Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cardiovasc Res ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38900927

RESUMO

AIMS: MicroRNA-126 (miR-126), one of the most abundant microRNAs in platelets, is involved in the regulation of platelet activity and the circulating miR-126 is reduced during antiplatelet therapy. However, whether intraplatelet miR-126 plays a role in thrombosis and platelet inhibition remains unclear. METHODS AND RESULTS: Here, using tissue-specific knockout mice, we reported that the deficiency of miR-126 in platelets and vascular endothelial cells significantly prevented thrombosis and prolonged bleeding time. Using chimeric mice, we identified that the lack of intraplatelet miR-126 significantly prevented thrombosis. Ex vivo experiments further demonstrated that miR-126-deficient platelets displayed impaired platelet aggregation, spreading and secretory functions. Next, miR-126 was confirmed to target phosphoinositol-3 kinase regulatory subunit 2 (PIK3R2) in platelet, which encodes a negative regulator of the PI3 K/AKT pathway, enhancing platelet activation through activating the integrin αIIbß3-mediated outside-in signaling. After undergoing myocardial infarction (MI), chimeric mice lacking intraplatelet miR-126 displayed reduced microvascular obstruction and prevented MI expansion in vivo. In contrast, overexpression of miR-126 by the administration of miR-126 agonist (agomiR-126) in wild-type mice aggravated microvascular obstruction and promoted MI expansion, which can be almost abolished by aspirin administration. In patients with cardiovascular diseases, antiplatelet therapies, either aspirin alone or combined with clopidogrel, decreased the level of intraplatelet miR-126. The reduction of intraplatelet miR-126 level was associated with the decrease of platelet activity. CONCLUSIONS: Our murine and human data reveal that (i) intraplatelet miR-126 contributes to platelet activity and promotes thrombus formation, and (ii) the reduction of intraplatelet miR-126 contributes to platelet inhibition during antiplatelet therapy.

3.
Environ Sci Pollut Res Int ; 27(10): 11246-11259, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31960244

RESUMO

Triclosan (TCS) is a broad-spectrum antimicrobial agent that is broadly used in personal care products. It has been shown to cause the contamination of a variety of aquatic environments. Since algae has been the primary producers of aquatic ecosystems, understanding the toxicological mechanisms and the metabolic fate of TCS is vital for assessing its risk in an aquatic environment. In our study, 0.5-4 mg L-1 TCS treatments for 72 h in a culture of Chlamydomonas reinhardtii (C. reinhardtii) showed progressive inhibition of cell growth and reduced the chlorophyll content. The EC50 value of C. reinhardtii after 72 h was 1.637 mg L-1, which showed its higher level of resistance to TCS in comparison with other algal species. The exposure to TCS led to oxidative injuries of algae in relation to the increment of malonaldehyde content, cell membrane permeability, and H2O2 levels. Furthermore, the oxidative stress from TCS stimulated a series of antioxidant enzyme activities and their gene expressions. Simultaneously, the accumulated TCS in C. reinhardtii arouses the detoxification/degradation-related enzymes and related gene transcriptions. In the medium, approximately 82% of TCS was removed by C. reinhardtii. Importantly, eight TCS metabolites were identified by ultra-performance liquid chromatography-high-resolution mass spectrometry and their relative abundances were measured in a time-course experiment. Six of these metabolites are reported here for the first time. The metabolic pathways of triclosan via C. reinhardtii including reductive dechlorination, hydroxylation, sulfhydrylation, and binding with thiol/cysteine/GSH/glycosyl were manifested to broaden our understanding of the environmental fate of TCS. Graphical Abstract.


