Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 154: 108863, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31513990

RESUMO

The nuclide 231Pa is a member of the 235U decay chain. It is a complex alpha emitter with 25 identified alpha emissions. Formerly published alpha-particle emission probabilities were derived from measurements taken with magnetic spectrometers. This work presents the first measurements made with semiconductor detectors. High-resolution alpha-particle spectrometry was carried out at CIEMAT and JRC using ion-implanted planar silicon detectors. Alpha-particle emission probabilities of 23 transitions were derived from deconvolutions of the spectra. For the major lines, uncertainties are lower than 1%, a significant improvement to existing data. The new data set will allow a more accurate evaluation of the decay scheme of 231Pa.

2.
Appl Radiat Isot ; 153: 108821, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31394469

RESUMO

Two optical distance measurement devices have been compared for accurately defining the source-detector geometry of alpha-particle counters. The first consists of a travelling microscope with unifocal lens, to which a linear distance gauge is attached. The focusing is done by human eye. The second is a modern 3D coordinate measurement machine, equipped with a CMOS colour camera as the sensor. Focusing is performed automatically by software. With both devices, distance measurements of various drop-deposited sources on glass and stainless steel disks have been performed. There is a good mutual agreement of results. Even though the new device can sample more reference points, the accuracy of the measurements has not improved drastically due to the imperfect flatness of the sources. The main advantages of the new system are its ease of use and the lower health risk involved due to the larger distance between the performer and the source.

3.
Appl Radiat Isot ; 153: 108848, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31442878

RESUMO

A windowless Peltier-cooled silicon drift detector (SDD) was used to measure internal conversion electron (ICE) spectra of thin 241Am sources. The ICE peaks associated with the 59.54 keV gamma transition in 237Np were deconvoluted and relative ICE intensities were derived from the fitted peak areas. Corrections were made for energy dependence of the full-energy-peak counting efficiency, based on Monte Carlo simulations. As expected for this anomalous E1 transition, a significant discrepancy was found with the theoretical internal conversion coefficient (ICC) values calculated from the BrIcc database. Penetration effects are known to cause such anomalies in highly retarded transitions. The measured ICE intensities are in good agreement with a specific combination of literature data obtained with magnetic spectrometers.

4.
Appl Radiat Isot ; 144: 34-46, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30522082

RESUMO

The emission probabilities of γ rays produced in the 227Ac decay series were determined by high-resolution γ-ray spectrometry of sources with standardised activity. The sources were prepared quantitatively on glass discs by drop deposition of a solution with 227Ac in radioactive equilibrium with its daughter nuclides. Their activity was measured by a primary standardisation technique based on alpha-particle counting at a defined low solid angle. Four laboratories performed γ-ray spectrometry and derived absolute γ-ray intensities. Mean values were calculated and compared with literature data and the currently recommended evaluated data. New values on certain γ-ray emission probabilities are proposed.

5.
Appl Radiat Isot ; 134: 233-239, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28964594

RESUMO

Internal conversion electron (ICE) spectra of thin 238,239,240Pu sources, measured with a windowless Peltier-cooled silicon drift detector (SDD), were deconvoluted and relative ICE intensities were derived from the fitted peak areas. Corrections were made for energy dependence of the full-energy-peak counting efficiency, based on Monte Carlo simulations. A good agreement was found with the theoretically expected internal conversion coefficient (ICC) values calculated from the BrIcc database.

6.
Appl Radiat Isot ; 132: 72-78, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29169063

RESUMO

Accurate measurements were performed of the photon emission probabilities following the α decay of 235U to 231Th. Sources of highly enriched 235U were characterised in terms of isotopic composition by mass spectrometry and their activities were standardised by means of alpha-particle counting at a low defined solid angle. The standardised sources were subsequently measured by high-resolution γ-ray spectrometry with calibrated high-purity germanium detectors to determine the photon emission probabilities. Four laboratories participated in this work and reported emission probabilities for 33 γ-ray lines. Most of them agree with previously published evaluated data. In addition, new values are proposed for γ-lines which have been measured only once in the past.

7.
Appl Radiat Isot ; 125: 196-202, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28476016

RESUMO

High-resolution alpha-particle spectrometry was performed to determine the main alpha-particle emission probabilities in the decay of 226Ra. Thin, homogeneous sources were prepared by electrodeposition on stainless steel disks. Alpha spectra with an energy resolution of 20keV were obtained in three laboratories and analysed with different deconvolution algorithms. In two set-ups, a magnet system was used to deflect conversion electrons to avoid their coincidental detection with the alpha particles. Spectra taken at close range without a magnet system yielded biased results which cannot be fully compensated by statistical corrections for coincidence summing. The derived emission probabilities of the three main alpha decays are 94.07 (1)%, 5.93 (1)%, and 0.0059 (15)%, respectively. They are in excellent agreement with calculated values derived from the P(γ+ce) decay scheme balance, which solves the existing discrepancy problem with two previous direct measurements published in literature.

8.
Phys Lett B ; 761: 281-286, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-28057978

RESUMO

The hypothesis that proximity to the Sun causes variation of decay constants at permille level has been tested and disproved. Repeated activity measurements of mono-radionuclide sources were performed over periods from 200 days up to four decades at 14 laboratories across the globe. Residuals from the exponential nuclear decay curves were inspected for annual oscillations. Systematic deviations from a purely exponential decay curve differ from one data set to another and are attributable to instabilities in the instrumentation and measurement conditions. The most stable activity measurements of alpha, beta-minus, electron capture, and beta-plus decaying sources set an upper limit of 0.0006% to 0.008% to the amplitude of annual oscillations in the decay rate. Oscillations in phase with Earth's orbital distance to the Sun could not be observed within a 10-6 to 10-5 range of precision. There are also no apparent modulations over periods of weeks or months. Consequently, there is no indication of a natural impediment against sub-permille accuracy in half-life determinations, renormalisation of activity to a distant reference date, application of nuclear dating for archaeology, geo- and cosmochronology, nor in establishing the SI unit becquerel and seeking international equivalence of activity standards.

9.
Appl Radiat Isot ; 87: 315-9, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24355304

RESUMO

The alpha-particle emission probabilities associated with the three main alpha transitions of (238)U were measured by high-resolution alpha-particle spectrometry. Highly enriched (238)U material was used and its isotopic composition characterised by mass spectrometry. Source production through electrodeposition was optimised to reconcile conflicting demands for good spectral resolution and statistical precision. Measurements were performed at IRMM and CIEMAT for 1-2 years in three different set-ups. A new magnet system was put into use to largely eliminate true coincidence effects with low-energy conversion electrons. Finally the accuracy and precision of the relative emission probabilities for the three transitions - 77.01 (10)%, 22.92 (10)% and 0.068 (10)%, respectively - have been improved significantly.

10.
Appl Radiat Isot ; 87: 320-4, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24291529

RESUMO

A new magnet system has been designed and constructed to reduce coincidence effects between alpha particles and conversion electrons in high-resolution alpha-particle spectrometry. By means of a magnetic field, the conversion electrons are deflected away from the PIPS(®) detector. Compared to existing magnet systems, the new system is not restricted to point sources and can accommodate source diameters up to about 30 mm. Two yokes were built, allowing for configurations with 20 mm or 36 mm distance between the magnets. The effectiveness of both configurations is demonstrated by measuring the conversion electron spectrum of a (237)Np source. The magnet system effectively rejects 93 (7)% of electrons up to 85 keV (36 mm) and 90 (9)% of electrons up to 320 keV (20 mm). It has been successfully applied in the alpha-particle spectrometry of the long-lived nuclides (236)U and (238)U, resulting in significant improvement of the accuracy of alpha emission probabilities.

11.
Appl Radiat Isot ; 87: 292-6, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24309010

RESUMO

High-resolution alpha-particle spectrometry was performed with an ion-implanted silicon detector in vacuum on a homogeneously electrodeposited (236)U source. The source was measured at different solid angles subtended by the detector, varying between 0.8% and 2.4% of 4π sr, to assess the influence of coincidental detection of alpha-particles and conversion electrons on the measured alpha-particle emission probabilities. Additional measurements were performed using a bending magnet to eliminate conversion electrons, the results of which coincide with normal measurements extrapolated to an infinitely small solid angle. The measured alpha emission probabilities for the three main peaks - 74.20 (5)%, 25.68 (5)% and 0.123 (5)%, respectively - are consistent with literature data, but their precision has been improved by at least one order of magnitude in this work.

12.
Appl Radiat Isot ; 77: 32-7, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23511775

RESUMO

The half-lives of (221)Fr, (217)At, (213)Bi, (213)Po, and (209)Pb were measured by means of an ion-implanted planar Si detector for alpha and beta particles emitted from weak (225)Ac sources or from recoil sources, which were placed in a quasi-2π counting geometry. Recoil sources were prepared by collecting atoms from an open (225)Ac source onto a glass substrate. The (221)Fr and (213)Bi half-lives were determined by following the alpha particle emission rate of recoil sources as a function of time. Similarly, the (209)Pb half-life was determined from the beta particle count rate. The shorter half-lives of (217)At and (213)Po were deduced from delayed coincidence measurements on weak (225)Ac sources using digital data acquisition in list mode. The resulting values: T1/2((221)Fr)=4.806 (6) min, T1/2((217)At)=32.8 (3)ms, T1/2((213)Bi)=45.62 (6)min, T1/2((213)Po)=3.708 (8) µs, and T1/2((209)Pb)=3.232 (5)h were in agreement only with the best literature data.


Assuntos
Actínio/química , Algoritmos , Metais/análise , Metais/química , Radioisótopos/análise , Radioisótopos/química , Radiometria/métodos , Meia-Vida , Doses de Radiação , Compostos Radiofarmacêuticos
13.
Appl Radiat Isot ; 74: 123-7, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23416406

RESUMO

In this work, (213)Bi has been separated from an open (225)Ac source by collecting recoil atoms onto a glass plate in vacuum. The activity of such recoil sources has been measured as a function of time, using an ion-implanted planar Si detector in quasi-2π geometry. From these measurements, a new half-life value of T1/2((213)Bi)=45.62 (6)min was derived. Additionally, high-resolution alpha-spectrometry measurements were performed at a solid angle of 0.4% of 4πsr, to verify the energies and emission probabilities of the α-emissions from (213)Bi. Using (225)Ac, (221)Fr, (217)At and (213)Po peaks as reference peaks, the measured (213)Bi α-peak energies at Eα,0=5878 (4)keV and Eα,1=5560 (4)keV were about 10keV higher than validated data. The relative α-particle emission probabilities of (213)Bi, Pα,0=0.9155 (11) and Pα,1=0.0845 (11), and the (213)Bi alpha branching factor, Pα=1-Pß=2.140 (10)%, are compatible with recommended values, but have a higher accuracy.

14.
Appl Radiat Isot ; 70(11): 2608-14, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22940415

RESUMO

The (225)Ac half-life was determined by measuring the activity of (225)Ac sources as a function of time, using various detection techniques: α-particle counting with a planar silicon detector at a defined small solid angle and in a nearly-2π geometry, 4πα+ß counting with a windowless CsI sandwich spectrometer and with a pressurised proportional counter, gamma-ray spectrometry with a HPGe detector and with a NaI(Tl) well detector. Depending on the technique, the decay was followed for 59-141 d, which is about 6-14 times the (225)Ac half-life. The six measurement results were in good mutual agreement and their mean value is T(1/2)((225)Ac)=9.920 (3)d. This half-life value is more precise and better documented than the currently recommended value of 10.0 d, based on two old measurements lacking uncertainty evaluations.


Assuntos
Actínio/química , Partículas alfa , Meia-Vida , Doses de Radiação , Radioatividade
15.
Appl Radiat Isot ; 70(9): 1900-6, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22464791

RESUMO

The (230)U half-life was determined by measuring the decay curve of (230)U sources by various nuclear detection techniques: α-particle counting at a defined small solid angle; 4πα+ß counting with a windowless CsI sandwich spectrometer, a liquid scintillation counter and a pressurised proportional counter; gamma-ray spectrometry with a HPGe detector and nearly-2π α-particle counting with an ion-implanted silicon detector. Depending on the technique, the decay was followed for 100-200 d, which is 5-10 times the (230)U half-life. The measurement results of the various techniques were in good mutual agreement. The mean value, T(1/2)((230)U)=20.23 (2) d, is lower than the literature value which is based on one measurement in 1948 and resulted in a half-life value of 20.8d without statement of uncertainty. A correction for the ingrowth of the long-lived (210)Pb and its daughter products may have been overlooked in the past.


Assuntos
Radiometria/instrumentação , Radiometria/normas , Urânio/análise , Urânio/química , Meia-Vida , Internacionalidade , Doses de Radiação , Padrões de Referência , Valores de Referência
16.
Appl Radiat Isot ; 70(9): 2270-4, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22424835

RESUMO

High-resolution alpha-particle spectrometry was performed on the (230)U decay series. A (230)U source was prepared on a stainless steel disc by electrodeposition in an ammonium nitrate solution. Spectrometry of the alpha-particle energy spectrum was performed with ion-implanted planar silicon detectors in vacuum. A set of alpha emission probabilities is presented for (230)U and (226)Th. The measured peak intensities were corrected mathematically for coincidental detection of alpha-particles and conversion electrons emitted in the same decay. A good agreement with literature data was observed. The uncertainty budget and the correlation matrix are presented. The validity of the alpha-particle energies was tested and could be confirmed for most peaks within a few keV, but discrepancies were found for the 2nd peak of (226)Th and the main peak of (218)Rn.


Assuntos
Radioisótopos/análise , Radioisótopos/normas , Radiometria/instrumentação , Análise Espectral/instrumentação , Análise Espectral/métodos , Urânio/análise , Partículas alfa , Meia-Vida , Doses de Radiação , Radioisótopos/química
17.
Appl Radiat Isot ; 70(9): 1907-12, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22436449

RESUMO

The half-lives of (214)Po and (218)Rn have been measured. The radionuclides were produced in the decay of a (230)U source and the emitted alpha-particles were measured in nearly-2π geometry with an ion-implanted planar silicon detector. The data acquisition was performed with a digitiser operated in list mode, saving the energy and time of detection (10 ns precision timestamp) of each event. The half-lives were deduced from the time differences between the alpha-decays populating the nuclide of interest and those corresponding to its decay. Different methods were applied, based on delayed coincidence counting and time-interval distribution analysis. The resulting half-lives are 33.75 (15) ms for (218)Rn and 164.2 (6) µs for (214)Po, both in agreement with some of the literature values, and obtained with higher precision in this work.


Assuntos
Eletrônica/instrumentação , Armazenamento e Recuperação da Informação/métodos , Polônio/química , Radiometria/instrumentação , Radônio/química , Desenho de Equipamento , Análise de Falha de Equipamento , Meia-Vida , Polônio/análise , Doses de Radiação , Radônio/análise , Processamento de Sinais Assistido por Computador
18.
Appl Radiat Isot ; 70(9): 1913-8, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22445397

RESUMO

The half-lives of (226)Th and (222)Ra were measured by counting alpha-particle emissions from sources as a function of time. The (226)Th sources were prepared from an open (230)U source, capturing recoil atoms after alpha-particle decay on glass disks or even directly onto a detector. Similarly, the (222)Ra sources were obtained by self-transfer of recoil atoms from (226)Th sources. The activity measurements were performed in (nearly-)2π geometry with an ion-implanted silicon detector. The decay curves were analysed in different ways, incl. moment analysis, trying to avoid the pitfalls of bias of least-squares fits to Poisson distributed data. The observed half-life values are T(1/2)((226)Th)=30.70 (3) min and T(1/2)((222)Ra)=33.6 (4) s. Literature values show some inconsistency.


Assuntos
Radiometria/instrumentação , Rádio (Elemento)/química , Tório/química , Desenho de Equipamento , Análise de Falha de Equipamento , Meia-Vida , Doses de Radiação , Rádio (Elemento)/análise , Tório/análise
19.
Appl Radiat Isot ; 68(7-8): 1378-82, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20022258

RESUMO

A primary standard for positron-emitters in gas has been developed. The method involves internal gas proportional counting and the use of the PENELOPE Monte Carlo code to determine corrections for counting losses. The development work was carried out using (11)C, although the method can be applied to other positron emitters. The results were compared with measurements of (11)C (in solution) carried out using a secondary standard re-entrant ionisation chamber previously calibrated with reference to absolute counting techniques.

20.
Phys Med Biol ; 52(2): N51-9, 2007 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-17202616

RESUMO

Proton therapy is increasingly used in medical treatments for cancer patients due to the sharp dose conformity offered by the characteristic Bragg peak. Proton beam interactions with the eye will be simulated using the MCNPX Monte Carlo code and available nuclear cross-section data to calculate the dose distribution in the eye gel and surrounding organs. A high-resolution eye model will be employed using a 3D geometrical voxel-based anthropomorphic head phantom obtained from the Visible Human Project (female data). Manual segmentation of the eye, carried out by the Medical Physics group at the University of Surrey resulted in 15 identified structures. This work emphasizes the use of a realistic phantom for accurately predicting dose deposition by protons.


Assuntos
Antropometria/métodos , Neoplasias Oculares/radioterapia , Radiometria/métodos , Radioterapia de Alta Energia/métodos , Humanos , Imageamento por Ressonância Magnética , Método de Monte Carlo , Imagens de Fantasmas , Prótons , Software , Tomografia Computadorizada por Raios X , Projetos Ser Humano Visível
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...