1.
Artigo em Inglês | MEDLINE | ID: mdl-38662577

RESUMO

PURPOSE: To investigate the long-term astigmatism after combined non-penetrating glaucoma surgery (NPGS) and implantation of the first miniaturized suprachoroidal intraocular pressure (IOP) sensor EYEMATE-SC. SETTING: The study was conducted in five medical centers in two different countries. DESIGN: Retrospective multicenter clinical study. METHODS: Astigmatism of patients instrumented with the EYEMATE-SC IOP sensor was assessed over a follow-up period of three years. Refraction and corrected distance visual acuity (CDVA) were obtained preoperatively, after 6 months, 1, 2, and 3 years. A canaloplasty-operated patient cohort served as control. Astigmatism was evaluated using 3-dimensional power vector analysis involving the spherical equivalent M, and the Jackson crossed cylinder projections J0 and J45. Exclusion criteria included neovascular and angle-closure glaucoma, myopia, axial length outside 22 to 26 mm, other ocular diseases, prior glaucoma surgery, other ocular surgery within 6 months (cataract surgery within 3 months) prior to NPGS, serious generalized conditions, and other active medical head/neck implants. RESULTS: Multivariate analysis indicated no changes in astigmatism along the observation period in both the EYEMATE-SC (n = 24) and the canaloplasty (n = 24) group (P > 0.05 or nonsignificant after Bonferroni correction). Astigmatism was unchanged between the EYEMATE-SC and the canaloplasty group at all time points (P > 0.05). CDVA didn't change along the observation period of three years in each of both groups (P > 0.05). CONCLUSIONS: Despite its suprachoroidal localization, the present study indicates that the miniaturized EYEMATE-SC IOP sensor doesn't negatively affect the long-term astigmatism after combined implantation with NPGS.

2.
Br J Ophthalmol ; 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38408856

RESUMO

BACKGROUND: Intraocular pressure (IOP) monitoring in glaucoma management is evolving with novel devices. We investigated the reproducibility of 24 hour profiles on two consecutive days and after 30 days of self-measurements via telemetric IOP monitoring. METHODS: Seven primary patients with open-angle glaucoma previously implanted with a telemetric IOP sensor in one eye underwent automatic measurements throughout 24 hours on two consecutive days ('day 1' and 'day 2'). Patients wore an antenna adjacent to the study eye connected to a reader device to record IOP every 5 min. Also, self-measurements in six of seven patients were collected for a period of 30 days. Analysis included calculation of hourly averages to correlate time-pairs of day 1 versus day 2 and the self-measurements vers day 2. RESULTS: The number of IOP measurements per patient ranged between 151 and 268 on day 1, 175 and 268 on day 2 and 19 and 1236 during 30 days of self-measurements. IOP time-pairs of automatic measurements on day 1 and day 2 were significantly correlated at the group level (R=0.83, p<0.001) and in four individual patients (1, 2, 6 and 7). IOP time-pairs of self-measurements and day 2 were significantly correlated at the group level (R=0.4, p<0.001) and in four individual patients (2, 5, 6 and 7). CONCLUSIONS: Twenty-four hour automatic measurements of IOP are correlated on consecutive days and, though to a lesser degree, with self-measurements. Therefore a virtual 24-hour IOP curve might be constructed from self-measurements. Both options provide an alternative to frequent in-office IOP measurements.

3.
Am J Ophthalmol ; 260: 172-181, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38109951

RESUMO

PURPOSE: To evaluate the performance and safety of minimally invasive glaucoma surgery with a supraciliary drainage device (MINIject; iSTAR Medical, Wavre, Belgium) in primary open-angle glaucoma (POAG) as a stand-alone procedure. DESIGN: Meta-analysis. METHODS: At 11 sites in Colombia, France, Germany, India, Panama, and Spain, 82 patients were treated in 3 prospective, multicenter, interventional, nonrandomized trials (STAR-I, II, III). Data were pooled in a meta-analysis of up to 2 years of follow-up postimplantation. The main outcome measures were mean relative and absolute reduction in diurnal intraocular pressure (IOP) compared to baseline. Secondary outcomes included patients with IOP ≤18 mmHg, patients with IOP reduction ≥20%, number of IOP-lowering medications, adverse events, and endothelial cell density loss. RESULTS: At the 2-year follow-up (n = 66), mean IOP was reduced from 23.8 ± 3.3 mmHg at baseline to 14.4 ± 4.5 mmHg (-39.3%; P < 0.0001). An IOP reduction of ≥20% was achieved in 89.4% of patients, with 84.8% having an IOP ≤18 mmHg. IOP-lowering medications were reduced from a mean of 2.4 ± 1.1 to 1.4 ± 1.4 (P < 0.0001), with 37.9% of patients being medication-free at 2 years. Mean endothelial cell density loss at 2 years was 6.2 ± 9.1% compared to baseline and no patient had a loss >30%. CONCLUSIONS: This meta-analysis demonstrates the favorable safety and efficacy profile of a supraciliary device implanted in a stand-alone, ab-interno procedure in patients with mild-to-moderate POAG. The data demonstrate that MINIject is a safe and effective, bleb-free treatment option for patients requiring low target IOP up to 2 years.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Humanos , Estudos Prospectivos , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma de Ângulo Aberto/tratamento farmacológico , Pressão Intraocular , Tonometria Ocular , Resultado do Tratamento , Estudos Multicêntricos como Assunto
4.
Asia Pac J Ophthalmol (Phila) ; 12(6): 537-564, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38079242

