Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Plants (Basel) ; 13(7)2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38611461

RESUMO

Olive quick decline syndrome (OQDS) is a devastating plant disease caused by the bacterium Xylella fastidiosa (Xf). Exploratory missions in the Salento area led to the identification of putatively Xf-resistant olive trees (putatively resistant plants, PRPs) which were pauci-symptomatic or asymptomatic infected plants belonging to different genetic clusters in orchards severely affected by OQDS. To investigate the defense strategies employed by these PRPs to contrast Xf infection, the PRPs were analyzed for the anatomy and histology of xylem vessels, patterns of Xf distribution in host tissues (by the fluorescent in situ hybridization technique-FISH) and the presence of secondary metabolites in stems. The xylem vessels of the PRPs have an average diameter significantly lower than that of susceptible plants for each annual tree ring studied. The histochemical staining of xylem vessels highlighted an increase in the lignin in the parenchyma cells of the medullary rays of the wood. The 3D images obtained from FISH-LSM (laser scanning microscope) revealed that, in the PRPs, Xf cells mostly appeared as individual cells or as small aggregates; in addition, these bacterial cells looked to be incorporated in the autofluorescence signal of gels and phenolic compounds regardless of hosts' genotypes. In fact, the metabolomic data from asymptomatic PRP stems showed a significant increase in compounds like salicylic acid, known as a signal molecule which mediates host responses upon pathogen infection, and luteolin, a naturally derived flavonoid compound with antibacterial properties and with well-known anti-biofilm effects. Findings indicate that the xylem vessel geometry together with structural and chemical defenses are among the mechanisms operating to control Xf infection and may represent a common resistance trait among different olive genotypes.

2.
Med Phys ; 51(6): 4489-4503, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38432192

RESUMO

BACKGROUND: The increasing use of complex and high dose-rate treatments in radiation therapy necessitates advanced detectors to provide accurate dosimetry. Rather than relying on pre-treatment quality assurance (QA) measurements alone, many countries are now mandating the use of in vivo dosimetry, whereby a dosimeter is placed on the surface of the patient during treatment. Ideally, in vivo detectors should be flexible to conform to a patient's irregular surfaces. PURPOSE: This study aims to characterize a novel hydrogenated amorphous silicon (a-Si:H) radiation detector for the dosimetry of therapeutic x-ray beams. The detectors are flexible as they are fabricated directly on a flexible polyimide (Kapton) substrate. METHODS: The potential of this technology for application as a real-time flexible detector is investigated through a combined dosimetric and flexibility study. Measurements of fundamental dosimetric quantities were obtained including output factor (OF), dose rate dependence (DPP), energy dependence, percentage depth dose (PDD), and angular dependence. The response of the a-Si:H detectors investigated in this study are benchmarked directly against commercially available ionization chambers and solid-state diodes currently employed for QA practices. RESULTS: The a-Si:H detectors exhibit remarkable dose linearities in the direct detection of kV and MV therapeutic x-rays, with calibrated sensitivities ranging from (0.580 ± 0.002) pC/cGy to (19.36 ± 0.10) pC/cGy as a function of detector thickness, area, and applied bias. Regarding dosimetry, the a-Si:H detectors accurately obtained OF measurements that parallel commercially available detector solutions. The PDD response closely matched the expected profile as predicted via Geant4 simulations, a PTW Farmer ionization chamber and a PTW ROOS chamber. The most significant variation in the PDD performance was 5.67%, observed at a depth of 3 mm for detectors operated unbiased. With an external bias, the discrepancy in PDD response from reference data was confined to ± 2.92% for all depths (surface to 250 mm) in water-equivalent plastic. Very little angular dependence is displayed between irradiations at angles of 0° and 180°, with the most significant variation being a 7.71% decrease in collected charge at a 110° relative angle of incidence. Energy dependence and dose per pulse dependence are also reported, with results in agreement with the literature. Most notably, the flexibility of a-Si:H detectors was quantified for sample bending up to a radius of curvature of 7.98 mm, where the recorded photosensitivity degraded by (-4.9 ± 0.6)% of the initial device response when flat. It is essential to mention that this small bending radius is unlikely during in vivo patient dosimetry. In a more realistic scenario, with a bending radius of 15-20 mm, the variation in detector response remained within ± 4%. After substantial bending, the detector's photosensitivity when returned to a flat condition was (99.1 ± 0.5)% of the original response. CONCLUSIONS: This work successfully characterizes a flexible detector based on thin-film a-Si:H deposited on a Kapton substrate for applications in therapeutic x-ray dosimetry. The detectors exhibit dosimetric performances that parallel commercially available dosimeters, while also demonstrating excellent flexibility results.


Assuntos
Radiometria , Silício , Radiometria/instrumentação , Hidrogênio , Dosimetria in Vivo , Terapia por Raios X/instrumentação , Humanos
3.
Talanta ; 273: 125866, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38490025

RESUMO

The global increase in population aging has led to a rise in neurodegenerative diseases (NDs), posing significant challenges to public health. Developing selective and specific biomarkers for early diagnosis and drug development is crucial addressing the growing burden of NDs. In this context, the RNA-binding protein TDP-43 has emerged as a promising biomarker for amyotrophic lateral sclerosis (ALS), frontotemporal lobar degeneration (FTLD), and TDP-43-associated proteinopathies. However, existing detection methods suffer from limitations such as cost, complexity, and operator dependence. Here, we present a novel electrochemical biosensor integrated into a lab-on-chip (LoC) platform to detect TDP-43. The sensor utilizes electrosynthesized polypyrrole derivatives with carboxylic groups for transducer functionalization, enabling targeted immobilization of TDP-43 antibodies. Differential pulsed voltammetry (DPV) is used for the indirect detection and quantification of TDP-43. The chip exhibits rapid response, good reproducibility, a linear detection range, and sensitivity from 0.01 ng/mL to 25 ng/mL of TDP-43 protein concentration with a LOD = 10 pg/mL. Furthermore, successful TDP-43 detection in complex matrices like serum of ALS patients and healthy individuals demonstrates its potential as a point-of-care diagnostic device. This electrochemical biosensor integrated into a chip offers good sensitivity, rapid response, and robust performance, providing a promising avenue for advancing neurodegenerative disease diagnostics and therapeutic development.


Assuntos
Esclerose Lateral Amiotrófica , Técnicas Biossensoriais , Doenças Neurodegenerativas , Humanos , Esclerose Lateral Amiotrófica/diagnóstico , Esclerose Lateral Amiotrófica/metabolismo , Polímeros , Reprodutibilidade dos Testes , Imunoensaio , Pirróis , Proteínas de Ligação a DNA/metabolismo , Biomarcadores/metabolismo
4.
Phys Med Biol ; 68(13)2023 06 28.
Artigo em Inglês | MEDLINE | ID: mdl-37267990

RESUMO

Objective. Microbeam radiation therapy (MRT) is an alternative emerging radiotherapy treatment modality which has demonstrated effective radioresistant tumour control while sparing surrounding healthy tissue in preclinical trials. This apparent selectivity is achieved through MRT combining ultra-high dose rates with micron-scale spatial fractionation of the delivered x-ray treatment field. Quality assurance dosimetry for MRT must therefore overcome a significant challenge, as detectors require both a high dynamic range and a high spatial resolution to perform accurately.Approach. In this work, a series of radiation hard a-Si:H diodes, with different thicknesses and carrier selective contact configurations, have been characterised for x-ray dosimetry and real-time beam monitoring applications in extremely high flux beamlines utilised for MRT at the Australian Synchrotron.Results. These devices displayed superior radiation hardness under constant high dose-rate irradiations on the order of 6000 Gy s-1, with a variation in response of 10% over a delivered dose range of approximately 600 kGy. Dose linearity of each detector to x-rays with a peak energy of 117 keV is reported, with sensitivities ranging from (2.74 ± 0.02) nC/Gy to (4.96 ± 0.02) nC/Gy. For detectors with 0.8µm thick active a-Si:H layer, their operation in an edge-on orientation allows for the reconstruction of micron-size beam profiles (microbeams). The microbeams, with a nominal full-width-half-max of 50µm and a peak-to-peak separation of 400µm, were reconstructed with extreme accuracy. The full-width-half-max was observed as 55 ± 1µm. Evaluation of the peak-to-valley dose ratio and dose-rate dependence of the devices, as well as an x-ray induced charge (XBIC) map of a single pixel is also reported.Significance. These devices based on novel a-Si:H technology possess a unique combination of accurate dosimetric performance and radiation resistance, making them an ideal candidate for x-ray dosimetry in high dose-rate environments such as FLASH and MRT.


Assuntos
Silício , Síncrotrons , Raios X , Austrália , Radiometria/métodos
5.
Biosens Bioelectron ; 231: 115271, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37060819

RESUMO

Current in-vitro 2D cultures and animal models present severe limitations in recapitulating human physiopathology with striking discrepancies in estimating drug efficacy and side effects when compared to human trials. For these reasons, microphysiological systems, organ-on-chip and multiorgans microdevices attracted considerable attention as novel tools for high-throughput and high-content research to achieve an improved understanding of diseases and to accelerate the drug development process towards more precise and eventually personalized standards. This review takes the form of a guide on this fast-growing field, providing useful introduction to major themes and indications for further readings. We start analyzing Organs-on-chips (OOC) technologies for testing the major drug administration routes: (1) oral/rectal route by intestine-on-a-chip, (2) inhalation by lung-on-a-chip, (3) transdermal by skin-on-a-chip and (4) intravenous through vascularization models, considering how drugs penetrate in the bloodstream and are conveyed to their targets. Then, we focus on OOC models for (other) specific organs and diseases: (1) neurodegenerative diseases with brain models and blood brain barriers, (2) tumor models including their vascularization, organoids/spheroids, engineering and screening of antitumor drugs, (3) liver/kidney on chips and multiorgan models for gastrointestinal diseases and metabolic assessment of drugs and (4) biomechanical systems recapitulating heart, muscles and bones structures and related diseases. Successively, we discuss technologies and materials for organ on chips, analyzing (1) microfluidic tools for organs-on-chips, (2) sensor integration for real-time monitoring, (3) materials and (4) cell lines for organs on chips. (Nano)delivery approaches for therapeutics and their on chip assessment are also described. Finally, we conclude with a critical discussion on current significance/relevance, trends, limitations, challenges and future prospects in terms of revolutionary impact on biomedical research, preclinical models and drug development.


Assuntos
Técnicas Biossensoriais , Dispositivos Lab-On-A-Chip , Animais , Humanos , Desenvolvimento de Medicamentos , Sistemas Microfisiológicos , Fígado
6.
Biosensors (Basel) ; 13(2)2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-36831963

RESUMO

In this work, we report the parametric optimization of surface acoustic wave (SAW) delay lines on Lithium niobate for environmental monitoring applications. First, we show that the device performance can be improved by acting opportunely on geometrical design parameters of the interdigital transducers such as the number of finger pairs, the finger overlap length and the distance between the emitter and the receiver. Then, the best-performing configuration is employed to realize SAW sensors. As aerosol particulate matter (PM) is a major threat, we first demonstrate a capability for the detection of polystyrene particles simulating nanoparticulates/nanoplastics, and achieve a limit of detection (LOD) of 0.3 ng, beyond the present state-of-the-art. Next, the SAW sensors were used for the first time to implement diagnostic tools able to detect Grapevine leafroll-associated virus 3 (GLRaV-3), one of the most widespread viruses in wine-growing areas, outperforming electrochemical impedance sensors thanks to a five-times better LOD. These two proofs of concept demonstrate the ability of miniaturized SAW sensors for carrying out on-field monitoring campaigns and their potential to replace the presently used heavy and expensive laboratory instrumentation.


Assuntos
Microplásticos , Som
7.
Materials (Basel) ; 16(4)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36837327

RESUMO

The removal of pollutants, such as heavy metals, aromatic compounds, dyes, pesticides and pharmaceuticals, from water is still an open challenge. Many methods have been developed and exploited for the purification of water from contaminants, including photocatalytic degradation, biological treatment, adsorption and chemical precipitation. Absorption-based techniques are still considered among the most efficient and commonly used approaches thanks to their operational simplicity. In recent years, polydopamine-coated magnetic nanoparticles have emerged for the uptake of heavy metals in water treatment, since they combine specific affinity towards pollutants and magnetic separation capacity. In this context, this work focuses on the synthesis of polydopamine (PDA)-coated Super Paramagnetic Iron Oxide Nanoparticles (PDA@SPIONs) as adsorbents for Cu2+ ions, designed to serve as functional nanostructures for the removal of Cu2+ from water by applying a magnetic field. The synthetic parameters, including the amount of SPIONs and PDA, were thoroughly investigated to define their effects on the nanostructure features and properties. Subsequently, the ability of the magnetic nanostructures to bind metal ions was assessed on Cu2+-containing solutions. A systematic investigation of the prepared functional nanostructures was carried out by means of complementary spectroscopic, morphological and magnetic techniques. Inductively coupled plasma atomic emission spectroscopy (ICP-AES) measurements were performed in order to estimate the Cu2+ binding ability. The overall results indicate that these nanostructures hold great promise for future bioremediation applications.

8.
Sensors (Basel) ; 23(3)2023 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-36772435

RESUMO

A novel approach for dynamic microwave modulation is proposed in the form of reconfigurable resonant circuits. This result is obtained through the monolithic integration of double split ring resonators (DSRRs) with microelectromechanical actuators (MEMS) for geometrical tuning. Two configurations were analyzed to achieve a controlled deformation of the DSRRs' metamaterial geometry by mutual rotation or extrusion along the azimuthal direction of the two constituent rings. Then, the transfer function was numerically simulated for a reconfigurable MEMS-DSRR hybrid architecture where the DSRR is embedded onto a realistic piezo actuator chip. In this case, a 370 MHz resonance frequency shift was obtained under of a 170 µm extrusion driven by a DC voltage. These characteristics in combination with a high Q factor and dimensions compatible with standard CMOS manufacturing techniques provide a step forward for the production of devices with applications in multiband telecommunications and wireless power transfer and in the IoT field.

9.
Nanomaterials (Basel) ; 12(21)2022 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-36364523

RESUMO

The growing interest in piezoresistive sensors has favored the development of numerous approaches and materials for their fabrication. Within this framework, carbon nanotubes (CNTs) are often employed. However, CNTs are a heterogeneous material with different morphological characteristics in terms of length and diameter, and, so far, experimental studies have not usually considered the effect of these parameters on the final sensor performances. Here, we observe how, by simply changing the CNTs length in a solvent-free mechanochemistry fabrication method, different porous 3D elastomeric nanocomposites with different electrical and mechanical properties can be obtained. In particular, the use of longer carbon nanotubes allows the synthesis of porous nanocomposites with better mechanical stability and conductivity, and with a nine-times-lower limit of detection (namely 0.2 Pa) when used as a piezoresistive sensor. Moreover, the material prepared with longer carbon nanotubes evidenced a faster recovery of its shape and electrical properties during press/release cycles, thus allowing faster response at different pressures. These results provide evidence as to how CNTs length can be a key aspect in obtaining piezoresistive sensors with better properties.

10.
Nanomaterials (Basel) ; 12(19)2022 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-36234601

RESUMO

In this paper, by means of high-resolution photoemission, soft X-ray absorption and atomic force microscopy, we investigate, for the first time, the mechanisms of damaging, induced by neutron source, and recovering (after annealing) of p-i-n detector devices based on hydrogenated amorphous silicon (a-Si:H). This investigation will be performed by mean of high-resolution photoemission, soft X-Ray absorption and atomic force microscopy. Due to dangling bonds, the amorphous silicon is a highly defective material. However, by hydrogenation it is possible to reduce the density of the defect by several orders of magnitude, using hydrogenation and this will allow its usage in radiation detector devices. The investigation of the damage induced by exposure to high energy irradiation and its microscopic origin is fundamental since the amount of defects determine the electronic properties of the a-Si:H. The comparison of the spectroscopic results on bare and irradiated samples shows an increased degree of disorder and a strong reduction of the Si-H bonds after irradiation. After annealing we observe a partial recovering of the Si-H bonds, reducing the disorder in the Si (possibly due to the lowering of the radiation-induced dangling bonds). Moreover, effects in the uppermost coating are also observed by spectroscopies.

11.
Pharmaceutics ; 14(9)2022 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-36145575

RESUMO

(1) Backgrond: Considering the positive effects of citicoline (CIT) in the management of some neurodegenerative diseases, the aim of this work was to develop CIT-Loaded Solid Lipid Nanoparticles (CIT-SLNs) for enhancing the therapeutic use of CIT in parkinsonian syndrome; (2) Methods: CIT-SLNs were prepared by the melt homogenization method using the self-emulsifying lipid Gelucire® 50/13 as lipid matrix. Solid-state features on CIT-SLNs were obtained with FT-IR, thermal analysis (DSC) and X-ray powder diffraction (XRPD) studies. (3) Results: CIT-SLNs showed a mean diameter of 201 nm, -2.20 mV as zeta potential and a high percentage of entrapped CIT. DSC and XRPD analyses evidenced a greater amorphous state of CIT in CIT-SLNs. On confocal microscopy, fluorescent SLNs replacing unlabeled CIT-SLNs released the dye selectively in the cytoplasm. Biological evaluation showed that pre-treatment of SH-SY5Y dopaminergic cells with CIT-SLNs (50 µM) before the addition of 40 µM 6-hydroxydopamine (6-OHDA) to mimic Parkinson's disease's degenerative pathways counteracts the cytotoxic effects induced by the neurotoxin, increasing cell viability with the consistent maintenance of both nuclear and cell morphology. In contrast, pre-treatment with CIT 50 and 60 µM or plain SLNs for 2 h followed by 6-OHDA (40 µM) did not significantly influence cell viability. (4) Conclusions: These data suggest an enhanced protection exerted by CIT-SLNs with respect to free CIT and prompt further investigation of possible molecular mechanisms that underlie this difference.

12.
Nanomaterials (Basel) ; 12(7)2022 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-35407264

RESUMO

Magnetic iron oxide nanoparticles have been extensively investigated due to their applications in various fields such as biomedicine, sensing, and environmental remediation. However, they need to be coated with a suitable material in order to make them biocompatible and to add new functionalities on their surface. This review is intended to give a comprehensive overview of recent advantages and applications of iron oxide nanoparticles coated by polydopamine film. The synthesis method of magnetic nanoparticles, their functionalization with bioinspired materials and (in particular) with polydopamine are discussed. Finally, some interesting applications of polydopamine-coated magnetic iron oxide nanoparticles will be pointed out.

13.
Sensors (Basel) ; 22(7)2022 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-35408357

RESUMO

The development of highly sensitive, portable and low-cost sensors for the evaluation of ethanol content in liquid is particularly important in several monitoring processes, from the food industry to the pharmaceutical industry. In this respect, we report the optimization of two sensing approaches based on electrical impedance spectroscopy (EIS) and complementary double split ring resonators (CDSRRs) for the detection of ethanol in water. Miniaturized EIS sensors were realized with interdigitated electrodes, and the ethanol sensing was carried out in liquid solutions without any functionalization of the electrodes. Impedance fitting analysis, with an equivalent circuit over a frequency range from 100 Hz to 1 MHz, was performed to estimate the electric parameters, which allowed us to evaluate the amount of ethanol in water solutions. On the other hand, complementary double split ring resonators (CDSRRs) were optimized by adjusting the device geometry to achieve higher quality factors while operating at a low fundamental frequency despite the small size (useful for compact electronic packaging). Both sensors were found to be efficient for the detection of low amounts of ethanol in water, even in the presence of salts. In particular, EIS sensors proved to be effective in performing a broadband evaluation of ethanol concentration and are convenient when low cost is the priority. On the other end, the employment of split ring resonators allowed us to achieve a very low limit of detection of 0.2 v/v%, and provides specific advantages in the case of known environments where they can enable fast real-time single-frequency measurements.


Assuntos
Espectroscopia Dielétrica , Água , Espectroscopia Dielétrica/métodos , Impedância Elétrica , Eletrodos , Etanol
14.
Biosensors (Basel) ; 12(3)2022 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-35323417

RESUMO

The Ampelovirus Grapevine leafroll-associated virus 3 (GLRaV-3) and the Nepovirus Grapevine fanleaf virus (GFLV) are pathogens reported in many grapevine-growing areas all over the world, main causal agents of grapevine leafroll disease and grapevine fanleaf disease, respectively. Prevention of virus spread thanks to rapid diagnosis of infected plants is a key factor for control of both diseases. Although serological (e.g., enzyme-linked immunosorbent assay-ELISA test) and molecular methods are available to reveal the presence of the viruses, they turn out to be quite expensive, time-consuming and laborious, especially for large-scale health screening. Here we report the optimization of a lab-on-a-chip (LOC) for GLRaV-3 and GFLV detection, based on an electrochemical transduction and a microfluidic multichamber design for measurements in quadruplicate and simultaneous detection of both targets. The LOC detect GLRaV-3 and GFLV at dilution factors more than 15 times higher than ELISA, providing a higher sensitivity in the detection of both viruses. Furthermore, the platform offers several advantages as easy-to-use, rapid-test, portability and low costs, favoring its potential application for large-scale monitoring programs. Compared to other grapevine virus biosensors, our sensing platform is the first one to provide a dose-dependent calibration curve combined with a microfluidic module for sample analysis and a portable electronics providing an operator-independent read-out scheme.


