent perspective, we have deployed surface sampling in SASEA (Safer at School Early Alert), which allows for detection of SARS-CoV-2 from surfaces within a classroom. In this previous work, we developed a high-throughput method which requires robotic automation and specific reagents that are often not available for public health laboratories such as the San Diego County Public Health Laboratory (SDPHL). Therefore, we benchmarked our method (Thermo pipeline) against SDPHL's (PerkinElmer) more widely used method for the detection and prediction of SARS-CoV-2 exposure. While our method shows superior sensitivity (false-negative rate of 9% versus 27% for SDPHL), the SDPHL pipeline is sufficient to support surface surveillance in indoor settings. These findings are important since they show that existing investments in infrastructure can be leveraged to slow the spread of SARS-CoV-2 not in just the classroom but also in prisons, nursing homes, and other high-risk, indoor settings.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Criança , COVID-19/diagnóstico , Pandemias/prevenção & controle , RNA Viral , Automação
3.
MMWR Morb Mortal Wkly Rep ; 68(42): 943-946, 2019 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-31647789

RESUMO

Vaccinia virus (VACV) is an orthopoxvirus used in smallpox vaccines, as a vector for novel cancer treatments, and for experimental vaccine research (1). The Advisory Committee on Immunization Practices (ACIP) recommends smallpox vaccination for laboratory workers who handle replication-competent VACV (1). For bioterrorism preparedness, the U.S. government stockpiles tecovirimat, the first Food and Drug Administration-approved antiviral for treatment of smallpox (caused by variola virus and globally eradicated in 1980*,†) (2). Tecovirimat has activity against other orthopoxviruses and can be administered under a CDC investigational new drug protocol. CDC was notified about an unvaccinated laboratory worker with a needlestick exposure to VACV, who developed a lesion on her left index finger. CDC and partners performed laboratory confirmation, contacted the study sponsor to identify the VACV strain, and provided oversight for the first case of laboratory-acquired VACV treated with tecovirimat plus intravenous vaccinia immunoglobulin (VIGIV). This investigation highlights 1) the misconception among laboratory workers about the virulence of VACV strains; 2) the importance of providing laboratorians with pathogen information and postexposure procedures; and 3) that although tecovirimat can be used to treat VACV infections, its therapeutic benefit remains unclear.


Assuntos
Pessoal de Laboratório , Ferimentos Penetrantes Produzidos por Agulha/virologia , Doenças Profissionais/terapia , Traumatismos Ocupacionais/virologia , Vacínia/terapia , Adulto , California , Feminino , Humanos
4.
J Clin Virol ; 58 Suppl 1: e44-7, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24342477

RESUMO

BACKGROUND: HIV screening assays have gone through several generations of development in an effort to narrow the "window period" of detection. Utilizing a fourth generation HIV screening assay has the potential to detect earlier HIV infection, thus reducing HIV-1 transmission. OBJECTIVE: To identify acute infections to decrease HIV transmission in San Diego County. STUDY DESIGN: Serum specimens were collected from clients seen by multiple submitters in San Diego County. All acceptable specimens were screened using the 4th Gen Combo Assay. Initially reactive specimens were repeated in duplicate and if repeatedly reactive, were confirmed by HIV-1 Immunofluorescent Antibody Assay (IFA). IFA negative/inconclusive specimens were sent for HIV-1 NAT and HIV-2 antibody testing to referral laboratories. BioRad Multispot HIV-1/HIV-2 Rapid Test was also performed on a subset of specimens. RESULTS: Of 14,559 specimens received in 20 months, 14,517 specimens were tested. Of the 14,517 specimens that were tested, a total of 279 (1.9%) specimens were CIA repeatedly reactive and 240 of the 279 confirmed by HIV-1 IFA. Thirty-nine gave IFA negative/inconclusive result and 30 were further tested for HIV-1 NAT and 36 for HIV-2 antibody. Thirteen specimens were considered false positives by CIA and 17 specimens were classified as acute infections. Eleven of 39 IFA negative/inconclusive specimens were further tested by Multispot. Five of the 11 were positive by Multispot. CONCLUSION: The fourth generation Abbott ARCHITECT HIV Ag/Ab Combo Assay identified 17 patients who may have been missed by the prior HIV-1 screening assay used at San Diego County Public Health Laboratory.


Assuntos
Testes Diagnósticos de Rotina/métodos , Anticorpos Anti-HIV/sangue , Antígenos HIV/sangue , Infecções por HIV/diagnóstico , HIV-1/classificação , HIV-2/classificação , RNA Viral/sangue , Algoritmos , California , Imunofluorescência/métodos , HIV-1/genética , HIV-1/imunologia , HIV-2/genética , HIV-2/imunologia , Humanos , Imunoensaio/métodos , Medições Luminescentes , Técnicas de Amplificação de Ácido Nucleico/métodos , Virologia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...