Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mater Today Chem ; 30: 101597, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37284350

RESUMO

SARS-CoV-2 rapid spread required urgent, accurate, and prompt diagnosis to control the virus dissemination and pandemic management. Several sensors were developed using different biorecognition elements to obtain high specificity and sensitivity. However, the task to achieve these parameters in combination with fast detection, simplicity, and portability to identify the biorecognition element even in low concentration remains a challenge. Therefore, we developed an electrochemical biosensor based on polypyrrole nanotubes coupled via Ni(OH)2 ligation to an engineered antigen-binding fragment of heavy chain-only antibodies (VHH) termed Sb#15. Herein we report Sb#15-His6 expression, purification, and characterization of its interaction with the receptor-binding domain (RBD) of SARS-CoV-2 in addition to the construction and validation of a biosensor. The recombinant Sb#15 is correctly folded and interacts with the RBD with a dissociation constant (KD) of 27.1 ± 6.4 nmol/L. The biosensing platform was developed using polypyrrole nanotubes and Ni(OH)2, which can properly orientate the immobilization of Sb#15-His6 at the electrode surface through His-tag interaction for the sensitive SARS-CoV-2 antigen detection. The quantification limit was determined as 0.01 pg/mL using recombinant RBD, which was expressively lower than commercial monoclonal antibodies. In pre-characterized saliva, both Omicron and Delta SARS-CoV-2 were accurately detected only in positive samples, meeting all the requirements recommended by the World Health Organization for in vitro diagnostics. A low sample volume of saliva is needed to perform the detection, providing results within 15 min without further sample preparations. In summary, a new perspective allying recombinant VHHs with biosensor development and real sample detection was explored, addressing the need for accurate, rapid, and sensitive biosensors.

2.
Mater Today Chem ; 24: 100817, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35155879

RESUMO

The rapid and reliable detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) seroconversion in humans is crucial for suitable infection control. In this sense, many studies have focused on increasing the sensibility, lowering the detection limits and minimizing false negative/positive results. Thus, biosensors based on nanoarchitectures of conducting polymers are promising alternatives to more traditional materials since they can hold improved surface area, higher electrical conductivity and electrochemical activity. In this work, we reported the analytical comparison of two different conducting polymers morphologies for the development of an impedimetric biosensor to monitor SARS-CoV-2 seroconversion in humans. Biosensors based on polypyrrole (PPy), synthesized in both globular and nanotubular (NT) morphology, and gold nanoparticles are reported, using a self-assembly monolayer of 3-mercaptopropionic acid and covalently linked SARS-CoV-2 Nucleocapsid protein. First, the novel hybrid materials were characterized by electron microscopy and electrochemical measurements, and the biosensor step-by-step construction was characterized by electrochemical and spectroscopic techniques. As a proof of concept, the biosensor was used for the impedimetric detection of anti-SARS-CoV-2 Nucleocapsid protein monoclonal antibodies. The results showed a linear response for different antibody concentrations, good sensibility and possibility to quantify 7.442 and 0.4 ng/mL of monoclonal antibody for PPy in the globular and NT morphology, respectively. The PPy-NTs biosensor was able to discriminate serum obtained from COVID-19 positive versus negative clinical samples and is a promising tool for COVID-19 immunodiagnostic, which can contribute to further studies concerning rapid, efficient, and reliable detections.

3.
J Phys Chem B ; 115(38): 11092-7, 2011 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-21870849

RESUMO

In this study, the electrochemical degradation of polyaniline/polystyrene sulfonated (PANI/PSS) self-assembly films was investigated by an electrochemical impedance technique using transmission line models to fit the results. The experiments were performed by polarizing the working electrode at a fixed oxidative potential of 0.55 V. The results showed that changes in the electrochemical behavior of the oxidized PANI/PSS film occurred mainly in the polymer/solution interface by an increase in the charge transfer resistance.

4.
J Phys Chem B ; 115(31): 9570-5, 2011 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-21721565

RESUMO

In this paper, the electrochemical degradation of polypyrrole film was studied by means of overpotential application. The overpotential was 0.58 V versus SCE, and after every 5 min of application of 0.58 V, a cyclic voltammogram was recorded in the range of -0.7 to 0.5 V as well as an electrochemical impedance spectroscopy and electrochemical quartz crystal microbalance (EIS and EQCM). The main characteristic is the huge increase in the charge transfer resistance (r(ct)), which indicates that the insertion process of ions in the polymer matrix is hindered by the electrochemical degradation. Once the process of insertion is damaged, the number of intercalated ions in the matrix should decrease, which is expressed by the low-frequency capacitance, which is proportional to the number of intercalated ions in the polymeric matrix. The decrease of intercalated ions has an influence in the mass variation of the polymer film, which is confirmed by EQCM measurements.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...