Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
J Comp Eff Res ; : e230186, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38696696

RESUMO

Aim: To evaluate all-cause and liver-associated healthcare resource utilization (HCRU) and costs among patients with alpha-1 antitrypsin deficiency (AATD) with liver disease (LD) and/or lung disease (LgD). Materials & methods: This was a retrospective analysis of linked administrative claims data from the IQVIA PharMetrics® Plus and the IQVIA Ambulatory Electronic Medical Records (AEMR) databases from 1 July 2021 to 31 January 2022. Patients with AATD in the IQVIA PharMetrics Plus database were included with ≥1 inpatient or ≥2 outpatient medical claims ≥90 days apart with a diagnosis of AATD, or with records indicating a protease inhibitor (Pi)*ZZ/Pi*MZ genotype in the IQVIA AEMR database with linkage to IQVIA PharMetrics Plus. For a patient's identified continuous enrollment period, patient time was assigned to health states based on the initial encounter with an LD/LgD diagnosis. A unique index date was defined for each health state, and HCRU and costs were calculated per person-year (PPY). Results: Overall, 5136 adult and pediatric patients from the IQVIA PharMetrics Plus and IQVIA AEMR databases were analyzed. All-cause and liver-associated HCRU and costs were substantially higher following onset of LD/LgD. All-cause cost PPY ranged from US $11,877 in the absence of either LD/LgD to US $74,015 in the presence of both LD and LgD. Among liver transplant recipients in the AATD with LD health state, liver-associated total costs PPY were US $87,329 1-year pre-transplantation and US $461,752 1-year post-transplantation. In the AATD with LgD and AATD with LD and LgD health states, patients who received augmentation therapy were associated with higher all-cause total costs PPY and lower liver-associated total costs PPY than their counterparts who did not receive augmentation therapy. Conclusion: Patients with AATD had increased HCRU and healthcare costs in the presence of LD and/or LgD. HCRU and healthcare costs were highest in the AATD with LD and LgD health state.

2.
Eur J Gastroenterol Hepatol ; 36(4): 404-415, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38417060

RESUMO

BACKGROUND: Vedolizumab is an anti-α4ß7 integrin antibody used to treat moderate to severe ulcerative colitis (UC) and Crohn's disease (CD). This post hoc analysis of patient-reported outcomes (PROs) from the VISIBLE 1 (NCT02611830) and 2 (NCT02611817) phase 3 studies evaluated onset of treatment effect on patient-reported symptoms during 6-week vedolizumab induction. METHODS: Patient-reported stool frequency (SF) and rectal bleeding (RB) (UC Mayo score), and SF and abdominal pain (AP) in CD were collected via electronic diary from VISIBLE patients receiving one or more open-label intravenous (IV) vedolizumab induction doses (weeks 0 and 2). PRO data were analyzed using descriptive statistics. RESULTS: Data from 994 patients (UC 383, CD 611) showed mean ratings for all PROs declined consistently week-on-week from baseline through week 6, with early onset of improvement. By week 2, 22% of patients with UC reported RB improvement (≥1-point reduction in RB subscore, 7-day mean), rising to 45% by week 6. By week 6, 18% of patients with UC achieved SF improvement (SF subscore 0; 21% antitumor necrosis factor alpha [anti-TNFα] naive, 13% anti-TNFα experienced). SF improvement in patients with CD (reduction of ≥3 stools, 7-day mean) was achieved by 32% at week 6 (34% anti-TNFα naive, 30% anti-TNFα experienced). Fewer patients with CD reported severe/moderate AP at week 6 (5.1%/28.5%) than baseline (14.6%/61.5%). SF decline appeared greater and faster for anti-TNFα-naive vs. anti-TNFα-experienced patients (UC and CD). CONCLUSION: Results indicate early onset of patient-reported UC and CD symptom improvement during vedolizumab IV induction in VISIBLE 1 and 2.


Assuntos
Anticorpos Monoclonais Humanizados , Colite Ulcerativa , Doença de Crohn , Humanos , Colite Ulcerativa/diagnóstico , Colite Ulcerativa/tratamento farmacológico , Doença de Crohn/diagnóstico , Doença de Crohn/tratamento farmacológico , Quimioterapia de Indução , Fator de Necrose Tumoral alfa , Medidas de Resultados Relatados pelo Paciente , Fármacos Gastrointestinais/efeitos adversos , Resultado do Tratamento , Indução de Remissão
3.
World J Hepatol ; 15(10): 1127-1139, 2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-37970617

RESUMO

BACKGROUND: Alpha-1 antitrypsin deficiency is a rare genetic disease and a leading cause of inherited alterations in plasma protein metabolism (APPM). AIM: To understand the prevalence, burden and progression of liver disease in patients with APPM including alpha-1 antitrypsin deficiency. METHODS: We conducted a retrospective analysis of anonymized patient-level claims data from a German health insurance provider (AOK PLUS). The APPM cohort comprised patients with APPM (identified using the German Modification of the International Classification of Diseases-10th Revision [ICD-10-GM] code E88.0 between 01/01/2010-30/09/2020) and incident liver disease (ICD-10-GM codes K74, K70.2-3 and K71.7 between 01/01/2012-30/09/2020). The control cohort comprised patients without APPM but with incident liver disease. Outcomes were incidence/prevalence of liver disease in patients with APPM, demographics/baseline characteristics, diagnostic procedures, progression-free survival (PFS), disease progression and mortality. RESULTS: Overall, 2680 and 26299 patients were included in the APPM (fibrosis, 96; cirrhosis, 2584) and control (fibrosis, 1444; cirrhosis, 24855) cohorts, respectively. Per 100000 individuals, annual incidence and prevalence of APPM and liver disease was 10-15 and 36-51, respectively. In the APPM cohort, median survival was 4.7 years [95% confidence interval (CI): 3.5-7.0] and 2.5 years (95%CI: 2.3-2.8) in patients with fibrosis and cirrhosis, respectively. A higher proportion of patients in the APPM cohort experienced disease progression (92.0%) compared with the control cohort (67.2%). Median PFS was shorter in the APPM cohort (0.9 years, 95%CI: 0.7-1.1) compared with the control cohort (3.7 years, 95%CI: 3.6-3.8; P < 0.001). Patients with cirrhosis in the control cohort had longer event-free survival for ascites, hepatic encephalopathy, hepatic failure and esophageal/gastric varices than patients with cirrhosis in the APPM cohort (P < 0.001). Patients with fibrosis in the control cohort had longer event-free survival for ascites, cirrhosis, hepatic failure and esophageal/gastric varices than patients with fibrosis in the APPM cohort (P < 0.001). In the APPM cohort, the most common diagnostic procedures within 12 mo after the first diagnosis of liver disease were imaging procedures (66.3%) and laboratory tests (51.0%). CONCLUSION: Among patients with liver disease, those with APPM experience substantial burden and earlier liver disease progression than patients without APPM.

4.
Aliment Pharmacol Ther ; 58(10): 1075-1085, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37718576

RESUMO

BACKGROUND: Alpha-1 antitrypsin deficiency (AATD) is caused by mutations in SERPINA1, which encodes alpha-1 antitrypsin, a protease inhibitor (Pi). Individuals with AATD and the homozygous Pi*ZZ genotype have variable risk of progressive liver disease but the influence of comorbid lung disease is poorly understood. AIMS: To characterise patients with AATD Pi*ZZ and liver disease (AATD-LD-Pi*ZZ) with or without lung disease and describe liver disease-related clinical events longitudinally. METHODS: This was an observational cohort study of patients in the Mayo Clinic Healthcare System (January 2000-September 2021). Patients were identified using diagnosis codes and natural language processing. Fibrosis stage (F0-F4) was assessed using a hierarchical approach at baseline (90 days before or after the index date) and follow-up. Clinical events associated with liver disease progression were assessed. RESULTS: AATD-LD-Pi*ZZ patients with lung disease had a longer median time from AATD diagnosis to liver disease diagnosis versus those without lung disease (2.2 vs. 0.2 years, respectively). Compared to those without lung disease, patients with lung disease had a longer time to liver disease-related clinical events (8.5 years and not reached, respectively). AATD-LD-Pi*ZZ patients without lung disease were more likely to undergo liver transplantation compared with those with lung disease. CONCLUSION: In patients with AATD and lung disease, there is a delay in the diagnosis of comorbid liver disease. Our findings suggest that liver disease may progress more rapidly in patients without comorbid lung disease.


Assuntos
Pneumopatias , Deficiência de alfa 1-Antitripsina , Humanos , Deficiência de alfa 1-Antitripsina/complicações , Deficiência de alfa 1-Antitripsina/diagnóstico , Deficiência de alfa 1-Antitripsina/genética , Pneumopatias/complicações , Genótipo , Progressão da Doença , Inibidores de Proteases
5.
J Virol Methods ; 300: 114373, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34826517

RESUMO

BACKGROUND: HIV-1 viral load assays are essential tools for clinical management of people living with HIV-1. OBJECTIVES AND STUDY DESIGN: We evaluated concordance between three assays: the cobas® HIV-1 test for use on the cobas® 6800 and cobas® 8800 systems (cobas HIV-1); the COBAS® TaqMan® HIV-1 Test, v2.0 for use with the High Pure System and the COBAS® AmpliPrep/COBAS® TaqMan® HIV-1 test, v2.0. Analytical sensitivity, precision and accuracy of all three methods were assessed using the WHO 2nd International Standard for HIV-1, with concentrations from 5 to 1000 copies/mL. Accuracy and concordance were evaluated using 212 clinical specimens. Overall percent agreement (OPA) was determined using three different thresholds used as medical decision points. RESULTS: The limit of detection was below 20 copies/mL for each assay. The hit rate for each assay was 100 % for concentrations ≥ 50 copies/mL. Only the cobas HIV-1 test generated quantifiable data for all replicates at 50 copies/mL. Between 50 and 400 copies/mL, results for all assays were accurate within 0.09 log10 copies/mL, with standard deviation less than 0.14 log10 copies/mL. The mean difference between paired results in clinical specimens ranged from -0.050 to 0.107 log10 copies/mL across all assay comparisons. The OPA between pairs of assays ranged from 94.8 to 98.1% at the 50 copies/mL cutoff, and improved to a range of 97.6-99.0% at the 200 copies/mL cutoff. At the 1000 copies/mL cutoff, OPA between assays was 98.5-99.0%. CONCLUSIONS: The cobas HIV-1 assay is highly sensitive, accurate and suitable for use in clinical practice.


Assuntos
Infecções por HIV , HIV-1 , Bioensaio , Infecções por HIV/diagnóstico , HIV-1/genética , Humanos , RNA Viral , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade , Carga Viral/métodos
6.
J Clin Virol ; 140: 104839, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33991979

RESUMO

BACKGROUND: Measurement of HIV-1 viral load (VL) is essential for monitoring antiretroviral treatment (ART) efficacy. In remote settings, dried blood spots (DBS) may be used as the specimen type. However, cellular components in DBS not present in the gold standard specimen type, plasma, may result in low specificity i.e., over-estimation of VL results from DBS compared to plasma. The Abbott RealTime HIV-1 assay system has been reported to have improved specificity using DBS compared to other tests. A new specimen collection matrix, the cobas plasma separation card (PSC, Roche Molecular Systems), enables specimen collection from a finger prick or venous blood, using a multi-layer absorption and filtration design that results in a specimen similar to plasma. OBJECTIVES AND STUDY DESIGN: We performed a direct comparison between VL results from PSC tested with the cobas 6800/8800 assay (c8800) and DBS tested with the Abbott RealTime HIV-1 assay. RESULTS: Overall concordance between PSC and plasma around the 1000 copies/mL threshold was high (>97%). Compared to VL measured using DBS and the RealTime assay, PSC and c8800 showed improved sensitivity (96.9% vs 90.6%) and specificity (97.4% vs. 87.2%) using plasma as the reference, as there were fewer patients with VL below 1000 copies/mL in plasma in whom VL was over this threshold using PSC compared to DBS. The limit of detection for PSC was lower than for DBS (575 vs. 2314 copies/mL). CONCLUSIONS: cobas PSC represents a promising specimen type for use with the cobas 6600/8800 system in settings where plasma cannot be used.


Assuntos
Infecções por HIV , HIV-1 , Teste em Amostras de Sangue Seco , Infecções por HIV/tratamento farmacológico , HIV-1/genética , Humanos , RNA Viral , Sensibilidade e Especificidade , Manejo de Espécimes , Falha de Tratamento , Carga Viral
7.
Hepatol Commun ; 4(7): 983-997, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32626831

RESUMO

Despite effective hepatitis B virus (HBV)-DNA suppression, HBV RNA can circulate in patients receiving nucleoside/nucleotide analogues (NAs). Current assays quantify HBV DNA by either real-time polymerase chain reaction (PCR), which uses DNA polymerase, or transcription-mediated amplification, which uses reverse-transcriptase (RT) and RNA polymerase. We assessed the effect of RT capability on HBV-DNA quantification in samples from three cohorts, including patients with quantified HBV RNA. We compared the HBV-DNA levels by real-time PCR (cobas HBV, Roche 6800/8800; Xpert HBV, Cepheid), transcription-mediated amplification (Aptima HBV, Hologic), and real-time PCR with added RT capability (cobas HBV+RT). In the first cohort (n = 45) followed over 192 weeks of NA therapy, on-treatment HBV-DNA levels were higher with cobas HBV+RT than cobas HBV (mean difference: 0.14 log10 IU/mL). In a second cohort (n = 50) followed over 96 weeks of NA therapy, HBV-DNA viral load was significantly higher with the cobas HBV+RT and Aptima HBV compared with the cobas HBV test at all time points after initiation of NA therapy (mean difference: 0.65-1.16 log10 IU/mL). A clinically significant difference was not detected between the assays at baseline. In a third cohort (n = 53), after a median of 2.2 years of NA therapy, we detected HBV RNA (median 5.6 log10 copies/mL) in 23 patients (43.4%). Median HBV-DNA levels by Aptima HBV were 2.4 versus less than 1 log10 IU/mL in samples with HBV RNA and without HBV RNA, respectively (P = 0.0006). In treated patients with HBV RNA, Aptima HBV measured higher HBV-DNA levels than Xpert HBV and cobas HBV. Conclusion: Tests including an RT step may overestimate HBV DNA, particularly in samples with low viral loads as a result of NA therapy. This overestimation is likely due to amplification of HBV RNA and may have an impact on clinical decisions.

8.
J Virol Methods ; 278: 113820, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31945390

RESUMO

OBJECTIVE: This study evaluated the performance of the cobas® hepatitis C virus (HCV) Test for use on the cobas® 6800/8800 Systems for the detection and quantification of HCV RNA collected using the cobas® Plasma Separation Card (PSC) compared with plasma samples. METHODS: Whole EDTA-venous blood was collected from 50 HCV-positive donors and 140 µL from each donor was spotted onto a PSC and stored either frozen or at ambient temperature. These were compared with matched EDTA-plasma samples. The limit of detection (LoD) of the assay for PSC samples was determined using serial dilutions of the Roche HCV secondary calibration standard. The stability of the PSC samples across a range of timepoints was also assessed. RESULTS: The mean titer difference between ambient and -10 °C storage of PSC samples was 0.04 log10 IU/mL (95% CI: 0.00, 0.07). The mean titer difference between frozen PSC samples and EDTA plasma samples was -1.59 log10 IU/mL (95% CI: -1.66, -1.53) and between ambient PSC samples and EDTA samples was -1.64 log10 IU/mL (95% CI: -1.70, -1.57). Correlation between PSC samples and EDTA plasma was linear in both cases (frozen: slope = 1.039, intercept=-1.839, R2 = 0.89; ambient: slope = 1.012, intercept=-1.712, R2 = 0.88). The LoD of the cobas® HCV Test using the PSC was 866 IU/mL (95% CI: 698, 1153 IU/mL) and 408 IU/mL (95% CI: 336, 544 IU/mL) using an optimized Assay Specific Analysis Package. CONCLUSIONS: PSC samples correlate well with plasma viral load and demonstrate a LoD below 1000 IU/mL and good stability at ambient temperature for 28 days. A correction factor would allow quantification of HCV viral RNA load from samples collected using a PSC.


Assuntos
Teste em Amostras de Sangue Seco/instrumentação , Teste em Amostras de Sangue Seco/normas , Hepatite C Crônica/diagnóstico , RNA Viral/isolamento & purificação , Carga Viral , Genótipo , Hepacivirus , Hepatite C/diagnóstico , Hepatite C Crônica/sangue , Humanos , Limite de Detecção , Sensibilidade e Especificidade
9.
Sex Transm Dis ; 47(5S Suppl 1): S32-S34, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31895305

RESUMO

BACKGROUND: Diagnosis of HCV, HBV, and HIV involves antibody screening followed by confirmation and/or treatment decision using nucleic acid tests. However, minimal data exist evaluating the risk of nucleic acid cross-contamination on serology devices upstream of molecular testing despite the potential clinical and laboratory workflow advantages of single specimen vial testing for both procedures. METHODS: We conducted a checkerboard study investigating the potential risk of HCV, HBV, and HIV nucleic acid cross-contamination on 480 negative specimens by a serology screening instrument that uses disposable tips for sample transfer, rather than a fixed needle, before molecular testing. RESULTS: Nucleic acid contamination was observed in 0 of 480 negative specimens when processed with alternating high-titer HCV, HBV, or HIV specimens on the serology platform. CONCLUSIONS: This study suggests that specimens analyzed by a serology instrument using disposable tips for sample transfer may be suitable for direct primary specimen reflex testing by a sensitive nucleic acid confirmatory test.


Assuntos
Automação Laboratorial/métodos , Técnicas de Laboratório Clínico/instrumentação , Técnicas de Laboratório Clínico/métodos , Hepacivirus/genética , Técnicas de Diagnóstico Molecular/métodos , RNA Viral/isolamento & purificação , Manejo de Espécimes/métodos , Contaminação de Equipamentos , Infecções por HIV/diagnóstico , Infecções por HIV/virologia , Hepatite B/diagnóstico , Hepatite B/virologia , Hepatite C/diagnóstico , Hepatite C/virologia , Humanos , Programas de Rastreamento/instrumentação , Programas de Rastreamento/métodos , Medição de Risco , Fatores de Tempo , Fluxo de Trabalho
10.
PLoS One ; 14(11): e0224751, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31738773

RESUMO

BACKGROUND: The COBAS AmpliPrep/COBAS TaqMan assay HCV (CAP/CTM) is widely used in clinical routine for HCV testing. Recently, the new cobas HCV test was established for high throughput testing with minimal operator intervention. As different assays may yield different quantitative/qualitative results that possibly impact treatment decisions, the aim of this study was to externally evaluate the cobas HCV test performance in comparison to CAP/CTM in a clinically relevant setting. METHODS: Serum samples were obtained from 270 patients who received direct acting antiviral therapy with different treatment regimens at two study sites (Hannover and Frankfurt) in 2016. Overall, 1545 samples (baseline, on-treatment and follow-up) were tested in parallel by both assays. RESULTS: The mean difference between cobas HCV and CAP/CTM for the quantification of HCV RNA was 0.008 log10 IU/ml HCV RNA (95% limits of agreement: -0.02-0.036) showing excellent agreement of both assays. With respect to clinical cut offs (HCV RNA detectable vs. target not detected and HCV RNA above the lower limit of quantification (LLOQ) vs.

Assuntos
Antivirais/administração & dosagem , Monitoramento de Medicamentos/instrumentação , Hepacivirus/isolamento & purificação , Hepatite C Crônica/tratamento farmacológico , Carga Viral/efeitos dos fármacos , Adulto , Hepacivirus/genética , Hepatite C Crônica/sangue , Hepatite C Crônica/virologia , Ensaios de Triagem em Larga Escala/instrumentação , Humanos , Técnicas de Diagnóstico Molecular/instrumentação , RNA Viral/genética , RNA Viral/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/instrumentação
11.
Expert Rev Mol Diagn ; 19(10): 951-957, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31526152

RESUMO

Background: Molecular diagnostic tests for HBV, HCV and HIV-1 and other pathogens are widely used for clinical management. Practical issues related to workflow and labor requirements need to be characterized to inform selection of the most appropriate system. Research design and methods: We compared the workflow of two high-throughput systems: cobas 6800 (Roche) and Panther (Hologic), using average mid-size laboratory test volumes for five different assays (HIV-1, HBV, HCV, HPV or TV, and CT/NG). Results: Set-up time, time to first results, time to last results, and total hands-on time for cobas 6800 was 0.40, 2.47, 7.12, and 0.98 hours, respectively; on the Panther system, these times were 0.75, 2.7, 9.1, and 1.48 hours. Fifty-seven samples had results available at the first time point on cobas 6800 compared to 5 samples on the Panther system. The Panther system required more manual steps including several with potential risks of contamination or error. The number of reagents items required was 5 for cobas 6800 and 40 for the Panther system. Conclusions: Both systems provided a high level of automation. The cobas 6800 platform had shorter start up, time to first result, time to last result and hands-on times than the Panther system.


Assuntos
Técnicas de Diagnóstico Molecular/métodos , Viroses/diagnóstico , Vírus/genética , Automação Laboratorial/métodos , Humanos , Patologia Molecular , Kit de Reagentes para Diagnóstico , Viroses/virologia , Fluxo de Trabalho
12.
Expert Rev Mol Diagn ; 19(10): 941-949, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31159598

RESUMO

Background: Viral load (VL) quantification is important for the management of HBV, HCV, and HIV-1-infected patients. Several semi- or fully automated systems and assays are available that can be used to measure VL for these and other targets. Research design and methods: We assessed the accuracy, genotype/subtype inclusivity, and precision of four VL assays for three viral targets: cobas 4800 (Roche), cobas 6800 (Roche), Aptima (Hologic) and VERIS (Beckman), using WHO standards, cell culture supernatants and clinical samples. Results: Most results were close to expected values, except for significant under-quantification of HIV-1 group O, HBV genotype C, and D at high VL, and HCV genotype 3 by Aptima, and of HIV-1 CRF01_AE and group N and HCV genotype 3 by VERIS. Precision was comparable between tests except for VERIS HCV, which showed more variability. Aptima and cobas 6800 results agreed well with each other except HBV VL at lower VL (<10,000 IU/mL) where Aptima results tended to be higher. Conclusions: Results from different VL assays may not always agree in certain subsets of patients. Clinicians should we aware of these findings when making treatment decisions.


Assuntos
DNA Viral/genética , HIV-1/genética , Hepacivirus/genética , Vírus da Hepatite B/genética , RNA Viral/genética , Carga Viral/genética , Automação Laboratorial/métodos , Genótipo , Humanos , Técnicas de Diagnóstico Molecular/métodos , Kit de Reagentes para Diagnóstico
13.
J Clin Virol ; 114: 43-49, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30991164

RESUMO

BACKGROUND AND OBJECTIVES: Measurement of HIV-1 viral load (VL) is necessary to monitor treatment efficacy in patients receiving antiretroviral therapy. We evaluated the performance of the cobas® HIV-1 quantitative nucleic acid test for use on the cobas® 4800 system ("cobas 4800 HIV-1"). METHODS: Limit of detection, linearity, accuracy, precision, and specificity of cobas 4800 HIV-1, COBAS® AmpliPrep/COBAS® Taqman® HIV-1 version 2.0 (CAP/CTM HIV-1 v2) and Abbott RealTime HIV-1 were determined in one or two out of three sites. RESULTS: The limit of detection of the cobas 4800 HIV-1 for 400 µL and 200 µL input volumes was 14.2 copies/mL (95% CI: 12.5-16.6 copies/mL) and 43.9 copies/mL (37.7-52.7 copies/mL), respectively. Cobas 4800 HIV-1 demonstrated 100% specificity, and results were linear for all analyzed group M HIV-1 subtypes. Precision was high (SD < 0.19 log10) across all measured ranges, reagent lots and input volumes. Correlation between cobas 4800 HIV-1 and CAP/CTM HIV-1 v2 or RealTime HIV-1 was high (R2 ≥ 0.95). Agreement between cobas 4800 HIV-1 and CAP/CTM HIV-1 v2 was 96.5% (95.0%-97.7%) at a threshold of 50 copies/mL, and 97.2% (95.8%-98.3%) at 200 copies/mL. Agreement between cobas 4800 HIV-1 and RealTime HIV-1 was 96.6% (93.4%-98.5%) at 50 copies/mL, and 97.0% (94.0%-98.8%) at 200 copies/mL. The mean difference between cobas 4800 HIV-1 and CAP/CTM HIV-1 v2 or RealTime HIV-1 was -0.10 log10 or 0.01 log10, respectively. CONCLUSIONS: The cobas 4800 HIV-1 test is highly sensitive, accurate and correlated well with other assays, including agreement around clinically relevant thresholds, indicating minimal overall VL quantification differences between tested platforms.


Assuntos
Infecções por HIV/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/normas , Kit de Reagentes para Diagnóstico/normas , Carga Viral/métodos , Carga Viral/normas , Infecções por HIV/sangue , HIV-1 , Humanos , Limite de Detecção , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA Viral/sangue , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
J Clin Virol ; 102: 63-69, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29518694

RESUMO

BACKGROUND AND OBJECTIVES: Accurate, sensitive, and specific tests for detection and monitoring of hepatitis C virus (HCV) RNA concentrations are essential for diagnosis and management of HCV infections. We evaluated the next-generation reverse-transcription real-time PCR test, cobas® HCV test for use with the cobas® 6800/8800 systems ("cobas HCV") by determining its analytical performance characteristics and clinical utility for the diagnosis and therapeutic monitoring of chronic HCV infections. METHODS: The limit of detection (LOD), linearity, precision, specificity, matrix equivalence of plasma and serum, and quantitative agreement with the COBAS® AmpliPrep/COBAS® TaqMan® HCV Test version 2.0 ("CAP/CTM HCV v2") were evaluated. Clinical utility for the diagnosis of chronic HCV infection was demonstrated by testing plasma from HCV seropositive individuals and comparing results to a nucleic acid amplification test (NAAT) approved for use in the diagnosis of chronic hepatitis C. Clinical specificity was investigated by testing plasma from HCV antibody negative subjects with non-HCV related liver diseases. Utility for monitoring treatment response was defined by testing plasma collected during treatment of HCV genotypes (GT) 1, 2, and 3 and determining positive predictive value (PPV), negative predictive value (NPV) and the odds ratio (OR) for predicting cure (sustained virologic response 12 weeks after treatment cessation, "SVR12"). RESULTS: The cobas HCV test demonstrated an LOD of at least 15 IU/mL and measurable range from 15 to at least 1.0E + 08 IU/mL (1.2-8.0 log10 IU/mL) for GT 1-6, with high accuracy (≤0.16 log10 difference) and precision (standard deviation 0.04-0.14 log10) throughout the linear range. Paired plasma and serum samples showed highly correlated performance (R2 = 0.97). Quantification was 100% specific for HCV in analytical studies. Correlation with CAP/CTM HCV v2 was high in patient samples (mean titer difference: 0.05 log10 with a 95% CI: 0.03-0.06 log10). For the diagnosis of chronic HCV, positive and negative percent agreement between cobas HCV and the comparator NAAT were 98.8-100% on the cobas 6800 and 8800 systems. Clinical specificity of cobas HCV using samples from HCV antibody negative subjects with non-HCV related liver diseases was 99.6% and 100% on cobas 6800 and 8800 systems. In therapeutic monitoring and SVR12 prediction during experimental treatment for chronic HCV GT 1 infections, undetectable HCV RNA by cobas HCV at different on-treatment weeks had a PPV 76.8%-79.4%, NPV 29.9%-100%, and OR 1.64-47.52. During therapy of HCV GT 2 and GT 3, treatment week 4 and 12 results were: PPV, 84.7% and 75.3%; NPV, 47.8% and 50.0%; OR, 5.09 and 3.05. CONCLUSIONS: The cobas HCV test is highly sensitive, specific, and accurate HCV RNA test for GT 1-6. It demonstrates excellent correlation with the FDA-approved CAP/CTM HCV v2 test. It is useful clinically for detection of active HCV infection in individuals that have had a positive anti-HCV antibody test result and in monitoring treatment response.


Assuntos
Monitoramento de Medicamentos/métodos , Hepatite C/diagnóstico , Técnicas de Diagnóstico Molecular , Genótipo , Hepacivirus/genética , Hepacivirus/isolamento & purificação , Hepatite C/tratamento farmacológico , Anticorpos Anti-Hepatite C/sangue , Hepatite C Crônica/diagnóstico , Hepatite C Crônica/tratamento farmacológico , Humanos , Limite de Detecção , Técnicas de Diagnóstico Molecular/normas , RNA Viral/sangue , RNA Viral/genética , Kit de Reagentes para Diagnóstico , Reação em Cadeia da Polimerase em Tempo Real , Sensibilidade e Especificidade , Carga Viral
15.
Therap Adv Gastroenterol ; 10(8): 609-618, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28835775

RESUMO

BACKGROUND: HBV DNA is the most important molecular marker in hepatitis B, used to determine treatment indication and monitoring. Most patients require lifelong hepatitis B virus (HBV) management, thus viral load (VL) monitoring may be performed at different laboratories, with different HBV assays, which may result in different VL results. This multicenter study compares the commutability and concordance of results from four different HBV DNA assays: CAP/CTM HBVv2, HPS/CTM HBVv2 and the new cobas 6800/8800 HBV and cobas 4800 HBV assays. METHODS: Across all four assays, HBV limit of detection (LoD) and linearity at lower concentrations were assessed using panels traceable to the World Health Organization international standard, and concordance was investigated at the important medical decision cutoffs 2000 and 20,000 IU/ml, using specimens from HBV-positive patients. RESULTS: The calculated LoD via a probit curve was 2.7 IU/ml for cobas 6800/8800 HBV, 2.8 IU/ml for cobas 4800 HBV, 9.6 IU/ml for CAP/CTM HBVv2, and 6.2 IU/ml for HPS/CTM HBVv2. The average accuracy was comparable between cobas 6800/8800 HBV, cobas 4800 HBV and CAP/CTM HBVv2 (0.04-0.05 log10 IU/ml), while a slightly lower accuracy was documented for HPS/CTM HBVv2 (-0.16 log10 IU/ml). A total of 211-245 clinical samples were used for a pairwise comparison. Mean paired log differences ranged from -0.17 log10 IU/ml to -0.01 log10 IU/ml. Coefficient of determination was over 98% for all pairs with high overall percent agreement at the 2000 and 20,000 IU/ml cutoffs (from 91.7% to 96.3%). In a subset of samples with VL±0.5 log10 to the 2000 and 20,000 IU/ml thresholds, concordance was still 72% and 82%, respectively. CONCLUSIONS: The new cobas 6800/8800 HBV and 4800 HBV assays show high accuracy in samples with low-level viremia and a high concordance with the established HBV tests, CAP/CTM HBVv2 and HPS/CTM HBVv2, at 2000 and 20,000 IU/ml. Thus, all four HBV assays have high commutability and may be used interchangeably in routine clinical practice.

16.
PLoS One ; 12(7): e0181273, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28742818

RESUMO

Hepatitis C virus (HCV) intergenotypic recombinant forms have been reported for various HCV genotypes/subtypes in several countries worldwide. In a recent study, four patients living in Austria had been identified to be possibly infected with a recombinant HCV strain. To clarify results and determine the point of recombination, full-genome next-generation sequencing using the Illumina MiSeq v2 300 cycle kit (Illumina, San Diego, CA, USA) was performed in the present study. Samples of all of the patients contained the recombinant HCV strain 2k/1b. The point of recombination was found to be within the HCV NS2 gene between nucleotide positions 3189-3200 based on H77 numbering. While three of four patients were male and had migration background from Chechnya (n = 2) and Azerbaijan (n = 1), the forth patient was a female born in Austria. Three of the four patients including the female had intravenous drug abuse as a risk factor for HCV transmission. While sequencing techniques are limited to a few specialized laboratories, a genotyping assay that uses both ends of the HCV genome should be employed to identify patients infected with a recombinant HCV strain. The correct identification of recombinant strains also has an impact considering the tailored choice of anti-HCV treatment.


Assuntos
Hepacivirus/genética , Hepatite C/virologia , Proteínas não Estruturais Virais/genética , Áustria/epidemiologia , Feminino , Genótipo , Técnicas de Genotipagem/métodos , Hepatite C/epidemiologia , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Masculino , Filogenia , Recombinação Genética
17.
J Virol Methods ; 247: 77-80, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28576449

RESUMO

This study evaluated the use of dried blood spot (DBS) for HCV viral load quantification using the COBAS® AmpliPrep/COBAS® Taqman® HCV Quantitative Test v2.0 (CAP/CTM HCV v2), and compared two different procedures for preparation of DBS samples with a Specimen Pre-Extraction (SPEX) reagent (either heated [SPEX with SH] for 10min at 56°C on a thermomixer, or incubated for 1h at room temperature [SPEX at RT]) against the standard plasma input. Whole blood specimens from 48 patients with chronic HCV infection and Whatman® 903 Protein Saver Cards were used to prepare 35µL DBS. An aliquot of plasma was spun and frozen from each draw. Mean DBS viral load results were compared to the corresponding results from plasma. Correlation between DBS to plasma was linear for both SPEX with SH (R2=0.96) and SPEX at RT (R2=0.97) procedures, with a constant negative offset of approximately 2.0log10IU/mL between whole blood DBS without any adjustments and plasma results. After volume corrections, the mean offset to plasma decreased to -0.39 and -0.36 for the two procedures, respectively. The study demonstrated the use of DBS for HCV viral load correlates well with plasma with a constant offset.


Assuntos
Dessecação , Hepacivirus/isolamento & purificação , Hepatite C Crônica/virologia , Kit de Reagentes para Diagnóstico , Manejo de Espécimes/métodos , Carga Viral/métodos , Humanos , Plasma/virologia
18.
J Virus Erad ; 3(1): 1-6, 2017 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-28275452

RESUMO

Hepatitis B infection remains a significant disease burden around the world, with an estimated two billion individuals infected and 350 million living with chronic hepatitis B. Current antivirals are efficacious, but require lifelong treatment for the majority of infected individuals. The field is galvanised to improve diagnostics and treatment with the goal to develop shorter, finite treatments leading to viral control after treatment discontinuation. Achievement of complete and functional cure is challenged by the complexity of the virus life cycle, the lack of adequate preclinical models, the cccDNA-mediated persistence of HBV in liver cells, the lack of validated biomarkers to predict viral control and cure, and the probable need for combination treatment involving antiviral- and immune-based strategies. Experts from diverse stakeholder groups participating in the HBV Forum (a project of the Forum for Collaborative Research) contributed their expertise and perspective to resolving issues and overcoming barriers in the regulatory path for novel HBV therapeutic strategies; addressing gaps in preclinical models, diagnostics, clinical trial design, biomarkers and endpoints, and public health efforts. Interviewees highlighted the need for open and collaborative ongoing dialogues among stakeholders in a neutral space as a critical process to move the field forwards. The Forum model facilitates dialogue and deliberation of this nature, with dedicated experts from all stakeholder groups participating. The promise of an HBV cure is exciting. Now is the time to work together toward that goal.

19.
J Clin Microbiol ; 55(4): 1131-1139, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28122870

RESUMO

The efficacy of antiviral treatment for chronic hepatitis C virus (HCV) infection is determined by measuring HCV RNA at specific time points throughout therapy using highly sensitive and accurate HCV RNA assays. This study compared the performances of two recently developed real-time PCR HCV RNA assays, cobas HCV for use on the cobas 6800/8800 systems (cobas 6800/8800 HCV) and cobas HCV for use on the cobas 4800 system (cobas 4800 HCV), with those of two established assays, the Cobas AmpliPrep/Cobas TaqMan HCV quantitative test, version 2 (CAP/CTM v2) and the Cobas TaqMan HCV test, version 2 for use with the High Pure system (HPS/CTM v2). The limits of detection (LODs) and linearity at lower concentrations (5 to 1000 IU/ml) were assessed for cobas 6800/8800 HCV and cobas 4800 HCV using WHO standard traceable panels representing HCV genotypes (GT) 1 to 4. Pairwise assay comparisons were also performed using 245 clinical samples representing HCV GT 1 to GT 4. Results from cobas 6800/8800 HCV and cobas 4800 HCV were linear at low HCV RNA concentrations (<0.3 log10 IU/ml difference between expected and observed results) with LODs of 8.2 IU/ml and 11.7 IU/ml, respectively, for GT 1. The new assays showed excellent agreement with results from CAP/CTM v2 and HPS/CTM v2 in samples with quantifiable viral loads. The concordances using the 6 million IU/ml cutoff were high among all four assays (90 to 94%). In conclusion, the cobas 6800/8800 HCV and cobas 4800 HCV tests are sensitive and linear and correlate well with the established Roche assays used in clinical practice.


Assuntos
Hepacivirus/isolamento & purificação , Hepatite C/virologia , RNA Viral/análise , Carga Viral/métodos , Humanos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sensibilidade e Especificidade
20.
Clin Chem Lab Med ; 55(4): 517-521, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27740913

RESUMO

BACKGROUND: Determination of the hepatitis C virus (HCV) genotype and discrimination between HCV subtypes 1a and 1b is still mandatory prior to anti-HCV treatment initiation. The aim of this study was to evaluate the performance of the recently introduced cobas® HCV GT assay (Roche) and to compare it to two comparator assays. METHODS: The cobas® HCV GT assay is based on primer-specific real-time polymerase chain reaction (PCR). For comparison, the TRUGENE® HCV 5'NC Genotyping Kit (Siemens) and the VERSANT® HCV Genotype 2.0 Assay (Siemens) were employed. Accuracy of the new assay was determined using proficiency panels. For clinical evaluation, 183 residual clinical samples obtained from patients with chronic hepatitis C infection were included. RESULTS: When accuracy was tested, panel members containing HCV subtypes 1a, 1b, and 3a were identified as expected; however, the new assay failed to identify low titer panel members containing HCV subtype 5a correctly. Of 183 clinical samples, 160 gave concordant results. For seven samples, an indeterminate result was reported with the cobas® HCV GT assay and the remaining 16 samples were found discordant with one of the comparator assays. When time-to-results of the assays were compared, the new assay showed shorter total time and similar hands-on time per sample. CONCLUSIONS: The cobas® HCV GT assay showed a good performance and proved to be suitable for use in the routine diagnostic laboratory. Due to the high level of automation, fast and reliable results are obtained with short hands-on time.


Assuntos
Hepacivirus/genética , Hepatite C Crônica/virologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , Genoma Viral , Genótipo , Humanos , Kit de Reagentes para Diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...