1.
Appl Radiat Isot ; 204: 111121, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38016259

RESUMO

SPES (Selective Production of Exotic Species) is a second generation facility for the production of radioactive ion beams that is going to be commissioned at the Laboratori Nazionali di Legnaro of INFN at Legnaro, Padua, Italy. Radioactive neutron-rich isotopes are expected to be produced by nuclear fission induced by a 40 MeV, 200 µA primary proton beam impinging on a 238UCx target. The expected reaction rate is about 1013 fission/s. Radioactive ion beams are produced using the isotope separation on-line technique. The production of such an amount of radioactive species raises radiological issues throughout the life cycle of the facility. A study of the radioactive contamination of the components of the radioactive ion beam line is performed with the FLUKA Monte Carlo simulation code, under realistic hypotheses for the produced isobaric beams. The present results complete previous studies focused on the radiological impact of the production target irradiation, the residual activation of the primary proton beam line and the radioactive contamination of the ion source complex. The overall ambient dose equivalent rate due to the different radiation sources is calculated at several positions inside the production bunker and at different times after a typical one-year operating period of the facility with the 238UCx target at full power. The obtained results and the developed methodology provide the guidelines and the needed tools to plan ordinary and extraordinary interventions as well as final decommissioning of the SPES facility.

2.
Rev Sci Instrum ; 93(8): 083001, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-36050098

RESUMO

The Selective Production of Exotic Species project is under construction at Laboratori Nazionali di Legnaro-INFN. The aim of the collaboration is to produce highly pure Radioactive Ion Beams (RIBs) from fission fragments of a uranium carbide (UCx) target activated by a cyclotron proton beam. In order to select a specific atomic species, the main tool to be applied is the resonant laser ionization technique. We have just completed the installation of a dedicated all solid state laser system whose elements are tunable to transitions of all the elements/isotopes of interest for the project. The new laser system is based on three Titanium:sapphire laser sources, independently pumped by three Nd:YLF pump lasers, and it can be coupled to two high harmonic generation (second harmonic generation, third harmonic generation, and fourth harmonic generation) setups. The power, wavelength, and position of the laser beams are continuously monitored and stabilized by using automated active systems to improve the beam production stability of RIBs. This paper presents the main features of the laser system and examples of application of a laser ion source, including a first demonstration of photoionization of stable silver, one of the most requested elements for RIB application.

3.
Rev Sci Instrum ; 92(5): 053304, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243328

RESUMO

The Isotope Separation On-Line (ISOL) technique is today established as one of the primary methods to produce high-intensity and high-quality radioactive beams. This technique produces, for a given amount of the desired isotope, many orders of magnitude of other radioactive species. Due to the activation generated by interactions of the primary beam, intense neutron fields, and deposition of the produced radioactive ions inside beam line elements, an ISOL facility in operation becomes an intense radioactive source. Therefore, the biological hazard imposes severe radiological safety challenges to the design, operation, maintenance, and final decommissioning of such facilities. A challenging component is the ion source complex, where the ion extraction electrode provides the extraction of radioactive ions from the ion source and the first acceleration to the extracted beam. The radioactive contamination of this sub-component is studied, by means of the FLUKA code, in the case of the Selective Production of Exotic Species facility, which is in the advanced construction phase at Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro, Padua, Italy. The developed model includes isotope production by the interactions of a 40 MeV energy proton beam on a 238UCx target, selection of radioactive isotopes that are able to stick on the electrode tip, time evolution of the deposited isotopes during the operation and cooling periods before maintenance interventions, and evaluation of the ambient dose equivalent rate generated by the contamination of the electrode tip. Based on these results, the possibility of manual interventions for maintenance and emergency vs the use of remote handling systems is discussed.

4.
Rev Sci Instrum ; 88(11): 113304, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29195412

RESUMO

Materials and components employed in the presence of intense neutron and gamma fields are expected to absorb high dose levels that may induce deep modifications of their physical and mechanical properties, possibly causing loss of their function. A protocol for irradiating elastomeric materials in reactor mixed neutron and gamma fields and for testing the evolution of their main mechanical and physical properties with absorbed dose has been developed. Four elastomeric compounds used for vacuum O-rings, one fluoroelastomer polymer (FPM) based and three ethylene propylene diene monomer rubber (EPDM) based, presently available on the market have been selected for the test. One EPDM is rated as radiation resistant in gamma fields, while the other elastomers are general purpose products. Particular care has been devoted to dosimetry calculations, since absorbed dose in neutron fields, unlike pure gamma fields, is strongly dependent on the material composition and, in particular, on the hydrogen content. The products have been tested up to about 2 MGy absorbed dose. The FPM based elastomer, in spite of its lower dose absorption in fast neutron fields, features the largest variations of properties, with a dramatic increase in stiffness and brittleness. Out of the three EPDM based compounds, one shows large and rapid changes in the main mechanical properties, whereas the other two feature more stable behaviors. The performance of the EPDM rated as radiation resistant in pure gamma fields does not appear significantly better than that of the standard product. The predictive capability of the accelerated irradiation tests performed as well as the applicable concepts of threshold of radiation damage is discussed in view of the use of the examined products in the selective production of exotic species facility, now under construction at the Legnaro National Laboratories of the Italian Istituto Nazionale di Fisica Nucleare. It results that a careful account of dose rate effects and oxygen penetration in the material, both during test irradiations and in operating conditions, is needed to obtain reliable predictions.

