Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS Genet ; 15(5): e1008102, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-31095560

RESUMO

In flat-faced dog breeds, air resistance caused by skull conformation is believed to be a major determinant of Brachycephalic Obstructive Airway Syndrome (BOAS). The clinical presentation of BOAS is heterogeneous, suggesting determinants independent of skull conformation contribute to airway disease. Norwich Terriers, a mesocephalic breed, are predisposed to Upper Airway Syndrome (UAS), a disease whose pathological features overlap with BOAS. Our health screening clinic examined and scored the airways of 401 Norwich terriers by laryngoscopy. Genome-wide association analyses of UAS-related pathologies revealed a genetic association on canine chromosome 13 (rs9043975, p = 7.79x10-16). Whole genome resequencing was used to identify causal variant(s) within a 414 kb critical interval. This approach highlighted an error in the CanFam3.1 dog assembly, which when resolved, led to the discovery of a c.2786G>A missense variant in exon 20 of the positional candidate gene, ADAM metallopeptidase with thrombospondin type 1 motif 3 (ADAMTS3). In addition to segregating with UAS amongst Norwich Terriers, the ADAMTS3 c.2786G>A risk allele frequency was enriched among the BOAS-susceptible French and (English) Bulldogs. Previous studies indicate that ADAMTS3 loss of function results in lymphoedema. Our results suggest a new paradigm in the understanding of canine upper airway disease aetiology: airway oedema caused by disruption of ADAMTS3 predisposes dogs to respiratory obstruction. These findings will enhance breeding practices and could refine the prognostics of surgical interventions that are often used to treat airway obstruction.


Assuntos
Proteínas ADAMTS/genética , Doenças do Cão/genética , Mutação de Sentido Incorreto , Doença Pulmonar Obstrutiva Crônica/genética , Alelos , Animais , Cromossomos de Mamíferos/química , Suscetibilidade a Doenças , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/fisiopatologia , Cães , Feminino , Expressão Gênica , Frequência do Gene , Estudo de Associação Genômica Ampla , Laringoscopia , Masculino , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Sistema Respiratório/anatomia & histologia , Sistema Respiratório/diagnóstico por imagem , Sistema Respiratório/fisiopatologia , Crânio/anatomia & histologia , Sequenciamento Completo do Genoma
2.
Radiother Oncol ; 136: 64-70, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31015131

RESUMO

PURPOSE: Image guided radiotherapy (IGRT) based on respiration correlated cone-beam CT (4D-CBCT) provides accurate tumour localisation in lung cancer patients by taking into account respiratory motion when deriving setup correction. However, 4D-CBCT scan times are typically longer than for acquisition of 3D-CBCT scans, e.g. 4 min. This work aims to quantitatively evaluate the effect of reduced scan times on 4D-CBCT image quality and registration accuracy in lung cancer patients. METHODS AND MATERIALS: Scan times down to 1 min were simulated by retaining only projection images corresponding to every second, third or fourth respiratory cycle in forty-four 4D-CBCTs from 15 lung cancer patients. In addition twenty 2-minute scans were acquired for 12 lung cancer patients. Image quality was quantified by assessing registration accuracy in the shorter scan times, comparing to the 4-minute scan registration result where available as reference. RESULTS: Use of 2-minute scans had little impact on registration accuracy or ability to detect tumour motion: automatic registration accuracy was within 2 mm in 6/8 scans analysed with 2-minute acquisitions, and 96.6% of registration discrepancies were within 2 mm for the simulated scans. When the scan time simulated was below 2 min, automatic registration results still agreed within 2 mm for 84.7% of scans, however visual image quality was considerably degraded. CONCLUSION: A 4D-CBCT acquisition time of 2 min produces scans of sufficient image quality for IGRT in most lung cancer patients, as demonstrated quantitatively by assessing the impact on automatic registration accuracy in simulated and real acquisitions.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Simulação por Computador , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Neoplasias Pulmonares/fisiopatologia , Neoplasias Pulmonares/radioterapia , Cintilografia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Mecânica Respiratória , Estudos Retrospectivos
4.
Acta Oncol ; 57(9): 1240-1249, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29698060

RESUMO

PURPOSE: Conventional techniques (3D-CRT) for craniospinal irradiation (CSI) are still widely used. Modern techniques (IMRT, VMAT, TomoTherapy®, proton pencil beam scanning [PBS]) are applied in a limited number of centers. For a 14-year-old patient, we aimed to compare dose distributions of five CSI techniques applied across Europe and generated according to the participating institute protocols, therefore representing daily practice. MATERIAL AND METHODS: A multicenter (n = 15) dosimetric analysis of five different techniques for CSI (3D-CRT, IMRT, VMAT, TomoTherapy®, PBS; 3 centers per technique) was performed using the same patient data, set of delineations and dose prescription (36.0/1.8 Gy). Different treatment plans were optimized based on the same planning target volume margin. All participating institutes returned their best treatment plan applicable in clinic. RESULTS: The modern radiotherapy techniques investigated resulted in superior conformity/homogeneity-indices (CI/HI), particularly in the spinal part of the target (CI: 3D-CRT:0.3 vs. modern:0.6; HI: 3D-CRT:0.2 vs. modern:0.1), and demonstrated a decreased dose to the thyroid, heart, esophagus and pancreas. Dose reductions of >10.0 Gy were observed with PBS compared to modern photon techniques for parotid glands, thyroid and pancreas. Following this technique, a wide range in dosimetry among centers using the same technique was observed (e.g., thyroid mean dose: VMAT: 5.6-24.6 Gy; PBS: 0.3-10.1 Gy). CONCLUSIONS: The investigated modern radiotherapy techniques demonstrate superior dosimetric results compared to 3D-CRT. The lowest mean dose for organs at risk is obtained with proton therapy. However, for a large number of organs ranges in mean doses were wide and overlapping between techniques making it difficult to recommend one radiotherapy technique over another.


Assuntos
Radiação Cranioespinal/métodos , Padrões de Prática Médica/estatística & dados numéricos , Radioterapia (Especialidade) , Adolescente , Comitês Consultivos/organização & administração , Radiação Cranioespinal/estatística & dados numéricos , Europa (Continente)/epidemiologia , Humanos , Masculino , Órgãos em Risco/efeitos da radiação , Radioterapia (Especialidade)/métodos , Radioterapia (Especialidade)/organização & administração , Radiometria/métodos , Radiometria/normas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas
5.
J Feline Med Surg ; 20(8): 752-758, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-28925790

RESUMO

Objectives This study aimed to investigate differences and demonstrate a normal range of morphological variation of the caudal fossa of the cranium of domestic cats. Methods CT scans of 32 domestic cat heads of 11 breeds were included. Isosurfaces from skulls were characterised through three-dimensional geometric morphometrics using geographical landmarks placed on the internal surface of the caudal fossa and foramen magnum. Raw data was transformed with a Procrustes fit and coordinate covariance was analysed by principal components to establish breed- and sex-level differences. Skulls were also classified according to the number of concavities along the mid-sagittal vermiform impression. Differences were investigated between breed groups and sex, and correlation was sought with age. Results Analyses revealed size-independent differences in occipital bone morphology across breeds and sex; however, no clustering was evident. Most variability was observed at the exoccipital bones, ventral portion of the supraoccipital bone, dorsum sellae of the basisphenoid and the osseous tentorium cerebelli. No statistically significant differences were identified via two-sample t-tests between breed groups or sexes. No statistically significant correlation using Spearman rho correlation coefficient was identified with age. Conclusions and relevance The feline caudal fossa displays a wide range of intra- and inter-breed variation, not linked to age or sex. Concavities along the vermiform impression have not previously been described. As advanced imaging modalities are becoming more frequently used for domestic felids, an established range of normality is important for discriminating pathological changes from anatomical variances.


Assuntos
Gatos/anatomia & histologia , Crânio/anatomia & histologia , Crânio/diagnóstico por imagem , Animais , Feminino , Masculino , Tomografia Computadorizada por Raios X/veterinária
6.
Curr Biol ; 27(11): 1573-1584.e6, 2017 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-28552356

RESUMO

In morphological terms, "form" is used to describe an object's shape and size. In dogs, facial form is stunningly diverse. Facial retrusion, the proximodistal shortening of the snout and widening of the hard palate is common to brachycephalic dogs and is a welfare concern, as the incidence of respiratory distress and ocular trauma observed in this class of dogs is highly correlated with their skull form. Progress to identify the molecular underpinnings of facial retrusion is limited to association of a missense mutation in BMP3 among small brachycephalic dogs. Here, we used morphometrics of skull isosurfaces derived from 374 pedigree and mixed-breed dogs to dissect the genetics of skull form. Through deconvolution of facial forms, we identified quantitative trait loci that are responsible for canine facial shapes and sizes. Our novel insights include recognition that the FGF4 retrogene insertion, previously associated with appendicular chondrodysplasia, also reduces neurocranium size. Focusing on facial shape, we resolved a quantitative trait locus on canine chromosome 1 to a 188-kb critical interval that encompasses SMOC2. An intronic, transposable element within SMOC2 promotes the utilization of cryptic splice sites, causing its incorporation into transcripts, and drastically reduces SMOC2 gene expression in brachycephalic dogs. SMOC2 disruption affects the facial skeleton in a dose-dependent manner. The size effects of the associated SMOC2 haplotype are profound, accounting for 36% of facial length variation in the dogs we tested. Our data bring new focus to SMOC2 by highlighting its clinical implications in both human and veterinary medicine.


