Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Radiol Prot ; 26(2): 199-211, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16738416

RESUMO

Exposures of the general public to radio waves at locations near 20 randomly selected GSM microcell and picocell base stations in the UK have been assessed in the context of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. Compliance distances were calculated for the antennas of the base stations from their reported radiated powers. Under pessimistic assumptions that would maximise exposures, the minimum height at which the general public reference level could potentially be exceeded near any of the base station antennas was calculated to be 2.4 m above ground level. The power densities of the broadcast carriers transmitted by the base stations have been measured and scaled to include all other possible carriers. Exposures were generally in the range 0.002-2% of the ICNIRP general public reference level, and the greatest exposure quotient near any of the base stations was 8.6%. Exposures close to microcell base stations were found to be generally greater than those close to macrocell base stations.


Assuntos
Telefone Celular , Exposição Ambiental/análise , Micro-Ondas , Monitoramento de Radiação/métodos , Ondas de Rádio , Medição de Risco/métodos , Doses de Radiação , Distribuição Aleatória , Fatores de Risco , Reino Unido
2.
Radiat Prot Dosimetry ; 111(2): 191-203, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15266067

RESUMO

The use of personal monitors for the assessment of exposure to radiofrequency fields and radiation in potential future epidemiological studies of occupationally exposed populations has been investigated. Data loggers have been developed for use with a commercially available personal monitor and these allowed personal exposure records consisting of time-tagged measurements of electric and magnetic field strength to be accrued over extended periods of the working day. The instrumentation was worn by workers carrying out tasks representative of some of their typical daily activities at a variety of radio sites. The results indicated significant differences in the exposures of workers in various RF environments. A number of measures of exposure have been examined with a view to assessing possible exposure metrics for epidemiological studies. There was generally a good correlation between a given measure of electric field strength and the same measure of magnetic field strength.


Assuntos
Campos Eletromagnéticos , Análise de Falha de Equipamento , Armazenamento e Recuperação da Informação/métodos , Monitorização Ambulatorial/instrumentação , Exposição Ocupacional/análise , Proteção Radiológica/instrumentação , Ondas de Rádio , Radiometria/instrumentação , Carga Corporal (Radioterapia) , Monitoramento Ambiental/métodos , Desenho de Equipamento , Estudos de Viabilidade , Humanos , Miniaturização , Monitorização Ambulatorial/métodos , Doses de Radiação , Proteção Radiológica/métodos , Radiometria/métodos , Reprodutibilidade dos Testes , Medição de Risco/métodos , Fatores de Risco , Sensibilidade e Especificidade , Telecomunicações
3.
Hum Genet ; 115(2): 104-11, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15141347

RESUMO

Rearrangements of chromosome 15q, including isodicentric 15 chromosomes and interstitial duplications and triplications, have been previously reported in association with autism spectrum disorders. We have identified two boys with exceptionally large der(15) chromosomes that are tricentric and contain four copies of the proximal long arm, including the Prader Willi/Angelman critical region, and leading to hexasomy of the involved segment. Biallelic inheritance of maternal alleles and methylation analysis indicate that the markers are maternally derived. Clinical assessment of the boys indicated severe cognitive impairment associated with marked delays in gross and fine motor skills. Social and language deficits were present in both, although the severity of the mental retardation precluded diagnosis of autism (both were considered to have pervasive developmental disorder-not otherwise specified). Neurologic manifestations included infantile spasms evolving into intractable early-onset myoclonic seizures, psychomotor regression, and profound diffuse hypotonia. These patients represent the most severe end of the spectrum of phenotypes associated with segmental aneuploidy for chromosome 15q11-q13.


Assuntos
Transtornos Globais do Desenvolvimento Infantil/genética , Aberrações Cromossômicas , Cromossomos Humanos Par 15 , Epilepsia/genética , Anormalidades Múltiplas/genética , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Deficiência Intelectual/genética , Masculino
7.
Phys Med Biol ; 39(10): 1537-53, 1994 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15551530

RESUMO

A new mathematical model of the head has been constructed from a set of serial MRI slices from one subject. Finite-difference time-domain (FDTD) calculations of the specific energy absorption rate (SAR) have been performed on this model with a 2 mm resolution for a generic mobile communication transceiver represented by a quarter-wavelength monopole on a metal box. The antenna was mounted either at the centre or corner of the top face of the box. The frequencies considered were 900 MHz and 1.8 GHz. Three irradiation geometries were considered, a vertical handset in front of the eye and vertical and horizontal orientations at the side of the ear. The effect of a hand grasping the handset was considered. The head model was scaled to represent the head of an infant and a subset of calculations was performed to verify that the SAR deposited in the infant head did not exceed that in the adult. Results are also presented for a half-wavelength dipole. The maximum SAR values produced by the generic transceiver for the horizontal orientation at the side of the head which is the most typical position, averaged over 10 g of tissue at 900 MHz and 1.8 GHz, are 2.1 and 3.0 W kg(-1) per W of radiated power. The corresponding values over 1 g of tissue are 2.3 and 4.8 W kg(-1) per W at 900 MHz and 1.8 GHz. However, if one were to consider all possible operational conditions, the placement of the transceiver in front of the eye will give 3.1 and 4.6 W kg(-1) per W averaged over 10 g of tissue and 4.7 and 7.7 W kg(-1) per W over 1 g of tissue at 900 MHz and 1.8 GHz, respectively.


Assuntos
Algoritmos , Telefone Celular , Cabeça/anatomia & histologia , Cabeça/fisiologia , Micro-Ondas , Proteção Radiológica/métodos , Radiometria/métodos , Adulto , Carga Corporal (Radioterapia) , Cabeça/efeitos da radiação , Humanos , Transferência Linear de Energia/fisiologia , Masculino , Especificidade de Órgãos , Doses de Radiação , Eficiência Biológica Relativa , Medição de Risco/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...