1.
Int J Cardiol ; 400: 131807, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38272130

RESUMO

BACKGROUND: Left ventricular assist devices (LVADs) are an increasingly used strategy for the management of patients with advanced heart failure (HF). Subcutaneous implantable cardioverter defibrillator (S-ICD) might be a viable alternative to conventional ICDs with a lower risk of short- and long-term of device-related complications and infections.The aim of this multicenter study was to evaluate the outcomes and management of S-ICD recipients who underwent LVAD implantation. METHODS: The study population included patients with a preexisting S-ICD who underwent LVAD implantation for advanced HF despite optimal medical therapy. RESULTS: The study population included 30 patients (25 male; median age 45 [38-52] years).The HeartMate III was the most common LVAD type. Median follow-up in the setting of concomitant use of S-ICDs and LVADs was 7 months (1-20).There were no reports of inability to interrogate S-ICD systems in this population. Electromagnetic interference (EMI) occurred in 21 (70%) patients. The primary sensing vector was the one most significantly involved in determining EMI. Twenty-seven patients (90%) remained eligible for S-ICD implantation with at least one optimal sensing vector. The remaining 3 patients (10%) were ineligible for S-ICD after attempts of reprogramming of sensing vectors. Six patients (20%) experienced inappropriate shocks (IS) due to EMI. Six patients (20%) experienced appropriate shocks. No S-ICD extraction because of need for antitachycardia pacing, ineffective therapy or infection was reported. CONCLUSIONS: Concomitant use of LVAD and S-ICD is feasible in most patients. However, the potential risk of EMI oversensing, IS and undersensing in the post-operative period following LVAD implantation should be considered. Careful screening for EMI should be performed in all sensing vectors after LVAD implantation.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Marca-Passo Artificial , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Coração Auxiliar/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento
2.
Curr Probl Cardiol ; 48(2): 101506, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36402214

RESUMO

To evaluate the safety and effectiveness of anticoagulation alone in HeartMate3 patients. According to antithrombotic regimen, patients were divided into 2 groups: Group-1(warfarin+aspirin) and Group-2(warfarin). A comparison of hemocompatibility-related adverse events (HRAEs), hemocompatibility score (HCS), and hemocoagulative laboratory markers, both qualitative and quantitative, between the 2 groups were performed. Fifty patients were enrolled, 28 (56%) in Group-1 and 22 in Group-2 (44%), without statistical differences at baseline. Median time of follow-up was 590 days (IQR: 410.25-1007.50). Eighteen HRAEs (36.0%) occurred: 17 in Group-1 (34%) and 1 in Group-2 (2%) (P < 0.001). The net HCS for Group-1 versus Group-2 was 24 points and 1 point (OR 12.116[2.034-233.226], P = 0.023), respectively. Hemocoagulative values turned into the normality and remained stable during follow-up, without differences between groups, except for ASPI-test (P = 0.003). HeartMate3 showed a high hemocompatibility independently from antithrombotic therapy. Aspirin avoidance resulted a safe and effective strategy since it reduced hemorrhagic events, without increasing thrombotic risk.


Assuntos
Fibrinolíticos , Varfarina , Humanos , Varfarina/efeitos adversos , Fibrinolíticos/efeitos adversos , Anticoagulantes/efeitos adversos , Hemorragia/induzido quimicamente , Hemorragia/tratamento farmacológico , Aspirina/efeitos adversos