Assuntos
Proteínas de Ligação ao Cálcio/genética , Craniossinostoses/veterinária , Cães/genética , Splicing de RNA/genética , Retroelementos/genética , Pontos de Referência Anatômicos , Animais , Cruzamento/métodos , Craniossinostoses/diagnóstico por imagem , Craniossinostoses/genética , Face/anormalidades , Feminino , Fator 4 de Crescimento de Fibroblastos/genética , Estudo de Associação Genômica Ampla , Haplótipos/genética , Íntrons/genética , Masculino , Locos de Características Quantitativas/genética , Crânio/anormalidades , Crânio/diagnóstico por imagem , Suíça , Tomografia Computadorizada por Raios X , Reino Unido
7.
Phys Med Biol ; 62(15): 6092-6107, 2017 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-28557792

RESUMO

Reconstructive volumetric imaging permeates medical practice because of its apparently clear depiction of anatomy. However, the tell tale signs of abnormality and its delineation for treatment demand experts work at the threshold of visibility for hints of structure. Hitherto, a suitable assistive metric that chimes with clinical experience has been absent. This paper develops the complexity measure approximate entropy (ApEn) from its 1D physiological origin into a three-dimensional (3D) algorithm to fill this gap. The first 3D algorithm for this is presented in detail. Validation results for known test arrays are followed by a comparison of fan-beam and cone-beam x-ray computed tomography image volumes used in image guided radiotherapy for cancer. Results show the structural detail down to individual voxel level, the strength of which is calibrated by the ApEn process itself. The potential for application in machine assisted manual interaction and automated image processing and interrogation, including radiomics associated with predictive outcome modeling, is discussed.


Assuntos
Algoritmos , Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Neoplasias Pélvicas/diagnóstico por imagem , Calibragem , Entropia , Humanos , Neoplasias Pélvicas/radioterapia
8.
J Vis Exp ; (93): e52099, 2014 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-25490604

RESUMO

The late 1970s saw the first publicly reported use of the western blot, a technique for assessing the presence and relative abundance of specific proteins within complex biological samples. Since then, western blotting methodology has become a common component of the molecular biologists experimental repertoire. A cursory search of PubMed using the term "western blot" suggests that in excess of two hundred and twenty thousand published manuscripts have made use of this technique by the year 2014. Importantly, the last ten years have seen technical imaging advances coupled with the development of sensitive fluorescent labels which have improved sensitivity and yielded even greater ranges of linear detection. The result is a now truly Quantifiable Fluorescence based Western Blot (QFWB) that allows biologists to carry out comparative expression analysis with greater sensitivity and accuracy than ever before. Many "optimized" western blotting methodologies exist and are utilized in different laboratories. These often prove difficult to implement due to the requirement of subtle but undocumented procedural amendments. This protocol provides a comprehensive description of an established and robust QFWB method, complete with troubleshooting strategies.


Assuntos
Western Blotting/métodos , Proteínas/análise , Animais , Química Encefálica , Corantes , Fluorescência , Cavalos , Camundongos , Proteínas Musculares/análise , Músculo Esquelético/química , Proteínas do Tecido Nervoso/análise , Ovinos
9.
Radiother Oncol ; 103(3): 360-6, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22410203

RESUMO

BACKGROUND AND PURPOSE: Pancreatic radiotherapy (RT) is limited by uncertain target motion. We quantified 3D patient/organ motion during pancreatic RT and calculated required treatment margins. MATERIALS AND METHODS: Cone-beam computed tomography (CBCT) and orthogonal fluoroscopy images were acquired post-RT delivery from 13 patients with locally advanced pancreatic cancer. Bony setup errors were calculated from CBCT. Inter- and intra-fraction fiducial (clip/seed/stent) motion was determined from CBCT projections and orthogonal fluoroscopy. RESULTS: Using an off-line CBCT correction protocol, systematic (random) setup errors were 2.4 (3.2), 2.0 (1.7) and 3.2 (3.6)mm laterally (left-right), vertically (anterior-posterior) and longitudinally (cranio-caudal), respectively. Fiducial motion varied substantially. Random inter-fractional changes in mean fiducial position were 2.0, 1.6 and 2.6mm; 95% of intra-fractional peak-to-peak fiducial motion was up to 6.7, 10.1 and 20.6mm, respectively. Calculated clinical to planning target volume (CTV-PTV) margins were 1.4 cm laterally, 1.4 cm vertically and 3.0 cm longitudinally for 3D conformal RT, reduced to 0.9, 1.0 and 1.8 cm, respectively, if using 4D planning and online setup correction. CONCLUSIONS: Commonly used CTV-PTV margins may inadequately account for target motion during pancreatic RT. Our results indicate better immobilisation, individualised allowance for respiratory motion, online setup error correction and 4D planning would improve targeting.


Assuntos
Neoplasias Pancreáticas/radioterapia , Radioterapia Conformacional , Idoso , Tomografia Computadorizada de Feixe Cônico , Feminino , Marcadores Fiduciais , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Movimento , Dosagem Radioterapêutica , Erros de Configuração em Radioterapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...