PLoS One ; 13(2): e0192879, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29444158

RESUMO

The accuracy of quantitative stereological analysis tools such as the (physical) disector method substantially depends on the precise determination of the thickness of the analyzed histological sections. One conventional method for measurement of histological section thickness is to re-embed the section of interest vertically to its original section plane. The section thickness is then measured in a subsequently prepared histological section of this orthogonally re-embedded sample. However, the orthogonal re-embedding (ORE) technique is quite work- and time-intensive and may produce inaccurate section thickness measurement values due to unintentional slightly oblique (non-orthogonal) positioning of the re-embedded sample-section. Here, an improved ORE method is presented, allowing for determination of the factual section plane angle of the re-embedded section, and correction of measured section thickness values for oblique (non-orthogonal) sectioning. For this, the analyzed section is mounted flat on a foil of known thickness (calibration foil) and both the section and the calibration foil are then vertically (re-)embedded. The section angle of the re-embedded section is then calculated from the deviation of the measured section thickness of the calibration foil and its factual thickness, using basic geometry. To find a practicable, fast, and accurate alternative to ORE, the suitability of spectral reflectance (SR) measurement for determination of plastic section thicknesses was evaluated. Using a commercially available optical reflectometer (F20, Filmetrics®, USA), the thicknesses of 0.5 µm thick semi-thin Epon (glycid ether)-sections and of 1-3 µm thick plastic sections (glycolmethacrylate/ methylmethacrylate, GMA/MMA), as regularly used in physical disector analyses, could precisely be measured within few seconds. Compared to the measured section thicknesses determined by ORE, SR measures displayed less than 1% deviation. Our results prove the applicability of SR to efficiently provide accurate section thickness measurements as a prerequisite for reliable estimates of dependent quantitative stereological parameters.


Assuntos
Técnicas Histológicas/métodos , Animais , Calibragem , Técnicas Histológicas/normas , Rim/anatomia & histologia , Camundongos , Microscopia/métodos , Microtomia/métodos , Inclusão em Parafina/métodos , Inclusão em Plástico/métodos , Análise Espectral/métodos
2.
J Zoo Wildl Med ; 44(2): 487-90, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23805573

RESUMO

A severe case of polycystic nephropathy was seen in an adult European roe deer (Capreolus capreolus), culled in a German hunting district. The doe had bilaterally drastically enlarged kidneys, completely riddled with variably sized, fluid-filled cysts of up to 4 cm in diameter. Histopathologic and ultrastructural examination revealed disseminated formation of cysts with flattened epithelial cell linings in the entire renal parenchyma, as well as severe dilations of renal tubules, marked interstitial fibrosis, nephron atrophy, and chronic interstitial lymphoplasmacytic infiltrations in the intercystic kidney tissue. These morphologic findings most likely resemble the hallmarks of autosomal dominant polycystic disease in humans, and present the first detailed description of a case of polycystic kidney disease in a roe deer.


Assuntos
Cervos , Doenças Renais Policísticas/veterinária , Animais , Feminino , Alemanha/epidemiologia , Doenças Renais Policísticas/epidemiologia , Doenças Renais Policísticas/patologia