Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 159
Filtrar
1.
Acta Cardiol ; 79(6): 730-736, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38973431

RESUMO

BACKGROUND: In the present study, we evaluated whether DEFB1 gene polymorphisms are associated with the presence of coronary artery disease (CAD). METHODS: Two rs11362 A/G, and rs1800972 C/G gene polymorphisms of DEFB1 gene were genotyped by 5'exonuclease TaqMan assays in 219 patients with CAD and 522 control individuals. RESULTS: The distribution of rs1800972 C/G polymorphisms was similar in patients with CAD and healthy controls. Nonetheless, under the co-dominant, dominant, recessive, and additive models, the AA genotype of the rs11362 A/G polymorphism was associated with the risk of developing CAD (OR = 1.89 pCCo-Dom = 0.041, OR = 1.46, pCDom = 0.034, OR = 1.69, pCRes = 0.039, and OR = 1.37, pCAdd = 0.012, respectively). In addition, the linkage disequilibrium showed that the 'AG' haplotype was associated with an increased risk of developing CAD (OR = 1.23, p = 0.042). According, with the Genotype-Tissue Expression (GTEx) consortium data, the rs11362 AA genotype is associated with a low mRNA expression of the ß-defensin-1 in tissues, such as artery aorta, artery coronary, heart left ventricle, and heart atrial appendage (p < 0.001). CONCLUSION: This study demonstrates that rs11362 A/G polymorphism of the DEFB1 gene is involved in the risk of developing CAD, and with a low RNA expression of the ß-defensin-1 in heart tissue.


Assuntos
Doença da Artéria Coronariana , Predisposição Genética para Doença , Polimorfismo de Nucleotídeo Único , beta-Defensinas , Humanos , Doença da Artéria Coronariana/genética , Doença da Artéria Coronariana/diagnóstico , Feminino , Masculino , Pessoa de Meia-Idade , Estudos de Casos e Controles , beta-Defensinas/genética , Genótipo , Fatores de Risco , Idoso , Desequilíbrio de Ligação , DNA/genética , China/epidemiologia , Haplótipos
2.
Gac Med Mex ; 158(4): 216-221, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36256571

RESUMO

INTRODUCTION: In current European guidelines for the management of myocardial infarction after coronary stent placement, there is no consensus on dual antiplatelet therapy (DAPT) ideal duration to prevent stent thrombosis-restenosis without significantly increasing the bleeding risk. OBJECTIVE: To report the percentage of major bleeding and presence of major cardiovascular events associated with prolonged DAPT in patients recruited at the National Institute of Cardiology, treated with primary percutaneous coronary intervention and stent. METHODS: A longitudinal, prospective, observational, non-experimental, descriptive study was carried out. Patients were recruited from November 2016 to December 2017. RESULTS: One hundred and thirty-five patients with a mean age of 57 ± 10 years who completed the three-year follow-up were selected. Obesity and hypertension stood out as the main risk factors. After using DAPT for three years, 3.7% of mortality, 1.48% of major bleeding, and 4.4% of thrombosis-restenosis were recorded. CONCLUSIONS: Prolonged use of DAPT would be justified by the high incidence of thrombosis-restenosis, without a significant increase in bleeding risk, as well as a decrease in major cardiovascular events.


INTRODUCCIÓN: En las guías actuales europeas para el manejo del infarto de miocardio posterior a la colocación de endoprótesis coronaria (stent), no existe consenso sobre la duración ideal de la terapia antiagregante plaquetaria dual (DAPT, dual antiplatelet therapy) para prevenir la trombosis-reestenosis del stent sin aumentar el riesgo significativo de sangrado. OBJETIVO: Reportar el porcentaje de sangrado mayor y de eventos cardiovasculares mayores asociados a la DAPT prolongada en pacientes atendidos en el Instituto Nacional de Cardiología y tratados con intervención coronaria percutánea primaria y stent. MÉTODOS: Se realizó un estudio longitudinal, prospectivo observacional y descriptivo no experimental. Los pacientes fueron captados de noviembre de 2016 a diciembre de 2017. RESULTADOS: Fueron seleccionados 135 pacientes con una media de edad de 57 ± 10 años, quienes cumplieron un seguimiento clínico por tres años. La obesidad y la hipertensión destacaron como principales factores de riesgo. Posterior al uso de DAPT durante tres años, se registró 3.7 % de mortalidad, 1.48 % de sangrado mayor y 4.4 % de trombosis-reestenosis. CONCLUSIONES: El uso prolongado de DAPT estaría justificado por la alta incidencia de trombosis-reestenosis, sin incremento significativo en el riesgo de sangrado y con disminución de los eventos cardiovasculares mayores.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Trombose , Humanos , Pessoa de Meia-Idade , Idoso , Inibidores da Agregação Plaquetária/efeitos adversos , Stents Farmacológicos/efeitos adversos , Estudos Longitudinais , Estudos Prospectivos , Infarto do Miocárdio/epidemiologia , Stents/efeitos adversos , Hemorragia/epidemiologia , Trombose/complicações , Resultado do Tratamento
3.
Arch. cardiol. Méx ; 92(3): 334-341, jul.-sep. 2022. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1393828

RESUMO

Abstract Objective: We evaluated whether cholesteryl ester transfer protein (CETP) gene polymorphisms are associated with the presence of coronary artery disease (CAD) and/or restenosis in patients with coronary stent. Methods: Two polymorphisms of the CETP gene [−971 A/G (rs4783961), and Taq1B A/G (rs708272)] were genotyped by 5'exonuclease TaqMan assays in 219 patients with CAD (66 patients with restenosis and 153 without restenosis) and 607 control individuals. Results: The distribution of polymorphisms was similar in patients with and without restenosis. However, when the whole group of patients (with and without restenosis) was compared to healthy controls, under dominant model, the G allele of the Taq1B A/G polymorphism was associated with increased risk of CAD (odds ratio [OR] = 1.48, pCDom = 0.032). In the same way, under codominant, dominant, and additive models, the A allele of the −971 A/G polymorphisms was associated with an increased risk of developing CAD (OR = 2.03, pCCo-dom = 0.022, OR = 1.83, pCDom = 0.008, and OR = 1.39, pCAdd = 0.011, respectively). In addition, the linkage disequilibrium showed that the "AG" haplotype was associated with increased risk of developing CAD (OR = 1.28, p = 0.03). Conclusion: This study demonstrates that CETP Taq1B A/G and CETP −971 A/G polymorphisms are associated with an increased risk of developing CAD, but no association with restenosis was observed.


Resumen Objetivo: Evaluamos si los polimorfismos del gen CETP están asociados con la presencia de enfermedad arterial coronaria (EAC) y/o restenosis en pacientes con stent coronario. Métodos: En este estudio se genotiparon dos polimorfismos del gen CETP [−971 A/G (rs4783961) y Taq1B A/G (rs708272)] mediante ensayos de 5'exonucleasa TaqMan en 219 pacientes con EAC (66 pacientes con restenosis y 153 sin restenosis), y 607 individuos de control. Resultados: La distribución de polimorfismos fue similar en pacientes con y sin restenosis. Sin embargo, cuando se comparó todo el grupo de pacientes (con y sin restenosis) con controles sanos, bajo el modelo dominante el alelo G del polimorfismo Taq1B A/G se asocia con un mayor riesgo de EAC (OR = 1.48, pCDom = 0.032). De la misma manera, bajo los modelos co-dominante, dominante y aditivo, el alelo A de los polimorfismos −971 A/G se asocia con un mayor riesgo de desarrollar EAC (OR = 2.03, pCCo-dom = 0.022, OR = 1.83, pCDom = 0,008 y OR = 1.39, pCAdd = 0.011, respectivamente). Adicionalmente, el desequilibrio de ligamiento mostró que el haplotipo "AG" se asocia con un mayor riesgo de desarrollar EAC (OR = 1.28, p = 0.03). Conclusión: En resumen, este estudio demuestra que los polimorfismos CETP Taq1B A/G y CETP −971 A/G están asociados con un mayor riesgo de desarrollar CAD, pero no se observó asociación con restenosis.

4.
Gac. méd. Méx ; 158(4): 225-230, jul.-ago. 2022. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1404844

RESUMO

Resumen Introducción: En las guías actuales europeas para el manejo del infarto de miocardio posterior a la colocación de endoprótesis coronaria (stent), no existe consenso sobre la duración ideal de la terapia antiagregante plaquetaria dual (DAPT, dual antiplatelet therapy) para prevenir la trombosis-reestenosis del stent sin aumentar el riesgo significativo de sangrado. Objetivo: Reportar el porcentaje de sangrado mayor y de eventos cardiovasculares mayores asociados a la DAPT prolongada en pacientes atendidos en el Instituto Nacional de Cardiología y tratados con intervención coronaria percutánea primaria y stent. Métodos: Se realizó un estudio longitudinal, prospectivo observacional y descriptivo no experimental. Los pacientes fueron captados de noviembre de 2016 a diciembre de 2017. Resultados: Fueron seleccionados 135 pacientes con una media de edad de 57 ± 10 años, quienes cumplieron un seguimiento clínico por tres años. La obesidad y la hipertensión destacaron como principales factores de riesgo. Posterior al uso de DAPT durante tres años, se registró 3.7 % de mortalidad, 1.48 % de sangrado mayor y 4.4 % de trombosis-reestenosis. Conclusiones: El uso prolongado de DAPT estaría justificado por la alta incidencia de trombosis-reestenosis, sin incremento significativo en el riesgo de sangrado y con disminución de los eventos cardiovasculares mayores.


Abstract Introduction: In current European guidelines for the management of myocardial infarction after coronary stent placement, there is no consensus on dual antiplatelet therapy (DAPT) ideal duration to prevent stent thrombosis-restenosis without significantly increasing the bleeding risk. Objective: To report the percentage of major bleeding and presence of major cardiovascular events associated with prolonged DAPT in patients recruited at the National Institute of Cardiology, treated with primary percutaneous coronary intervention and stent. Methods: A longitudinal, prospective, observational, non-experimental, descriptive study was carried out. Patients were recruited from November 2016 to December 2017. Results: One-hundred and thirty-five patients with a mean age of 57 ± 10 years who completed the three-year follow-up were selected. Obesity and hypertension stood out as the main risk factors. After using DAPT for three years, 3.7% of mortality, 1.48% of major bleeding, and 4.4% of thrombosis-restenosis were recorded. Conclusions: Prolonged use of DAPT would be justified by the high incidence of thrombosis-restenosis, without a significant increase in bleeding risk, as well as a decrease in major cardiovascular events.

5.
High Blood Press Cardiovasc Prev ; 29(5): 463-468, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35904750

RESUMO

INTRODUCTION: The optimal anti-thrombotic therapy to prevent recurrent ischemic events in patients with acute coronary syndrome and coronary artery ectasia (CAE) remains unclear. AIM: To assess the efficacy and safety of antiplatelet plus anticoagulant therapy versus dual antiplatelet therapy in patients with acute coronary syndromes and coronary artery ectasia. METHODS: OVER-TIME is an investigator initiated, exploratory, open label, single center, randomized clinical trial comparing dual antiplatelet therapy (acetyl-salicylic acid plus a P2Y12 inhibitor) with the combination of an antiplatelet monotherapy (a P2Y12 inhibitor) plus a low dose anticoagulant (rivaroxaban, 15mg oral dose) for the prevention of recurrent ischemic events among patients with CAE. We aim to enroll approximately 60 patients with CAE and acute coronary syndromes. After recruitment, patients are randomized to (a) standard of care (dual antiplatelet regimen) or (b) the combination of antiplatelet monotherapy and low dose anticoagulant. Patients will be followed for at least 12 months. The OVER-TIME study aims to assess the efficacy of the regimen in prevention of major cardiovascular events and its security in bleeding events in acute coronary syndromes among patients with CAE. Expected results and conclusions: OVER-TIME is the first randomized controlled trial to assess different antithrombotic strategies in patients with CAE and acute coronary syndrome, and its results will offer preliminary data for the prevention of major cardiovascular events and bleeding events in this group of patients. TRIAL REGISTRATION NUMBER: NCT05233124 (ClinicalTrials.gov), date of registration: February 10, 2022.


Assuntos
Síndrome Coronariana Aguda , Intervenção Coronária Percutânea , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/tratamento farmacológico , Anticoagulantes/efeitos adversos , Vasos Coronários , Dilatação Patológica/induzido quimicamente , Dilatação Patológica/tratamento farmacológico , Quimioterapia Combinada , Fibrinolíticos/efeitos adversos , Hemorragia/induzido quimicamente , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Inibidores da Agregação Plaquetária/efeitos adversos , Rivaroxabana , Ácido Salicílico/uso terapêutico , Resultado do Tratamento
6.
Biomolecules ; 12(6)2022 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-35740890

RESUMO

In the present study, we evaluated the association of the BAT1, NFKBIL, LTA, and CASP1 single nucleotide polymorphisms and the gene−gene interactions with risk of developing restenosis after coronary stenting. The allele and genotype determination of the polymorphisms (BAT1 rs2239527 C/G, NFKBIL1 rs2071592 T/A, LTA rs1800683 G/A, CASP1 rs501192 A/G, and CASP1 rs580253 A/G) were performed by 5'exonuclease TaqMan assays in 219 patients: 66 patients with restenosis and 153 without restenosis. The distribution of rs2239527 C/G, rs2071592 T/A, and rs1800683 G/A polymorphisms was similar in patients with and without restenosis. Nonetheless, under recessive (OR = 2.73, pCRes = 0.031) and additive models (OR = 1.65, pCAdd = 0.039), the AA genotype of the rs501192 A/G polymorphism increased the restenosis risk. Under co-dominant, dominant, recessive, and additive models, the AA genotype of the rs580253 A/G was associated with a high restenosis risk (OR = 5.38, pCCo-Dom = 0.003; OR = 2.12, pCDom = 0.031; OR = 4.32, pCRes = 0.001; and OR = 2.16, 95%CI: 1.33−3.52, pCAdd = 0.001, respectively). In addition, we identified an interaction associated with restenosis susceptibility: BAT1-NFKBIL1-LTA-CASP1 (OR = 9.92, p < 0.001). In summary, our findings demonstrate that the rs501192 A/G and rs580253 A/G polymorphisms, as well as the gene−gene interactions between BAT1-NFKBIL1-LTA-CASP1, are associated with an increased restenosis risk after coronary stenting.


Assuntos
Caspase 1 , Reestenose Coronária , Predisposição Genética para Doença , Alelos , Caspase 1/genética , Reestenose Coronária/genética , Epistasia Genética , Humanos , Polimorfismo de Nucleotídeo Único
7.
Arch Cardiol Mex ; 92(3): 334-341, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34594055

RESUMO

OBJECTIVE: We evaluated whether cholesteryl ester transfer protein (CETP) gene polymorphisms are associated with the presence of coronary artery disease (CAD) and/or restenosis in patients with coronary stent. METHODS: Two polymorphisms of the CETP gene [-971 A/G (rs4783961), and Taq1B A/G (rs708272)] were genotyped by 5'exonuclease TaqMan assays in 219 patients with CAD (66 patients with restenosis and 153 without restenosis) and 607 control individuals. RESULTS: The distribution of polymorphisms was similar in patients with and without restenosis. However, when the whole group of patients (with and without restenosis) was compared to healthy controls, under dominant model, the G allele of the Taq1B A/G polymorphism was associated with increased risk of CAD (odds ratio [OR] = 1.48, pCDom = 0.032). In the same way, under codominant, dominant, and additive models, the A allele of the -971 A/G polymorphisms was associated with an increased risk of developing CAD (OR = 2.03, pCCo-dom = 0.022, OR = 1.83, pCDom = 0.008, and OR = 1.39, pCAdd = 0.011, respectively). In addition, the linkage disequilibrium showed that the "AG" haplotype was associated with increased risk of developing CAD (OR = 1.28, p = 0.03). CONCLUSION: This study demonstrates that CETP Taq1B A/G and CETP -971 A/G polymorphisms are associated with an increased risk of developing CAD, but no association with restenosis was observed.


OBJETIVO: Evaluamos si los polimorfismos del gen CETP están asociados con la presencia de enfermedad arterial coronaria (EAC) y/o restenosis en pacientes con stent coronario. MÉTODOS: En este estudio se genotiparon dos polimorfismos del gen CETP [−971 A/G (rs4783961) y Taq1B A/G (rs708272)] mediante ensayos de 5'exonucleasa TaqMan en 219 pacientes con EAC (66 pacientes con restenosis y 153 sin restenosis), y 607 individuos de control. RESULTADOS: La distribución de polimorfismos fue similar en pacientes con y sin restenosis. Sin embargo, cuando se comparó todo el grupo de pacientes (con y sin restenosis) con controles sanos, bajo el modelo dominante el alelo G del polimorfismo Taq1B A/G se asocia con un mayor riesgo de EAC (OR = 1.48, pCDom = 0.032). De la misma manera, bajo los modelos co-dominante, dominante y aditivo, el alelo A de los polimorfismos −971 A/G se asocia con un mayor riesgo de desarrollar EAC (OR = 2.03, pCCo-dom = 0.022, OR = 1.83, pCDom = 0,008 y OR = 1.39, pCAdd = 0.011, respectivamente). Adicionalmente, el desequilibrio de ligamiento mostró que el haplotipo "AG" se asocia con un mayor riesgo de desarrollar EAC (OR = 1.28, p = 0.03). CONCLUSIÓN: En resumen, este estudio demuestra que los polimorfismos CETP Taq1B A/G y CETP −971 A/G están asociados con un mayor riesgo de desarrollar CAD, pero no se observó asociación con restenosis.


Assuntos
Proteínas de Transferência de Ésteres de Colesterol , Doença da Artéria Coronariana , Proteínas de Transferência de Ésteres de Colesterol/genética , Doença da Artéria Coronariana/genética , Genótipo , Humanos , Desequilíbrio de Ligação , Polimorfismo de Nucleotídeo Único , Stents
8.
Arch Cardiol Mex ; 92(1): 36-41, 2022 01 03.
Artigo em Espanhol | MEDLINE | ID: mdl-34161313

RESUMO

Introduction: Heart failure (HF) is a chronic disease that acutely and progressively reduces physical functionality. The patient commonly suffers from intermittent relapses that increase the likelihood of comorbidities such as chronic insomnia, cognitive impairment, alterations in sexual response, psychological distress, symptoms of anxiety and depression disorder, and decreased self-care behaviors. The objective of this study was to identify the main needs for psychological support in patients with HF. Methodology: A descriptive, cross-sectional and analytical study was carried out. Participants were selected through consecutive non-probability samples. 150 patients with a diagnosis of HF who attended the Specialized Center for Heart Failure at the National Institute of Cardiology "Ignacio Chávez" were evaluated from November 2018 to April 2019, applying the inventories: Quality of life in patients with HF (Minnesota), Hospital Anxiety and Depression Scale (HADS), psychological distress thermometer (visual analog scale) and the HF Patient Information Needs Inventory. Results: 33% of the patients perceive a high level of psychological distress that requires immediate assistance and 26.6% report a medium level that requires monitoring. The main information needs reported by the patients were information on taking medications (53.7%) and managing psychological distress (43.9%). Conclusion: Active assessment of psychological distress and unmet information needs is relevant in patients with heart failure, thus highlighting the importance of their identification and the correct design and application of evidence-based interventions aimed at their resolution.


Introducción: La insuficiencia cardiaca crónica (ICC) es una enfermedad que reduce de manera aguda y progresiva la funcionalidad física. El paciente comúnmente sufre de recaídas intermitentes que aumentan la probabilidad de comorbilidades como insomnio crónico, deterioro cognitivo, alteraciones en la respuesta sexual, estrés psicológico, síntomas de trastorno de ansiedad y depresión y disminución de las conductas de autocuidado. Objetivo: Identificar las principales necesidades de apoyo psicológico en pacientes con IC. Metodología: Se realizó un estudio descriptivo, transversal y analítico. Se evaluaron 150 pacientes con ICC del Centro Especializado en Insuficiencia Cardiaca del Instituto Nacional de Cardiología Ignacio Chávez de noviembre de 2018 a abril de 2019. Se aplicaron los inventarios: Calidad de vida en pacientes con IC (Minnesota), Escala de Ansiedad y Depresión Hospitalaria (HADS), termómetro del distrés psicológico (escala analógica visual) y el Inventario de Necesidades de Información del Paciente con IC. Resultados: Treinta y tres por ciento de los pacientes perciben un nivel alto de distrés psicológico que requiere asistencia inmediata y el 26.6% reporta un nivel medio que requiere monitoreo. Las principales necesidades de información reportadas por los pacientes fueron información sobre la toma de medicamentos (53.7%) y manejo del estrés psicológico (43.9%). Conclusión: En pacientes con IC es relevante la valoración activa de distrés psicológico y necesidades de información no cubiertas, resaltando de este modo la importancia de su identificación y el correcto diseño y aplicación de intervenciones basadas en la evidencia enfocadas a su resolución.


Assuntos
Insuficiência Cardíaca , Transtornos Mentais , Angústia Psicológica , Disfunção Ventricular , Estudos Transversais , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Qualidade de Vida , Inquéritos e Questionários
9.
Arch Cardiol Mex ; 90(2): 142-147, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32897265

RESUMO

In this paper, we describe our coronary stent (INC-1) design and development, the way that we found the specific characteristics needed for our device including biophysics aspects, design, finite element testing, manufacturing, and mechanic trials, we submitted and animal models experiences. The stent platform was cobalt-chromium L605 (Co-Cr), with struts thickness of 80 µm, balloon expandable. We placed the coronary stent INC-1 on a rabbit and dog models so we can evaluate efficacy and security of the device in relationship to its biomechanical properties including navigation capacity, traceability, symmetric expansion, and safety, as well as endothelial attachment, thrombogenicity, and lack of involvement of secondary branches in these models. We succeeded in efficacy and safety of the device after fluoroscopy-guided implant proving excellent capacity of release system, traceability, fluoroscopic visualization, symmetric expansion, and complete endothelial attach. Furthermore, we obtained a good post-implant balloon withdrawal, functional integrity, and no vascular complications. We observed adequate clinical evolution 3 weeks after the stent implantation.