5.
Rev Sci Instrum ; 88(9): 093302, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28964234

RESUMO

Ion sources and target systems play a crucial role in isotope separation on line facilities, determining the main characteristics of the radioactive ion beams available for experiments. In the context of the selective production of exotic species (SPES) facility, a 40 MeV, 200 µA proton beam directly impinges a uranium carbide target, generating approximately 1013 fissions per second. The radioactive isotopes produced by the 238U fissions are delivered to the 1+ ion source by means of a tubular transfer line. Here they can be ionized and subsequently accelerated toward the experimental areas. In this work, the characterization of the surface ionization source currently adopted for the SPES facility is presented, taking as a reference ionization efficiency and transversal emittance measurements. The effects of long term operation at high temperature are also illustrated and discussed.

6.
Appl Radiat Isot ; 127: 214-226, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28649019

RESUMO

Radiopharmaceuticals represent a fundamental tool for nuclear medicine procedures, both for diagnostic and therapeutic purposes. The present work aims to explore the Isotope Separation On-Line (ISOL) technique for the production of carrier-free radionuclides for nuclear medicine at SPES, a nuclear physics facility under construction at INFN-LNL. Stable ion beams of strontium, yttrium and iodine were produced using the SPES test bench (Front-End) to simulate the production of 89Sr, 90Y, 125I and 131I and collected with good efficiency on suitable targets.


Assuntos
Radioisótopos/isolamento & purificação , Compostos Radiofarmacêuticos/isolamento & purificação , Simulação por Computador , Ciclotrons , Desenho de Equipamento , Estudos de Viabilidade , Humanos , Radioisótopos do Iodo/isolamento & purificação , Medicina Nuclear/métodos , Equipamentos e Provisões para Radiação , Cintilografia , Radioisótopos de Estrôncio/isolamento & purificação , Tecnologia Radiológica , Radioisótopos de Ítrio/isolamento & purificação
7.
Rev Sci Instrum ; 87(3): 033303, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27036768

RESUMO

The production target and the ion source constitute the core of the selective production of exotic species (SPES) facility. In this complex experimental apparatus for the production of radioactive ion beams, a 40 MeV, 200 µA proton beam directly impinges a uranium carbide target, generating approximately 10(13) fissions per second. The transfer line enables the unstable isotopes generated by the (238)U fissions in the target to reach the ion source, where they can be ionized and finally accelerated to the subsequent areas of the facility. In this work, the plasma ion source currently adopted for the SPES facility is analyzed in detail by means of electrical, thermal, and structural numerical models. Next, theoretical results are compared with the electric potential difference, temperature, and displacement measurements. Experimental tests with stable ion beams are also presented and discussed.

8.
Rev Sci Instrum ; 87(2): 02B502, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26932055

RESUMO

In isotope separation on line facilities the target system and the related ion source are two of the most critical components. In the context of the selective production of exotic species (SPES) project, a 40 MeV 200 µA proton beam directly impinges a uranium carbide target, generating approximately 10(13) fissions per second. The radioactive isotopes produced in this way are then directed to the ion source, where they can be ionized and finally accelerated to the subsequent areas of the facility. In this work both the surface ion source and the plasma ion source adopted for the SPES facility are presented and studied by means of numerical thermal-electric models. Then, numerical results are compared with temperature and electric potential difference measurements, and finally the main advantages of the proposed simulation approach are discussed.

9.
Rev Sci Instrum ; 85(2): 02A929, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593508

RESUMO

The ECR ion sources are able to produce a wide variety of highly charged metallic ion beams thanks to the development of different techniques (ovens, sputtering, direct insertion, metal ions from volatile compounds (MIVOC)). In the case of the ovens, the sticking of the hot vapors on the surface of the plasma chamber leads to high material consumption rates. For elements like Ca, a tantalum liner inserted inside the chamber can be used to limit this phenomenon. The modeling of temperature distribution inside the chamber with and without the liner was carried out with COMSOL-multiphysics code. Results of simulation and the comparison with experiments performed at INFN-Legnaro National Laboratories with Ca beams are discussed.

10.
Rev Sci Instrum ; 85(2): 02B905, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593610

RESUMO

SPES (Selective Production of Exotic Species) is an INFN (Istituto Nazionale di Fisica Nucleare) project with the aim at producing and post-accelerating exotic beams to perform forefront research in nuclear physics. To allow post-acceleration of the radioactive ions, an ECR-based Charge Breeder (CB) developed on the basis of the Phoenix booster was chosen. The design of the complete beam line for the SPES-CB will be described: a system for stable 1+ beams production was included; special attention was paid to the medium resolution mass spectrometer after the CB to limit possible superposition of the exotic beams with the impurities present in the ECR plasma.

11.
Rev Sci Instrum ; 85(2): 02B908, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593613

RESUMO

SPES (Selective Production of Exotic Species) is an Isotope Separation On-Line (ISOL) based accelerator facility that will be built in the Legnaro-Istituto Nazionale di Fisica Nucleare (INFN) Laboratory (Italy), intended to provide intense neutron-rich radioactive ion beams obtained by proton-induced fission of a uranium carbide (UCx) target. Besides this main target material, silicon carbide (SiC) will be the first to be used to deliver p-rich beams. This target will also validate the functionality of the SPES facility with aluminum beam as result of impinging SiC target with proton beam. In the past, off line studies on laser photoionization of aluminum have been performed in Pavia Spectroscopy Laboratory and in Laboratori Nazionali di Legnaro; a XeCl excimer laser was installed in order to test the laser ionization in the SPES hot cavity. With the new Wien filter installed a better characterization of the ionization process in terms of efficiency was performed and results are discussed.

12.
Rev Sci Instrum ; 85(2): 02B918, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593623

RESUMO

An intense research and development activity to finalize the design of the target ion source system for the selective production of exotic species (SPES) facility (operating according to the isotope separation on line technique) is at present ongoing at Legnaro National Laboratories. In particular, the characterization of ion sources in terms of ionization efficiency and transversal emittance is currently in progress, and a preliminary set of data is already available. In this work, the off-line ionization efficiency and emittance measurements for the SPES forced electron beam induced arc discharge ion source in the case of a stable Ar beam are presented in detail.

13.
Rev Sci Instrum ; 84(5): 054902, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23742578

RESUMO

A new methodology and an instrumental setup for the thermal conductivity estimation of isotropic bulk graphite and different carbides at high temperatures are presented. The method proposed in this work is based on the direct measurement of temperature and emissivity on the top surface of a sample disc of known dimensions. Temperatures measured under steady-state thermal equilibrium are then used to estimate the thermal conductivity of the sample by making use of the inverse parameter estimation technique. Thermal conductivity values obtained in this way are then compared to the material data sheets and values found in literature. The reported work has been developed within the Research and Development framework of the SPES (Selective Production of Exotic Species) project at INFN-LNL (Istituto Nazionale di Fisica Nucleare - Laboratori Nazionali di Legnaro).

14.
Rev Sci Instrum ; 83(2): 02A907, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380248

RESUMO

The development of new target ion source systems for the selective production of exotic species (SPES) facility is currently in progress at Legnaro National Laboratories. In this context, the study of ion sources and their performance in terms of ionization efficiency and transversal emittance is a crucial point in order to maximize the available yields, particularly for short-lived isotopes. In this work, preliminary off-line ionization efficiency and emittance measurements for the SPES surface and plasma ion sources are presented. The plasma source emittance measurements are supported by dedicated numerical calculations.

15.
Rev Sci Instrum ; 83(2): 02B317, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380296

RESUMO

Selective production of exotic species (SPES) is an ISOL-based accelerator facility that will be built in the Legnaro INFN Laboratory (Italy), intended to provide an intense neutron-rich radioactive ion beams obtained by proton induced fission of an uranium carbide target. Beside this main target, a silicon carbide (SiC) target will the first to be used to deliver some p-rich beams. This target will validate also the functionality of the SPES facility with aluminum beam as result of hitting SiC target with protons. In the past off-line studies on laser photoionization of aluminum have performed in Pavia Spectroscopy Laboratory and in Laboratori Nazionali di Legnaro where, recently, a XeCl excimer laser was installed in order to test the laser ionization in the SPES hot cavity. Results are promising to justify further studies with this technique, aiming a better characterization of the SPES ion extraction capability under laser photoionization.