Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
2.
Endosc Int Open ; 3(1): E7-E13, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26134777

RESUMO

INTRODUCTION: Adequate sedation is one of the cornerstones of good quality gastrointestinal endoscopy (GIE). Propofol sedation has increased significantly but there has been much debate over whether it can be administered by endoscopists. The aim of this prospective trial was to compare nonanesthesiologist-administered propofol (NAAP) and monitored anesthesia care (MAC). METHODS: A total of 2000 outpatients undergoing GIE at Hospital Albert Einstein (São Paulo, Brazil), a tertiary-care private hospital, were divided into two matched groups: NAAP (n = 1000) and MAC (n = 1000). In NAAP, propofol doses were determined by the endoscopist. A second physician stayed in the room during the entire procedure, according to local regulations. In MAC, the anesthesiologist administered propofol. RESULTS: In total, 1427 patients (71.3 %) were ASA (American Society of Anesthesiologists) class I and 573 were ASA class II. In NAAP, patients received more propofol + fentanyl (61.1 % vs. 50.5 %; P < 0.05) and there were fewer cases of deep sedation (44.7 % vs. 66.1 %; P < 0.05). Hypoxemia rates were similar (12.8 % for NAAP and 11.2 % for MAC; P = 0.3) but these reverted more rapidly in MAC (4.22 seconds vs. 7.26 seconds; P < 0.05). Agitation was more frequent in MAC (14.0 % vs. 5.6 %; P < 0.05). No later complications were observed. Patient satisfaction was very high and similar in both groups. CONCLUSION: In this setting, NAAP was as safe and effective as MAC for healthy patients undergoing GIE. Clinical trial ref. no.: U1111-1134-4430.

5.
HPB Surg ; 2012: 684172, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22619479

RESUMO

Objectives. Endoscopic management of bile leak after orthotopic liver transplant (OLT) is widely accepted. Preliminary studies demonstrated encouraging results for covered self-expandable metal stents (CSEMS) in complex bile leaks. Methods. Thirty-one patients with post-OLT bile leaks underwent endoscopic temporary placement of CSEMS (3 partially CSEMS , 18 fully CSEMS with fins and 10 fully CSEMS with flare ends) between December 2003 and December 2010. Long-term clinical success and safety were evaluated. Results. Median stent indwelling and follow-up were 89 and 1,353 days for PCSEMS, 102 and 849 for FCSEMS with fins and 98 and 203 for FCSEMS with flare ends. Clinical success was achieved in 100%, 77.8%, and 70%, respectively. Postplacement complications: cholangitis (1) and proximal migration (1), both in the FCSEMS with fins. Postremoval complications were biliary strictures requiring drainage: PCSEMS (1), FCSEMS with fins (6) and with flare ends (1). There was no significant differences in the FCSEMS groups regarding clinical success, age, gender, leak location, previous treatment, stent indwelling, and complications. Conclusion. Temporary placement of CSEMS is effective to treat post-OLT biliary leaks. However, a high number of post removal biliary strictures occurred especially in the FCSEMS with fins. CSEMS cannot be recommended in this patient population.

6.
World J Gastroenterol ; 16(6): 728-31, 2010 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-20135721

RESUMO

AIM: To assess the feasibility of endoscopic ultrasound (EUS)-guided celiac plexus neurolysis (CPN) using a poloxamer. METHODS: In this prospective evaluation, six Yorkshire pigs underwent EUS-guided CPN. Three received an injection of 10 mL of 0.25% Lidocaine plus methylene blue (group 1) and three received an injection of 10 mL of 0.25% Lidocaine plus blue colored poloxamer (PS137-25) (group 2). Necropsy was performed immediately after the animals were sacrificed. The abdominal and pelvic cavities were examined for the presence of methylene blue and the blue colored poloxamer. RESULTS: EUS-guided CPN was successfully performed in all 6 pigs without immediate complication. Methylene blue was identified throughout the peritoneal and retroperitoneal cavity in group 1. The blue colored poloxamer was found in the retroperitoneal cavity immediately adjacent to the aorta, in the exact location of the celiac plexus in group 2. CONCLUSION: EUS-guided CPN using a reverse phase polymer in a non-survival porcine model was technically feasible. The presence of a poloxamer gel at the site of the celiac plexus at necropsy indicates a precise delivery of the neurolytic agent.


Assuntos
Plexo Celíaco/diagnóstico por imagem , Endossonografia , Bloqueio Nervoso/métodos , Polímeros , Anestésicos Locais , Animais , Plexo Celíaco/fisiopatologia , Estudos de Viabilidade , Injeções , Lidocaína , Modelos Animais , Estudos Prospectivos , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA