Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Magn Reson Imaging ; 87: 88-96, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35026346

RESUMO

Critical limb ischemia (CLI) is a severe disease which affects about 2 million people in the US. Its prevalence is assessed at 800/100,000 population. However, no reliable tools are currently available to assess perfusion defects at the muscle tissue level. DCE-MRI is a technique that holds the potential to be effective in achieving this goal. However, preclinical studies performed with DCE-MRI have indicated low sensitivity assessing perfusion at resting state. To improve these previous results, in this work we propose new methodologies for data acquisition and analysis and we also revisit the biological model used for evaluation. Eleven rabbits underwent embolization of a lower limb. They were imaged at day 7 after embolization using DCE-MRI, performed on a 4.7 T small imaging device. Among them, n = 4 rabbits were used for MRI sequence optimization and n = 6 for data analysis after one exclusion. Normalized Areas under the curve (AUCn), and kinetic parameters such as Ktrans and Vd resulting from the Tofts-Kety modeling (KTM) were calculated on the embolized and contralateral limbs. Average and heterogeneity features, consisting on standard-deviation and quantiles, were calculated on muscle groups and whole limbs. The Wilcoxon and Fisher-tests were performed to compare embolized and contralateral regions of interests. The Wilcoxon test was also used to compare features of parametric maps. Quantiles of 5 and 95% in the contralateral side were used to define low and high outliers. A P-value <0.05 was considered statistically significant. Average features were inefficient to identify injured muscles, in agreement with the low sensitivity of the technique previously reported by the literature. However, these findings were dramatically improved by the use of additional heterogeneity features (97% of total accuracy for group muscles, P < 0.01 and 100% of total accuracy for the total limbs). The mapping analysis and automatic outlier detection quantification improvement was explained by the presence of local hyperemia that impair the average calculations. The analysis with KTM did not provide any additional information compared to AUCn. The DCE technique can be effective in detecting embolization-induced disorders of limb muscles in a CLI model when heterogeneity is taken into account in the data processing, even without vascular stimulation. The simultaneous presence of areas of ischemia and hyperemia appeared as a signature of the injured limbs. These areas seem to reflect the simultaneous presence of infarcted areas and viable peripheral areas, characterized by a vascular response that is visible in DCE.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética , Animais , Meios de Contraste/farmacologia , Humanos , Isquemia/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/irrigação sanguínea , Músculo Esquelético/diagnóstico por imagem , Perfusão , Coelhos
2.
Adv Mater ; 32(6): e1904598, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31833108

RESUMO

The ability to manipulate cellular organization within soft materials has important potential in biomedicine and regenerative medicine; however, it often requires complex fabrication procedures. Here, a simple, cost-effective, and one-step approach that enables the control of cell orientation within 3D collagen hydrogels is developed to dynamically create various tailored microstructures of cardiac tissues. This is achieved by incorporating iron oxide nanoparticles into human cardiomyocytes and applying a short-term external magnetic field to orient the cells along the applied field to impart different shapes without any mechanical support. The patterned constructs are viable and functional, can be detected by T2 *-weighted magnetic resonance imaging, and induce no alteration to normal cardiac function after grafting onto rat hearts. This strategy paves the way to creating customized, macroscale, 3D tissue constructs with various cell-types for therapeutic and bioengineering applications, as well as providing powerful models for investigating tissue behavior.


Assuntos
Colágeno/química , Nanopartículas de Magnetita/química , Miócitos Cardíacos/citologia , Engenharia Tecidual/instrumentação , Alicerces Teciduais/química , Materiais Biocompatíveis/química , Linhagem Celular , Desenho de Equipamento , Humanos , Hidrogéis/química , Campos Magnéticos , Engenharia Tecidual/métodos
3.
Adv Funct Mater ; 28(21): 1800618, 2018 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-29875619

RESUMO

An auxetic conductive cardiac patch (AuxCP) for the treatment of myocardial infarction (MI) is introduced. The auxetic design gives the patch a negative Poisson's ratio, providing it with the ability to conform to the demanding mechanics of the heart. The conductivity allows the patch to interface with electroresponsive tissues such as the heart. Excimer laser microablation is used to micropattern a re-entrant honeycomb (bow-tie) design into a chitosan-polyaniline composite. It is shown that the bow-tie design can produce patches with a wide range in mechanical strength and anisotropy, which can be tuned to match native heart tissue. Further, the auxetic patches are conductive and cytocompatible with murine neonatal cardiomyocytes in vitro. Ex vivo studies demonstrate that the auxetic patches have no detrimental effect on the electrophysiology of both healthy and MI rat hearts and conform better to native heart movements than unpatterned patches of the same material. Finally, the AuxCP applied in a rat MI model results in no detrimental effect on cardiac function and negligible fibrotic response after two weeks in vivo. This approach represents a versatile and robust platform for cardiac biomaterial design and could therefore lead to a promising treatment for MI.

4.
Tissue Eng Part A ; 21(9-10): 1552-64, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25611092

RESUMO

As part of a program targeted at developing a resorbable valved tube for replacement of the right ventricular outflow tract, we compared three biopolymers (polyurethane [PU], polyhydroxyalkanoate (the poly(3-hydroxybutyrate-co-3-hydroxyvalerate-co-4-hydroxyvalerate) [PHBVV]), and polydioxanone [PDO]) and two biofunctionalization techniques (using adipose-derived stem cells [ADSCs] or the arginine-glycine-aspartate [RGD] peptide) in a rat model of partial inferior vena cava (IVC) replacement. Fifty-three Wistar rats first underwent partial replacement of the IVC with an acellular electrospun PDO, PU, or PHBVV patch, and 31 nude rats subsequently underwent the same procedure using a PDO patch biofunctionalized either by ADSC or RGD. Results were assessed both in vitro (proliferation and survival of ADSC seeded onto the different materials) and in vivo by magnetic resonance imaging (MRI), histology, immunohistochemistry [against markers of vascular cells (von Willebrand factor [vWF], smooth muscle actin [SMA]), and macrophages ([ED1 and ED2] immunostaining)], and enzyme-linked immunosorbent assay (ELISA; for the expression of various cytokines and inducible NO synthase). PDO showed the best in vitro properties. Six weeks after implantation, MRI did not detect significant luminal changes in any group. All biopolymers were evenly lined by vWF-positive cells, but only PDO and PHBVV showed a continuous layer of SMA-positive cells at 3 months. PU patches resulted in a marked granulomatous inflammatory reaction. The ADSC and RGD biofunctionalization yielded similar outcomes. These data confirm the good biocompatibility of PDO and support the concept that appropriately peptide-functionalized polymers may be successfully substituted for cell-loaded materials.


Assuntos
Oligopeptídeos/farmacologia , Polímeros/farmacologia , Células-Tronco/citologia , Engenharia Tecidual/métodos , Veia Cava Inferior/fisiologia , Animais , Biopolímeros/farmacologia , Ensaio de Imunoadsorção Enzimática , Matriz Extracelular/efeitos dos fármacos , Matriz Extracelular/metabolismo , Feminino , Citometria de Fluxo , Implantes Experimentais , Imageamento por Ressonância Magnética , Microscopia Eletrônica de Varredura , Ratos Wistar , Células-Tronco/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...