RESUMO
The characterization of vascular geometry is a fundamental step towards the correct interpretation of coronary artery disease. In this work, we report a comprehensive comparison of the geometry featured by coronary vessels as obtained from coronary computed tomography angiography (CCTA) and the combination of intravascular ultrasound (IVUS) with bi-plane angiography (AX) modalities. We analyzed 34 vessels from 28 patients with coronary disease, which were deferred to CCTA and IVUS procedures. We discuss agreement and discrepancies between several geometric indexes extracted from vascular geometries. Such an analysis allows us to understand to which extent the coronary vascular geometry can be reliable in the interpretation of geometric risk factors, and as a surrogate to characterize coronary artery disease.
Assuntos
Doença da Artéria Coronariana , Vasos Coronários , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Ultrassonografia de IntervençãoRESUMO
Aims: Assessment of minimum lumen areas in intravascular ultrasound (IVUS) pullbacks is time-consuming and demands adequately trained personnel. In this work, we introduce a novel and fully automated pipeline to segment the lumen boundary in IVUS datasets. Methods and results: First, an automated gating is applied to select end-diastolic frames and bypass saw-tooth artefacts. Second, within a machine learning (ML) environment, we automatically segment the lumen boundary using a multi-frame (MF) convolutional neural network (MFCNN). Finally, we use the theory of Gaussian processes (GPs) to regress the final lumen boundary. The dataset consisted of 85 IVUS pullbacks (52 patients). The dataset was partitioned at the pullback-level using 73 pullbacks for training (20 586 frames), 6 pullbacks for validation (1692 frames), and 6 for testing (1692 frames). The degree of overlapping, between the ground truth and ML contours, median (interquartile range, IQR) systematically increased from 0.896 (0.874-0.933) for MF1 to 0.925 (0.911-0.948) for MF11. The median (IQR) of the distance error was also reduced from 3.83 (2.94-4.98)% for MF1 to 3.02 (2.25-3.95)% for MF11-GP. The corresponding median (IQR) in the lumen area error remained between 5.49 (2.50-10.50)% for MF1 and 5.12 (2.15-9.00)% for MF11-GP. The dispersion in the relative distance and area errors consistently decreased as we increased the number of frames, and also when the GP regressor was coupled to the MFCNN output. Conclusion: These results demonstrate that the proposed ML approach is suitable to effectively segment the lumen boundary in IVUS scans, reducing the burden of costly and time-consuming manual delineation.
RESUMO
OBJECTIVES: To evaluate the diagnostic performance of a novel computational algorithm based on three-dimensional intravascular ultrasound (IVUS) imaging in estimating fractional flow reserve (IVUSFR ), compared to gold-standard invasive measurements (FFRINVAS ). BACKGROUND: IVUS provides accurate anatomical evaluation of the lumen and vessel wall and has been validated as a useful tool to guide percutaneous coronary intervention. However, IVUS poorly represents the functional status (i.e., flow-related information) of the imaged vessel. METHODS: Patients with known or suspected stable coronary disease scheduled for elective cardiac catheterization underwent FFRINVAS measurement and IVUS imaging in the same procedure to evaluate intermediate lesions. A processing methodology was applied on IVUS to generate a computational mesh condensing the geometric characteristics of the vessel. Computation of IVUSFR was obtained from patient-level morphological definition of arterial districts and from territory-specific boundary conditions. FFRINVAS measurements were dichotomized at the 0.80 threshold to define hemodynamically significant lesions. RESULTS: A total of 24 patients with 34 vessels were analyzed. IVUSFR significantly correlated (r = 0.79; P < 0.001) and showed good agreement with FFRINVAS , with a mean difference of -0.008 ± 0.067 (P = 0.47). IVUSFR presented an overall accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of 91%, 89%, 92%, 80%, and 96%, respectively, to detect significant stenosis. CONCLUSION: The computational processing of IVUSFR is a new method that allows the evaluation of the functional significance of coronary stenosis in an accurate way, enriching the anatomical information of grayscale IVUS.
Assuntos
Algoritmos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Imageamento Tridimensional , Ultrassonografia de Intervenção/métodos , Idoso , Cateterismo Cardíaco , Angiografia Coronária , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos TestesRESUMO
Atherosclerotic plaque rupture and erosion are the most important mechanisms underlying the sudden plaque growth, responsible for acute coronary syndromes and even fatal cardiac events. Advances in the understanding of the culprit plaque structure and composition are already reported in the literature, however, there is still much work to be done toward in-vivo plaque visualization and mechanical characterization to assess plaque stability, patient risk, diagnosis and treatment prognosis. In this work, a methodology for the mechanical characterization of the vessel wall plaque and tissues is proposed based on the combination of intravascular ultrasound (IVUS) imaging processing, data assimilation and continuum mechanics models within a high performance computing (HPC) environment. Initially, the IVUS study is gated to obtain volumes of image sequences corresponding to the vessel of interest at different cardiac phases. These sequences are registered against the sequence of the end-diastolic phase to remove transversal and longitudinal rigid motions prescribed by the moving environment due to the heartbeat. Then, optical flow between the image sequences is computed to obtain the displacement fields of the vessel (each associated to a certain pressure level). The obtained displacement fields are regarded as observations within a data assimilation paradigm, which aims to estimate the material parameters of the tissues within the vessel wall. Specifically, a reduced order unscented Kalman filter is employed, endowed with a forward operator which amounts to address the solution of a hyperelastic solid mechanics model in the finite strain regime taking into account the axially stretched state of the vessel, as well as the effect of internal and external forces acting on the arterial wall. Due to the computational burden, a HPC approach is mandatory. Hence, the data assimilation and computational solid mechanics computations are parallelized at three levels: (i) a Kalman filter level; (ii) a cardiac phase level; and (iii) a mesh partitioning level. To illustrate the capabilities of this novel methodology toward the in-vivo analysis of patient-specific vessel constituents, mechanical material parameters are estimated using in-silico and in-vivo data retrieved from IVUS studies. Limitations and potentials of this approach are exposed and discussed.