RESUMO
No disponible
Assuntos
Humanos , Masculino , Adulto , Síndrome de Sweet/diagnóstico , Doença de Crohn/complicações , Anticorpos Monoclonais Humanizados/uso terapêutico , Terapia Biológica/efeitos adversos , Diagnóstico Diferencial , Toxidermias/diagnósticoRESUMO
Sweet syndrome is a common extraintestinal manifestation in inflammatory bowel disease (IBD). In this research, a 42-year-old man case with colon Crohn's disease is been described. After failure with two anti-TNF therapies, in treatment with azathioprim, it was decided to start a therapeutic target change to Vedolizumab due to a severe outbreak refractory to corticosteroids. 24 hours after the infusion of the new drug, skin lesions appear along with leukocytes with neutrophilia, all suggestive of sweet syndrome later confirmed by histology. In this clinical case, the importance of knowing the possible side effects of recently commercialized drugs for IBD is shown, being this topic important for gastroenterologists due to the wide therapeutic arsenal that is becoming available for this pathology.
Assuntos
Anticorpos Monoclonais Humanizados/efeitos adversos , Doença de Crohn/complicações , Fármacos Gastrointestinais/efeitos adversos , Síndrome de Sweet/induzido quimicamente , Adulto , Anticorpos Monoclonais Humanizados/uso terapêutico , Doença de Crohn/tratamento farmacológico , Fármacos Gastrointestinais/uso terapêutico , Humanos , Masculino , Pele/patologiaRESUMO
BACKGROUND: Capsule endoscopy (CE) is the first-line investigation in cases of suspected Crohn's disease (CD) of the small bowel, but the factors associated with a higher diagnostic yield remain unclear. OBJECTIVE: Our aim is to develop and validate a scoring index to assess the risk of the patients in this setting on the basis of biomarkers. PATIENTS AND METHODS: Data on fecal calprotectin, C-reactive protein, and other biomarkers from a population of 124 patients with suspected CD of the small bowel studied by CE and included in a PhD study were used to build a scoring index. This was first used on this population (internal validation process) and after that on a different set of patients from a multicenter study (external validation process). RESULTS: An index was designed in which every biomarker is assigned a score. Three risk groups have been established (low, intermediate, and high). In the internal validation analysis (124 individuals), patients had a 10, 46.5, and 81% probability of showing inflammatory lesions in CE in the low-risk, intermediate-risk, and high-risk groups, respectively. In the external validation analysis, including 410 patients from 12 Spanish hospitals, this probability was 15.8, 49.7, and 80.6% for the low-risk, intermediate-risk, and high-risk groups, respectively. CONCLUSION: Results from the internal validation process show that the scoring index is coherent, and results from the external validation process confirm its reliability. This index can be a useful tool for selecting patients before CE studies in cases of suspected CD of the small bowel.
Assuntos
Endoscopia por Cápsula/métodos , Doença de Crohn/diagnóstico , Intestino Delgado/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/análise , Proteína C-Reativa/análise , Endoscopia por Cápsula/efeitos adversos , Criança , Pré-Escolar , Fezes/química , Feminino , Humanos , Complexo Antígeno L1 Leucocitário/análise , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade , Adulto JovemRESUMO
No disponible
Assuntos
Humanos , Hemorragia Gastrointestinal/complicações , Hemorragia Gastrointestinal/diagnóstico por imagem , Enteropatias/induzido quimicamente , Anti-Inflamatórios não Esteroides/efeitos adversos , Fatores de Risco , Constrição Patológica/complicações , Diagnóstico Diferencial , Doença de Crohn/diagnóstico por imagem , Estudos Retrospectivos , Hemorragia Gastrointestinal/prevenção & controleAssuntos