RESUMO

The development of minimally invasive glaucoma surgeries (MIGSs) was intended to provide safe and modestly efficacious modalities for early intervention of mild-to-moderate glaucoma, with minimal trauma and rapid recovery. They were mainly ab interno procedures that reduce intraocular pressure by facilitating the aqueous outflow by bypassing the trabecular meshwork resistance, reinforcing the uveoscleral flow via the supraciliary space, and reducing aqueous production by the ciliary body. While the cumulating evidence helps shape the role of the available MIGS, the exponential new development and advancement in this field has expanded the territory of MIGS. Apart from developing subconjunctival MIGS filtration devices (Xen gel stent and PRESERFLO MicroShunt), there is a tendency to revisit the "traditional" MIGS for alternative use and to modify the procedures with consideration of the fundamental aqueous outflow physiology. Combined MIGS has also been suggested, based on the theory that their different mechanisms may provide additive or synergistic effects. The advancement of laser procedures is also promising and could supplement unmet needs along the glaucoma treatment algorithm. This review examines the broad array of MIGS, updates the recent findings, discusses their potential alternative applications, and explores future challenges.


Assuntos
Cirurgia Filtrante , Implantes para Drenagem de Glaucoma , Glaucoma , Humanos , Glaucoma/cirurgia , Pressão Intraocular , Cirurgia Filtrante/métodos , Tonometria Ocular
5.
J Glaucoma ; 32(11): 909-917, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37725786

RESUMO

PRCIS: XEN 45 Gel Stent is safe and effective for 3 years. The study results provide useful insight into the outcome of XEN 45 Gel Stent surgery over 5 years in daily clinical practice. PURPOSE: To evaluate 5-year outcomes of XEN 45 gel stent implantation (XEN) in patients with open angle glaucoma. METHODS: This is a prospective, single-center, interventional study. XEN implantation either alone (XEN) or combined with phacoemulsification (Phaco + XEN) was performed on 170 consecutive eyes (126 patients) with uncontrolled intraocular pressure (IOP) or disease progression despite medical treatment. "Complete" surgical success at 60 months was defined as unmedicated IOP ≤15 mm Hg and a relative IOP reduction ≥20% from medicated baseline, while "qualified" success allowed fewer ocular hypotensive medications than at baseline. Other definitions of success with various IOP targets were also analyzed. Secondary outcomes included mean IOP and IOP-lowering medication changes and rates of reoperations. RESULTS: Mean age was 78.1±9.2 years, and 70.3% were female. Mean medicated IOP decreased from 19.8±7.7 mm Hg [19.6±7.1 (XEN) vs. 19.8±7.0 mm Hg (Phaco+XEN)] at baseline to 12.6±3.1 mm Hg [12.5± 3.1 (XEN) vs. 12.6±3.1 (Phaco+XEN)] at 5 years (-37.0%; P < 0.001). Medications decreased from 2.0±1.3 [2.0±1.3 (XEN) vs. 2.0±1.3 (Phaco+XEN)] to 0.8±1.1 [0.8±1.1 (XEN) vs. 0.8±1.1 (Phaco + XEN)] (-60%; P <0.001). Needling was performed in 84 eyes (49%), and 19.4% underwent a secondary surgical intervention. Complete success at 3 years was a strong predictor of success at 5 years (odds ratio: 3.06, P <0.01), while needling was associated with higher rates of failure (odds ratio: 3.6, P <0.01). CONCLUSIONS: At 5 years, XEN gel stent implantation was a safe procedure and achieved clinically meaningful IOP and medication reduction. Success at 3 years is a predictor of success at 5 years. Needling correlates with higher failure rates.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma de Ângulo Aberto/etiologia , Estudos Prospectivos , Pressão Intraocular , Implantes para Drenagem de Glaucoma/efeitos adversos , Resultado do Tratamento , Stents/efeitos adversos , Estudos Retrospectivos
6.
Eye (Lond) ; 37(8): 1608-1613, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35945340

RESUMO

OBJECTIVES: To describe the efficacy and safety of goniotomy with trabecular meshwork excision using the Kahook Dual Blade (KDB, New World Medical Inc., Rancho Cucamonga, CA) in patients with severe or refractory glaucoma. METHODS: This retrospective multicentre case series reports on 40 eyes with severe or refractory open-angle glaucoma that underwent standalone or combined KDB goniotomy and were followed for 12 months post-operatively in the United-States, Mexico and Switzerland. Surgical success was defined as an intraocular pressure (IOP) reduction ≥20% from baseline at 12 months, with fewer medications than preoperatively. Mean IOP and antiglaucoma medication reduction, probabilities of achieving an IOP ≤16 or 18 mmHg, and adverse events were also analysed. RESULTS: Mean IOP decreased from 18.1 ± 5.0 mmHg at baseline to 14.8 ± 3.7 mmHg at 12 months (18.2% reduction, P < 0.001). Concomitantly, the mean number of glaucoma medications decreased from 2.5 ± 1.4 to 1.7 ± 1.2 (32% reduction, P = 0.002). The proportion of eyes achieving an IOP reduction of more than 20% from baseline was 37.5% (n = 15) at 12 months. At 12 months, 67.5% and 82.5% achieved a medicated IOP ≤ 16 and ≤18 mmHg, respectively. No severe complications were reported. CONCLUSION: Excisional goniotomy with KDB achieves a statistically significant IOP and antiglaucoma medication reduction in severe or refractory glaucoma over a period of 12 months. While its efficacy decreases with time, its favourable safety profile makes it a potentially useful primary or adjunctive procedure in high-risk eyes.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Hipotensão Ocular , Trabeculectomia , Humanos , Trabeculectomia/métodos , Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular , Agentes Antiglaucoma , Tonometria Ocular , Resultado do Tratamento , Glaucoma/cirurgia , Glaucoma/etiologia , Hipotensão Ocular/etiologia , Estudos Retrospectivos
7.
Ophthalmology ; 130(3): 304-312, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36202141

RESUMO

PURPOSE: Measuring and controlling intraocular pressure (IOP) provide the foundation for glaucoma treatment. Self-tonometry has been proposed as an alternative to measure IOP throughout the entire day better. The novel EYEMATE-SC sensor (Implandata) is implanted in the suprachoroidal space to enable contactless continual IOP monitoring. The aim of the present study was to investigate the 1-year safety, performance, and accuracy of the EYEMATE-SC in patients with primary open-angle glaucoma undergoing simultaneous nonpenetrating glaucoma surgery (NPGS). DESIGN: Prospective, multicenter, open-label, single-arm, interventional clinical trial. PARTICIPANTS: Twenty-four eyes of 24 patients with primary open-angle glaucoma who were due to undergo NPGS (canaloplasty or deep sclerectomy). METHODS: An EYEMATE-SC sensor was implanted during NPGS. Goldmann applanation tonometry (GAT) measurements were compared with the sensors' IOP measurements at all postoperative visits through 12 months. MAIN OUTCOME MEASURES: Device position and adverse events. RESULTS: Fifteen eyes underwent canaloplasty, and 9 underwent deep sclerectomy. Successful implantation of the sensor was achieved in all eyes with no reported intraoperative difficulties. Through the 12-month follow-up, no device migration, dislocation, or serious device-related complications were recorded. A total of 536 EYEMATE-SC measurements were pairwise included in the IOP agreement analysis. The overall mean difference between GAT and EYEMATE-SC measurements was 0.8 mmHg (95% confidence interval [CI] of the limits of agreement [LoA], -5.1 to 6.7 mmHg). The agreement gradually improved, and from 3 months after surgery until the end of the follow-up, the mean difference was -0.2 mmHg (95% CI of LoA, -4.6 to 4.2 mmHg) over a total of 264 EYEMATE-SC measurements, and 100% of measurements were within ±5 mmHg of GAT. CONCLUSIONS: The EYEMATE-SC sensor was safe and well tolerated through 12 months. Moreover, it allowed accurate, continuous IOP monitoring. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.


Assuntos
Glaucoma de Ângulo Aberto , Pressão Intraocular , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Tonometria Ocular
8.
Br J Ophthalmol ; 107(7): 941-945, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35443998

RESUMO

PURPOSE: To evaluate long-term intraocular temperature (IOT) variations in eyes with primary open-angle glaucoma (POAG) using an intraocular telemetric sensor. METHODS: This prospective, open-label, multicentre observational study analysed the IOT variations in 22 eyes of 22 patients with POAG. All enrolled patients underwent implantation of an intraocular pressure (IOP) sensor during cataract surgery. The telemetric system uses a built-in temperature sensor to control measured IOP for temperature. Each time a patient measures their IOP, both the IOP and IOT are recorded in the reader device. Patients were instructed to self-measure their IOP as often as desired, but at least four times daily. Recorded readings were retrieved and analysed using mixed effect models and pairwise comparisons using Bonferroni correction to assess the statistical significance of average IOT variations between each individual weekday and calendar month. RESULTS: The mean age of patients was 67.8±6.8 years and 36.4% were women. A total of 132 745 readings over 21 102 measurement-days were obtained. On average, IOT was significantly higher on Sundays (34.57°C; 95% CI 34.37 to 34.78) than on any other day of the week (p<0.001). Mean IOT on other weekdays ranged from 34.48°C to 34.51°C. Over the year, IOT followed a clear seasonal pattern, reaching its maximum in July (34.8°C; 95% CI 34.56 to 34.97) and its minimum in January (34.4°C; 95% CI 34.15 to 34.56; p<0.001). CONCLUSIONS: This study demonstrates the feasibility of continual and long-term measurement of IOT using intraocular sensors. The results show significant short-term and long-term fluctuations of IOT. Research is warranted to understand the impact of IOT variations on IOP, ocular perfusion and glaucoma progression.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Glaucoma de Ângulo Aberto/diagnóstico , Estudos Prospectivos , Estações do Ano , Temperatura , Pressão Intraocular , Tonometria Ocular
9.
Br J Ophthalmol ; 107(4): 518-524, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-34772665

RESUMO

AIM: To investigate the safety and performance of a telemetric suprachoroidal intraocular pressure (IOP) sensor (EYEMATE-SC) and the accuracy of its IOP measurements in open angle glaucoma (OAG) patients undergoing simultaneous non-penetrating glaucoma surgery (NPGS). METHODS: Prospective, multicentre, open-label, single-arm, interventional clinical trial. Twenty-four eyes of 24 patients with OAG regularly scheduled for NPGS (canaloplasty or deep sclerectomy) were simultaneously implanted with an EYEMATE-SC sensor. Six-month follow-up on the sensor's safety and performance as well as on the level of agreement between the EYEMATE-SC measurements and IOP measurements with Goldmann applanation tonometry (GAT). RESULTS: The eyes underwent canaloplasty (n=15) or deep sclerectomy (n=9) and achieved successful implantation of the sensor. No device migration, dislocation or serious device-related complications occurred. A total of 367 comparisons were included in the IOP agreement analysis. The overall mean difference between GAT and EYEMATE-SC measurements was 1.31 mm Hg (lower limit of agreement (LoA) 7.55 mm Hg; upper LoA -4.92 mm Hg). The maximum difference of 2.5 mm Hg ±3.96 (LoA 0.30-2.29) was reached on day 10 and continuously improved to an agreement of -0.15 mm Hg ±2.28 (LoA -1.24 to 0.89) after 6 months. Accordingly, the percentage of eyes within an IOP difference of ±5 mm Hg improved from 78% (day 3) to 100% (6 months). CONCLUSIONS: After 6 months, the EYEMATE-SC sensor was safe and well tolerated, and allowed continual IOP monitoring. TRIAL REGISTRATION NUMBER: NCT03756662.


Assuntos
Glaucoma de Ângulo Aberto , Pressão Intraocular , Humanos , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/cirurgia , Estudos Prospectivos , Tonometria Ocular
10.
Br J Ophthalmol ; 107(10): 1425-1431, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-35701079

RESUMO

BACKGROUND: Patients with glaucoma on topical glaucoma medication are often affected by dry eye symptoms and thus likely to rub or squeeze their eyelids. Here, we telemetrically measure peak intraocular pressure (IOP) during eyelid manoeuvres and eyelid rubbing. METHODS: Eleven patients with primary open-angle glaucoma (POAG) previously implanted with a telemetric IOP sensor (Eyemate-IO) were instructed to look straight ahead for 1 min as a baseline measurement. Next, 6 repeats of blinking on instruction with 10 s intervals in between were performed. In addition, 5 repeats of eyelid closure (n=9), eyelid squeezing and eyelid rubbing (n=7) were performed with 15 s intervals in between. IOP was recorded via an external antenna placed around the study eye. Average peak IOP increases from baseline were analysed and tested against zero (no change) with one-sample t-tests. RESULTS: For eyelid rubbing, the average peak ∆ IOP increase (mean±SEM) was 59.1±9.6 mm Hg (p<0.001) from baseline. It was 42.2±5.8 mm Hg (p<0.0001) for eyelid squeezing, 3.8±0.6 mm Hg (n=9, p<0.01) for eyelid closure and 11.6±2.4 mm Hg (p<0.001) for voluntary blinking. No IOP change except for a short irregularity in the ocular pulse was observed during involuntary blinking. CONCLUSION: Eyelid manoeuvres in patients with POAG elicited brief increases in IOP that were particularly large with squeezing and rubbing. Further investigation of the potential implications for glaucoma progression is warranted.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Humanos , Pressão Intraocular , Glaucoma de Ângulo Aberto/diagnóstico , Tonometria Ocular , Glaucoma/diagnóstico , Pálpebras , Músculos Oculomotores
11.
J Clin Med ; 11(16)2022 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-36013021

RESUMO

Background: The purpose of this study is to evaluate the outcome of deep sclerectomy (DS) as a secondary procedure following failed ab-interno XEN gel stent implantation in patients with open-angle glaucoma. Methods: Prospective, single-center, non-randomized, interventional study. Consecutive eyes that underwent mitomycin C (MMC) augmented XEN gel stent surgery, with uncontrolled intraocular pressure (IOP) or signs of disease progression, were included to undergo MMC-augmented DS. Primary efficacy outcome was surgical success, defined as complete when the unmedicated IOP was 12 mmHg or less, or 15 mmHg or less and 20% lower than at the timing of XEN failure and defined as qualified when the IOP fulfilled the same conditions with fewer medications than before deep sclerectomy. Secondary measures were mean reduction in IOP and in the number of medications, and the rates of complications. Results: Seventeen eyes were enrolled with a mean age of 72.1 ± 8.2 years (66.7% women). The mean follow-up was 20.1 ± 4.9 months, with more than 12-month data available from 15 eyes. Following DS, IOP decreased significantly from 22.6 ± 5.3 mmHg to 12.3 ± 5.5 (45.6%; p < 0.001). Antiglaucoma medications dropped from 1.1 ± 0.9 to 0.3 ± 0.7. Complete success was obtained in 40% of eyes using the threshold of 12 mmHg or less and a 20% decrease of IOP, and in 60% using the 15 mmHg or less threshold. Adverse events were observed in 20% of eyes (bleb leakage (13.3%); hypotony (6.7%)). No cases of choroidal detachment or hypotony maculopathy were reported. Conclusions: Failed XEN gel stent implantation does not seem to negatively affect the safety and efficacy of subsequent deep sclerectomy surgery.

12.
J Clin Med ; 11(12)2022 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-35743517

RESUMO

Glaucoma has a significant impact on quality of life. Here, we aimed to evaluate the influence of a reduction in glaucoma medications on quality of life and patient satisfaction after phacoemulsification combined with the Xen gel stent. We carried out a cross-sectional survey of patients who underwent phacoemulsification with the Xen gel stent at the Medical University of Graz, Austria. Quality of life was assessed using the German version of the Glaucoma Symptoms Scale (GSS)-questionnaire. Patients were also asked whether the operation reduced glaucoma medications and to indicate their overall satisfaction from 1 (totally discontented) up to 10 (totally contented). Questionnaires of 80 patients were evaluated. A total of 36 patients (45.0%) reported a reduction in glaucoma medications. Three items of the GSS were significantly better in patients who needed fewer glaucoma medications after the operation ("hard to see in daylight", 75.0 ± 31.1 vs. 57.7 ± 39.1, p = 0.035; "hard to see in dark places", 81.1 ± 28.7 vs. 54.9 ± 41.2, p = 0.002; and "halos around lights", 88.3 ± 25.9 vs. 68.8 ± 38.6, p = 0.002). Patient satisfaction was significantly higher when the procedure led to a reduction in glaucoma medication (8.3 ± 2.0 vs. 6.8 ± 3.1; p = 0.034). The reported quality of life and patient satisfaction were significantly better when phacoemulsification with the Xen gel stent reduced the number of glaucoma medications needed.

13.
Am J Ophthalmol ; 233: 171-179, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34320375

RESUMO

PURPOSE: To evaluate the association between optical microangiography (OMAG) measurements and progressive retinal nerve fiber layer (RNFL) loss in primary open angle glaucoma (POAG). DESIGN: Prospective case series. METHODS: Sixty-four eyes of 40 patients with POAG (108 quadrants) with mild to moderate functional damage were longitudinally studied for at least 2 years and with a minimum of 3 optical coherence tomography examinations. OMAG imaging was performed at the baseline visit. Effect of clinical parameters (age, sex, presence of systemic diseases, central corneal thickness, presence of disc hemorrhage, and mean and fluctuation of intraocular pressure during follow-up), baseline hemifield mean deviation, baseline quadrant optical coherence tomography RNFL and ganglion cell inner plexiform layer thickness), and OMAG (peripapillary and macular perfusion density [PD] and vessel density [VD]) on the rate of RNFL change was evaluated using linear mixed models. RESULTS: Average (±SD) mean deviation, RNFL, and ganglion cell inner plexiform layer thickness of the analyzed quadrants at baseline were -5.5 ± 2.9 dB, 96.5 ± 17.9 µm, and 73.8 ± 8.6 µm, respectively. Peripapillary PD and VD in the quadrant were 44.6% ± 5.9% and 17.5 ± 2.2 mm/mm2, respectively. Rate of quadrant RNFL change was -1.8 ± 0.6 µm/y. Multivariate mixed models showed that lower peripapillary PD (coefficient = 0.08, P = .01) and lower VD (coefficient = 0.21, P = .02) were significantly associated with a faster rate of RNFL loss. CONCLUSIONS: Lower baseline peripapillary PD and VD measured using OMAG were significantly associated with a faster rate of RNFL loss in POAG. OMAG imaging provides useful information about the risk of glaucoma progression and the rate of disease worsening.


Assuntos
Glaucoma de Ângulo Aberto , Disco Óptico , Glaucoma de Ângulo Aberto/diagnóstico , Humanos , Pressão Intraocular , Fibras Nervosas , Células Ganglionares da Retina , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica
14.
J Glaucoma ; 31(2): 109-115, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34086609

RESUMO

BACKGROUND/AIM: The aim of this study was to assess the difference in outcome between the first-operated and the second-operated eyes after nonpenetrating deep sclerectomy (DS), and to identify potential success predictors for the second eye. METHODS: This single-surgeon, retrospective study analyzed the outcomes of all bilateral nonsimultaneous DS with at least 24 months of follow-up. Its main outcome measure was surgical success, defined as unmedicated intraocular pressure (IOP) ≤15 mm Hg associated with a relative reduction ≥20%. RESULTS: In all, 104 eyes of 52 patients who underwent bilateral (standalone or combined) DS, within a mean of 344.3±526.3 days of each other, were analyzed. Postoperatively, the mean medicated IOP decreased from 20.7±7.9 (first-operated eyes) and 19.3±6.6 mm Hg (second-operated eyes) at baseline (P=0.107) to 13.8±4.8 [(-33.3%; P<0.001) first-operated eyes) and 12.7±3.8 mm Hg [(-34.2%; P<0.001) second-operated eyes] after 2 years (P=0.619). Postoperative IOP and treatment reduction, respectively, showed fair (r=0.53) and good (r=0.71) levels of correlation between fellow eyes. The rates of complete success were comparable between first-operated and second-operated eyes (32.7% and 40.4%, respectively; P=0.364). At 2 years, among patients whose first-operated eyes were considered a success, 82.4% of surgeries in second eyes were successful (P=0.001). The odds ratio of a second-operated eye experiencing complete success were 6.32 (P=0.011) if the first-operated eye experienced complete success. CONCLUSIONS: The present study demonstrated a strong association between first-operated and second-operated eyes after DS, in terms of surgical outcomes and IOP reduction. In effect, surgical success in the first-operated eye increases the odds of success in the second eye by 6-fold.


Assuntos
Glaucoma de Ângulo Aberto , Esclerostomia , Seguimentos , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Pressão Intraocular , Estudos Retrospectivos , Resultado do Tratamento
15.
Acta Ophthalmol ; 100(2): 203-211, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33629531

RESUMO

OBJECTIVES: To determine the effect of laser trabeculoplasty on peripapillary retinal nerve fibre layer thickness (RNFL), fovea avascular zone (FAZ), peripapillary and macular vessel density (VD) in glaucoma using with optical coherence tomography angiography (OCT-A). METHODS: This was a prospective observational study performed at the Glaucoma Research Centre, Montchoisi Clinic, Lausanne, Switzerland. Thirty-seven eyes with primary open-angle glaucoma from 21 patients were included. Optical coherence tomography angiography (OCT-A) scans were performed before laser trabeculoplasty and at 2 and 6 months after the procedure. AngioVue AngioAnalytic (Optovue Inc, Fremont, CA, USA) software was used to analyse the RNFL, FAZ, peripapillary and macular VD. Changes were analysed using mixed models, controlling for intraocular pressure (IOP) and signal strength index (SSI) variations. RESULTS: Mean IOP decreased from 18.5 (±3.7) mmHg at baseline to 15.6 (±2.7) mmHg after 2 months (-15.3%; p < 0.001). No significant changes in RNFL thickness were noted following laser trabeculoplasty. Changes in peripapillary VD were mostly nonsignificant. Parafoveal (p = 0.001) and perifoveal VD (p = 0.025) significantly increased at 2 months, before reverting to near-baseline values at 6 months. No significant changes were observed in foveal parameters. Retinal nerve fibre layer thickness (RNFL) and VD changes were independent from IOP, but SSI had a significant influence on VD. CONCLUSIONS: Following laser trabeculoplasty, peripapillary and macular VD temporarily increased before returning to near-baseline values by 6 months. No correlation was found between microvascular fluctuations and IOP, and no significant effect of laser trabeculoplasty on VD or RNFL was observed at 6 months despite persistent IOP reduction. Further research is warranted to understand its exact causes and clinical relevance.


Assuntos
Glaucoma de Ângulo Aberto/cirurgia , Trabeculectomia/instrumentação , Idoso , Angiografia por Tomografia Computadorizada , Feminino , Fóvea Central/irrigação sanguínea , Fóvea Central/patologia , Glaucoma de Ângulo Aberto/diagnóstico por imagem , Humanos , Pressão Intraocular , Lasers de Estado Sólido , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
16.
Am J Ophthalmol ; 238: 36-44, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34902324

RESUMO

PURPOSE: To evaluate the association between optical microangiography (OMAG) measurements and progressive ganglion cell-inner plexiform layer (GCIPL) loss in patients with primary open-angle glaucoma (POAG). DESIGN: Prospective case series. METHODS: Sixty-three eyes of 38 patients with POAG were studied for ≥2 years and with ≥ 3 optical coherence tomography examinations. Only those hemifields with mild to moderate functional damage at baseline (106 hemifields) were included in the analysis. OMAG imaging was performed at the baseline visit. The effects of clinical parameters (age, gender, central corneal thickness, presence of disc hemorrhage, and mean and fluctuation of intraocular pressure), baseline mean deviation, retinal nerve fiber layer, and GCIPL thickness and baseline OMAG measurements (peripapillary and macular perfusion density [PD] and vessel density [VD]) on the rate of change of GCIPL thickness were evaluated using linear mixed models. RESULTS: Average (± standard deviation) mean deviation, quadrant retinal nerve fiber layer, and sector GCIPL thickness of the analyzed hemifields respectively at baseline were -5.2 ± 2.8 dB, 94.5 ± 20.0 µm, and 72.4 ± 8.7 µm, respectively. Peripapillary PD and VD in the quadrant were 43.1% ± 7.0% and 17.0 ± 2.6 mm/mm2, respectively. Macular PD and VD in the quadrant were 37.2% ± 6.9% and 15.1 ± 2.6 mm/mm2, respectively. Rate of sector GCIPL change was -0.97 ± 0.15 µm per year. Multivariate mixed models showed that lower peripapillary PD (coefficient 0.04, P = .01) and VD (coefficient 0.09, P = .05) were significantly associated with a faster rate of GCIPL loss. CONCLUSIONS: Lower baseline peripapillary OMAG measurements were significantly associated with a faster rate of GCIPL loss in patients with mild to moderate POAG.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma de Ângulo Aberto/diagnóstico , Humanos , Pressão Intraocular , Fibras Nervosas , Células Ganglionares da Retina , Tomografia de Coerência Óptica/métodos
17.
J Glaucoma ; 30(10): 941-946, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34319931

RESUMO

PURPOSE: Intraocular pressure (IOP) is the only modifiable risk factor for glaucoma, with evidence from landmark randomized controlled trials demonstrating visual field preservation with IOP reduction. Over recent years, the use of remote sensors has formed an increasingly important component of the management of chronic diseases. During the coronavirus disease 2019 pandemic, the ability to remotely monitor IOP proved particularly useful when public stay at home orders have been in place. PATIENTS AND METHODS: This report describes the first case of glaucoma surgery in a patient who had previously received an EYEMATE-IO implant. The EYEMATE-IO is an implant for IOP monitoring placed in the ciliary sulcus during cataract surgery. RESULTS: Remote IOP monitoring enabled the clinician to identify sustained high IOP readings and the need for glaucoma surgery. Postoperatively, response to treatment could be monitored to ensure sufficient long-term IOP control. CONCLUSION: The EYEMATE-IO implanted during cataract surgery in this patient provided valuable remote continuous IOP information that guided timely glaucoma surgical interventions for poorly controlled IOP.