Assuntos
Closteroviridae , Nepovirus , Vitis , Ensaio de Imunoadsorção Enzimática , Dispositivos Lab-On-A-Chip , Doenças das Plantas
15.
J Colloid Interface Sci ; 607(Pt 2): 1436-1445, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34583046

RESUMO

HYPOTHESIS: Nanocarbon/polymeric 3D porous composites have been widely developed as piezoresistive sensors due to their improved performances. Functionalized nanocarbon is usually used to allow its adsorption on the surface of porous polymeric material. However, both the functionalization and the surface localized distribution of the nanomaterial can limit the nanocarbon effect on conductivity and mechanical stability of the material thus affecting piezoresistive performances. EXPERIMENTS: A novel nanoarchitectonics strategy to prepare an elastomeric/carbon nanotubes (CNTs) 3D porous piezoresistive nanocomposite is developed. The fabrication route does not require complex apparatus and CNTs chemical functionalization. Moreover, foams of any shape and dimensions can be produced with neither complex machinery and procedures nor wastes production. FINDINGS: The obtained material is characterized by the presence of well dispersed pristine CNTs on both surface and bulk of the polymeric matrix. The foam exhibited improved piezoresistive properties with excellent compressive stress (>150 kPa), sensitivity at low displacement (29 kPa-1) and limit of detection for both pressure (2 Pa) and extension (130 nm). These excellent features could allow the use of the as prepared nanocomposite in different applications ranging from wearable devices to robotic or infrastructure monitoring with outstanding flexibility.


Assuntos
Nanocompostos , Nanotubos de Carbono , Dispositivos Eletrônicos Vestíveis , Elastômeros , Condutividade Elétrica
16.
Int J Mol Sci ; 22(23)2021 12 03.
Artigo em Inglês | MEDLINE | ID: mdl-34884894

RESUMO

Hepatocellular carcinoma (HCC) is a highly lethal cancer, and although a few drugs are available for treatment, therapeutic effectiveness is still unsatisfactory. New drugs are urgently needed for hepatocellular carcinoma (HCC) patients. In this context, reliable preclinical assays are of paramount importance to screen the effectiveness of new drugs and, in particular, measure their effects on HCC cell proliferation. However, cell proliferation measurement is a time-consuming and operator-dependent procedure. The aim of this study was to validate an engineered miniaturized on-chip platform for real-time, non-destructive cell proliferation assays and drug screening. The effectiveness of Sorafenib, the first-line drug mainly used for patients with advanced HCC, was tested in parallel, comparing the gold standard 96-well-plate assay and our new lab-on-chip platform. Results from the lab-on-chip are consistent in intra-assay replicates and comparable to the output of standard crystal violet proliferation assays for assessing Sorafenib effectiveness on HCC cell proliferation. The miniaturized platform presents several advantages in terms of lesser reagents consumption, operator time, and costs, as well as overcoming a number of technical and operator-dependent pitfalls. Moreover, the number of cells required is lower, a relevant issue when primary cell cultures are used. In conclusion, the availability of inexpensive on-chip assays can speed up drug development, especially by using patient-derived samples to take into account disease heterogeneity and patient-specific characteristics.


Assuntos
Carcinoma Hepatocelular/tratamento farmacológico , Proliferação de Células , Avaliação Pré-Clínica de Medicamentos/métodos , Dispositivos Lab-On-A-Chip , Neoplasias Hepáticas/tratamento farmacológico , Sorafenibe/farmacologia , Antineoplásicos/farmacologia , Carcinoma Hepatocelular/fisiopatologia , Fibroblastos/efeitos dos fármacos , Fibroblastos/fisiologia , Humanos , Neoplasias Hepáticas/fisiopatologia
17.
Nano Lett ; 21(14): 6179-6187, 2021 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-34251835

RESUMO

Advanced sensing tools, detecting extremely low concentrations of circulating biomarkers, can open unexplored routes toward early diagnostics and diseases progression monitoring. Here, we demonstrate the sensing capabilities of a chip-based metamaterial, combining 3D chiral geometry with a functional core-shell nanoarchitecture. The chiral metamaterial provides a circular polarization-dependent optical response, allowing analysis in a complex environment without significant background interferences. The functional nanoarchitecture, based on the conformal coating with a polymer shell, modifies the chiral metamaterial near- and far-field optical response because of the energy transfer between dielectric shell polarization charges and plasmonic core free electrons, leading to efficient interaction with biomolecules. The system sensitivity slope is 27 nm/pM, in the detection of TAR DNA-binding protein 43, clinically relevant for neurodegenerative diseases. Measurements were performed in spiked solution and in human serum with concentrations from 1 pM down to 10 fM, which is a range not accessible with common immunological assays, opening new perspectives for next-generation biomedical systems.


Assuntos
Dicroísmo Circular , Humanos
18.
Sensors (Basel) ; 21(6)2021 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-33803614

RESUMO

Human activities significantly contribute to worldwide spread of phytopathological adversities. Pathogen-related food losses are today responsible for a reduction in quantity and quality of yield and decrease value and financial returns. As a result, "early detection" in combination with "fast, accurate, and cheap" diagnostics have also become the new mantra in plant pathology, especially for emerging diseases or challenging pathogens that spread thanks to asymptomatic individuals with subtle initial symptoms but are then difficult to face. Furthermore, in a globalized market sensitive to epidemics, innovative tools suitable for field-use represent the new frontier with respect to diagnostic laboratories, ensuring that the instruments and techniques used are suitable for the operational contexts. In this framework, portable systems and interconnection with Internet of Things (IoT) play a pivotal role. Here we review innovative diagnostic methods based on nanotechnologies and new perspectives concerning information and communication technology (ICT) in agriculture, resulting in an improvement in agricultural and rural development and in the ability to revolutionize the concept of "preventive actions", making the difference in fighting against phytopathogens, all over the world.


Assuntos
Agricultura , Internet das Coisas , Humanos , Nanotecnologia , Doenças das Plantas , Plantas
19.
Biosensors (Basel) ; 10(6)2020 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-32549369

RESUMO

Pectobacterium atrosepticum (Pba) is a quarantine and threatening phytopathogen known as the causal agent of blackleg and soft rot disease of potatoes in many areas. Its early detection is then important to have healthy potato tubers and reduce economic losses. Today, conventional methods such as enzyme-linked immunosorbent-assay (ELISA) and polymerase chain reaction (PCR) are typically used for Pba detection, but they are expensive and time-consuming. Here we report on the optimization of an alternative approach based on an electrochemical impedance immunosensor combining a microfluidic module and a microelectrodes array, and having advantages in terms of low cost, ease of use and portability. For validation and for assessing its performance, the lab-on-chip platform has been compared with two standard methods (ELISA and PCR).


Assuntos
Técnicas Biossensoriais , Pectobacterium/isolamento & purificação , Doenças das Plantas/microbiologia , Solanum tuberosum/microbiologia , Ensaio de Imunoadsorção Enzimática , Dispositivos Lab-On-A-Chip , Reação em Cadeia da Polimerase
20.
Micromachines (Basel) ; 11(5)2020 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-32403362

RESUMO

Sustainable growth, environmental preservation, and improvement of life quality are strategic fields of worldwide interest and cornerstones of international policies. Humanity health and prosperity are closely related to our present choices on sustainable development. The main sources of pollution concern industry, including mining, chemical companies, and refineries, wastewater treatment; and consumers themselves. In order to guide and evaluate the effects of environmental policies, diffuse monitoring campaigns and detailed (big) data analyses are needed. In this respect, the development and availability of innovative sensor platforms for field analysis and remote sensing are of crucial relevance. In this review, we provide an overview of the area, analyzing the major needs, available technologies, novel approaches, and perspectives. Among environmental pollutants that threaten the biosphere, we focus on inorganic and organic contaminants, which affect air and water quality. We describe the technologies for their assessment in the environment and then draw some conclusions and mention future perspectives opened by the integration of sensing technologies with robotics and the Internet of Things. Without the ambition to be exhaustive in such a rapidly growing field, this review is intended as a support for researchers and stakeholders looking for current, state-of-the-art, and key enabling technologies for environmental monitoring.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...