Assuntos
Chlamydomonas reinhardtii , Triclosan/análise , Poluentes Químicos da Água/análise , Bioacumulação , Ecossistema , Peróxido de Hidrogênio
4.
Chemosphere ; 238: 124640, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31524609

RESUMO

Triclosan (TCS) is a kind of chronic toxicity to aquatic organisms. Due to its highly effective antimicrobial, TCS has been widely applied in personal-care products, which naturally poses a potential risk to the ecological system and human health since its release into water-ecological environment. Therefore, it urgently demands a selective, easily separated, recyclable, and low-cost adsorbent to remove the residues of TCS from aquatic environments. In this study, a novel magnetic molecularly imprinted nano-polymers (TMIPs) were prepared for selective adsorption and convenient collection of TCS in aquatic samples, based on a core-shell technique using TCS as template molecule and SiO2-coated Fe3O4 nanoparticles as the support substrate. The functional groups, particle size, morphology and magnetic property of TMIPs were characterized by Fourier-transform infrared spectroscopy, scanning electron microscope, transmission electron microscopy and vibrating sample magnetometer, respectively. The obtained TMIPs possessed excellent adsorption capacity (Qe = 53.12 mg g-1), speedy adsorption equilibrium time (2 min) and high selectivity (k' = 6.321) for TCS. Moreover, the pH-tolerance and stability tests manifested that the adsorption capacity of TMIPs for TCS was acid-resistance and could retain 94.2% of the maximum Qe after 5 times removal-regeneration cycles. The feature of magnetically susceptibility can simplify the procedures of sample handling in TCS determination, because the TMIPs of TCS are easy to be recycled from aquatic samples. As an application demonstration, the toxicity test in microalgae confirmed that a tiny amount of TMIPs could significantly eliminate the toxic effect of TCS on Chlamydomonas reinhardtii via the efficient binding with TCS.


Assuntos
Magnetismo/métodos , Impressão Molecular , Nanopartículas/química , Triclosan/isolamento & purificação , Poluentes Químicos da Água/isolamento & purificação , Adsorção , Antibacterianos/isolamento & purificação , Antibacterianos/toxicidade , Cosméticos/química , Cosméticos/toxicidade , Impressão Molecular/métodos , Tamanho da Partícula , Polímeros/química , Dióxido de Silício/química , Triclosan/toxicidade
5.
Ecotoxicol Environ Saf ; 177: 66-76, 2019 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-30974245

RESUMO

A novel magnetic MIPs (DUMIPs) was prepared by surface molecular imprinting method using superparamagnetic core-shell nanoparticle (Fe3O4@SiO2) as the sacrificial support matrix, herbicide diuron as template, α-methacrylic acid as the functional monomer, trimethylolpropane trimethacrylate as the crosslinker, azobisisobutyronitrile as the initiator, and acetonitrile as the porogen. Highly cross-linked porous surface and excellent magnetic property were characterized by Fourier-transform infrared spectroscopy, transmission electron microscopy, and vibrating sample magnetometer, respectively. The adsorption capacity of DUMIPs was 8.1 mg g-1, 2.6-fold over its corresponding non-imprinted polymers (DUNIPs). The adsorption in DUMIPs was considered as multilayer adsorption and posed high affinity to diuron, due to the better fitting to Freundilich isotherm. Competitive recognition study demonstrated DUMIPs had highly selective binding diuron. DUMIPs, as an influential sorbent has been used for selective extraction of diuron from environmental samples (paddy field water, paddy soil and grain seedlings) and the elution was determined by high efficiency liquid chromatography (HPLC). In this analytical method, various factors affecting the extraction efficiency such as pH, sorbent dosage, utilization efficiency and volumes of eluent were simultaneously investigated. Under the optimal conditions, the linearity of the method obtained is in the range of 0.02-10.0 mg L-1. The limit of detection is 0.012 mg L-1. In four spiked levels (0.04, 0.2, 1.0, and 4.0 mg kg-1), the recoveries of diuron in real samples are in the range of 83.56%-116.10% with relative standard deviations in the range of 1.21-6.81%. Importantly, compared to C18-SPE column, the MMIPs exhibited convenient separation by external magnetic field, strong clean-up capacity, and selective enrichment for diuron. Thus, the DUMIPs-based method is great potential for efficient sample preparation in the determination of trace amounts of diuron residues in complex matrices.


Assuntos
Diurona/análise , Herbicidas/análise , Impressão Molecular/métodos , Adsorção , Cromatografia Líquida de Alta Pressão/métodos , Diurona/química , Herbicidas/química , Magnetismo , Metacrilatos/química , Nanopartículas/química , Polímeros/química , Porosidade , Dióxido de Silício/química , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...