Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(9)2023 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-37177520

RESUMO

Restorers and curators in museums sometimes find it difficult to accurately segment areas of paintings that have been contaminated with other pigments or areas that need to be restored, and work on the painting needs to be carried out with minimum possible damage. It is therefore necessary to develop measurement systems and methods that facilitate this task in the least invasive way possible. The aim of this study was to obtain high-dynamic-range (HDR) spectral reflectance and spatial resolution for Dalí's painting entitled Two Figures (1926) in order to segment a small area of black and white pigment that was affected by the contact transfer of reddish pigment from another painting. Using Hypermatrixcam to measure the HDR spectral reflectance developed by this research team, an HDR multispectral cube of 12 images was obtained for the band 470-690 nm in steps of 20 nm. With the values obtained for the spectral reflectance of the HDR cube, the colour of the area of paint affected by the transfer was studied by calculating the a*b* components with the CIELab system. These a*b* values were then used to define two methods of segmenting the exact areas in which there was a transfer of reddish pigment. The area studied in the painting was originally black, and the contamination with reddish pigment occupied 13.87% to 32% of the total area depending on the selected method. These different solutions can be explained because the lower limit is segmentation based on pure pigment and the upper limit considers red as an exclusion of non-black pigment. Over- and under-segmentation is a common problem described in the literature related to pigment selection. In this application case, as red pigment is not original and should be removed, curators will choose the method that selects the highest red area.

2.
Heliyon ; 8(11): e11877, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36439736

RESUMO

Nowadays, fog is still a natural phenomenon that hinders our ability to detect targets, particularly in the field of driving where accidents are increasing. In the literature we find different studies determining the range of visibility, improving the quality of an image, determining the characteristics of fog, etc. In this work we propose the possibility of using a structured lighting system, on which we project the light towards the target, limiting the field lighting. We have developed a scattering light propagation model to simulate and subsequently study the veil luminance, generated by backscattering, to predict the decrease in visibility. This simulation considers the type of fog, the relative orientation of various elements (observer, light source and targets). We have built a fog chamber to validate the experimental params of the described system. The results obtained from both the simulation and the experimental measurements demonstrate that it is possible to obtain a high contrast enhancement for viewing a target when illuminated as described. Clearly, this kind of lighting technology will improve the road safety in foggy night environments. The results of this work can also be extrapolated to any situation in which the visibility of an observer is compromised by the environment, such as heavy rain, smoke from fires, among others.

3.
Sensors (Basel) ; 22(13)2022 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-35808165

RESUMO

Commercial hyperspectral imaging systems typically use CCD or CMOS sensors. These types of sensors have a limited dynamic range and non-linear response. This means that when evaluating an artwork under uncontrolled lighting conditions and with light and dark areas in the same scene, hyperspectral images with underexposed or saturated areas would be obtained at low or high exposure times, respectively. To overcome this problem, this article presents a system for capturing hyperspectral images consisting of a matrix of twelve spectral filters placed in twelve cameras, which, after processing these images, makes it possible to obtain the high dynamic range image to measure the spectral reflectance of the work of art being evaluated. We show the developed system and describe all its components, calibration processes, and the algorithm implemented to obtain the high dynamic range spectral reflectance measurement. In order to validate the system, high dynamic range spectral reflectance measurements from Labsphere's Spectralon Reflectance Standards were performed and compared with the same reflectance measurements but using low dynamic range images. High dynamic range hyperspectral imaging improves the colorimetric accuracy and decreases the uncertainty of the spectral reflectance measurement based on low dynamic range imaging.

4.
Opt Express ; 29(17): 26287-26303, 2021 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-34615067

RESUMO

The absorption coefficient of a material is classically determined by measuring the transmittance of a homogeneous sample contained within flat optical faces and under collimated illumination. For arbitrary shapes this method is impracticable. The characterization of inhomogeneous or randomly distributed samples such as granules, powders or fibers suffers the same problem. Alternatively, an integrating cavity permits us to illuminate a sample under a homogenous and isotropic light field where the analysis simplifies. We revisit this strategy and present a new formal basis based on simple radiometric laws and principles. We introduce a new concept to describe the absorption: the optical form factor. We tackle a rigorous treatment of several regular forms, including full absorption range and the reflection at its surfaces. We also model and improve an integrating sphere setup to perform reliable measurements. Altogether, it permits achieving simple but general conclusions for samples with arbitrary shape or spatial distribution, from weak to highly absorbing, expanding the applicability of quantitative absorption spectroscopy. Finally, we validate it by measuring different sample formats made of PMMA: a cube, groups of granules and injection molding loose parts. The absorption coefficient of PMMA varies near three orders of magnitude in the explored range (380-1650 nm).

5.
Sci Rep ; 11(1): 15293, 2021 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-34315976

RESUMO

The optical absorption coefficient of culture media is critical for the survival analysis of pathogens under optical irradiation. The quality of the results obtained from experiments relies on the optical analysis of the spatial distribution of fluence which also depends on the geometry of the sample. In this contribution, we consider both the geometrical shape and the culture medium's absorption coefficient to evaluate how the spatial distribution of optical radiation affects pathogens/viruses. In this work, we exposed SARS-CoV-2 to UV-C radiation ([Formula: see text] = 254 nm) and we calculated-considering the influence of the optical absorption of the culture medium-a characteristic inactivation fluence of [Formula: see text] = 4.7 J/m2, or an equivalent 10% survival (D90 dose) of 10.8 J/m2. Experimentally, we diluted the virus into sessile drops of Dulbecco's Modified Eagle Medium to evaluate pathogen activity after controlled doses of UV irradiation. To validate the optical absorption mode, we carried out an additional experiment where we varied droplet size. Our model-including optical absorption and geometrical considerations-provides robust results among a variety of experimental situations, and represents our experimental conditions more accurately. These results will help to evaluate the capability of UV disinfecting strategies applied to a variety of everyday situations, including the case of micro-droplets generated by respiratory functions.


Assuntos
Absorção de Radiação , Meios de Cultura , SARS-CoV-2/fisiologia , SARS-CoV-2/efeitos da radiação , Raios Ultravioleta , Inativação de Vírus/efeitos da radiação , Desinfecção
6.
Opt Express ; 22 Suppl 6: A1538-46, 2014 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-25607310

RESUMO

Arrays of metallic thermocouples in the shape of spiral nanoantennas are proposed as infrared detectors, which use the thermoelectric properties of the metallic interfaces to generate electrical DC signals. The responsivity of these types of antennas is evaluated from both theoretical and numerical perspectives pointing out its potential as infrared sensors. Moreover, the same structures can be used to characterize the state of polarization of the optical near fields with a spatial resolution comparable to the wavelength.


Assuntos
Condutometria/instrumentação , Raios Infravermelhos , Nanopartículas Metálicas/química , Fotometria/instrumentação , Radiometria/instrumentação , Termografia/instrumentação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Nanopartículas Metálicas/efeitos da radiação , Modelos Teóricos , Nanotecnologia/instrumentação , Doses de Radiação , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Transdutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...