Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Cardiovasc Intervent Radiol ; 30(6): 1192-200, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17828426

RESUMO

Experimental and clinical data suggest that stents eluting antiproliferative agents can be used for the prevention of in-stent restenosis. Here we investigate in vitro the antiproliferative and apoptotic effect of D-24851 and evaluate the safety and efficacy of D-24851-eluting polymer-coated stents in a rabbit restenosis model (n = 53). Uncoated stents (n = 6), poly (DL: -lactide-co-glycolide) (PLGA)-coated stents (n = 7), and PLGA-coated stents loaded with 0.08 +/- 0.0025 microM (31 +/- 1 mug; low dose; n = 7), 0.55 +/- 0.02 microM (216 +/- 8 mug; high dose; n = 6), and 4.55 +/- 0.1 microM (1774 +/- 39 mug; extreme dose; n = 5) of D-24851 were randomly implanted in New Zealand rabbit right iliac arteries and the animals were sacrificed after 28 days for histomorphometric analysis. For the assessment of endothelial regrowth in 90 days, 12 rabbits were subjected to PLGA-coated (n = 3), low-dose (n = 3), high-dose (n = 3), and extreme-dose (n = 3) stent implantation. In vitro studies revealed that D-24851 exerts its growth inhibitory effects via inhibition of proliferation and induction of apoptosis without increasing the expression of heat shock protein-70, a cytoprotective and antiapoptotic protein. Treatment with low-dose D-24851 stents was associated with a significant reduction in neointimal area and percentage stenosis only compared with bare metal stents (38% [P = 0.029] and 35% [P = 0.003] reduction, respectively). Suboptimal healing, however, was observed in all groups of D-24851-loaded stents in 90 days in comparison with PLGA-coated stents. We conclude that low-dose D-24851-eluting polymer-coated stents significantly inhibit neointimal hyperplasia at 28 days through inhibition of proliferation and enhancement of apoptosis. In view of the suboptimal re-endothelialization, longer-term studies are needed in order to establish whether the inhibition of intimal growth is maintained.


Assuntos
Acetamidas/farmacologia , Implante de Prótese Vascular , Oclusão de Enxerto Vascular/prevenção & controle , Artéria Ilíaca/cirurgia , Indóis/farmacologia , Stents , Túnica Íntima/efeitos dos fármacos , Análise de Variância , Animais , Apoptose , Western Blotting , Cateterismo/instrumentação , Materiais Revestidos Biocompatíveis , Hiperplasia , Masculino , Microscopia Eletrônica de Varredura , Microscopia de Fluorescência , Modelos Animais , Polímeros , Desenho de Prótese , Coelhos , Distribuição Aleatória , Aço Inoxidável , Túnica Íntima/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA