Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Food Chem ; 262: 168-177, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29751905

RESUMO

A novel and reliable method to quantify residual levels of N-(3-aminopropyl)-N-dodecylpropane-1,3-diamine in dairy products using ion-pairing reversed-phase liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and fully validated. Sample extraction was done with salting-out technique using acetonitrile and sodium chloride. For LC-MS/MS, the analyte was detected using positive electrospray ionization (ESI+) and two multiple reaction monitoring (MRM) transitions were monitored. The method was validated in the 5-150 µg kg-1 range using total error approach. Thus, performance criteria of the method were evaluated. Relative standard deviations for trueness and precision were lower than 10%; with the exception of hard pressed cheese at 5 µg kg-1 for precision. The limit of quantification (LOQ) was around 5-7 µg kg-1 depending on the matrix of interest. The method was successfully applied to accurately quantify N-(3-aminopropyl)-N-dodecylpropane-1,3-diamine in 146 various dairy products with a maximum contamination level of 225 µg kg-1 in cheese.


Assuntos
Cromatografia de Fase Reversa/métodos , Laticínios/análise , Propilaminas/análise , Espectrometria de Massas em Tandem/métodos , Queijo/análise , Desinfetantes/análise , Limite de Detecção , Propilaminas/isolamento & purificação
2.
J Chromatogr A ; 1517: 86-96, 2017 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-28851528

RESUMO

Quaternary ammonium compounds (QACs) are both cationic surfactants and biocidal substances widely used as disinfectants in the food industry. A sensitive and reliable method for the analysis of benzalkonium chlorides (BACs) and dialkyldimethylammonium chlorides (DDACs) has been developed that enables the simultaneous quantitative determination of ten quaternary ammonium residues in dairy products below the provisional maximum residue level (MRL), set at 0.1mgkg-1. To the best of our knowledge, this method could be the one applicable to milk and to three major processed milk products selected, namely processed or hard pressed cheeses, and whole milk powder. The method comprises solvent extraction using a mixture of acetonitrile and ethyl acetate, without any further clean-up. Analyses were performed by liquid chromatography coupled with electrospray tandem mass spectrometry detection (LC-ESI-MS/MS) operating in positive mode. A C18 analytical column was used for chromatographic separation, with a mobile phase composed of acetonitrile and water both containing 0.3% formic acid; and methanol in the gradient mode. Five deuterated internal standards were added to obtain the most accurate quantification. Extraction recoveries were satisfactory and no matrix effects were observed. The method was validated using the total error approach in accordance with the NF V03-110 standard in order to characterize the trueness, repeatability, intermediate precision and analytical limits within the range of 5-150µgkg-1 for all matrices. These performance criteria, calculated by e.noval® 3.0 software, were satisfactory and in full accordance with the proposed provisional MRL and with the recommendations in the European Union SANTE/11945/2015 regulatory guidelines. The limit of detection (LOD) was low (<1.9µgkg-1) and the limit of quantification (LOQ) ranged from 5µgkg-1 to 35µgkg-1 for all matrices depending on the analytes. The validation results proved that the method is suitable for quantifying quaternary ammoniums in foodstuffs from dairy industries at residue levels, and could be used for biocide residues monitoring plans and to measure the exposition consumer to biocides products.


Assuntos
Queijo/análise , Cromatografia Líquida de Alta Pressão , Análise de Alimentos/métodos , Leite/química , Compostos de Amônio Quaternário/análise , Espectrometria de Massas em Tandem , Acetonitrilas/química , Animais , Compostos de Benzalcônio/análise , Limite de Detecção
3.
Int J Food Microbiol ; 151(1): 98-104, 2011 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-21924791

RESUMO

In recent years, raw fruits and vegetables have frequently been involved in foodborne transmission to humans of enteric viruses, particularly noroviruses and hepatitis A virus (HAV). Although viral contamination can occur during all steps of food processing, primary production is a critical stage on which prevention measures must be focused to minimize the risk of infection to consumers. Postharvest sanitation may be a valid technological solution for decreasing the bacterial load on fresh raw material, but there is a lack of data concerning the effectiveness of this process on enteric viruses. In this study, we compared the survival of two human norovirus surrogates, the feline calicivirus (FCV), and the murine norovirus (MNV-1), and of HAV on lettuce after water washing with bubbles and with or without ultrasound, and washing with bubbles in the presence of active chlorine (15 ppm) or peroxyacetic acid-based disinfectant (100 ppm). Cell culture and quantitative RT-PCR assays were used to detect and quantify the viruses on the surface of the lettuce after the sanitizing treatments. Levels of viral inactivation on the lettuce leaves were not significantly different between washing with bubbles and washing with bubbles plus ultrasound and were not dependant on the quantification method. A simple washing without disinfectant resulted in a decrease of approximately 0.7 log units in the quantity of virus detected for HAV and FCV and of 1.0 log unit for MNV-1. In the experimental set-up including a washing step (with or without ultrasound) followed by washing for 2 min in the presence of disinfectants, 15 ppm of active chlorine was found more effective for inactivating FCV (2.9 log units) than HAV and MNV-1 (1.9 log units and 1.4 log units, respectively) whereas 100 ppm of peroxyacetic-based biocide was found effective for inactivating FCV (3.2 log units) and MNV-1 (2.3 log units), but not HAV (0.7 log units). Quantitative RT-PCR results indicated that the presence of viral RNA did not correlate with the presence of infectious viruses on disinfected lettuce, except for MNV-1 processed with chlorine (15 ppm). In comparison with water washing, a substantial additional decrease of genomic FCV titer (1.1 log units) but no significant reduction of the genomic titers of HAV and MNV-1 were found on lettuce treated with chlorine (15 ppm). No significant effect of the disinfection step of lettuce with peroxyacetic-based biocide (100 ppm peracetic acid) was found by qRT-PCR on all genomic viral titers tested. This study illustrates the necessity of determining the effectiveness of technological processes against enteric viruses, using a relevant reference such as HAV, in order to reduce the risk of hepatitis and gastroenteritis by exposure to vegetables.


Assuntos
Calicivirus Felino/efeitos dos fármacos , Cloro/farmacologia , Desinfetantes/farmacologia , Vírus da Hepatite A/efeitos dos fármacos , Lactuca/virologia , Norovirus/efeitos dos fármacos , Ácido Peracético/farmacologia , Animais , Linhagem Celular , Desinfecção , Manipulação de Alimentos/métodos , RNA Viral/análise , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Inativação de Vírus/efeitos dos fármacos
5.
Vet J ; 177(3): 388-93, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17851101

RESUMO

A number of commercially available disinfectants are commonly used on pig breeding farms and are authorised by the French Agricultural Ministry. However, the efficacy of these disinfectants is unknown with regard to the emergent porcine circovirus type 2 (PCV2). The virucidal efficacy of nine disinfectants was evaluated by testing a suspension of PCV2 isolated in France. The assays were performed at 20 degrees C and the efficacy determined after 30 min contact time between virus and disinfectant. After this time, the mixture was passed through a detoxification column and then diluted to remove compounds toxic to the virus and the porcine kidney cell line. The filtrate was serially diluted and inoculated onto cell culture. The infectivity of PCV2 was determined by an immunoperoxidase monolayer assay. No reduction in PCV2 titre was demonstrated with iodine and phenolic products. Significant PCV2 titre reductions (1.61 log(10)) were noted for the seven other products. For five disinfectants, namely a product composed of potassium monopersulfate, two products comprising a quaternary ammonium with one or three aldehyde(s), sodium hypochlorite, and sodium hydroxide, the concentration that significantly reduced the PCV2 titre was equal or 1.5-4 times lower than the authorised use concentration. Only two disinfectants, one composed of potassium monopersulfate, the other containing peracetic acid with hydrogen peroxide, reduced the PCV2 titre with a product concentration at best equal or two times higher than the authorised use concentration.


Assuntos
Antivirais/farmacologia , Infecções por Circoviridae/veterinária , Circovirus/efeitos dos fármacos , Desinfetantes/farmacologia , Doenças dos Suínos/tratamento farmacológico , Animais , Linhagem Celular , Infecções por Circoviridae/tratamento farmacológico , Infecções por Circoviridae/prevenção & controle , Relação Dose-Resposta a Droga , Testes de Sensibilidade Microbiana/veterinária , Suínos , Doenças dos Suínos/prevenção & controle , Temperatura , Resultado do Tratamento
6.
J AOAC Int ; 85(4): 889-900, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12180684

RESUMO

A collaborative study involving 14 laboratories was conducted to determine residues of ampicillin in porcine muscle tissue by using a liquid chromatographic method developed for multipenicillin analysis that can quantitate 8 penicillin compounds (benzylpenicillin, phenoxymethylpenicillin, ampicillin, amoxicillin, nafcillin, oxacillin, cloxacillin, and dicloxacillin) at trace levels in muscle tissue. This method involves extraction of the penicillins with phosphate buffer, pH 9, followed by cleanup and concentration on a C18 solid-phase extraction column and reaction with benzoic anhydride at 50 degrees C and with 1,2,4-triazole and mercury(II) chloride solution, pH 9.0, at 65 degrees C. The derivatized compounds are eluted isocratically on a C8 column with a mobile phase of acetonitrile and phosphate buffer (pH 6; 0.1 M) containing sodium thiosulfate and the ion-pair reagent tetrabutylammonium hydrogen sulfate. The penicillins are detected by UV absorption at 325 nm. The limit of detection and the limit of determination (quantitation) of the method were calculated to be approximately 3-5 and 25 microg/kg, respectively, in accordance with the criteria of European Union (EU) Decision No. 93/256/EEC. In this first interlaboratory study, collaborators were instructed to monitor 4 different penicillin compounds (benzylpenicillin, phenoxymethylpenicillin, ampicillin, and amoxicillin) by analyzing 8 blind samples of muscle tissue in triplicate. These samples were prepared from 2 materials containing different concentrations of incurred ampicillin (63.5 microg/kg for material No. 1 and 358.1 microg/kg for material No. 2) and 1 blank material. The repeatability relative standard deviation and the reproducibility relative standard deviation were 10.2 and 17.4%, respectively, for material No. 1 and 7.0 and 16.0%, respectively, for material No. 2. These results demonstrate that the method is suitable for the determination of ampicillin residues in muscle tissue at the EU maximum residue limit (50 microg/kg) and above. However, the identification of positives by this procedure may need additional confirmation by techniques with greater specificity, such as liquid chromatography combined with mass spectrometry, or tandem mass spectrometry. Investigations regarding the basis of interlaboratory testing studies will further demonstrate the suitability of multiresidue methodology for detecting and quantitating other compounds in the family of penicillin antibiotics.


Assuntos
Ampicilina/análise , Cromatografia Líquida/métodos , Contaminação de Alimentos/análise , Animais , Cromatografia Líquida/instrumentação , Cromatografia Líquida/normas , União Europeia , Laboratórios , Carne/análise , Músculo Esquelético/química , Penicilinas/análise , Controle de Qualidade , Reprodutibilidade dos Testes , Sus scrofa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...