Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(13)2022 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-35808271

RESUMO

In this study, we present a procedure to optimize a set of finite impulse response filter (FIR) coefficients for digital pulse-amplitude measurement. Such an optimized filter is designed using an adapted digital penalized least mean square (DPLMS) method. The effectiveness of the procedure is demonstrated using a dataset from a case study on high-resolution X-ray spectroscopy based on single-photon detection and energy measurements. The energy resolutions of the Kα and Kß lines of the Manganese energy spectrum have been improved by approximately 20%, compared to the reference values obtained by fitting individual photon pulses with the corresponding mathematical model.


Assuntos
Análise de Dados , Processamento de Sinais Assistido por Computador , Modelos Teóricos , Análise Espectral , Raios X
2.
Talanta ; 183: 158-163, 2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29567158

RESUMO

In the thermal lens experimental set-up we replaced the commonly employed pump laser by a halogen lamp, combined with an interference filter, providing a tuneable, nearly monochromatic pump source over the range of wavelengths 430-710 nm. Counter-propagating pump and probe beams are used and a 1 mm path-length sample cell together with the interference filter makes an optical cavity, providing amplification of the thermal lens signal, which leads to enhancement of the measurement sensitivity, and enables detection of absorbances on the order of 5 × 10-6. Amplified thermal lens signal allows us to replace the typical lock-in amplifier and digital oscilloscope with a silicon photodetector, Arduino, and a personal computer, offering the possibility for a compact, robust and portable device, useful for in-field absorption measurements in low concentration or weakly absorbing species. The use of a white light source for optical pumping, an interference filter for wavelength selection and direct diagnostic of the thermal lens signal increase the versatility of the instrument and simplifies substantially the experimental setup. Determination of Fe(II) concentrations at parts per billion levels was performed by the described white-light thermal lens spectrophotometer and the absorption spectrum for 50 µgL-1 Fe(II)-1,10-phenanthroline was well reproduced with an average measurement precision of 4%. The obtained limits of detection and quantitation of Fe(II) determination at 510 nm are 3 µgL-1 and 11 µgL-1, respectively. The calibration curve was linear in the concentration range of LOQ-500 µgL-1 with reproducibility between 2% and 6%, confirming that this instrument provides good spectrometric capabilities such as high sensitivity, tuneability and good reproducibility. In addition, the versatility of the instrument was demonstrated by recording the photothermal spectrum of gold nanostructured material and determination of excitation wavelength with most efficient optical to thermal energy conversion, which differs considerably (cca 100 nm) from the absorption maximum of the investigated sample.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA