J Radiol Prot ; 37(3): 715-727, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28631620

RESUMO

The aim of the present study is to analyse quantitatively the potential reduction of doses to the eye lens and the hands of an operator and a nurse by the use of a pelvic lead blanket during coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) procedures. Thermoluminescent dosimeters were used to assess dose levels to the left eye lens and fingers on both hands of both physician and nurses during single procedures performed with or without the lead blanket. The measurements were carried out at one medical centre and include dosimetric data from 100 procedures. Additional measurements including physician's and patient's doses were made on phantoms in the laboratory. In order to determine the reduction potential of the lead blanket, the doses normalized to DAP (Dose-Area Product) corresponding to the same position of dosimeter were compared against each other for both procedure categories (with and without protection). There was no statistically significant decrease observed in physicians' and nurses' eye lens doses, nor in doses normalized to DAP due to the use of the lead pelvic shield in clinic. However, some trend in reducing the eye lens doses by this shield can be observed. Regarding finger doses, the differences are statistically significant but only for physicians. The mean DAP-normalised doses to the eye lens and left and right finger of physicians, in the presence of a ceiling-suspended transparent lead shield, were 2.24e-5 ± 1.41e-5 mSv/µGym2, 2.31e-4 ± 1.21e-4 mSv/µGym2, and 2.60e-5 ± 1.57e-5 mSv/µGym2 for standard procedures performed without the lead blanket, and 1.77e-5 ± 1.17e-5 mSv/µGym2, 1.70e-4 ± 1.01e-4 mSv/µGym2, and 1.86e-5 ± 1.13e-5 mSv/µGym2 for procedures performed with it. A comparison of the results from the laboratory and the clinic shows that they are consistent regarding the eye lens, while for fingers it suggests that the dose reduction properties of the lead shield are related to the physician's work technique and both patient and lead blanket sizes or its positioning. The highest degree of reduction is observed for cranial and caudal projections together with the use of a patient-adjustable lead blanket; about a 2-fold decrease in finger doses is expected for optimum conditions. However, the laboratory measurements suggest that the use of lead blanket might slightly increase the patient dose, but only when specific projections are constantly used. This limitation should be considered by cardiologists during clinical work if this protection is used. In the light of the presented results, the ceiling-suspended transparent lead shield and the lead glasses seem to be the preferred way to reduce the doses to the eye lens, compared to the lead blanket.


Assuntos
Cardiologistas , Mãos/efeitos da radiação , Chumbo , Cristalino/efeitos da radiação , Enfermeiras e Enfermeiros , Exposição Ocupacional/prevenção & controle , Lesões por Radiação/prevenção & controle , Proteção Radiológica/instrumentação , Angioplastia , Angiografia Coronária , Dispositivos de Proteção dos Olhos , Humanos , Pelve , Dosimetria Termoluminescente
2.
J Radiol Prot ; 36(2): 309-18, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27183002

RESUMO

The aim of the study was to check, in clinical practice, the potential for the dose reduction of lead eyewear and a ceiling-suspended shield used to protect the eye lens of physicians working in interventional cardiology. To this end, for the lead eyewear, the dose reduction factors were derived to correct the readings from a dosimeter used routinely outside the glasses. Four types of lead eyewear with attached loose thermoluminescent dosimeters and EYE-D dosimeters were worn by physicians in two clinical centres, for two-month periods, during coronary angiography (CA), percutaneous coronary intervention (PCI), and pacemaker procedures. In order to analyse, separately, how a ceiling-suspended lead screen absorbs the scattered radiation, a series of measurements was carried out during single CA/PCI procedures performed with and without the protection. The lead eyewear may reduce the doses to the eye closest to the x-ray tube by a factor between 1.1 and 3.4, depending on its model and the physician's position. The effectiveness of the eyewear may, however, vary-even for the same model and physician-almost twofold between different working periods. The ceiling-suspended shield decreases the doses in clinical practice by a factor of 2.3. The annual eye lens doses without the eyewear estimated from routine measurements are high-above or close to the new eye lens dose limit established by the recent EU Basic Safety Standards, even though the ceiling-suspended shield was used. Therefore, to comply with the new dose limit that is set in the Directive, protection of the eyes of physicians with high workloads might require the use of both the eyewear and the ceiling-suspended shield.


Assuntos
Cardiologia , Dispositivos de Proteção dos Olhos , Cristalino/efeitos da radiação , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Radiografia Intervencionista , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Radiometria/métodos , Dosimetria Termoluminescente