Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Sci Rep ; 13(1): 15340, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37714924

RESUMO

Pressure recovery (PR) is essential part of the post stenotic fluid mechanics and depends on the ratio of EOA/AA, the effective aortic valve orifice area (EOA) and aortic cross-sectional area (AA). In patients with advanced ascending aortic aneurysm and mildly diseased aortic valves, the effect of AA on pressure recovery and corresponding functional aortic valve opening area (ELCO) was evaluated before and after valve-sparing surgery (Dacron graft implantation). 66 Patients with ascending aortic aneurysm (mean aortic diameter 57 +/- 10 mm) and aortic valve-sparing surgery (32 reimplantation technique (David), 34 remodeling technique (Yacoub)) were routinely investigated by Doppler echocardiography. Dacron graft with a diameter between 26 and 34 mm were implanted. EOA was significantly declined after surgery (3.4 +/- 0.8 vs. 2.6 +/- 0.9cm2; p < 0.001). Insertion of Dacron prosthesis resulted in a significant reduction of AA (26.7 +/- 10.2 vs. 6.8 +/- 1.1cm2; p < 0.001) with increased ratio of EOA/AA (0.14 +/- 0.05 vs. 0.40 +/- 0.1; p < 0.001) and pressure recovery index (PRI; 0.24 +/- 0.08 vs. 0.44 +/- 0.06; p < 0.0001). Despite reduction of EOA, ELCO (= EOA corrected for PR) increased from 4.0 +/- 1.1 to 5.0 +/- 3.1cm2 (p < 0.01) with reduction in transvalvular LV stroke work (1005 +/- 814 to 351 +/- 407 mmHg × ml, p < 0.001) after surgery. These effects were significantly better in patients with Yacoub technique than with the David operation. The hemodynamic findings demonstrate a valve-vessel interaction almost entirely caused by a marked reduction in the ascending AA with significant PR gain. The greater hemodynamic benefit of the Yacoub technique due to higher EOA values compared to the David technique was evident and may be of clinical relevance.


Assuntos
Aorta Torácica , Valva Aórtica , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Polietilenotereftalatos , Catéteres , Aorta/diagnóstico por imagem , Aorta/cirurgia
2.
Echocardiography ; 40(10): 1058-1067, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37638407

RESUMO

BACKGROUND: The importance of pulmonary artery pressure recovery (PR) in patients with Ross procedures in whom a homograft substitutes the resected pulmonary valve, is unknown. The aim of the study was to evaluate the occurrence and extent of PR in the pulmonary artery in 65 asymptomatic patients with pulmonary homograft after Ross surgery during rest and exercise. METHODS: Stress echocardiography was performed in 65 pulmonary homograft patients and 31 controls with native pulmonary valves up to 75 W. Right ventricular systolic pressure (RVSP), transvalvular flow, mean pressure gradient (Pmean ), valve resistance, and RV stroke work were determined in the exercise (max. 75 W) and recovery phases in increments of 25 W each. RESULTS: Pulmonary homografts demonstrated significantly elevated Pmean compared to controls at all stages. When considering pressure recovery (absolute and relative PR at rest 3.8 ± 1.8 mm Hg, 42.6 ± 7.2%, respectively) and transvalvular energy loss (EL; at rest 4.5 ± 4.3 mm Hg) the homograft hemodynamics reached the level of controls. In a subgroup of patients with tricuspid regurgitation, resting RVSP was the same in homograft patients and controls (21.3 ± 6.1 vs. 20.4 ± 6.3, p = .62), despite significant different Pmax values. CONCLUSIONS: Ross patients with pulmonary homograft showed systematically increased hemodynamic parameters compared to normal pulmonary valves. These differences were abolished when PR was considered for homograft patients. The equality of RVSP values at rest in both groups shows non-invasive evidence for PR in the pulmonary system after homograft implantation. Therefore, PR appears to be an important measure in calculating the actual hemodynamics in pulmonary homografts.

3.
Physiol Rep ; 10(23): e15432, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36511522

RESUMO

Relevant pressure recovery (PR) has been shown to increase functional stenotic aortic valve orifice area and reduce left ventricular load. However, little is known about the relevance of PR in the pulmonary artery. The study examined the impact of PR using 2D-echocardiography in the pulmonary artery distal to the degenerated homograft in patients after Ross surgery. Ninety-two patients with pulmonary homograft were investigated by Doppler echocardiography (mean time interval after surgery 31 ± 26 months). PR was measured as a function of pulmonary artery diameter determined by computed tomography angiography. Homograft orifice area, valve resistance, and transvalvular stroke work were calculated with and without considering PR. PR decreased as the pulmonary artery diameter increased (r = -0.69, p < 0.001). Mean PR was 41.5 ± 7.1% of the Doppler-derived pressure gradient (Pmax ), which resulted in a markedly increased homograft orifice area (energy loss coefficient index [ELCOI] vs. effective orifice area index [EOAI], 1.3 ± 0.4 cm2 /m2 vs. 0.9 ± 0.4 cm2 /m2 , p < 0.001). PR significantly reduced homograft resistance and transvalvular stroke work (822 ± 433 vs. 349 ± 220 mmHg × ml, p < 0.0001). When PR was considered, the correlations of the parameters used were significantly better, and 11 of 18 patients (61%) in the group with severe homograft stenosis (EOAI <0.6 cm2 /m2 ) could be reclassified as moderate stenosis. Our results showed that the Doppler measurements overestimated the degree of homograft stenosis and thus the right ventricular load, when PR was neglected in the pulmonary artery. Therefore, Doppler measurements that ignore PR can misclassify homograft stenosis and may lead to premature surgery.


Assuntos
Estenose da Valva Aórtica , Acidente Vascular Cerebral , Humanos , Constrição Patológica , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler
5.
J Am Coll Cardiol ; 77(17): 2204-2215, 2021 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-33926657

RESUMO

BACKGROUND: The randomized SOLVE-TAVI (compariSon of secOnd-generation seLf-expandable vs. balloon-expandable Valves and gEneral vs. local anesthesia in Transcatheter Aortic Valve Implantation) trial compared newer-generation self-expanding valves (SEV) and balloon-expandable valves (BEV) as well as local anesthesia with conscious sedation (CS) and general anesthesia (GA) in patients undergoing transfemoral transcatheter aortic valve replacement (TAVR). Both strategies showed similar outcomes at 30 days. OBJECTIVES: The purpose of this study was to compare clinical outcomes during 1-year follow-up in the randomized SOLVE-TAVI trial. METHODS: Using a 2 × 2 factorial design 447 intermediate- to high-risk patients with severe, symptomatic aortic stenosis were randomly assigned to transfemoral TAVR using either the SEV (Evolut R, Medtronic Inc., Minneapolis, Minnesota) or the BEV (Sapien 3, Edwards Lifesciences, Irvine, California) as well as CS or GA at 7 sites. RESULTS: In the valve-comparison strategy, rates of the combined endpoint of all-cause mortality, stroke, moderate or severe paravalvular leakage, and permanent pacemaker implantation were similar between the BEV and SEV group (n = 84, 38.3% vs. n = 87, 40.4%; hazard ratio: 0.94; 95% confidence interval: 0.70 to 1.26; p = 0.66) at 1 year. Regarding the anesthesia comparison, the combined endpoint of all-cause mortality, stroke, myocardial infarction, and acute kidney injury occurred with similar rates in the GA and CS groups (n = 61, 25.7% vs. n = 54, 23.8%; hazard ratio: 1.09; 95% confidence interval: 0.76 to 1.57; p = 0.63). CONCLUSIONS: In intermediate- to high-risk patients undergoing transfemoral TAVR, newer-generation SEV and BEV as well as CS and GA showed similar clinical outcomes at 1 year using a combined clinical endpoint. (SecOnd-generation seLf-expandable Versus Balloon-expandable Valves and gEneral Versus Local Anesthesia in TAVI [SOLVE-TAVI]; NCT02737150).


Assuntos
Anestesia/métodos , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Alemanha/epidemiologia , Humanos , Incidência , Masculino , Resultado do Tratamento
8.
Interact Cardiovasc Thorac Surg ; 32(1): 29-38, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33221839

RESUMO

OBJECTIVES: Recent mortality studies showed worse prognosis in patients (ARNS) with severe aortic regurgitation and preserved ejection fraction (EF) not fulfilling the criteria of current guidelines for surgery. The aim of our study was to analyse left ventricular (LV) systolic and diastolic function and mechanical energetics to find haemodynamic explanations for the reduced prognosis of these patients and to seek a new concept for surgery. METHODS: Global longitudinal strain (GLS) and echo-based single-beat pressure-volume analyses were performed in patients with ARNS (LV end-diastolic diameter <70 mm, EF >50%, GLS > -19% n = 41), with indication for surgery (ARS; n = 19) and in mild hypertensive controls (C; n = 20). Additionally, end-systolic elastance (LV contractility), stroke work and total energy (pressure-volume area) were calculated. RESULTS: ARNS demonstrated significantly depressed LV contractility versus C: end-systolic elastance (1.58 ± 0.7 vs 2.54 ± 0.8 mmHg/ml; P < 0.001), despite identical EF (EF: 59 ± 6% vs 59 ± 7%). Accordingly, GLS was decreased [-15.7 ± 2.7% (n = 31) vs -21.2 ± 2.4%; P < 0.001], end-diastolic volume (236 ± 90 vs 136 ± 30 ml; P < 0.001) and diastolic operant stiffness were markedly enlarged, as were pressure-volume area and stroke work, indicating waste of energy. The correlation of GLS versus end-systolic elastance was good (r = -0.66; P < 0.001). ARNS and ARS patients demonstrated similar haemodynamic disorders, whereas only GLS was worse in ARS. CONCLUSIONS: ARNS patients almost matched the ARS patients in their haemodynamic and energetic deterioration, thereby explaining poor prognosis reported in literature. GLS has been shown to be a reliable surrogate for LV contractility, possibly overestimating contractility due to exhausted preload reserve in aortic regurgitation patients. GLS may outperform conventional echo parameters to predict more precisely the timing of surgery.


Assuntos
Insuficiência da Valva Aórtica/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda , Metabolismo Energético , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Volume Sistólico
9.
Circulation ; 142(15): 1437-1447, 2020 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-32819145

RESUMO

BACKGROUND: In clinical practice, local anesthesia with conscious sedation (CS) is performed in roughly 50% of patients undergoing transcatheter aortic valve replacement. However, no randomized data assessing the safety and efficacy of CS versus general anesthesia (GA) are available. METHODS: The SOLVE-TAVI (Comparison of Second-Generation Self-Expandable Versus Balloon-Expandable Valves and General Versus Local Anesthesia in Transcatheter Aortic Valve Implantation) trial is a multicenter, open-label, 2×2 factorial, randomized trial of 447 patients with aortic stenosis undergoing transfemoral transcatheter aortic valve replacement comparing CS versus GA. The primary efficacy end point was powered for equivalence (equivalence margin 10% with significance level 0.05) and consisted of the composite of all-cause mortality, stroke, myocardial infarction, infection requiring antibiotic treatment, and acute kidney injury at 30 days. RESULTS: The primary composite end point occurred in 27.2% of CS and 26.4% of GA patients (rate difference, 0.8 [90% CI, -6.2 to 7.8]; Pequivalence=0.015). Event rates for the individual components were as follows: all-cause mortality, 3.2% versus 2.3% (rate difference, 1.0 [90% CI, -2.9 to 4.8]; Pequivalence<0.001); stroke, 2.4% versus 2.8% (rate difference, -0.4 [90% CI, -3.8 to 3.8]; Pequivalence<0.001); myocardial infarction, 0.5% versus 0.0% (rate difference, 0.5 [90% CI, -3.0 to 3.9]; Pequivalence<0.001), infection requiring antibiotics 21.1% versus 22.0% (rate difference, -0.9 [90% CI, -7.5 to 5.7]; Pequivalence=0.011); acute kidney injury, 9.0% versus 9.2% (rate difference, -0.2 [90% CI, -5.2 to 4.8]; Pequivalence=0.0005). There was a lower need for inotropes or vasopressors with CS (62.8%) versus GA (97.3%; rate difference, -34.4 [90% CI, -41.0 to -27.8]). CONCLUSIONS: Among patients with aortic stenosis undergoing transfemoral transcatheter aortic valve replacement, use of CS compared with GA resulted in similar outcomes for the primary efficacy end point. These findings suggest that CS can be safely applied for transcatheter aortic valve replacement. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02737150.


Assuntos
Anestesia Geral , Anestesia Local , Estenose da Valva Aórtica/cirurgia , Sedação Consciente , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino
10.
J Crit Care Med (Targu Mures) ; 6(2): 120-123, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32426519

RESUMO

Very few reports exist on serious cardiac complications associated with intake of serotonin-noradrenaline reuptake inhibitors. This paper describes and discusses the case of a patient who ingested a dose of 17.5 g venlafaxine. She developed a full serotonergic syndrome leading to multi-organ failure, including refractory cardiovascular shock, which was managed by early implantation of an extracorporeal life support (ECLS) system as a bridging strategy. This intervention was successful and resulted in full recovery of the patient.

11.
Eur Heart J ; 41(20): 1890-1899, 2020 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-32049283

RESUMO

AIMS: Transcatheter aortic valve implantation (TAVI) has emerged as established treatment option in patients with symptomatic aortic stenosis. Technical developments in valve design have addressed previous limitations such as suboptimal deployment, conduction disturbances, and paravalvular leakage. However, there are only limited data available for the comparison of newer generation self-expandable valve (SEV) and balloon-expandable valve (BEV). METHODS AND RESULTS: SOLVE-TAVI is a multicentre, open-label, 2 × 2 factorial, randomized trial of 447 patients with aortic stenosis undergoing transfemoral TAVI comparing SEV (Evolut R, Medtronic Inc., Minneapolis, MN, USA) with BEV (Sapien 3, Edwards Lifesciences, Irvine, CA, USA). The primary efficacy composite endpoint of all-cause mortality, stroke, moderate/severe prosthetic valve regurgitation, and permanent pacemaker implantation at 30 days was powered for equivalence (equivalence margin 10% with significance level 0.05). The primary composite endpoint occurred in 28.4% of SEV patients and 26.1% of BEV patients meeting the prespecified criteria of equivalence [rate difference -2.39 (90% confidence interval, CI -9.45 to 4.66); Pequivalence = 0.04]. Event rates for the individual components were as follows: all-cause mortality 3.2% vs. 2.3% [rate difference -0.93 (90% CI -4.78 to 2.92); Pequivalence < 0.001], stroke 0.5% vs. 4.7% [rate difference 4.20 (90% CI 0.12 to 8.27); Pequivalence = 0.003], moderate/severe paravalvular leak 3.4% vs. 1.5% [rate difference -1.89 (90% CI -5.86 to 2.08); Pequivalence = 0.0001], and permanent pacemaker implantation 23.0% vs. 19.2% [rate difference -3.85 (90% CI -10.41 to 2.72) in SEV vs. BEV patients; Pequivalence = 0.06]. CONCLUSION: In patients with aortic stenosis undergoing transfemoral TAVI, newer generation SEV and BEV are equivalent for the primary valve-related efficacy endpoint. These findings support the safe application of these newer generation percutaneous valves in the majority of patients with some specific preferences based on individual valve anatomy.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
JACC Case Rep ; 2(14): 2151-2155, 2020 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-34317127

RESUMO

We present the case of a patient with granulomatous endocarditis of the mitral valve leading to severe valve stenosis caused by granulomatosis with polyangiitis. Endocarditis is a rare complication of granulomatosis with polyangiitis that may be misdiagnosed as infectious endocarditis or, as in our case, thrombotic lesions. (Level of Difficulty: Intermediate.).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...