Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 174
Filtrar
1.
Eur J Clin Invest ; : e14274, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38925546

RESUMO

BACKGROUND: Invasive coronary angiography (ICA) is the standard for pre-procedural assessment of coronary artery disease (CAD) in patients undergoing transcatheter aortic valve implantation (TAVI). However, it requires hospitalization and can be associated with complications. Computed tomography angiography (CTA) may be a viable alternative to rule out prognostically relevant CAD. METHODS: The EASE-IT CT Registry is an investigator-initiated, prospective, observational, multicentre pilot registry involving patients aged ≥75 years with severe aortic stenosis (AS) intended to implant a transcatheter heart valve (THV) of the SAPIEN family. A total of 150 patients will be recruited from four sites in Germany and Austria. The registry will consist of two prospective cohorts: the investigational CTA-only cohort and the CTA + ICA control cohort. The CTA-only cohort will enrol 100 patients in whom significant (≥50%) left main (LM) and/or proximal left anterior descending artery (LAD) stenosis are ruled out on CTA. The CTA + ICA control cohort will enrol 50 patients who have undergone both CTA and ICA before TAVI and in whom ≥50% LM/proximal LAD stenosis has been ruled out by CTA. Three composite endpoints will be assessed at 3 months post-TAVI: CAD-specific endpoints, VARC-3-defined device success and early safety. CONCLUSION: The EASE-IT CT Registry evaluates whether TAVI can be carried out safely without performing ICA if prognostically relevant CAD of the LM/proximal LAD is ruled out with CTA. If so, the omission of ICA would help streamline the pre-procedural workup of TAVI patients.

2.
Wien Klin Wochenschr ; 136(Suppl 3): 61-74, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38743084

RESUMO

INTRODUCTION: Percutaneous coronary intervention is a well-established revascularization strategy for patients with coronary artery disease. Recent technical advances such as radial access, third generation drug-eluting stents and highly effective antiplatelet therapy have substantially improved the safety profile of coronary procedures. Despite several practice guidelines and a clear patient preference of early hospital discharge, the percentage of coronary procedures performed in an outpatient setting in Austria remains low, mostly due to safety concerns. METHODS: The aim of this consensus statement is to provide a practical framework for the safe and effective implementation of coronary outpatient clinics in Austria. Based on a structured literature review and an in-depth analysis of available practice guidelines a consensus statement was developed and peer-reviewed within the working group of interventional cardiology (AGIK) of the Austrian Society of Cardiology. RESULTS: Based on the available literature same-day discharge coronary procedures show a favorable safety profile with no increase in the risk of major adverse events compared to an overnight stay. This document provides a detailed consensus in various clinical settings. The most important prerequisite for same-day discharge is, however, adequate selection of suitable patients and a structured peri-interventional and postinterventional management plan. CONCLUSION: Based on the data analysis this consensus document provides detailed practice guidelines for the safe operation of daycare cathlab programs in Austria.


Assuntos
Cardiologia , Doença da Artéria Coronariana , Alta do Paciente , Intervenção Coronária Percutânea , Áustria , Humanos , Intervenção Coronária Percutânea/normas , Alta do Paciente/normas , Cardiologia/normas , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/cirurgia , Guias de Prática Clínica como Assunto , Tempo de Internação , Assistência Ambulatorial/normas
3.
Wien Klin Wochenschr ; 136(Suppl 3): 44-60, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38743083

RESUMO

INTRODUCTION: Percutaneous coronary intervention is a well-established revascularization strategy for patients with coronary artery disease. The safety and feasibility of performing these procedures on a same-day discharge basis for selected patients has been studied in a large number of mostly nonrandomized trials. An up to date literature review should focus on trials with radial access, representing the current standard for coronary procedures in Austria and other European countries. METHODS: The aim of this consensus statement is to review the most recent evidence for the safety and feasibility of performing same-day discharge procedures in selected patients. A structured literature search was performed using prespecified search criteria, focusing on trials with radial access procedures. RESULTS: A total of 44 clinical trials and 4 large meta-analyses were retrieved, spanning 21 years of clinical evidence from 2001 to 2022. The outcome data from a wide range of clinical settings were unanimous in showing no negative effect on early (24 h) or late (30 day) major adverse events after same-day discharge coronary procedures. Based on nine prospective trials a comprehensive meta-analysis was compiled. Using 1­month major adverse events data the pooled odds ratio of same-day discharge versus overnight stay procedures was 0.66 (95% confidence interval, CI 0.35-01.24; p = 0.19; I2 0%), indicating a noninferiority in carefully selected patients. CONCLUSION: Outcome data from same-day discharge coronary intervention trials with radial access confirm the robust safety profile showing no increase in the risk of major adverse events compared to overnight stay.


Assuntos
Doença da Artéria Coronariana , Alta do Paciente , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/cirurgia , Complicações Pós-Operatórias/epidemiologia , Procedimentos Cirúrgicos Ambulatórios/efeitos adversos , Resultado do Tratamento , Áustria , Fatores de Risco , Prevalência
4.
Front Cardiovasc Med ; 11: 1338253, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38464840

RESUMO

Background: Coronary artery disease (CAD) is a common finding in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (TAVR). However, the impact on prognosis of chronic total occlusions (CTOs), a drastic expression of CAD, remains unclear. Methods and results: We retrospectively reviewed 1,487 consecutive TAVR cases performed at a single tertiary care medical center. Pre-TAVR angiograms were analyzed for the presence of a CTO. At the time of TAVR, 11.2% (n = 167) patients had a CTO. There was no significant association between the presence of a CTO and in-hospital or 30-day mortality. There was also no difference in long-term survival. LV ejection fraction and mean aortic gradients were lower in the CTO group. Conclusions: Our analysis suggests that concomitant CTO lesions in patients undergoing TAVR differ in their risk profile and clinical findings to patients without CTO. CTO lesion per se were not associated with increased mortality, nevertheless CTOs which supply non-viable myocardium in TAVR population were associated with increased risk of death. Additional research is needed to evaluate the prognostic significance of CTO lesions in TAVR patients.

5.
Lancet Digit Health ; 6(4): e251-e260, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38519153

RESUMO

BACKGROUND: The diagnosis of cardiac amyloidosis can be established non-invasively by scintigraphy using bone-avid tracers, but visual assessment is subjective and can lead to misdiagnosis. We aimed to develop and validate an artificial intelligence (AI) system for standardised and reliable screening of cardiac amyloidosis-suggestive uptake and assess its prognostic value, using a multinational database of 99mTc-scintigraphy data across multiple tracers and scanners. METHODS: In this retrospective, international, multicentre, cross-tracer development and validation study, 16 241 patients with 19 401 scans were included from nine centres: one hospital in Austria (consecutive recruitment Jan 4, 2010, to Aug 19, 2020), five hospital sites in London, UK (consecutive recruitment Oct 1, 2014, to Sept 29, 2022), two centres in China (selected scans from Jan 1, 2021, to Oct 31, 2022), and one centre in Italy (selected scans from Jan 1, 2011, to May 23, 2023). The dataset included all patients referred to whole-body 99mTc-scintigraphy with an anterior view and all 99mTc-labelled tracers currently used to identify cardiac amyloidosis-suggestive uptake. Exclusion criteria were image acquisition at less than 2 h (99mTc-3,3-diphosphono-1,2-propanodicarboxylic acid, 99mTc-hydroxymethylene diphosphonate, and 99mTc-methylene diphosphonate) or less than 1 h (99mTc-pyrophosphate) after tracer injection and if patients' imaging and clinical data could not be linked. Ground truth annotation was derived from centralised core-lab consensus reading of at least three independent experts (CN, TT-W, and JN). An AI system for detection of cardiac amyloidosis-associated high-grade cardiac tracer uptake was developed using data from one centre (Austria) and independently validated in the remaining centres. A multicase, multireader study and a medical algorithmic audit were conducted to assess clinician performance compared with AI and to evaluate and correct failure modes. The system's prognostic value in predicting mortality was tested in the consecutively recruited cohorts using cox proportional hazards models for each cohort individually and for the combined cohorts. FINDINGS: The prevalence of cases positive for cardiac amyloidosis-suggestive uptake was 142 (2%) of 9176 patients in the Austrian, 125 (2%) of 6763 patients in the UK, 63 (62%) of 102 patients in the Chinese, and 103 (52%) of 200 patients in the Italian cohorts. In the Austrian cohort, cross-validation performance showed an area under the curve (AUC) of 1·000 (95% CI 1·000-1·000). Independent validation yielded AUCs of 0·997 (0·993-0·999) for the UK, 0·925 (0·871-0·971) for the Chinese, and 1·000 (0·999-1·000) for the Italian cohorts. In the multicase multireader study, five physicians disagreed in 22 (11%) of 200 cases (Fleiss' kappa 0·89), with a mean AUC of 0·946 (95% CI 0·924-0·967), which was inferior to AI (AUC 0·997 [0·991-1·000], p=0·0040). The medical algorithmic audit demonstrated the system's robustness across demographic factors, tracers, scanners, and centres. The AI's predictions were independently prognostic for overall mortality (adjusted hazard ratio 1·44 [95% CI 1·19-1·74], p<0·0001). INTERPRETATION: AI-based screening of cardiac amyloidosis-suggestive uptake in patients undergoing scintigraphy was reliable, eliminated inter-rater variability, and portended prognostic value, with potential implications for identification, referral, and management pathways. FUNDING: Pfizer.