Anti-Inflamatórios não Esteroides/efeitos adversos , Endoscopia por Cápsula , Hemorragia Gastrointestinal/induzido quimicamente , Enteropatias/induzido quimicamente , Artrite/epidemiologia , Aspirina/efeitos adversos , Estudos de Casos e Controles , Clopidogrel , Comorbidade , Doença das Coronárias/epidemiologia , Feminino , Humanos , Enteropatias/diagnóstico por imagem , Modelos Logísticos , Masculino , Análise Multivariada , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Bomba de Prótons/efeitos adversos , Inibidores da Bomba de Prótons/uso terapêutico , Estudos Retrospectivos , Fatores de Risco , Ticlopidina/efeitos adversos , Ticlopidina/análogos & derivadosRESUMO
INTRODUCCIÓN Y OBJETIVO: la capsula endoscópica y la enteroscopia de doble balón son técnicas de reconocido valor en el estudio de la hemorragia digestiva media, habiendo numerosos factores que pueden afectar a su rendimiento diagnóstico. El objetivo del presente estudio es el de caracterizar y definir los niveles de concordancia entre ambas focalizando en el tipo de lesión, en una gran cohorte de pacientes de un centro de referencia. MATERIAL Y MÉTODO: entre los años 2004-2014 se administraron 1.209 cápsulas en 1.078 pacientes y se realizaron 381 enteroscopias en 361 pacientes con hemorragia digestiva media. RESULTADOS: en 332 pacientes (edad media: 65,22 ± 15,41, 183 hombres) se realizaron ambos procedimientos. Ambas técnicas tuvieron un rendimiento diagnóstico similar (70,5% vs. 69,6%, p = 0,9). El rendimiento diagnóstico global de la enteroscopia fue superior en pacientes con una cápsula previa positiva (79,3% vs. 27,9%, p < 0,001). La concordancia diagnóstica entre los resultados por cápsula y enteroscopia para cada lesión fue muy buena para pólipos (0,89 [95% IC: 0,78-0,99]), buena en las lesiones vasculares (0,66 [95% IC: 0,55-0,77]), tumores (0,66 [95% IC: 0,55-0,76]) y moderada para úlceras (0.56 [95% IC: 0,46-0,67]). Los divertículos (0,39 [95% IC: 0,29-0,5] tuvieron una concordancia razonable. Los resultados entre ambos procedimientos difirieron en 73 pacientes (22%). CONCLUSIONES: el presente estudio evidencia que aunque el rendimiento de la cápsula endoscópica y la enteroscopia de doble balón de forma global sean similares, hay numerosos factores que pueden modificar estos valores, siendo el principal el tipo de lesión
BACKGROUND AND AIM: Capsule endoscopy and doubleballoon enteroscopy are well-recognized procedures in obscure gastrointestinal bleeding, with many factors that may influence their diagnosis yield. The aim of the present study was to characterize the degree of agreement between both techniques with focus on the type of lesion in a large cohort of patients at a referral center. MATERIAL AND METHOD: One thousand two hundred and nine capsules were administered in 1,078 patients and 381 enteroscopies were performed in 361 patients with obscure-gastrointestinal bleeding from 2004 to 2014. RESULTS: Both procedures were carried out in 332 patients (mean age: 65.22 ± 15.41, 183 men) and they have a similar diagnosis yield (70.5% vs. 69.6%, p = 0.9). Overall enteroscopy diagnosis yield was higher within patients with a previous positive capsule endoscopy (79.3% vs. 27.9%, p < 0.001). The degree of agreement was very good for polyps (0.89 [95% CI: 0.78-0.99]), good for vascular lesions (0.66 [95% CI: 0.55-0.77]) and tumors (0.66 [95% CI: 0.55-0.76]) and moderate for ulcers (0.56 [95% CI: 0.46-0.67]). Diverticula (0.39 [95% CI: 0.29-0.5]) achieved a fair agreement. The results of CE and DBE differed in 73 patients (22%). CONCLUSIONS: The present study confirms that although overall diagnostic yield by capsule endoscopy and double-balloon enteroscopy is similar, there are many factors which can modify these values, mainly the type of lesion
Assuntos
Feminino , Humanos , Masculino , Enteroscopia de Duplo Balão/instrumentação , Hemorragia Gastrointestinal/sangue , Cápsulas Endoscópicas/normas , Doença de Crohn/metabolismo , Doença de Crohn/patologia , Úlcera/complicações , Úlcera/mortalidade , Piloro/anormalidades , Piloro/lesões , Anestesia/métodos , Enteroscopia de Duplo Balão/métodos , Hemorragia Gastrointestinal/genética , Cápsulas Endoscópicas , Doença de Crohn/complicações , Doença de Crohn/diagnóstico , Úlcera/genética , Úlcera/patologia , Piloro/citologia , Piloro/patologia , AnestesiaRESUMO
