1.
Bioengineering (Basel) ; 10(1)2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-36671652

RESUMO

Radiomics and artificial intelligence have the potential to become a valuable tool in clinical applications. Frequently, radiomic analyses through machine learning methods present issues caused by high dimensionality and multicollinearity, and redundant radiomic features are usually removed based on correlation analysis. We assessed the effect of preprocessing-in terms of voxel size resampling, discretization, and filtering-on correlation-based dimensionality reduction in radiomic features from cardiac T1 and T2 maps of patients with hypertrophic cardiomyopathy. For different combinations of preprocessing parameters, we performed a dimensionality reduction of radiomic features based on either Pearson's or Spearman's correlation coefficient, followed by the computation of the stability index. With varying resampling voxel size and discretization bin width, for both T1 and T2 maps, Pearson's and Spearman's dimensionality reduction produced a slightly different percentage of remaining radiomic features, with a relatively high stability index. For different filters, the remaining features' stability was instead relatively low. Overall, the percentage of eliminated radiomic features through correlation-based dimensionality reduction was more dependent on resampling voxel size and discretization bin width for textural features than for shape or first-order features. Notably, correlation-based dimensionality reduction was less sensitive to preprocessing when considering radiomic features from T2 compared with T1 maps.

2.
Sci Rep ; 12(1): 10186, 2022 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-35715531

RESUMO

Radiomics is emerging as a promising and useful tool in cardiac magnetic resonance (CMR) imaging applications. Accordingly, the purpose of this study was to investigate, for the first time, the effect of image resampling/discretization and filtering on radiomic features estimation from quantitative CMR T1 and T2 mapping. Specifically, T1 and T2 maps of 26 patients with hypertrophic cardiomyopathy (HCM) were used to estimate 98 radiomic features for 7 different resampling voxel sizes (at fixed bin width), 9 different bin widths (at fixed resampling voxel size), and 7 different spatial filters (at fixed resampling voxel size/bin width). While we found a remarkable dependence of myocardial radiomic features from T1 and T2 mapping on image filters, many radiomic features showed a limited sensitivity to resampling voxel size/bin width, in terms of intraclass correlation coefficient (> 0.75) and coefficient of variation (< 30%). The estimate of most textural radiomic features showed a linear significant (p < 0.05) correlation with resampling voxel size/bin width. Overall, radiomic features from T2 maps have proven to be less sensitive to image preprocessing than those from T1 maps, especially when varying bin width. Our results might corroborate the potential of radiomics from T1/T2 mapping in HCM and hopefully in other myocardial diseases.


Assuntos
Cardiomiopatia Hipertrófica , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos
3.
Diagnostics (Basel) ; 12(4)2022 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-35453819

RESUMO

BACKGROUND: A fair amount of microcalcifications sent for biopsy are false positives. The study investigates whether quantitative radiomic features extracted from digital breast tomosynthesis (DBT) can be an additional and useful tool to discriminate between benign and malignant BI-RADS category 4 microcalcification. METHODS: This retrospective study included 252 female patients with BI-RADS category 4 microcalcifications. The patients were divided into two groups according to micro-histopathology: 126 patients with benign lesions and 126 patients with certain or possible malignancies. A total of 91 radiomic features were extracted for each patient, and the 12 most representative features were selected by using the agglomerative hierarchical clustering method. The binary classification task of the two groups was carried out by using four different machine-learning algorithms (i.e., linear support vector machine (SVM), radial basis function (RBF) SVM, logistic regression (LR), and random forest (RF)). Accuracy, sensitivity, sensibility, and the area under the curve (AUC) were calculated for each of them. RESULTS: The best performance was achieved using the RF classifier (AUC = 0.59, 95% confidence interval 0.57-0.60; sensitivity = 0.56, 95% CI 0.54-0.58; specificity = 0.61, 95% CI 0.59-0.63; accuracy = 0.58, 95% CI 0.57-0.59). CONCLUSIONS: DBT-based radiomic analysis seems to have only limited potential in discriminating benign from malignant microcalcifications.

4.
Biomed Res Int ; 2022: 2003286, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35355820

RESUMO

The purpose of this study was to investigate the effect of image preprocessing on radiomic features estimation from computed tomography (CT) imaging of locally advanced rectal cancer (LARC). CT images of 20 patients with LARC were used to estimate 105 radiomic features of 7 classes (shape, first-order, GLCM, GLDM, GLRLM, GLSZM, and NGTDM). Radiomic features were estimated for 6 different isotropic resampling voxel sizes, using 10 interpolation algorithms (at fixed bin width) and 6 different bin widths (at fixed interpolation algorithm). The intraclass correlation coefficient (ICC) and the coefficient of variation (CV) were calculated to assess the variability in radiomic features estimation due to preprocessing. A repeated measures correlation analysis was performed to assess any linear correlation between radiomic feature estimate and resampling voxel size or bin width. Reproducibility of radiomic feature estimate, when assessed through ICC analysis, was nominally excellent (ICC > 0.9) for shape features, good (0.75 < ICC ≤ 0.9) or moderate (0.5 < ICC ≤ 0.75) for first-order features, and moderate or poor (0 ≤ ICC ≤ 0.5) for textural features. A number of radiomic features characterized by good or excellent reproducibility in terms of ICC showed however median CV values greater than 15%. For most textural features, a significant (p < 0.05) correlation between their estimate and resampling voxel size or bin width was found. In CT imaging of patients with LARC, the estimate of textural features, as well as of first-order features to a lesser extent, is appreciably biased by preprocessing. Accordingly, this should be taken into account when planning clinical or research studies, as well as when comparing results from different studies and performing multicenter studies.


Assuntos
Processamento de Imagem Assistida por Computador , Neoplasias Retais , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Retais/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
5.
PLoS One ; 16(1): e0245374, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33444367

RESUMO

Nowadays, given the technological advance in CT imaging and increasing heterogeneity in characteristics of CT scanners, a number of CT scanners with different manufacturers/technologies are often installed in a hospital centre and used by various departments. In this phantom study, a comprehensive assessment of image quality of 5 scanners (from 3 manufacturers and with different models) for head CT imaging, as clinically used at a single hospital centre, was hence carried out. Helical and/or sequential acquisitions of the Catphan-504 phantom were performed, using the scanning protocols (CTDIvol range: 54.7-57.5 mGy) employed by the staff of various Radiology/Neuroradiology departments of our institution for routine head examinations. CT image quality for each scanner/acquisition protocol was assessed through noise level, noise power spectrum (NPS), contrast-to-noise ratio (CNR), modulation transfer function (MTF), low contrast detectability (LCD) and non-uniformity index analyses. Noise values ranged from 3.5 HU to 5.7 HU across scanners/acquisition protocols. NPS curves differed in terms of peak position (range: 0.21-0.30 mm-1). A substantial variation of CNR values with scanner/acquisition protocol was observed for different contrast inserts. The coefficient of variation (standard deviation divided by mean value) of CNR values across scanners/acquisition protocols was 18.3%, 31.4%, 34.2%, 30.4% and 30% for teflon, delrin, LDPE, polystyrene and acrylic insert, respectively. An appreciable difference in MTF curves across scanners/acquisition protocols was revealed, with a coefficient of variation of f50%/f10% of MTF curves across scanners/acquisition protocols of 10.1%/7.4%. A relevant difference in LCD performance of different scanners/acquisition protocols was found. The range of contrast threshold for a typical object size of 3 mm was 3.7-5.8 HU. Moreover, appreciable differences in terms of NUI values (range: 4.1%-8.3%) were found. The analysis of several quality indices showed a non-negligible variability in head CT imaging capabilities across different scanners/acquisition protocols. This highlights the importance of a physical in-depth characterization of image quality for each CT scanner as clinically used, in order to optimize CT imaging procedures.


Assuntos
Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/instrumentação , Algoritmos , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS