Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Radiat Res ; 55(5): 862-5, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24789085

RESUMO

The combination of automatic image acquisition and automatic image analysis of premature chromosome condensation (PCC) spreads was tested as a rapid biodosimeter protocol. Human peripheral lymphocytes were irradiated with (60)Co gamma rays in a single dose of between 1 and 20 Gy, stimulated with phytohaemaglutinin and incubated for 48 h, division blocked with Colcemid, and PCC-induced by Calyculin A. Images of chromosome spreads were captured and analysed automatically by combining the Metafer 4 and CellProfiler platforms. Automatic measurement of chromosome lengths allows the calculation of the length ratio (LR) of the longest and the shortest piece that can be used for dose estimation since this ratio is correlated with ionizing radiation dose. The LR of the longest and the shortest chromosome pieces showed the best goodness-of-fit to a linear model in the dose interval tested. The application of the automatic analysis increases the potential use of the PCC method for triage in the event of massive radiation causalities.


Assuntos
Bioensaio/métodos , Cromossomos Humanos/genética , Cromossomos Humanos/efeitos da radiação , Linfócitos/efeitos da radiação , Microscopia/métodos , Reconhecimento Automatizado de Padrão/métodos , Monitoramento de Radiação/métodos , Células Cultivadas , Cromossomos Humanos/ultraestrutura , Relação Dose-Resposta à Radiação , Humanos , Linfócitos/fisiologia , Linfócitos/ultraestrutura , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
J Radiat Res ; 54(5): 863-71, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23596200

RESUMO

The estimation of the dose and the irradiated fraction of the body is important information in the primary medical response in case of a radiological accident. The PCC-R assay has been developed for high-dose estimations, but little attention has been given to its applicability for partial-body irradiations. In the present work we estimated the doses and the percentage of the irradiated fraction in simulated partial-body radiation exposures at high doses using the PCC-R assay. Peripheral whole blood of three healthy donors was exposed to doses from 0-20 Gy, with 6°Co gamma radiation. To simulate partial body irradiations, irradiated and non-irradiated blood was mixed to obtain proportions of irradiated blood from 10-90%. Lymphocyte cultures were treated with Colcemid and Calyculin-A before harvest. Conventional and triage scores were performed for each dose, proportion of irradiated blood and donor. The Papworth's u test was used to evaluate the PCC-R distribution per cell. A dose-response relationship was fitted according to the maximum likelihood method using the frequencies of PCC-R obtained from 100% irradiated blood. The dose to the partially irradiated blood was estimated using the Contaminated Poisson method. A new D0 value of 10.9 Gy was calculated and used to estimate the initial fraction of irradiated cells. The results presented here indicate that by PCC-R it is possible to distinguish between simulated partial- and whole-body irradiations by the u-test, and to accurately estimate the dose from 10-20 Gy, and the initial fraction of irradiated cells in the interval from 10-90%.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas/efeitos da radiação , Análise Citogenética/métodos , Interpretação Estatística de Dados , Linfócitos/fisiologia , Linfócitos/efeitos da radiação , Contagem Corporal Total/métodos , Carga Corporal (Radioterapia) , Células Cultivadas , Relação Dose-Resposta à Radiação , Raios gama , Humanos , Linfócitos/citologia , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Irradiação Corporal Total/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA