Preprint em Inglês | medRxiv | ID: ppmedrxiv-22279847

RESUMO

The COVID-19 pandemic has given rise to numerous commercially available antigen rapid diagnostic tests (Ag-RDTs). To generate and share accurate and independent data with the global community, multi-site prospective diagnostic evaluations of Ag-RDTs are required. This report describes the clinical evaluation of OnSite COVID-19 Rapid Test (CTK Biotech, California, USA) in Brazil and The United Kingdom. A total of 496 paired nasopharyngeal (NP) swabs were collected from symptomatic healthcare workers at Hospital das Clinicas in Sao Paulo, and 211 NP swabs were collected from symptomatic participants at a COVID-19 drive-through testing site in Liverpool, England. These swabs were analysed by Ag-RDT and results were compared to RT-qPCR. The clinical sensitivity of the OnSite COVID-19 Rapid test in Brazil was 90.3% [95% Cl 75.1 - 96.7%] and in the United Kingdom was 75.3% [95% Cl 64.6 - 83.6%]. The clinical specificity in Brazil was 99.4% [95% Cl 98.1 - 99.8%] and in the United Kingdom was 95.5% [95% Cl 90.6 - 97.9%]. Analytical evaluation of the Ag-RDT was assessed using direct culture supernatant of SARS-CoV-2 strains from Wild-Type (WT), Alpha, Delta, Gamma and Omicron lineages. Analytical limit of detection was 1.0x103 pfu/mL, 1.0x103 pfu/mL, 1.0x102 pfu/mL, 5.0x103 pfu/mL and 1.0x103 pfu/mL, giving a viral copy equivalent of approximately 2.1x105 copies/mL, 2.1x104 copies/mL, 1.6x104 copies/mL, 3.5x106 copies/mL and 8.7 x 104 for the Ag-RDT, when tested on the WT, Alpha, Delta, Gamma and Omicron lineages, respectively. This study provides comparative performance of an Ag-RDT across two different settings, geographical areas, and population. Overall, the OnSite Ag-RDT demonstrated a lower clinical sensitivity than claimed by the manufacturer... Sensitivity and specificity from the Brazil study fulfilled the performance criteria determined by the World Health Organisation but the performance obtained from the UK study failed to. Further evaluation of the use of Ag-RDTs should include harmonised protocols between laboratories to facilitate comparison between settings.

2.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-21267455

RESUMO

The limit of detection (LOD) of thirty-two antigen lateral flow tests (Ag-RDT) were evaluated with the SARS-CoV-2 Gamma variant. Twenty-eight of thirty-two Ag-RDTs exceeded the World Health Organization criteria of an LOD of 1.0x106 genome copy numbers/ml and performance was equivalent as with the 2020 B.1 lineage and Alpha variant.

3.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-21256893

RESUMO

BackgroundDuring the last year, mass screening campaigns have been carried out to identify immunological response to SARS-CoV-2 and establish a possible seroprevalence. The obtained results gained new importance with the beginning of SARS-CoV-2 vaccination campaign, as the lack of doses has persuaded several countries to introduce different policies for individuals who had a history of COVID 19. LFAs may represent an affordable tool to support population screening in LMICs, where diagnostic tests are lacking, and epidemiology is still widely unknown. However, LFAs have demonstrated a wide range of performance and the question of which one could be more valuable in these settings still remains. MethodsWe evaluated the performance of 11 LFAs in detecting SARS-CoV-2 infection, analysing samples collected from 350 subjects. In addition, samples from 57 health care workers collected at 21-24 days after the first dose of Pfizer-BioNTech vaccine were also evaluated. FindingsLFAs demonstrated a wide range of specificity (92.31% to 100%) and sensitivity (50 to 100%). The analysis of serum samples post vaccination was used to describe the most suitable tests to detect IgG response against S protein RBD. History of TB therapy was identified as a potential factor affecting the specificity of LFAs. ConclusionsThis analysis identified which LFAs represent a valuable tool not only for the detection of prior SARS-CoV-2 infection, but also to detect IgG elicited in response to vaccination. These results demonstrated that different LFAs may have different applications and the possible risks of their use in high TB burden settings.

4.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-21253076

RESUMO

BackgroundIn 2020, the World Health Organization (WHO) recommended two SARS-CoV-2 lateral flow antigen detecting rapid diagnostics tests (Ag-RDTs), both initially with nasopharyngeal (NP) sample collection. Independent head-to-head studies demonstrated for SARS-CoV-2 Ag-RDTs nasal sampling to be a comparable and reliable alternative for nasopharyngeal (NP) sampling. MethodsWe conducted a head-to-head comparison study of a supervised, self-collected nasal mid-turbinate (NMT) swab and a professional-collected NP swab, using the Panbio Ag-RDT (the second WHO-listed SARS-CoV-2 Ag-RDT, distributed by Abbott). We calculated positive and negative percent agreement and, compared to the reference standard reverse transcription polymerase chain reaction (RT-PCR), sensitivity and specificity for both sampling techniques. ResultsA SARS-CoV-2 infection could be diagnosed by RT-PCR in 45 of 290 participants (15.5%). Comparing the NMT and NP sampling the positive percent agreement of the Ag-RDT was 88.1% (37/42 PCR positives detected; CI 75.0% - 94.8%). The negative percent agreement was 98.8% (245/248; CI 96.5% - 99.6%). The overall sensitivity of Panbio with NMT sampling was 84.4% (38/45; CI 71.2% - 92.3%) and 88.9% (40/45; CI 76.5% - 95.5%) with NP sampling. Specificity was 99.2% (243/245; CI 97.1% - 99.8%) for both, NP and NMT sampling. The sensitivity of the Panbio test in participants with high viral load (> 7 log10 SARS-CoV-2 RNA copies/mL) was 96.3% (CI 81.7% - 99.8%) for both, NMT and NP sampling. ConclusionFor the Panbio Ag-RDT supervised NMT self-sampling yields to results comparable to NP sampling. This suggests that nasal self-sampling could be used for scale-up population testing.

5.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-21252430

RESUMO

BackgroundRapid antigen-detecting tests (Ag-RDTs) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can transform pandemic control. Thus far, sensitivity ([≤]85%) of lateral-flow assays has limited scale-up. Conceivably, microfluidic immunofluorescence Ag-RDTs could increase sensitivity for SARS-CoV-2 detection. Materials and MethodsThis multi-centre diagnostic accuracy study investigated performance of the microfluidic immunofluorescence LumiraDx assay, enrolling symptomatic and asymptomatic participants with suspected SARS-CoV-2 infection. Participants collected a supervised nasal mid-turbinate (NMT) self-swab for Ag-RDT testing, in addition to a professionally-collected nasopharyngeal (NP) swab for routine testing with reverse transcriptase polymerase chain reaction (RT-PCR). Results were compared to calculate sensitivity and specificity. Sub-analyses investigated the results by viral load, symptom presence and duration. An analytical study assessed exclusivity and limit-of-detection (LOD). In addition, we evaluated ease-of-use. ResultsStudy conduct was between November 2nd 2020 and January 21st 2021. 761 participants were enrolled, with 486 participants reporting symptoms on testing day. 120 out of 146 RT-PCR positive cases were detected positive by LumiraDx, resulting in a sensitivity of 82.2% (95% CI: 75.2%-87.5%). Specificity was 99.3% (CI: 98.3-99.7%). Sensitivity was increased in individuals with viral load [≥] 7 log10 SARS-CoV2 RNA copies/ml (93.8%; CI: 86.2%-97.3%). Testing against common respiratory commensals and pathogens showed no cross-reactivity and LOD was estimated to be 2-56 PFU/mL. The ease-of-use-assessment was favourable for lower throughput settings. ConclusionThe LumiraDx assay showed excellent analytical sensitivity, exclusivity and clinical specificity with good clinical sensitivity using supervised NMT self-sampling.

6.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-21250314

RESUMO

BackgroundAntigen-detecting rapid diagnostic tests (Ag-RDTs) for the detection of SARS-CoV-2 offer new opportunities for testing in the context of the COVID-19 pandemic. Nasopharyngeal swabs (NPS) are the reference sample type, but oropharyngeal swabs (OPS) may be a more acceptable sample type in some patients. MethodsWe conducted a prospective study in a single screening center to assess the diagnostic performance of the Panbio COVID-19 Ag Rapid Test (Abbott) on OPS compared with reverse-transcription quantitative PCR (RT-qPCR) using NPS. Results402 outpatients were enrolled in a COVID-19 screening center, of whom 168 (41.8%) had a positive RT-qPCR test. The oropharyngeal Ag-RDT sensitivity compared to nasopharyngeal RT-qPCR was 81% (95%CI: 74.2-86.6). Two false positives were noted out of the 234 RT-qPCR negative individuals, which resulted in a specificity of 99.1% (95%CI: 96.9-99.9) for the Ag-RDT. For cycle threshold values [≤] 26.7 ([≥] 1E6 SARS-CoV-2 genomes copies/mL, a presumed cut-off for infectious virus), 96.3% sensitivity (95%CI: 90.7-99.0%) was obtained with the Ag-RDT using OPS. InterpretationBased on our findings, the diagnostic performance of the Panbio Covid-19 RDT with OPS samples meet the criteria required by the WHO for Ag-RDTs (sensitivity[≥]80% and specificity [≥]97%).

7.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-20239699

RESUMO

BackgroundDiagnostics are essential for controlling the pandemic. Identifying a reliable and fast diagnostic is needed to support testing. We assessed performance and ease-of-use of the Abbott PanBio antigen-detecting rapid diagnostic test (Ag-RDT). MethodsThis prospective, multi-centre diagnostic accuracy study enrolled at two sites in Germany. Following routine testing with RT-PCR, a second study-exclusive swab was performed for Ag-RDT testing. Routine swabs were nasopharyngeal (NP) or combined NP/oropharyngeal (OP) whereas the study-exclusive swabs were NP. To evaluate performance, sensitivity and specificity were assessed overall and in predefined sub analyses accordingly to cycle-threshold values, days of symptoms, disease severity and study site. Additionally, an ease-of-use assessment and System Usability Scale (SUS) were performed. Findings1108 participants were enrolled between Sept 28 and Oct 30, 2020. Of these, 106 (9{middle dot}6%) were PCR-positive. The Abbott PanBio detected 92/106 PCR-positive participants with a sensitivity of 86{middle dot}8% (95% CI: 79{middle dot}0% - 92{middle dot}0%) and a specificity of 99{middle dot}9% (95% CI: 99{middle dot}4%-100%). The sub analyses indicated that sensitivity was 95{middle dot}8% in CT-values <25 and within the first seven days from symptom onset. The test was characterized as easy to use (SUS: 86/100) and considered suitable for point-of- care settings. InterpretationThe Abbott PanBio Ag-RDT performs well for SARS-CoV-2 testing in this large manufacturer independent study, confirming its WHO recommendation for Emergency Use in settings with limited resources. FundingThe Foundation of Innovative New Diagnostics supplied the test kits for the study. The internal funds from the Heidelberg University as well as the Charite Berlin supported this study.

8.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-20235341

RESUMO

BackgroundAntigen-detecting rapid diagnostic tests for SARS-CoV-2 offer new opportunities for the quick and laboratory-independent identification of infected individuals for control of the SARS-CoV-2 pandemic. MethodsWe performed a prospective, single-center, point of care validation of two antigen-detecting rapid diagnostic tests (Ag-RDT) in comparison to RT-PCR on nasopharyngeal swabs. FindingsBetween October 9th and 23rd, 2020, 1064 participants were enrolled. The PanbioCovid-19 Ag Rapid Test device (Abbott) was validated in 535 participants, with 106 positive Ag-RDT results out of 124 positive RT-PCR individuals, yielding a sensitivity of 85.5% (95% CI: 78.0-91.2). Specificity was 100.0% (95% CI: 99.1-100) in 411 RT-PCR negative individuals. The Standard Q Ag-RDT (SD Biosensor, Roche) was validated in 529 participants, with 170 positive Ag-RDT results out of 191 positive RT-PCR individuals, yielding a sensitivity of 89.0% (95%CI: 83.7-93.1). One false positive result was obtained in 338 RT-PCR negative individuals, yielding a specificity of 99.7% (95%CI: 98.4-100). For individuals presenting with fever 1-5 days post symptom onset, combined Ag-RDT sensitivity was above 95%. InterpretationWe provide an independent validation of two widely available commercial Ag-RDTs, both meeting WHO criteria of [≥]80% sensitivity and [≥]97% specificity. Although less sensitive than RT-PCR, these assays could be beneficial due to their rapid results, ease of use, and independence from existing laboratory structures. Testing criteria focusing on patients with typical symptoms in their early symptomatic period onset could further increase diagnostic value. FundingFoundation of Innovative Diagnostics (FIND), Fondation privee des HUG, Pictet Charitable Foundation.