Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Mass Spectrom ; 53(6): 476-503, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29524299

RESUMO

The number of substances nominally listed in the prohibited list of the World Anti-Doping Agency increases each year. Moreover, many of these substances do not have a single analytical target and must be monitored through different metabolites, artifacts, degradation products, or biomarkers. A new analytical method was developed and validated for the simultaneous analysis of peptides and organic molecules using a single sample preparation and LC-Q-HRMS detection. The simultaneous analysis of 450 target molecules was performed after cleanup on a mixed-mode solid-phase extraction cartridge, combined with untreated urine. The cleanup solvent and reconstitution solvent were the most important parameters for achieving a comprehensive sample preparation approach. A fast chromatographic run based on a multistep gradient was optimized under different flows; the detection of all substances without isomeric coelution was achieved in 11 minutes, and the chromatographic resolution was considered a critical parameter, even in high-resolution mass spectrometry detection. The mass spectrometer was set to operate by switching between positive and negative ionization mode for FULL-MS, all-ion fragmentation, and FULL-MS/MS2 . The suitable parameters for the curved linear trap (c-trap) conditions were determined and found to be the most important factors for the development of the method. Only FULL-MS/MS2 enables the detection of steroids and peptides at concentrations lower than the minimum required performance levels set by World Anti-Doping Agency (1 ng mL-1 ). The combination of the maximum injection time of the ions into the c-trap, multiplexing experiments, and loop count under optimized conditions enabled the method to be applied to over 10 000 samples in only 2 months during the 2016 Rio Summer Olympic and Paralympic Games. The procedure details all aspects, from sample preparation to mass spectrometry detection. FULL-MS data acquisition is performed in positive and negative ion mode simultaneously and can be applied to untargeted approaches.


Assuntos
Peptídeos/análise , Esteroides/análise , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Dopagem Esportivo/prevenção & controle , Humanos , Limite de Detecção , Peptídeos/urina , Extração em Fase Sólida/métodos , Esteroides/urina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...