Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Transfusion ; 40(6): 693-6, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10864990

RESUMO

BACKGROUND: A reliable, validated method for rapidly determining HPC viability is essential for clinical cell engineering. STUDY DESIGN AND METHODS: A fluorometric cell viability assay using acridine orange and propidium iodide (AO/PI) was compared to the current standard, trypan blue (TB) exclusion. Viable cells stained with AO/PI fluoresce green under darkfield fluorescence microscopy, while nonviable cells fluoresce orange. Mixtures of fresh and heat-killed bone marrow were prepared and used as viability standards for evaluation of both assays. The frequency of CFU-GM was determined for each specimen. RESULTS: Cell viability measured by AO/PI was extremely linear, with measured and predicted viability in agreement from 0 to 100 percent of the viable cells and a coefficient of regression (r(2)) of 0.9921. The predicted-viability regression line fell within the 95% CI for AO/PI-measured viability. The coefficient of regression for TB-measured viability was 0.9584, with the predicted-viability regression line almost entirely outside the 95% CI. TB overestimated the percentage of viable cells, particularly below the 50-percent level. CFU-GM frequency correlated better with cell viability measured by AO/PI (r(2) = 0.979) than with that measured by TB (r(2) = 0.930). CONCLUSIONS: The AO/PI viability assay is a rapid, highly linear, functionally correlated assay that is superior to conventional viability measurement by TB exclusion.


Assuntos
Laranja de Acridina/análise , Sobrevivência Celular , Corantes Fluorescentes/análise , Células-Tronco Hematopoéticas/citologia , Propídio/análise , Coloração e Rotulagem/métodos , Azul Tripano/análise , Laranja de Acridina/metabolismo , Células da Medula Óssea/citologia , Células da Medula Óssea/metabolismo , Permeabilidade da Membrana Celular , Estudos de Avaliação como Assunto , Corantes Fluorescentes/metabolismo , Células-Tronco Hematopoéticas/metabolismo , Humanos , Microscopia de Fluorescência , Propídio/metabolismo , Sensibilidade e Especificidade , Azul Tripano/metabolismo
2.
Clin Chem ; 45(2): 199-205, 1999 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9931041

RESUMO

This multicenter study evaluated the Biosite Triage(R) Cardiac Panel as a quantitative, multimarker, whole blood system for the detection of acute myocardial infarction (MI). Optimum cutoffs for the discrimination of acute MI (n = 192 patients, 59 with MI) as determined by ROC curve analyses were as follows: 0.4 microgram/L for cardiac troponin I (cTnI); 4.3 microgram/L for the creatine kinase MB isoenzyme (CK-MB); and 107 microgram/L for myoglobin. The Triage Panel showed the following concordances for detection or rule-out of MI compared with established devices: cTnI >89%; CK-MB >81%; myoglobin >69%. No significant differences were present between methods for the same marker. Diagnostic efficiencies demonstrated comparable sensitivities and specificities for the diagnosis of MI in patients presenting with symptoms compared with the Dade, Beckman, and Behring CK-MB, cTnI, and myoglobin assays; the ratio of sensitivity to specificity for each marker was as follows: cTnI, 98%:100%; CK-MB, 95%:91%; myoglobin, 81%:92%. The areas under the ROC curves for the Biosite myoglobin, CK-MB, and cTnI were 0.818, 0.905, and 0.970, respectively; the areas were significantly different, P <0.05. In patients with skeletal muscle injury and renal disease, the Triage cTnI showed 94% and 100% specificity, respectively. The Triage panel offers clinicians a whole blood, point-of-care analysis of multiple cardiac markers that provides excellent clinical sensitivity and specificity for the detection of acute MI.


Assuntos
Creatina Quinase/sangue , Infarto do Miocárdio/diagnóstico , Mioglobina/sangue , Kit de Reagentes para Diagnóstico/normas , Troponina I/sangue , Estudos de Avaliação como Assunto , Humanos , Isoenzimas , Infarto do Miocárdio/sangue , Miocárdio/metabolismo , Curva ROC , Sensibilidade e Especificidade
4.
Clin Chem ; 44(1): 52-60, 1998 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9550558

RESUMO

We evaluated the ACCESS cardiac troponin I (cTnI) immunoassay as a marker for myocardial infarction (MI). Total imprecision was 6.0% to 13.5%, the minimum detectable concentration was 0.007 microg/L, and the limit of quantitation was 0.046 microg/L. Comparison of cTnI measurement between the ACCESS and Stratus systems (n = 114) showed a proportional difference: ACCESS cTnI = 0.0996 Stratus cTnI + 0.049 microg/L (r = 0.811). Fifty-nine of 61 ambulatory patients without cardiac symptoms had no detectable cTnI (95% range, 0.00 to 0.025 microg/L). The optimum cutoff for discriminating MI (n = 289, 45 with MI) was 0.15 microg/L by receiver operator characteristic curve analysis; at this cutoff, the ACCESS cTnI assay showed a sensitivity of 88.9% (95% CI, 79.7-98.1%) and specificity of 91.8% (95% CI, 88.4-95.2%). The ACCESS cTnI assay results showed 89.4% and 93.0% concordance with the MB isoenzyme of creatine kinase (CK-MB) mass and Stratus cTnI results, respectively, for classification of patients with suspected MI. The ACCESS cTnI assay appears to show sensitivity and specificity comparable with those of both CK-MB mass and Stratus cTnI assays for the diagnosis of MI in patients presenting within 12 h of onset of symptoms.


Assuntos
Infarto do Miocárdio/diagnóstico , Troponina I/análise , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/análise , Ensaios Enzimáticos Clínicos , Creatina Quinase/sangue , Feminino , Humanos , Técnicas Imunoenzimáticas , Isoenzimas , Falência Renal Crônica/sangue , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/química , Músculo Esquelético/lesões , Doenças Musculares/metabolismo , Infarto do Miocárdio/sangue , Estudos Prospectivos , Sensibilidade e Especificidade , Troponina I/sangue
5.
J Anim Breed Genet ; 111(1-6): 148-51, 1994 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-21395762

RESUMO

SUMMARY: A group of diseases termed combined immunodeficiency (CID) results in a severe form of immunodeficiency. While CID in humans has two genetics bases, in Arabian it is inherited in an autosomal recessive manner. Kettler et al. (1989) determined that uric acid was significantly (p < .001) greater in the serum of carrier Arabian horses than in non-carrier horses. The current study measured serum levels of hypoxanthine and xanthine two other products of this pathway. There were no significant differences (p > 0.05) between carrier and non-carrier horse's serum levels of hypoxanthine or xanthine. These data, combined with our previous ones suggest that an enzymatic lesion in the purine salvage pathway may occur at the urate oxidase step. ZUSAMMENFASSUNG: Serum-Hypoxanthin- und -Xanthin-Spiegel in Pferden mit Heterozygotie für kombinierte Immundefizienz Kombinierte Immundefizienz (CID), die zu einer schweren Krankheit führt, hat beim Menschen zwei genetische Ursachen, wird aber bei Araberpferden autosomal rezessiv vererbt. Kettler u. Ma. (1989) fanden den Harnsäureserumspiegel in Überträgern signifikant höher als in freien Tieren. Hier wurden mit Hypoxanthin und Xanthin zwei andere Produkte des biochemischen Pfades bestimmt, jedoch keine statistisch signifikanten Unterschiede zu Nicht-Trägern der CID gefunden. Die Ergebnisse zusammen mit unseren früheren lassen vermuten, daß der Enzymmangel im Purinpfad auf der Harnsäureoxidationsstufe existiert.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...