No disponible
Assuntos
Feminino , Humanos , Masculino , Intussuscepção/metabolismo , Intussuscepção/patologia , Doença Celíaca/patologia , Anemia/sangue , Anemia/metabolismo , Anemia Ferropriva/sangue , Anemia Ferropriva/diagnóstico , Intussuscepção/complicações , Intussuscepção/diagnóstico , Doença Celíaca/complicações , Anemia/complicações , Anemia/diagnóstico , Anemia Ferropriva/genética , Anemia Ferropriva/metabolismoRESUMO
BACKGROUND AND AIM: Capsule endoscopy and double balloon enteroscopy are well-recognized procedures in obscure gastrointestinal bleeding, with many factors that may influence their diagnosis yield. The aim of the present study was to characterize the degree of agreement between both techniques with focus on the type of lesion in a large cohort of patients at a referral center. MATERIAL AND METHOD: One thousand two hundred and nine capsules were administered in 1,078 patients and 381 enteroscopies were performed in 361 patients with obscure-gastrointestinal bleeding from 2004 to 2014. RESULTS: Both procedures were carried out in 332 patients (mean age: 65.22 +/- 15.41, 183 men) and they have a similar diagnosis yield (70.5% vs. 69.6%, p = 0.9). Overall enteroscopy diagnosis yield was higher within patients with a previous positive capsule endoscopy (79.3% vs. 27.9%, p < 0.001). The degree of agreement was very good for polyps (0.89 [95% CI: 0.78-0.99]), good for vascular lesions (0.66 [95% CI: 0.55-0.77]) and tumors(0.66 [95% CI: 0.55-0.76]) and moderate for ulcers (0.56 [95% CI: 0.46-0.67]). Diverticula (0.39 [95% CI: 0.29-0.5]) achieved a fair agreement. The results of CE and DBE differed in 73 patients (22%). CONCLUSIONS: The present study confirms that although overall diagnostic yield by capsule endoscopy and double-balloon enteroscopy is similar, there are many factors which can modify these values, mainly the type of lesion.
Assuntos
Endoscopia por Cápsula , Enteroscopia de Duplo Balão , Hemorragia Gastrointestinal/etiologia , Adulto , Idoso , Feminino , Hemorragia Gastrointestinal/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Centros de Atenção TerciáriaAssuntos
Doença Celíaca/diagnóstico por imagem , Intussuscepção/etiologia , Doenças do Jejuno/etiologia , Adulto , Endoscopia por Cápsula , Doença Celíaca/complicações , Enteroscopia de Duplo Balão , Feminino , Humanos , Intussuscepção/diagnóstico por imagem , Doenças do Jejuno/diagnóstico por imagem , Tomografia Computadorizada por Raios XRESUMO
BACKGROUND AND AIM: There are few data concerning emergency double-balloon enteroscopy (DBE) and its usefulness in the management of severe acute obscure gastrointestinal bleeding (OGIB). The aim of this retrospective study was to evaluate emergency DBE and capsule endoscopy (CE) in patients with overt OGIB, analyzing the feasibility of this combined approach. METHODS: Emergency DBE in patients with overt OGIB was defined as performance within 24 h of symptom onset. We reported 27 patients (16 men, mean age: 64.6 ± 17.9 years) with overt severe bleeding who underwent 29 emergency DBE (22 anterograde, 7 retrograde). Of 27 patients, 16 (59.3%) underwent CE with real time (RT) viewing. RESULTS: Patients were diagnosed with the following: Dieulafoy's lesion (DL; n = 11, 40.7%), angioectasia (n = 7, 25.9%), tumors (n = 4, 14.8%), diverticulum (n = 3, 11.1%), ulcers (n = 2, 7.4%). We diagnosed 23 lesions amenable to endoscopic hemostasis and successfully treated 21 of them (77.8%). DL detection rate was statistically higher in the emergency DBE group than in OGIB patients with DBE done 24 h after symptom onset (40.7% vs 0.9%, respectively, P < 0.001). Combined approach with RT viewing by CE correctly modified DBE management in four patients (25%). CONCLUSIONS: Emergency DBE is feasible, safe and effective in acute OGIB and may avoid major surgery, diagnosing and successfully treating most patients. Combined approach with RT viewing by CE is especially useful to identify recurrent bleeding vascular lesions such as DL that may be easily misdiagnosed by non-emergency DBE.