1.
Med Phys ; 29(1): 1-5, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11833542

RESUMO

At present there are no specific primary standards for 192Ir high dose rate sources used in brachytherapy. Traceability to primary standards is guaranteed through the method recommended by the AAPM that derives the air kerma calibration factor for the 192Ir gamma rays as the average of the air kerma calibration factors for x-rays and 137Cs gamma-rays or the Maréchal et al. method that uses the energy-weighted air kerma calibration factors for 250 kV x rays and 60Co gamma rays as the air kerma calibration factor for the 192Ir gamma rays. In order to use these methods, it is necessary to use the same buildup cap for all energies and the appropriate wall correction factor for each chamber. This work describes experimental work used to derive the A(W) for four different ionization chambers and different buildup cap materials for the three energies involved in the Maréchal et al. method. The A(W) for the two most common ionization chambers used in hospitals, the Farmer NE 2571 and PTW N30001 is 0.995 and 0.997, respectively, for 250 kV x rays, 0.982 and 0.985 for 192Ir gamma rays, and 0.979 and 0.991 for 60Co gamma rays, all for a PMMA build-up cap of 0.550 gm cm(-2). A comparison between the experimental values and Monte Carlo calculations shows an agreement better than 0.9%. Availability of the A(W) correction factors for all commercial chambers allows users of the in-air calibration jig, provided by the manufacturer, to alternatively use the Maréchal et al. method. Calibration laboratories may also used this method for calibration of a well-type ionization chamber with a comparable accuracy to the AAPM method.


Assuntos
Braquiterapia/instrumentação , Radioisótopos de Irídio/uso terapêutico , Radioterapia/métodos , Braquiterapia/métodos , Calibragem , Radioisótopos de Césio/uso terapêutico , Radioisótopos de Cobalto/uso terapêutico , Raios gama , Método de Monte Carlo
2.
Phys Med Biol ; 44(8): 1897-904, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10473203

RESUMO

As in the method for the calibration of 192Ir high-dose-rate (HDR) brachytherapy sources, the ionization chamber wall correction factor A(w), is needed for 192Ir and 60Co gamma rays and 250 kV x-rays. This factor takes into account the variation in chamber response due to the attenuation of the photon beam in the chamber wall and build-up cap and the contribution of scattered photons. Monte Carlo calculations were performed using the EGS4 code system with the PRESTA algorithm, to calculate the A(w) factor for 51 commercial ionization chambers and build-up caps exposed to the typical energy spectrum of 192Ir and 60Co gamma rays and 250 kV x-rays. The calculated A(w) correction factors for 192Ir and 60Co sources and 250 kV x-rays agree very well to within 0.1% with published experimental data (the statistical uncertainty is less than 0.1% of the calculated correction factor value). For the 192Ir sources, A(w) varies from 0.973 to 0.993 and for the 250 kV x-rays the minimum value of A(w) for all chambers studied is 0.983. The calculated A(w) correction factors can be used to calculate the air kerma calibration factor of HDR brachytherapy sources, when interpolative methods are considered, contributing to the reduction in the overall uncertainties in the calibration procedure.


Assuntos
Braquiterapia/métodos , Radioisótopos de Cobalto/análise , Raios gama , Radioisótopos de Irídio/análise , Método de Monte Carlo , Calibragem , Simulação por Computador , Relação Dose-Resposta à Radiação , Modelos Teóricos , Dosagem Radioterapêutica , Interface Usuário-Computador , Raios X
3.
Phys Med Biol ; 44(3): N31-8, 1999 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10211813

RESUMO

The lack of well established dosimetry protocols for HDR sources is a point of great concern regarding the uniformity of procedures within a particular country and worldwide. The main objective of this paper is to report the results from ten institutions of an intercomparison of calibration procedures for 192Ir HDR sources currently in use in Brazil. The treatment irradiator of one institution was calibrated by a reference system and used by all participants with their own measuring electrometers and ionization chambers under the same experimental conditions. Two methods were used: the calibration jig and the well-type ionization chamber. Each participant was allowed to use their own method and formalism. The results of this exercise were very positive since this was the first time in Brazil that a group of users gathered to share their experience and openly discuss the physical concepts behind the calibration procedures. The results were all within +/-3.0%, except one case where -4.6% was observed and later identified as a problem with the Nk value for x-rays. Though the magnitude of the deviations found was generally acceptable considering the diversity of formalisms currently in use, a proposal is now being prepared to be adopted as a national protocol. The identification of the institutions was left out for the sake of confidentiality.


Assuntos
Radioisótopos de Irídio/análise , Radiometria , Braquiterapia , Brasil , Calibragem , Raios gama