Assuntos
Glaucoma , Pressão Intraocular , COVID-19 , Extração de Catarata , Glaucoma/cirurgia , Humanos , SARS-CoV-2
18.
Invest Ophthalmol Vis Sci ; 62(6): 8, 2021 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-33956052

RESUMO

Purpose: To explore the effect of gaze direction and eyelid closure on intraocular pressure (IOP). Methods: Eleven patients with primary open-angle glaucoma previously implanted with a telemetric IOP sensor were instructed to view eight equally-spaced fixation targets each at three eccentricities (10°, 20°, and 25°). Nine patients also performed eyelid closure. IOP was recorded via an external antenna placed around the study eye. Differences of mean IOP between consecutive gaze positions were calculated. Furthermore, the effect of eyelid closure on gaze-dependent IOP was assessed. Results: The maximum IOP increase was observed at 25° superior gaze (mean ± SD: 4.4 ± 4.9 mm Hg) and maximum decrease at 25° inferonasal gaze (-1.6 ± 0.8 mm Hg). There was a significant interaction between gaze direction and eccentricity (P = 0.003). Post-hoc tests confirmed significant decreases inferonasally for all eccentricities (mean ± SEM: 10°: -0.7 ± 0.2, P = 0.007; 20°: -1.1 ± 0.2, P = 0.006; and 25°: -1.6 ± 0.2, P = 0.006). Eight of 11 eyes showed significant IOP differences between superior and inferonasal gaze at 25°. IOP decreased during eyelid closure, which was significantly lower than downgaze at 25° (mean ± SEM: -2.1 ± 0.3 mm Hg vs. -0.7 ± 0.2 mm Hg, P = 0.014). Conclusions: Our data suggest that IOP varies reproducibly with gaze direction, albeit with patient variability. IOP generally increased in upgaze but decreased in inferonasal gaze and on eyelid closure. Future studies should investigate the patient variability and IOP dynamics.


Assuntos
Técnicas Biossensoriais/instrumentação , Pálpebras/fisiologia , Fixação Ocular/fisiologia , Glaucoma de Ângulo Aberto/diagnóstico , Pressão Intraocular/fisiologia , Telemetria/métodos , Tonometria Ocular/instrumentação , Idoso , Eletrodos Implantados , Desenho de Equipamento , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
19.
J Glaucoma ; 30(8): e360-e363, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33979110

RESUMO

PURPOSE: Intravitreal injections (IVIs) may create transient intraocular pressure (IOP) elevation. This report describes continuous IOP fluctuations following multiple IVI measured with a permanent implantable sensor. PATIENTS AND METHODS: We report the case of a 49-year-old white glaucomatous male with refractory macular edema secondary to central retinal vein occlusion in his left eye who underwent deep sclerectomy combined with the implantation of a suprachoroidal tonometry sensor. Serial IOP measurements were performed immediately before and after each IVI over a 1-year period. RESULTS: During the first 7 months following deep sclerectomy, IOP remained below 10 mm Hg. During this period, mean IOP before each injection was 2.1±2.6 mm Hg, and each IVI caused a reduction of 1.2±0.8 mm Hg on average, with a maximum reduction of 2.7 mm Hg, before IOP normalized within 50 minutes to 24 hours. From 7 months postoperatively, mean IOP increased to the low teens. During this period, mean IOP before each injection was 9.9±1.8 mm Hg, and each IVI caused an increase of 15.8±11.7 mm Hg on average, with a maximum increase of 44.8 mm Hg, before IOP normalized within 20 minutes to 4 hours. CONCLUSIONS: During the initial postoperative phase, IVI may cause acute reduction in IOP, either through subconjunctival leaks or increased filtration secondary to increased fluid pressure. Several months after surgery, this effect subsides and IOP spikes sharply immediately after each IVI, suggesting the resolution of the initial mechanism, most likely through scarring and fibrosis.