En esta publicación se describen el diseño y el desarrollo de un stent coronario (INC-1), la forma en que se determinaron las características biofísicas deseadas, el diseño y las pruebas computacionales por elemento finito, su fabricación, así como las pruebas mecánicas a las que se sometió el prototipo y por último las primeras experiencias en modelos animales. La plataforma del stent desarrollado fue de cobalto y cromo L605 (Co-Cr), con struts de 80 µm de grosor, expandido por balón. La colocación del stent coronario INC-1 se realizó en un modelo de conejo y uno canino con el objetivo de evaluar el éxito técnico y de seguridad del stent en relación con las propiedades biomecánicas (capacidad de navegación, maniobrabilidad, expansión simétrica del stent) y de seguridad (fijación a la pared vascular y ausencia de compromiso de ramas secundarias y formación de trombos en el momento de la colocación del stent en el modelo animal). Se obtuvo éxito técnico y de seguridad del stent después del implante guiado por fluoroscopia, lo que demostró adecuada capacidad del sistema liberador, excelente maniobrabilidad, adecuada visualización fluoroscópica, expansión simétrica y fijación completa a la pared vascular, capacidad para retirar el balón desinflado después del implante, e integridad funcional y sin complicaciones vasculares. La evolución clínica fue favorable a tres semanas del seguimiento planeado.


Assuntos
Vasos Coronários/cirurgia , Desenho de Prótese , Stents , Animais , Ligas de Cromo/química , Doença da Artéria Coronariana/cirurgia , Cães , Fluoroscopia , Humanos , Modelos Animais , Coelhos
10.
Gac Med Mex ; 156(4): 279-285, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32831335

RESUMO

INTRODUCTION: A drug-eluting coronary stent is being developed at the National Institute of Cardiology of Mexico for the treatment of ischemic heart disease. OBJECTIVE: To establish the best animal model for the tests, to show the advances in the drug-eluting stent prototype, to assess two drugs' antiproliferative activity and histological results. METHOD: Smooth muscle cell culture tests were performed in order to assess sirolimus and paclitaxel antiproliferative properties. The drugs were encapsulated inside the polymeric matrix of the stents. Rabbits and pigs were used as animal models. RESULTS: Sirolimus and paclitaxel showed an inhibitory effect, which was higher for the latter. Infrared spectroscopy and light and optical microscopy showed that the drug/polymer layer properly adhered to the stent. At a four-week follow-up, both animal models showed satisfactory clinical evolution and adequate histological response, although the porcine model was shown to be more suitable for future protocols. CONCLUSIONS: Preliminary tests of the drug-eluting stent provided bases for the development of a study protocol with an adequate number of pigs and with clinical angiographic and histopathological three-month follow-up.


INTRODUCCIÓN: En el Instituto Nacional de Cardiología de México se desarrolla una endoprótesis (stent) coronaria liberadora de fármacos para el tratamiento de la cardiopatía isquémica. OBJETIVO: Establecer el mejor modelo animal para las pruebas, mostrar los avances en el prototipo del stent liberador de fármacos, evaluar la actividad antiproliferativa de dos fármacos y los resultados histológicos. MÉTODO: Se realizaron cultivos de células de músculo liso para evaluar las propiedades antiproliferativas de sirolimus y paclitaxel. Los fármacos fueron encapsulados en el interior de la matriz polimérica de los stents. Se emplearon conejos y cerdos como modelos animales. RESULTADOS: Sirolimus y paclitaxel mostraron efecto inhibitorio, mayor en el segundo. La espectroscopia infrarroja y la microscopia óptica y electrónica mostraron que la capa del polímero con el fármaco se adhería adecuadamente al stent. A las cuatro semanas de seguimiento, ambos modelos animales mostraron evolución clínica satisfactoria y adecuada respuesta histológica, si bien el modelo porcino resultó más conveniente para protocolos futuros. CONCLUSIONES: Las pruebas preliminares del stent liberador de fármaco brindó bases para desarrollar el protocolo con un número adecuado en cerdos y con seguimiento clínico angiográfico e histopatológico a tres meses.


Assuntos
Stents Farmacológicos , Paclitaxel/administração & dosagem , Sirolimo/administração & dosagem , Animais , Modelos Animais de Doenças , Feminino , Seguimentos , Masculino , Microscopia , Desenho de Prótese , Coelhos , Espectrofotometria Infravermelho , Suínos
11.
Gac. méd. Méx ; 156(4): 276-282, Jul.-Aug. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1249911

RESUMO

Abstract Introduction: A drug-eluting coronary stent is being developed at the National Institute of Cardiology of Mexico for the treatment of ischemic heart disease. Objective: To establish the best animal model for the tests, to show the advances in the drug-eluting stent prototype, to assess two drugs’ antiproliferative activity and histological results. Method: Smooth muscle cell culture tests were performed in order to assess sirolimus and paclitaxel antiproliferative properties. The drugs were encapsulated inside the polymeric matrix of the stents. Rabbits and pigs were used as animal models. Results: Sirolimus and paclitaxel showed an inhibitory effect, which was higher for the latter. Infrared spectroscopy and light and optical microscopy showed that the drug/polymer layer properly adhered to the stent. At a four-week follow-up, both animal models showed satisfactory clinical evolution and adequate histological response, although the porcine model was shown to be more suitable for future protocols. Conclusions: Preliminary tests of the drug-eluting stent provided bases for the development of a study protocol with an adequate number of pigs and with clinical angiographic and histopathological three-month follow-up.


Resumen Introducción: En el Instituto Nacional de Cardiología de México se desarrolla una endoprótesis (stent) coronaria liberadora de fármacos para el tratamiento de la cardiopatía isquémica. Objetivo: Establecer el mejor modelo animal para las pruebas, mostrar los avances en el prototipo del stent liberador de fármacos, evaluar la actividad antiproliferativa de dos fármacos y los resultados histológicos. Método: Se realizaron cultivos de células de músculo liso para evaluar las propiedades antiproliferativas de sirolimus y paclitaxel. Los fármacos fueron encapsulados en el interior de la matriz polimérica de los stents. Se emplearon conejos y cerdos como modelos animales. Resultados: Sirolimus y paclitaxel mostraron efecto inhibitorio, mayor en el segundo. La espectroscopia infrarroja y la microscopia óptica y electrónica mostraron que la capa del polímero con el fármaco se adhería adecuadamente al stent. A las cuatro semanas de seguimiento, ambos modelos animales mostraron evolución clínica satisfactoria y adecuada respuesta histológica, si bien el modelo porcino resultó más conveniente para protocolos futuros. Conclusiones: Las pruebas preliminares del stent liberador de fármaco brindó bases para desarrollar el protocolo con un número adecuado en cerdos y con seguimiento clínico angiográfico e histopatológico a tres meses.


Assuntos
Animais , Masculino , Feminino , Coelhos , Paclitaxel/administração & dosagem , Sirolimo/administração & dosagem , Stents Farmacológicos , Desenho de Prótese , Espectrofotometria Infravermelho , Suínos , Seguimentos , Modelos Animais de Doenças , Microscopia
12.
Am Heart J ; 227: 31-39, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32668323

RESUMO

BACKGROUND: Lung ultrasound (LUS) has emerged as a new tool for the evaluation of congestion in heart failure (HF); incorporation of LUS during follow-up may detect congestion earlier and prompt interventions to prevent hospitalizations. The aim of this study was to test the hypothesis that the incorporation of LUS during follow-up of patients with HF may reduce the rate of adverse events compared with usual care. METHODS: In this single-blinded, randomized controlled trial, patients were randomized into an LUS-guided arm or control arm. Patients were followed in 4 prespecified visits during a 6-month period. LUS was performed in every patient visit in both groups; however, LUS results were available for the treating physician only in the LUS group. The primary outcome was the composite of urgent HF visits, rehospitalization for worsening HF, and death from any cause. RESULTS: One hundred twenty-six patients were randomized to either LUS (n = 63) or control (n = 63) (age 62.5 ±â€¯10 years, median left ventricular ejection fraction 31%). The primary end point occurred in 30 (47.6%) patients in the control group and 20 (31.7%) patients in the LUS group (P = .041). LUS-guided treatment was associated with a 45% risk reduction in the primary end point (hazard ratio 0.55, 95% CI 0.31-0.98, P = .044), mainly driven by a reduction in urgent HF visits (hazard ratio 0.28, 95% CI 0.13-0.62, P = .001). No significant differences in rehospitalizations for HF or death were found. CONCLUSIONS: Incorporation of LUS into clinical follow-up of patients with HF significantly reduced the risk of urgent visits for worsening HF.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Método Simples-Cego , Ultrassonografia/métodos
13.
Arch. cardiol. Méx ; 90(2): 142-147, Apr.-Jun. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1131023

RESUMO

Abstract In this paper, we describe our coronary stent (INC-1) design and development, the way that we found the specific characteristics needed for our device including biophysics aspects, design, finite element testing, manufacturing, and mechanic trials, we submitted and animal models experiences. The stent platform was cobalt-chromium L605 (Co-Cr), with struts thickness of 80 μm, balloon expandable. We placed the coronary stent INC-1 on a rabbit and dog models so we can evaluate efficacy and security of the device in relationship to its biomechanical properties including navigation capacity, traceability, symmetric expansion, and safety, as well as endothelial attachment, thrombogenicity, and lack of involvement of secondary branches in these models. We succeeded in efficacy and safety of the device after fluoroscopy-guided implant proving excellent capacity of release system, traceability, fluoroscopic visualization, symmetric expansion, and complete endothelial attach. Furthermore, we obtained a good post-implant balloon withdrawal, functional integrity, and no vascular complications. We observed adequate clinical evolution 3 weeks after the stent implantation.


Resumen En esta publicación se describen el diseño y el desarrollo de un stent coronario (INC-1), la forma en que se determinaron las características biofísicas deseadas, el diseño y las pruebas computacionales por elemento finito, su fabricación, así como las pruebas mecánicas a las que se sometió el prototipo y por último las primeras experiencias en modelos animales. La plataforma del stent desarrollado fue de cobalto y cromo L605 (Co-Cr), con struts de 80 μm de grosor, expandido por balón. La colocación del stent coronario INC-1 se realizó en un modelo de conejo y uno canino con el objetivo de evaluar el éxito técnico y de seguridad del stent en relación con las propiedades biomecánicas (capacidad de navegación, maniobrabilidad, expansión simétrica del stent) y de seguridad (fijación a la pared vascular y ausencia de compromiso de ramas secundarias y formación de trombos en el momento de la colocación del stent en el modelo animal). Se obtuvo éxito técnico y de seguridad del stent después del implante guiado por fluoroscopia, lo que demostró adecuada capacidad del sistema liberador, excelente maniobrabilidad, adecuada visualización fluoroscópica, expansión simétrica y fijación completa a la pared vascular, capacidad para retirar el balón desinflado después del implante, e integridad funcional y sin complicaciones vasculares. La evolución clínica fue favorable a tres semanas del seguimiento planeado.


Assuntos
Humanos , Animais , Cães , Coelhos , Desenho de Prótese , Stents , Vasos Coronários/cirurgia , Doença da Artéria Coronariana/cirurgia , Fluoroscopia , Ligas de Cromo/química , Modelos Animais
14.
Arch Med Res ; 51(5): 406-412, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32376040

RESUMO

BACKGROUND: PCI is an expensive procedure in our population and it implies a huge cost for the institutions and National Health Service. AIM OF THE STUDY: The main objective was to evaluate the technical and biological success of two stents designed in Mexico. METHODS: Ten York pigs, 4-6 months of age, underwent implantation of the bare metal INC-01 (10 stents) and INC-02 (6 stents) coronary stent in addition to a conventional commercial stent (10 stents). Technical success was evaluated immediately with angiography and Intravascular Ultrasound IVUS, continued by a mean follow-up of 4 month and a final angiographic, IVUS and histological evaluation. RESULTS: Initial technical success, angiography and IVUS between the three stents were not significant. One stent presented restenosis in follow-up (commercial stent), but all other stents presented excellent clinical outcome, satisfactory angiographic and IVUS results. Inflammation, proliferation and endothelialization between the stents had no major differences in histological analysis in a mean of 4 months follow-up. CONCLUSIONS: In this pig model, the INC 01 and INC 02 stents showed the same delivering technical success, angiographic and IVUS features, biological and histological response compared to commercial last generation stents.


Assuntos
Isquemia Miocárdica/cirurgia , Intervenção Coronária Percutânea/métodos , Stents/normas , Animais , Humanos , Metais , Pessoa de Meia-Idade , Suínos , Resultado do Tratamento
15.
Arch Cardiol Mex ; 90(2): 163-168, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32459214

RESUMO

In this paper we describe our coronary stent (INC-1) design and development, the way that we found the specific characteristics needed for our device including biophysics aspects, design, finite element testing, manufacturing and mechanic trials we submitted and animal models experiences. The stent platform was cobalt-chromium L605 (Co-Cr), with struts thickness of 80 µm, balloon expandable. We placed the coronary stent INC-1 on a rabbit and dog models so we can evaluate efficacy and security of the device in relationship to its biomechanical properties including navigation capacity, traceability, symmetric expansion and safety. As well as endothelial attachment, thrombogenicity and lack of involvement of secondary branches in these models. We succeeded in efficacy and safety of the device after fluoroscopy-guided implant proving excellent capacity of release system, traceability, fluoroscopic visualization, symmetric expansion and complete endothelial attach. Also, we obtained a good post-implant balloon withdrawal, functional integrity and no vascular complications. We observed adequate clinical evolution 3 weeks after the stent implantation.


En esta publicación se describen el diseño y el desarrollo de un stent coronario (INC-1), la forma en que se determinaron las características biofísicas deseadas, el diseño y las pruebas computacionales por elemento finito, su fabricación, así como las pruebas mecánicas a las que se sometió el prototipo y por último las primeras experiencias en modelos animales. La plataforma del stent desarrollado fue de cobalto y cromo L605 (Co-Cr), con struts de 80 µm de grosor, expandido por balón. La colocación del stent coronario INC-1 se realizó en un modelo de conejo y uno canino con el objetivo de evaluar el éxito técnico y de seguridad del stent en relación con las propiedades biomecánicas (capacidad de navegación, maniobrabilidad, expansión simétrica del stent) y de seguridad (fijación a la pared vascular y ausencia de compromiso de ramas secundarias y formación de trombos en el momento de la colocación del stent en el modelo animal). Se obtuvo éxito técnico y de seguridad del stent después del implante guiado por fluoroscopia, lo que demostró adecuada capacidad del sistema liberador, excelente maniobrabilidad, adecuada visualización fluoroscópica, expansión simétrica y fijación completa a la pared vascular, capacidad para retirar el balón desinflado después del implante, e integridad funcional y sin complicaciones vasculares. La evolución clínica fue favorable a tres semanas del seguimiento planeado.


Assuntos
Doença da Artéria Coronariana/cirurgia , Desenho de Prótese , Stents , Animais , Modelos Animais de Doenças , Cães , Fluoroscopia , Humanos , Coelhos
16.
Rev Invest Clin ; 72(1): 32-36, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32132738

RESUMO

BACKGROUND: The cost of performing a percutaneous coronary intervention is considerably high for the patient as well as for health systems, which have promoted the development of local technology to help meet the need for these devices. METHODS: The INC-01 bare-metal stent was developed at the National Institute of Cardiology in Mexico City and was first implanted on porcine models with technical success in 100% of the evaluated parameters. PRESENTATION OF CASES: We present the first three cases of patients with ischemic heart disease, to whom the INC-01 bare-metal stent was implanted. Intracoronary ultrasonography was performed post-stent implantation, showing all the characteristics of implant success during evaluation and clinical follow-up. CONCLUSIONS: Angiography and intracoronary ultrasound were carried out demonstrating that the INC-01 bare-metal stent has physical, biological, and histological characteristics similar to those found in commercial metallic stents.


Assuntos
Isquemia Miocárdica/cirurgia , Desenho de Prótese , Stents , Adulto , Idoso , Seguimentos , Humanos , Masculino , México , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/fisiopatologia , Projetos Piloto , Resultado do Tratamento , Ultrassonografia
17.
Rev Invest Clin ; 72(1): 19-24, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32132739

RESUMO

BACKGROUND: Previous studies have shown an association between polymorphisms of the BAT1-NF-κB inhibitor-like-1 (NFKBIL1)-LTA genomic region and susceptibility to myocardial infarction and acute coronary syndrome (ACS). OBJECTIVE: The objective of the study was to study the role of three polymorphisms in the BAT1, NFKBIL1, and LTA genes on the susceptibility or protection against ACS; we included a group of cases-controls from Central Mexico. METHODS: The BAT1 rs2239527C/G, NFKBIL1 rs2071592T/A, and LTA rs1800683G/A polymorphisms were genotyped using a 5' TaqMan assay in a group of 625 patients with ACS and 617 healthy controls. RESULTS: Under a recessive model, the BAT1 -23C/G (rs2239527) polymorphism showed an association with protection against ACS (odds ratio = 0.56, and p-corrected = 0.019). In contrast, the genotype and allele frequencies of the NFKBIL1 rs2071592T/A and LTA rs1800683G/A polymorphisms were similar between ACS patients and controls and no association was identified. CONCLUSION: Our data suggest an association between the BAT1 -23C/G polymorphism and protection against ACS in Mexican patients.