Assuntos
Amiloidose , Cardiomiopatias , Humanos , Amiloidose/diagnóstico por imagem , Amiloidose/metabolismo , Inteligência Artificial , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/metabolismo , Prognóstico , Cintilografia , Compostos Radiofarmacêuticos , Estudos Retrospectivos
6.
Eur Heart J ; 45(21): 1904-1916, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38554125

RESUMO

BACKGROUND AND AIMS: There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries. METHODS: This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices. Principal objectives were to reduce hospital length of stay (LoS) and duration of intensive care stay. Secondary objective was to document patient safety. RESULTS: Between January 2020 and March 2023, 897 patients were documented prior to and 1491 patients after the implementation of BENCHMARK practices. Patient characteristics were consistent with a known older TAVI population and only minor differences. Mean LoS was reduced from 7.7 ± 7.0 to 5.8 ± 5.6 days (median 6 vs. 4 days; P < .001). Duration of intensive care was reduced from 1.8 to 1.3 days (median 1.1 vs. 0.9 days; P < .001). Adoption of peri-procedure best practices led to increased use of local anaesthesia (96.1% vs. 84.3%; P < .001) and decreased procedure (median 47 vs. 60 min; P < .001) and intervention times (85 vs. 95 min; P < .001). Thirty-day patient safety did not appear to be compromised with no differences in all-cause mortality (0.6% in both groups combined), stroke/transient ischaemic attack (1.4%), life-threatening bleeding (1.3%), stage 2/3 acute kidney injury (0.7%), and valve-related readmission (1.2%). CONCLUSIONS: Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety.


Assuntos
Estenose da Valva Aórtica , Benchmarking , Tempo de Internação , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Masculino , Feminino , Idoso de 80 Anos ou mais , Tempo de Internação/estatística & dados numéricos , Idoso , Procedimentos Clínicos , Europa (Continente)/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Segurança do Paciente
7.
JACC Cardiovasc Interv ; 17(1): 60-72, 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38069986

RESUMO

BACKGROUND: Several orthotopic transcatheter strategies have been developed to treat severe tricuspid regurgitation (TR); however, many patients are deemed unsuitable. Caval valve implantation with the TricValve system addresses this unmet need. OBJECTIVES: This study sought to determine the impact of TricValve on systemic congestion and quality of life (QOL) at 1 year. METHODS: The TRICUS (Safety and Efficacy of the TricValve® Transcatheter Bicaval Valves System in the Superior and Inferior Vena Cava in Patients With Severe Tricuspid Regurgitation) and TRICUS EURO studies were prospective, nonblinded, nonrandomized, single-arm trials representing the early-in-man experience of the TricValve system in NYHA functional class III or IV severe TR patients, optimally medicated and ineligible for open heart surgery, with significant caval backflow. The primary endpoint was QOL metrics and functional status. The 1-year results of the combined cohort are described here. RESULTS: Forty-four patients were included. Mean age was 76.2 ± 7.5 years, 81.0% were women, and the TRISCORE (risk score model for isolated tricuspid valve surgery) was 5.3 ± 1.3. Clinical improvement at 1 year was achieved in 42 (95.5%) patients, measured by (at least 1 of) an increase in ≥15 points from baseline in 12-item Kansas City Cardiomyopathy Questionnaire score, improvement to NYHA functional class to I or II, or an increase ≥40 m in the 6-minute walk test. There were 3 (6.8%) deaths at 1-year follow-up (1 cardiovascular), and the heart failure rehospitalization rate was 29.5%. Stent fracture, conduction system disturbances, or clinically significant leaflet thrombosis were not detected. Abolished hepatic vein backflow was achieved and persisted in 63.8% of the patients, contributing towards a reduction in congestive symptoms, N-terminal pro-B-type natriuretic peptide levels (P = 0.032), and diuretic treatment. CONCLUSIONS: Caval valve implantation with the TricValve system associated with meaningful 1-year clinical improvements in terms of QOL along with relatively low mortality rates. (TRICUS Study - Safety and Efficacy of the TricValve® Device; NCT03723239).


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Cateterismo Cardíaco , Seguimentos , Estudos Prospectivos , Qualidade de Vida , Índice de Gravidade de Doença , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
8.
Eur J Cardiothorac Surg ; 65(1)2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-37756697

RESUMO

OBJECTIVES: This population-based cohort study investigated mid-term outcome after surgical aortic valve replacement with a bioprosthetic or mechanical valve prosthesis in patients aged <50 years in a European social welfare state. METHODS: We analysed patient data from the main social insurance carriers in Austria (2010-2020). Subsequent patient-level record linkage with national health data provided patient characteristics and clinical outcome. Survival, reoperation, myocardial infarction, heart failure, embolic stroke or intracerebral haemorrhage, bleeding other than intracerebral haemorrhage and major adverse cardiac events were evaluated as outcomes. RESULTS: A total of 991 patients were analysed. Regarding demographics, no major differences between groups were observed. Multivariable Cox regression revealed no significant difference in overall survival (P = 0.352) with a median follow-up time of 6.2 years. Reoperation-free survival was decreased (hazard ratio = 1.560 [95% CI: 1.076-2.262], P = 0.019) and the risk for reoperation was increased (hazard ratio = 2.770 [95% CI: 1.402-5.472], P = 0.003) in patients who received bioprostheses. Estimated probability of death after reoperation was 0.23 (CL: 0.08-0.35) after 2 years and 0.34 (CL: 0.06-0.53) after 10 years over both groups. Regarding further outcomes, no significant differences between the two groups were observed. CONCLUSIONS: In patients below 50 years of age receiving aortic valve replacement, implantation of bioprostheses when compared to mechanical heart valve prostheses was associated with a significantly higher rate of reoperations and reduced reoperation-free survival. Nevertheless, we could not observe a difference in overall survival. However, long-term follow-up has to evaluate that a significantly lower rate of reoperations may translate in consistently improved long-term survival.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Pessoa de Meia-Idade , Próteses Valvulares Cardíacas/efeitos adversos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos de Coortes , Desenho de Prótese , Reoperação , Bioprótese/efeitos adversos , Hemorragia Cerebral/etiologia , Pontuação de Propensão , Resultado do Tratamento , Estudos Retrospectivos , Falha de Prótese
9.
Wien Klin Wochenschr ; 135(23-24): 663-666, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37994938

RESUMO

Significant sex-specific differences were described in the presentation, management and outcome of acute coronary syndrom (ACS) patients. Female ACS patients more often presented with noncardiac symptoms, which lead to significant time delays between symptom onset and treatment. Furthermore, multiple studies from various countries described that women with ACS were less likely to receive the medical or reperfusion therapy recommended by the respective guidelines, resulting in higher in-hospital mortality rates.The treating physicians and the patients need to be more aware of the described differences to ensure the best possible medical care for ACS patients, irrespective of sex.


Assuntos
Síndrome Coronariana Aguda , Humanos , Masculino , Feminino , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/terapia , Caracteres Sexuais , Resultado do Tratamento , Fatores Sexuais
10.
Clin Res Cardiol ; 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37870628

