Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 11(1): 9128, 2021 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-33911152

RESUMO

A monolithic lab-on-a-chip fabricated by femtosecond laser micromachining capable of label-free biosensing is reported. The device is entirely made of fused silica, and consists of a microdisk resonator integrated inside a microfluidic channel. Whispering gallery modes are excited by the evanescent field of a circular suspended waveguide, also incorporated within the channel. Thermal annealing is performed to decrease the surface roughness of the microstructures to a nanometric scale, thereby reducing intrinsic losses and maximizing the Q-factor. Further, thermally-induced morphing is used to position, with submicrometric precision, the suspended waveguide tangent to the microresonator to enhance the spatial overlap between the evanescent field of both optical modes. With this fabrication method and geometry, the alignment between the waveguide and the resonator is robust and guaranteed at all instances. A maximum sensitivity of 121.5 nm/RIU was obtained at a refractive index of 1.363, whereas near the refractive index range of water-based solutions the sensitivity is 40 nm/RIU. A high Q-factor of 105 is kept throughout the entire measurement range.

2.
Biosens Bioelectron ; 26(9): 3932-7, 2011 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-21489775

RESUMO

Cyanobacteria deteriorate the water quality and are responsible for emerging outbreaks and epidemics causing harmful diseases in Humans and animals because of their toxins. Microcystin-LR (MCT) is one of the most relevant cyanotoxin, being the most widely studied hepatotoxin. For safety purposes, the World Health Organization recommends a maximum value of 1 µg L(-1) of MCT in drinking water. Therefore, there is a great demand for remote and real-time sensing techniques to detect and quantify MCT. In this work a Fabry-Pérot sensing probe based on an optical fibre tip coated with a MCT selective thin film is presented. The membranes were developed by imprinting MCT in a sol-gel matrix that was applied over the tip of the fibre by dip coating. The imprinting effect was obtained by curing the sol-gel membrane, prepared with (3-aminopropyl) trimethoxysilane (APTMS), diphenyl-dimethoxysilane (DPDMS), tetraethoxysilane (TEOS), in the presence of MCT. The imprinting effect was tested by preparing a similar membrane without template. In general, the fibre Fabry-Pérot with a Molecular Imprinted Polymer (MIP) sensor showed low thermal effect, thus avoiding the need of temperature control in field applications. It presented a linear response to MCT concentration within 0.3-1.4 µg L(-1) with a sensitivity of -12.4±0.7 nm L µg(-1). The corresponding Non-Imprinted Polymer (NIP) displayed linear behaviour for the same MCT concentration range, but with much less sensitivity, of -5.9±0.2 nm L µg(-1). The method shows excellent selectivity for MCT against other species co-existing with the analyte in environmental waters. It was successfully applied to the determination of MCT in contaminated samples. The main advantages of the proposed optical sensor include high sensitivity and specificity, low-cost, robustness, easy preparation and preservation.


Assuntos
Técnicas Biossensoriais , Interferometria , Microcistinas/isolamento & purificação , Poluentes Químicos da Água/isolamento & purificação , Cianobactérias/química , Água Potável/química , Toxinas Marinhas , Membranas/química , Microcistinas/química , Impressão Molecular , Fibras Ópticas , Polimetil Metacrilato
3.
Opt Express ; 18(9): 9413-22, 2010 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-20588787

RESUMO

Integrated optics coaxial two, three and four telescope beam combiners have been fabricated by hybrid sol-gel technology for astronomical applications. Temporal and spectral analyses of the output interferometric signal have been performed, and their results are in mutual good agreement. The results of the characterization method employed are cross-checked using contrast measurements obtained independently, demonstrating that the chromatic differential dispersion is the main contributer to contrast reduction. The mean visibility of the fabricated devices is always higher than 95 %, obtained using a source with spectral bandwidth of 50 nm. These results show the capability of hybrid sol-gel technology for fast prototyping of complex chip designs used in astronomical applications.

4.
Opt Lett ; 34(16): 2474-6, 2009 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-19684820

RESUMO

A micrometric Fabry-Perot refractometer based on an end-of-fiber polymer tip is proposed. The fiber tip, with a length of 36 mum, was fabricated by self-guiding photopolymerization. The two-wave interferometric operation was achieved by combining the light waves generated at the interface between the single-mode fiber and the polymer tip, and at the fiber tip end (Fresnel reflection). The Fabry-Perot interferometer is coherence addressed and heterodyne interrogated, resulting into a liquid refractive index resolution of approximately 7.5x10(-4).


Assuntos
Polímeros , Refratometria/métodos , Processos Fotoquímicos , Polímeros/química
5.
Opt Express ; 17(3): 1970-5, 2009 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-19189027

RESUMO

Hybrid sol-gel planar optics devices for astronomy are produced for the first time. This material system can operate from the visible (0.5 microm) up to the edge of astronomical J-band (1.4 microm). The design, fabrication and characterization results of a coaxial three beam combiner are given as an example. Fringe contrasts above 94% are obtained with a source with spectral bandwidth of 50 nm. These results demonstrate that hybrid sol-gel technology can produce devices with high quality, opening the possibility of rapid prototyping of new designs and concepts for astronomical applications.

SELEÇÃO DE REFERÊNCIAS