Assuntos
Síndrome Coronariana Aguda/genética , RNA Helicases DEAD-box/genética , Infarto do Miocárdio/genética , Proteínas Adaptadoras de Transdução de Sinal/genética , Idoso , Estudos de Casos e Controles , Feminino , Frequência do Gene , Predisposição Genética para Doença , Genótipo , Humanos , Linfotoxina-alfa/genética , Masculino , México , Pessoa de Meia-Idade , Polimorfismo de Nucleotídeo Único
18.
Arch. cardiol. Méx ; 90(1): 81-85, Jan.-Mar. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1131009

RESUMO

Abstract The prevalence of pregnancy in adolescent women is high in Mexico and represents a public health problem. The pregnant teenager with heart disease has a high probability of complications during pregnancy and the delivery, which carries a risk of death of both the mother and the product. In many cases the pregnancy should have been avoided, planned or interrupted, however the majority at this age is vulnerable and although certain cases must be interrupted by their high risk of maternal-fetal death, prevention and legal aspects should be considered. In some cases the woman wants a pregnancy although her health condition does not allow it, but there are options of adoption or recourse to a surrogate belly. In response to this growing social problem, the National Cardiology Institute Ignacio Chávez and National Institute of Perinatology, with the coordination of Ministry of Health in Mexico, started a pregnancy prevention module within a clinic of follow-up of cardiopathy and pregnancy. This review raises the global problem in our country that occupies the first place in pregnancies in adolescents, with more than 400,000 pregnancies a year and the form of immediate response in a multidisciplinary way.


Resumen La prevalencia de embarazo en mujeres adolescentes es muy alta en México, y representa un problema de salud pública. La adolescente embarazada con cardiopatía tiene altas posibilidades de complicaciones durante el embarazo y su resolución, lo que pone en riesgo la vida tanto de la madre como del producto. En muchos casos el embarazo debió ser evitado, planeado o interrumpido, sin embargo la mayoría a esta edad es vulnerable y si bien ciertos casos deben ser interrumpidos por su alto riesgo de muerte materno-fetal, es fundamental considerar la prevención y los aspectos legales. En algunos casos la mujer desea un embarazo aunque su condición de salud no se lo permite, pero existen opciones de adopción o recurrir a un vientre subrogado. Atendiendo este problema social cada vez más creciente, el Instituto Nacional de Cardiología Ignacio Chávez, en coordinación con la Comisión Coordinadora de la Secretaría de Salud y el Instituto Nacional de Perinatología, echaron a andar un módulo de prevención de embarazo dentro de una clínica de seguimiento de cardiopatía y embarazo. Esta revisión plantea el problema global en nuestro país, que ocupa el primer lugar en embarazos en adolescentes, con más de 400 mil embarazos al año y la forma de dar respuesta inmediata de manera multidisciplinaria.


Assuntos
Humanos , Feminino , Gravidez , Adolescente , Complicações Cardiovasculares na Gravidez/fisiopatologia , Gravidez na Adolescência , Cardiopatias/fisiopatologia , Prevalência , México
19.
Rev. invest. clín ; 72(1): 19-24, Jan.-Feb. 2020. tab
Artigo em Inglês | LILACS | ID: biblio-1251830

RESUMO

ABSTRACT Background: Previous studies have shown an association between polymorphisms of the BAT1-NF-κB inhibitor-like-1 (NFKBIL1)-LTA genomic region and susceptibility to myocardial infarction and acute coronary syndrome (ACS). Objective: The objective of the study was to study the role of three polymorphisms in the BAT1, NFKBIL1, and LTA genes on the susceptibility or protection against ACS; we included a group of cases-controls from Central Mexico. Methods: The BAT1 rs2239527C/G, NFKBIL1 rs2071592T/A, and LTA rs1800683G/A polymorphisms were genotyped using a 5' TaqMan assay in a group of 625 patients with ACS and 617 healthy controls. Results: Under a recessive model, the BAT1 -23C/G (rs2239527) polymorphism showed an association with protection against ACS (odds ratio = 0.56, and p-corrected = 0.019). In contrast, the genotype and allele frequencies of the NFKBIL1 rs2071592T/A and LTA rs1800683G/A polymorphisms were similar between ACS patients and controls and no association was identified. Conclusion: Our data suggest an association between the BAT1 -23C/G polymorphism and protection against ACS in Mexican patients.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , RNA Helicases DEAD-box/genética , Síndrome Coronariana Aguda/genética , Infarto do Miocárdio/genética , Estudos de Casos e Controles , Linfotoxina-alfa/genética , Predisposição Genética para Doença , Polimorfismo de Nucleotídeo Único , Proteínas Adaptadoras de Transdução de Sinal/genética , Frequência do Gene , Genótipo , México
20.
Rev. invest. clín ; 72(1): 32-36, Jan.-Feb. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1251832

RESUMO

ABSTRACT Background: The cost of performing a percutaneous coronary intervention is considerably high for the patient as well as for health systems, which have promoted the development of local technology to help meet the need for these devices. Methods: The INC-01 bare-metal stent was developed at the National Institute of Cardiology in Mexico City and was first implanted on porcine models with technical success in 100% of the evaluated parameters. Presentation of Cases: We present the first three cases of patients with ischemic heart disease, to whom the INC-01 bare-metal stent was implanted. Intracoronary ultrasonography was performed post-stent implantation, showing all the characteristics of implant success during evaluation and clinical follow-up. Conclusions: Angiography and intracoronary ultrasound were carried out demonstrating that the INC-01 bare-metal stent has physical, biological, and histological characteristics similar to those found in commercial metallic stents.


Assuntos
Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Desenho de Prótese , Stents , Isquemia Miocárdica/cirurgia , Projetos Piloto , Seguimentos , Ultrassonografia , Resultado do Tratamento , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/diagnóstico por imagem , México
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA