Rev. Soc. Esp. Dolor ; 13(7): 475-480, oct.2006. tab
Artigo em Es | IBECS | ID: ibc-63986

RESUMO

Introducción: En la ultima década la resonancia magnética (RM) ha sido introducida como una herramienta rutinaria de diagnóstico clínico por imagen, siendo considerada como una prueba no invasiva y segura. Sin embargo se ha contraindicado su utilización en pacientes que poseen dispositivos electrónicos implantados, entre ellos neurostimuladores medulares y corticales. A diferencia del avance de la tecnología en neuroesti-mulación y su aplicación clínica, hay pocos estudios que avalen la seguridad de la RM en pacientes con neuroestimuladores implantados. Nuestra hipótesis es que la RM es un método diagnóstico seguro en los pacientes con neuroestimuladores implantados. Nuestro trabajo tiene como finalidad aportar más pruebas objetivas acerca de esta cuestión. Material y Métodos: Serie de 8 pacientes con neuroestimuladores implantados (ITRELL III modelo 7425, Medtronic) sometidos a 9 estudios de RM (1,5 T General Electric Sigma Excite) durante el 2005, siguiendo el protocolo de Liem van Dongen en los que se vigiló la aparición de efectos adversos relacionados, durante e inmediatamente después del estudio de imagen. Resultados: Durante los estudios de RM no se produjeron incidencias, ni efectos adversos, en ninguno de los casos, tanto en los que el estudio se realizó en zonas alejadas del implante del neuroestimulador, como en los que se realizó en la misma zona anatómica. Una vez concluido el estudio de RM no se objetivó ninguna referencia de los pacientes a sensaciones relacionadas con el calentamiento o interacción electromagnética de la RM con su neuroestimulador. Tampoco se produjo ningún fallo en la reprogramación de los neuroestimuladores, excepto en un caso en el que fue imposible reprogramar el neuroestimulador una vez concluido el estudio de RM. Conclusiones: Todo parece indicar que en la mayoría de los casos la RM puede ser aplicada de forma segura en pacientes con sistemas de neruroestimulación implantados, siguiendo el protocolo de Liem-van Dongen, pero al parecer existen determinadas circunstancias en las que no queda totalmente claro la fiabilidad de esta recomendación. En el caso de la paciente en la que no fue posible reprogramar su neuroestimulador después de la RM en nuestro estudio, pudiera haber ocurrido un fallo de batería, o bien un daño en el circuito electrónico del generador. El no haber podido examinar el generador con problemas, no nos permite establecer una sospecha fundada sobre el conjunto de hechos que pueden haber concurrido en la producción del fallo. En cualquier caso se impone la realización de más estudios para esclarecer de forma más fiable las condiciones seguras de realización de la RM en pacientes con neuroestimuladores implantados (AU)


Aims: Over the past decade, nuclear magnetic resonance imaging (MRI) has been introduced as a safe, non-invasive routine clinical diagnostic tool. However, its use has been contraindicated in patients with implanted electronic devices, such as motor cortex and spinal cord neurostimulators. Despite the rapid growth in neurostimulation technology and its clinical application, there have been few studies addressing the safety of performing MRI procedures in patients with implanted neurostimulators. Our hypothesis is that MRI is a safe diagnostic technique in patients with implanted neurostimulators. The aim of our study is to offer some objective proof towards this point. Methods: Eight patients with implanted neurostimulators (ITRELL III Model 7425, Medtronic) undergoing 9 MRI procedures (1,5 T General Electric Sigma Excite) in 2005 are presented, following the Liem van Dongen´s protocol, with a focus in the appearance of adverse effects, during and immediately after the imaging study. Results: During the MRI studies there were no overall adverse effects detected in any case, in those in which the scanning was performed on a location away from the site of the implanted neurostimulators, nor in those in which it was performed in the same anatomic region. Once the MRI study concluded, no patient reported any sensation of discomfort attributable to heating or the electromagnetic interaction of the MRI with the neurostimulators. Neither there was any failure in the neurostimulators rescheduling, except in one case in which it was impossible its reprogrammation once the study was completed. Conclusions: In general, all these investigations indicate that in most cases MRI can be performed safely in patients with implanted stimulators, following the Liem van Dongen´s protocol, but it seems that under some circumstances this recommendation is not completely reliable. In the case of our patient in which the neurostimulator was impossible to reschedule after the MRI, this may have been caused by a battery failure, or there could have been a breakup in the generator’s electronic circuit. As the generator could not be examined, a hypothesis about the train of events leading to its failure was not established. In any case more studies are desirable to reliably explain the safety conditions required for the performance of MRI in patients with implanted neurostimulators (AU)


Assuntos
Humanos , Espectroscopia de Ressonância Magnética/efeitos adversos , Estimulação Elétrica Nervosa Transcutânea , Eletrodos Implantados , Espectroscopia de Ressonância Magnética/métodos , Estimulação Elétrica Nervosa Transcutânea/métodos , Bloqueio Nervoso , Bloqueio Nervoso/métodos , Segurança de Equipamentos
10.
Fisioterapia (Madr., Ed. impr.) ; 24(1): 10-13, ene. 2002. tab, graf
Artigo em Es | IBECS | ID: ibc-10637

RESUMO

En el presente estudio se intenta poner de manifiesto la importancia que para el desarrollo de la Fisioterapia tiene alcanzar un nivel de evidencia científica adecuado en nuestras publicaciones; hemos hecho un análisis de dicho nivel de evidencia y hemos detectado un elevado porcentaje de publicaciones que no alcanzan un nivel óptimo para el desarrollo de una disciplina científica como la nuestra. En la clasificación, según el grado de evidencia científica, de un total de 99 artículos sobre dolor lumbar, obtenidos de las cinco revistas de Fisioterapia con mayor rigor científico en los últimos 10 años, se han obtenido los siguientes resultados: 26,3 por ciento grado A (al menos un ensayo randomizado y controlado), 24,2 por ciento grado B (estudios clínicos sin ensayos randomizados y controlados) y 49,5 por ciento grado C (opinión de expertos). (AU)


Assuntos
Medicina Baseada em Evidências/estatística & dados numéricos , Dor Lombar/reabilitação , Bibliometria , Especialidade de Fisioterapia