RESUMO

BACKGROUND: Right ventricular-to-pulmonary artery (RV-PA) coupling has recently been shown to be associated with outcome in valvular heart disease. However, longitudinal data on RV dysfunction and reverse cardiac remodeling in patients following transcatheter edge-to-edge mitral valve repair (M-TEER) are scarce. METHODS: Consecutive patients with primary as well as secondary mitral regurgitation (MR) were prospectively enrolled and had comprehensive echocardiographic and invasive hemodynamic assessment at baseline. Kaplan-Meier estimates and multivariable Cox-regression analyses were performed, using a composite endpoint of heart failure hospitalization and death. RESULTS: Between April 2018 and January 2021, 156 patients (median 78 y/o, 55% female, EuroSCORE II: 6.9%) underwent M-TEER. On presentation, 64% showed impaired RV-PA coupling defined as tricuspid annular plane systolic excursion to pulmonary artery systolic pressure (TAPSE/PASP) ratio < 0.36. Event-free survival rates at 2 years were significantly lower among patients with impaired coupling (57 vs. 82%, p < 0.001), both in patients with primary (64 vs. 91%, p = 0.009) and secondary MR (54 vs. 76%, p = 0.026). On multivariable Cox-regression analyses adjusted for baseline, imaging, hemodynamic, and procedural data, TAPSE/PASP ratio < 0.36 was independently associated with outcome (adj.HR 2.74, 95% CI 1.17-6.43, p = 0.021). At 1-year follow-up, RV-PA coupling improved (TAPSE: ∆ + 3 mm, PASP: ∆ - 10 mmHg, p for both < 0.001), alongside with a reduction in tricuspid regurgitation (TR) severity (grade ≥ II: 77-54%, p < 0.001). CONCLUSIONS: TAPSE/PASP ratio was associated with outcome in patients undergoing M-TEER for primary as well as secondary MR. RV-PA coupling, alongside with TR severity, improved after M-TEER and might thus provide prognostic information in addition to established markers of poor outcome.

11.
J Clin Med ; 12(16)2023 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-37629221

RESUMO

BACKGROUND: This study sought to investigate the prognostic impact of right atrial (RA) size and function in patients with heart failure with preserved ejection fraction (HFpEF) in sinus rhythm (SR) and atrial fibrillation (AF). METHODS: Consecutive HFpEF patients were enrolled and indexed RA volumes and emptying fractions (RA-EF) were assessed by cardiac magnetic resonance imaging (CMR). For patients in SR, feature tracking of the RA wall was performed during CMR. In addition, all patients underwent right and left heart catheterization and 6 min walk distance (6MWD) and N-terminal prohormone of brain natriuretic peptide (NT-proBNP) evaluations. We prospectively followed patients and used Cox regression models to determine the association of RA size and function with a composite endpoint of heart failure hospitalization and cardiovascular death. RESULTS: A total of 188 patients (71% female patients, 70 ± 8 years old) were included. Ninety-two patients (49%) were in persistent AF. Eighty-five patients reached the combined endpoint during a follow-up of 69 (42-97) months. After a multivariate cox regression analysis, the impaired RA reservoir strain (HR 0.949; 95% CI [0.909-0.990], p = 0.016), the RA reservoir strain rate (HR 0.991; 95% CI [0.983-0.999], p = 0.028), the RA conduit strain (HR 0.932; 95% CI [0.879-0.988], p = 0.019), and the RA conduit strain rate (HR 0.989; 95% CI [0.881-0.997], p = 0.011) were significantly associated with a worse outcome for patients in SR. In persistent AF, no RA imaging parameter was related to outcome after a multivariate regression analysis. CONCLUSIONS: In HFpEF patients in SR, CMR parameters of impaired RA conduit and reservoir function are associated with dismal cardiovascular outcomes. In persistent AF, RA parameters lose their prognostic ability.

12.
Eur J Heart Fail ; 25(10): 1808-1818, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37462329

RESUMO

AIMS: Cardiac decompensation in aortic stenosis (AS) involves extra-valvular cardiac damage and progressive fluid overload (FO). FO can be objectively quantified using bioimpedance spectroscopy. We aimed to assess the prognostic value of FO beyond established damage markers to guide risk stratification. METHODS AND RESULTS: Consecutive patients with severe AS scheduled for transcatheter aortic valve implantation (TAVI) underwent prospective risk assessment with bioimpedance spectroscopy (BIS) and echocardiography. FO by BIS was defined as ≥1.0 L (0.0 L = euvolaemia). The extent of cardiac damage was assessed by echocardiography according to an established staging classification. Right-sided cardiac damage (rCD) was defined as pulmonary vasculature/tricuspid/right ventricular damage. Hospitalization for heart failure (HHF) and/or death served as primary endpoint. In total, 880 patients (81 ± 7 years, 47% female) undergoing TAVI were included and 360 (41%) had FO. Clinical examination in patients with FO was unremarkable for congestion signs in >50%. A quarter had FO but no rCD (FO+/rCD-). FO+/rCD+ had the highest damage markers, including N-terminal pro-B-type natriuretic peptide (NT-proBNP) levels. After 2.4 ± 1.0 years of follow-up, 236 patients (27%) had reached the primary endpoint (29 HHF, 194 deaths, 13 both). Quantitatively, every 1.0 L increase in bioimpedance was associated with a 13% increase in event hazard (adjusted hazard ratio 1.13, 95% confidence interval 1.06-1.22, p < 0.001). FO provided incremental prognostic value to traditional risk markers (NT-proBNP, EuroSCORE II, damage on echocardiography). Stratification according to FO and rCD yielded worse outcomes for FO+/rCD+ and FO+/rCD-, but not FO-/rCD+, compared to FO-/rCD-. CONCLUSION: Quantitative FO in patients with severe AS improves risk prediction of worse post-interventional outcomes compared to traditional risk assessment.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Insuficiência Cardíaca/etiologia , Estudos Prospectivos , Prognóstico , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia
14.
Catheter Cardiovasc Interv ; 101(4): 806-812, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36802136

RESUMO

Coronary artery disease (CAD) is frequently encountered in patients evaluated for transcatheter aortic valve replacement (TAVR) due to severe aortic stenosis. The prognostic relevance of chronic total occlusions (CTOs) in this setting is poorly understood. We conducted a search of MEDLINE and EMBASE to identify studies evaluating patients who underwent TAVR and evaluated outcomes depending on the presence of coronary CTOs. Pooled analysis was performed to estimate the rate and risk ratio for mortality. Four studies involving 25,432 patients fulfilled the inclusion criteria. The follow up ranged from in-hospital outcomes to 8-years follow-up. Coronary artery disease was present in 67.8% to 75.5% of patients in 3 studies which reported this variable. The prevalence of CTOs varied between 2% and 12.6% in this cohort. The presence of CTOs was associated with increase in length of stay (8.1 ± 8.2 vs. 5.9 ± 6.5, p < 0.01), cardiogenic shock (5.1% vs. 1.7%, p < 0.01), acute myocardial infarction (5.8% vs. 2.8%, p = 0.02) and acute kidney injury (18.6% vs. 13.9%, p = 0.048). The pooled 1-year death rate revealed 41 deaths in 165 patients in the CTO group and 396 deaths in 1663 patients with no CTO ((24.8%) vs. (23.8%)). The meta-analysis of death with CTO versus no CTO showed a nonsignificant trend toward increased mortality with CTOs (risk ratio 1.11 95% CI 0.90-1.40, I2 = 0%). Our analysis suggests that concomitant CTO lesions in patients undergoing TAVR are common, and its presence was associated with increased in-hospital complications. However, CTO presence by itself was not associated with increased long-term mortality, only a nonsignificant trend toward an increased risk of death in patients with CTO was found. Further studies are warranted to assess the prognostic relevance of CTO lesion in TAVR patients.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Oclusão Coronária , Infarto do Miocárdio , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia
15.
Eur J Clin Invest ; 53(6): e13961, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36710528

RESUMO

BACKGROUND: Mitral- and tricuspid regurgitation are associated with significant morbidity and mortality and are increasingly treated interventionally. CardioMEMS is a transcutaneously implanted pressure sensor placed in the pulmonary artery that allows invasive measurement of pulmonary artery pressure and cardiac output. METHODS: This proof-of-concept study aimed to observe hemodynamic changes as determined by CardioMEMS after transcatheter atrioventricular valve interventions, assess the additional value of CardioMEMS on top of echocardiography, and investigate a potential effect of CardioMEMS on outcome. Patients treated with transcatheter mitral- or tricuspid valve interventions (mitral: TMVR, tricuspid: TTVR) or bicaval valve implantation (bi-CAVI) were recruited. All patients were followed for 12 months. RESULTS: Thirty-six patients were included (4 with CardioMEMS, 32 controls). Patients with CardioMEMS were monitored prior to intervention and 3-12 months thereafter (one received TMVR, one bi-CAVI, one both TMVR and TTVR, and one isolated TTVR). CardioMEMS group: In both patients with TMVR and in the patient with bi-CAVI, mean pulmonary artery pressures decreased (all p < .001) and cardiac output increased significantly (both TMVR p < .001 and bi-CAVI p = .006) while functional parameters, echocardiography, and NT-proBNP were difficult to interpret, unreliable, or both. Changes after TTVR remained inconclusive. CONCLUSION: Invasive monitoring using CardioMEMS provides important information after mitral- and tricuspid valve interventions. Such data pave the way for a deeper understanding of the prerequisites for optimal patient selection and management for catheter-based interventions.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco , Resultado do Tratamento
16.
Am Heart J ; 256: 139-147, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36410441

RESUMO

BACKGROUND: Surgical aortic valve bioprostheses may degenerate over time and require redo intervention. Transcatheter aortic valve replacement (TAVR) is a less invasive alternative to redo surgery. The BAlloon Expandable vs. SElf Expanding Transcatheter VaLve for Degenerated BioprosthesIs (BASELINE) trial was designed to compare the performance of the balloon-expandable SAPIEN-3 Ultra and the self-expanding EVOLUT PRO+ valve systems in symptomatic patients with a failing surgical bioprosthesis. METHODS: The BASELINE trial is an investigator-initiated, non-funded, prospective, randomized, open-label, superiority trial enrolling a total of 440 patients in up to 50 sites in 12 countries in Europe and North-America. The primary endpoint is device success at 30-days defined by the Valve Academic Research Consortium-3 Criteria as the composite of technical success, freedom from mortality, freedom for surgery or intervention related to the device or to a major vascular or access-related or cardiac structural complication with an intended performance of the valve (mean gradient <20 mmHg and less than moderate aortic regurgitation). The co-primary endpoint at 1 year is defined as the composite of all-cause death, disabling stroke, rehospitalization for heart failure or valve related problems. Independent Core Laboratories will conduct uniform analyses of echocardiography (pre-, post-, 1-year post-procedure), multi-sliced computed tomography (pre-, and if available post-procedure) and cine-fluoroscopy studies. CONCLUSIONS: The BASELINE trial is a head-to-head comparative trial investigating the 2 most used contemporary transcatheter heart valves for the treatment of a failing surgical aortic bioprosthesis. (ClinicalTrials.gov number NCT04843072).


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/métodos
17.
Eur Heart J Cardiovasc Imaging ; 24(6): 796-806, 2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-36099163

RESUMO

AIMS: Bioprosthetic valve dysfunction (BVD) is a major concern regarding transcatheter aortic valve implantation (TAVI) durability. We aimed to assess incidence, correlates, causes, and outcome of early to mid-term BVD after TAVI in relation to patient's life expectancy. METHODS AND RESULTS: Consecutive TAVI recipients (2007-20) with a follow-up ≥1 year were prospectively included. BVD and bioprosthetic valve failure (BVF) were assessed according to Valve-Academic-Research-Consortium-3. BVD/BVF and all-cause death served as endpoints. Average life expectancy was calculated from National Open Health Data and patients were stratified according to tertiles (1st: <6.85 years, 2nd: 6.85-9.7 years, 3rd: >9.7 years). Of 1047 patients (81.6 ± 6.8 years old, EuroSCORE II 4.5 ± 2.5), ≥2 follow ups were available from 622 (serial echo cohort). After a median echo follow up of 12.2 months, incidence rates of BVD/BVF were 8.4% (95% confidence interval 6.7-10.3), and 3.5% (2.5-4.9) per valve-year, respectively, without differences between life expectancy tertiles. The incidence of BVD was two-fold higher within the first year of implant (9.9% per valve-year) vs. beyond (4.8% per valve-year). Valve-in-valve procedure and residual stenosis, but not age/life expectancy predisposed for BVD. BVD/BVF were independently associated with outcome for patients in the first [adjusted hazard ratio (AHR) 1.72 (1.06-2.88)/2.97 (1.72-6.22)] and second [AHR 1.96 (1.02-3.73)/2.31 (1.00-5.30)], but not the third tertile of life expectancy (P = n.s.). CONCLUSIONS: In this large prospective observational cohort, early to mid-term BVD after TAVI occurred at the same rate across the spectrum of life expectancy and was associated with increased mortality in patients with short but not in those with the longest life expectancy.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Incidência , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
18.
JACC Adv ; 2(2): 100259, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38938310

RESUMO

Background: In the ENVISAGE-TAVI AF (Edoxaban vs Standard of Care and Their Effects on Clinical Outcomes in Patients Having Undergone Transcatheter Aortic Valve Implantation-Atrial Fibrillation) trial, edoxaban was noninferior to vitamin K antagonists (VKA) for a composite outcome of ischemic and bleeding complications but increased major bleeding in patients with atrial fibrillation after successful transcatheter aortic valve replacement. Women are at higher risk of bleeding and stroke than men after transcatheter aortic valve replacement. It is unclear whether the effect of edoxaban on these complications varies in relation to sex. Objectives: This study was to assess the effect of edoxaban vs VKA according to sex in the ENVISAGE-TAVI AF trial. Methods: The primary outcomes were net adverse cardiovascular events (NACE) and major bleeding, assessed considering the effective time on study medication (safety analysis). Results: Out of 1,377 patients, 658 (47.8%) were women. Risks for ischemic and major bleeding outcomes were similar between women and men. Edoxaban compared to VKA was associated with a similar risk of NACE in women (HR: 1.16; 95% CI: 0.81-1.65) and men (HR: 1.08; 95% CI: 0.76-1.53; P for interaction = 0.820) and a higher risk of major bleeding in both sexes (P for interaction = 0.170). The risk increase of major bleeding was attenuated in women (HR: 1.11; 95% CI: 0.69-1.79) as compared to men (HR: 1.75; 95% CI: 1.07-2.85). There were no treatment-related differences for ischemic complications in both sexes. Conclusions: Edoxaban compared to VKA was associated with a similar risk of NACE and higher risk of major bleeding in both sexes. The increase in bleeding complications with edoxaban was attenuated in women.

19.
Front Cardiovasc Med ; 10: 1322459, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38162131

RESUMO

Background: Rotational atherectomy (RA) during percutaneous coronary intervention may cause transient bradycardia or a higher-degree heart block. Traditionally, some operators use prophylactic transvenous pacing wire (TPW) to avoid haemodynamic complications associated with bradycardia. Objective: We sought to establish the frequency of bail-out need for emergency TPW insertion in patients undergoing RA that have received no upfront TPW insertion. Methods: We performed a single-centre retrospective study of all patients undergoing RA between October 2009 and October 2022. Patient characteristics, procedural variables, and in-hospital complications were registered. Results: A total of 331 patients who underwent RA procedure were analysed. No patients underwent prophylactic TPW insertion. The mean age was 73.3 ± 9.1 years, 71.6% (n = 237) were male, while nearly half of the patients were diabetic [N = 158 (47.7%)]. The right coronary artery was the most common target for RA (40.8%), followed by the left anterior descending (34.1%), left circumflex (14.8%), and left main stem artery (10.3%). Altogether 20 (6%) patients required intraprocedural atropine therapy. Emergency TPW insertion was needed in one (0.3%) patient only. Eight (2.4%) patients died, although only one (0.3%) was adjudicated as being possibly related to RA-induced bradycardia. Five patients (1.5%) had ventricular fibrillation arrest, while nine (2.7%) required cardiopulmonary resuscitation. Six (1.8%) procedures were complicated by coronary perforation, two (0.6%) were complicated by tamponade, while 17 (5.1%) patients experienced vascular access complications. Conclusions: Bail-out transvenous temporary pacing is very rarely required during RA. A standby temporary pacing strategy seems reasonable and may avoid unnecessary TPW complications compared with routine use.

20.
Front Cardiovasc Med ; 9: 1022415, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36386308

RESUMO

Background: Old age and the presence of aortic stenosis are associated with the unfolding of the intrathoracic aorta. This may result in increased difficulties navigating catheters from the right compared to the left radial approach. Objective: To investigate whether increasing age or presence of severe aortic stenosis was associated with increased catheterization success rates from left (LRA) compared to right radial artery approach (RRA). Methods: We compared coronary angiography success rates of RRA and LRA according to different age groups and in a subgroup of patients with severe aortic stenosis. Results: A total of 21,259 coronary angiographies were evaluated. With increasing age, the first pass success rate from either radial access decreased significantly (p < 0.001). In patients aged <85 years, there was no difference between LRA and RRA. However, in patients aged ≥85 years, LRA was associated with significantly higher success rates compared to RRA (90.1 vs. 82.8%, p = 0.003). Patients aged ≥85 years received less contrast agent and had shorter fluoroscopy time when LRA was used [86.6 ± 41.1 vs. 99.6 ± 48.7 ml (p < 0.001) and 4.5 ± 4.1 min vs. 6.2 ± 5.7 min (p < 0.001), mean (±SD)]. In patients with severe aortic stenosis (n = 589) better first pass success rates were observed via LRA compared to the RRA route (91.9 vs. 85.1%, p = 0.037). Conclusion: LRA, compared to RRA, is associated with a higher first-pass catheter success rate for coronary artery angiography in patients aged ≥85 years and those with severe aortic stenosis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...